Panduit PDM4.0 EI Manual

PDM4.0 EI Setup
PA28091A01
Rev. 02 2-2017
PAT 4.0 AUTOMATIC CABLE TIE INSTALLATION SYSTEM
ELECTRONIC INTERFACE USER MANUAL
© Panduit Corp. 2017
Original Instructions
EI (Electronic Interface) Instructions
For use with the following Systems &
respective Operational Manuals:
PAT 4.0 FAMILY TOOLS: Automatic Cable Tie Installation Tools
PDM4.0: Dispenser
PHM: Feeder Hoses
Operation Manual (PA27647A01)
PDM4.0 Data Manager Operations Manual (PA25060A01)
EI I/O port (25 Pin Connector) is internally connected
to Optically Isolated Modules,
WARNING
•TO REDUCE THE RISK OF INJURY,
USER MUST READ INSTRUCTION
MANUAL
Email:
techsupport@panduit.com
EU Website:
www.panduit.com/emea
EU Email: emeatoolservicecenter
@panduit.com
www.panduit.com
Panduit Corp. • Tinley Park, IL USA
Technical Support
Tel: 1-800-777-3300
Panduit Europe • EMEA Service Center
Almelo, Netherlands
Tel: +31 546 580 452 • Fax: +31 546 580 441

PAT 4.0 AUTOMATIC CABLE TIE INSTALLATION SYSTEM
ELECTRONIC INTERFACE USER MANUAL
© Panduit Corp. 2017
PA28091A01_02 Page 1of 9 2-2017
1: INTRODUCTION
The PAT Fully Automatic Cable Tie Installation System was designed by Panduit Corporation to install
Panduit continuously molded cable ties for high volume wire harnessing applications.
NOTE: In the interest of higher quality and value, Panduit products are
continually being improved and updated.
Consequently, pictures may vary from the enclosed product.
2: SYSTEM SPECIFICATIONS
The Panduit Corporation PAT Cable Tie Installation System consists of four compatible units: the PAT
Installation Tool, the PDM Dispenser, the PHM Feeder Hose, and Panduit Pan-Ty XMR Cable Ties.
Cable ties are available in reels of 5000 pcs.
NOTE:Any substitution may cause serious damage to the system and/or injury to the operator.
SYMBOL EXPLANATION
Warning: Hazardous Voltage
Disconnect power before servicing
Warning: Head Obstruction
Warning: Sever Hand
Warning: Wear Safety Glasses
Caution: Air Inlet
WEEE Compliance
Read the Manual
VAC
FUSE

PAT 4.0 AUTOMATIC CABLE TIE INSTALLATION SYSTEM
ELECTRONIC INTERFACE USER MANUAL
© Panduit Corp. 2017
PA28091A01_02 Page 2of 9 2-2017
Automatic Cable Tie Tool System Overview & Tool Cycle:
(Applies to all Panduit Automatic Cable Tie Tool Systems, Listed on Page 1)
Tool Cycle with Customer Controlled Tool Actuator / Robot
& Use of EI-Port:
1. Customer Controlled Actuator closes Tool Head Jaw lever, closing Jaw & S1 switch, to enable EI-
Port to receive remote trigger input at EI 25 pin D-sub. Connector.
{NOTE: Customer Actuator must hold Tool Jaw Lever closed during entire cycle for proper Cable
Tie Application}
2. Short “primary” air burst sends tie past Dispenser “Gate” and Dispenser Tie Exit Sensor, S2, and into
Tie Transfer Hose, then “primary” air burst stops.
3. “Gate” in Dispenser closes and second air burst transports tie through Tie Transfer Hose toward
Tool Head.
4. Tie enters Tool Head, passing through Tie Entry Sensor, S3, stopping in jaws of Tool Head, and
Dispenser moves the next tie into position ready for next cycle.
5. Upper Jaw moves to thread tie strap through tie head, then tensioning around wire bundle takes
place.
6. Tie reaches desired tension and excess tie strap is cut-off, activating Detent Sensor S4 to end
cycle.

PAT 4.0 AUTOMATIC CABLE TIE INSTALLATION SYSTEM
ELECTRONIC INTERFACE USER MANUAL
© Panduit Corp. 2017
PA28091A01_02 Page 3of 9 2-2017
EI I/O Port Modules: Electrical Specification / Schematic
24VDC
PLC PNP Sourcing Output
PDM Input
Output
Common
Mx Input (+)
Mx Input (-)
24VDC
PDM FET Output PLC Input Common Source
Input -
Input +
Mx Output (-)
Mx Output (+)
24VDC
PLC NPN Sinking Output
PDM Input
Output
Common
Mx Input (+)
Mx Input (-)
Inputs from
Customer Controller
+3 to 30VDC,
10mA max. @ 30VDC.
(Drop-out voltage
1VDC min.)
EI Connector
at rear of Panduit
Cable Tie Dispenser
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
24VDC
PDM FET Output PLC Input Common Ground
Input -
Input +
Mx Output (-)
Mx Output (+)
Outputs to
Customer Controller
MOSFET output
3 to 30VDC,
0.1A max.
Input/Output
Isolation 3500V

PAT 4.0 AUTOMATIC CABLE TIE INSTALLATION SYSTEM
ELECTRONIC INTERFACE USER MANUAL
© Panduit Corp. 2017
PA28091A01_02 Page 4of 9 2-2017
I/O Port: Pin-Out (see functions, page 5)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
12 VDC Output (+)
Remote Operation Enable: M0 Input (+)
Trigger: M1 Input (+)
Reset: M2 Input (+)
System Ready/Problem: M3 Output (-)
Cycle In Progress: M4 Output (-)
Tool Jaw Indicator: M7 Output (-)
Error Code 1: M5 Output (-)
Error Code 2: M6 Output (-)
Chassis Ground: Common
12 VDC Output (+)
M0 Input (-): Remote Operation Enable
M1 Input (-): Trigger
M2 Input (-): Reset
M3 Output (+): System Ready/Problem
M4 Output (+): Cycle In Progress
M7 Output (+): Tool Jaw Indicator
M5 Output (+): Error Code 1
M6 Output (+): Error Code 2
VDC Ground: Common

PAT 4.0 AUTOMATIC CABLE TIE INSTALLATION SYSTEM
ELECTRONIC INTERFACE USER MANUAL
© Panduit Corp. 2017
PA28091A01_02 Page 5of 9 2-2017
I/O Port Functions
(“M#” indicates I/O Module #)
IO Function Definition
I/O
NUMBER
25 PIN D-SUB
Pin Numbers
+ -
12 VDC Output @ 0.75 A 1,14
Chassis Ground 10
DC Ground 23
INPUTS (To Dispenser-EI from Remote Control)
Remote Operation Enable (ROE) M0 2 15
Trigger (start cycle) M1 316
Reset M2 4 17
OUTPUTS (From Dispenser-EI to Remote Control)
System Ready / Error M3 18 5
Cycle In Process (CIP) M4 19 6
Error Code 1 M5 20 7
Error Code 2 M6 21 8
Tool Jaw Indicator M7 22 9
Table 1: IO Function Connector Pin Definition
Error Code Definition
(“M#” indicates I/O Module #)
(Check PDM display for additional information and correction)
M5 & M6 Error Code
M5
M6
No Error Closed Closed
Exit Sensor Error Open Closed
Tool Sensor Error Closed Open
Tie/PDM Error Open Open
Table 2: Error Code Definition

PAT 4.0 AUTOMATIC CABLE TIE INSTALLATION SYSTEM
ELECTRONIC INTERFACE USER MANUAL
© Panduit Corp. 2017
PA28091A01_02 Page 6of 9 2-2017
Cycle Progress Signal Definition
(“M#” indicates I/O Module #)
(See Flow Chart on pages 6 & 7 for cycle timing)
INPUTS OUTPUTS
Cycle
Progress M0
ROE
M1
Trigger
M2
Reset
M3
Ready
M4
CIP
M5
Error 1
M6
Error 2
M7
Jaw
Indicator
PLC Off
Open
No
Effect
No
Effect
Closed
Open
Error
Code
Error
Code
Open
PLC On
PDM Error
Closed
Open
Open
Open
Open
Error
Code
Error
Code
Open
PLC On
PDM Ready
Closed
Open
Open
Closed
Open
Error
Code
Error
Code
Open
PLC On
PDM Reset
Closed
No
Effect
Closed
Open
Open
Error
Code
Error
Code
Open
PLC On
PDM Ready
JAW Closed
Closed
Open
Open
Closed
Open
Error
Code
Error
Code
Closed
PLC On
PDM Ready
JAW Closed
Cycle In
Progress
Closed
Closed
Open
Closed
Closed
Error
Code
Error
Code
Closed
PLC On
PDM Ready
Cycle In
Progress
Closed
Closed
Open
Closed
Closed
Error
Code
Error
Code
Open/
Closed
PLC On
PDM Ready
JAW Closed
Cycle Not In
Progress
Closed
Closed
Open
Closed
Open
Error
Code
Error
Code
Closed
Table 3: Cycle Progress Definition
* M7 must be closed to start cycle. M7 may remain “Closed” continually or “Open” at end of
cycle. M7 should remain closed during entire cycle indicating Tool Jaw Lever is held closed to
allow proper cable tie application. If Tool Jaw Lever opens after cycle in progress, the cycle will
continue and cable tie may not thread into tool tensioning mechanism. This may create Tie in Tool
Error.
* Dispenser outputs M3, M4, M5, M6 & M7 may be monitored by the PLC without the need to
drive Dispenser inputs M0, M1 & M2.

PAT 4.0 AUTOMATIC CABLE TIE INSTALLATION SYSTEM
ELECTRONIC INTERFACE USER MANUAL
© Panduit Corp. 2017
PA28091A01_02 Page 7of 9 2-2017
EI PLC Program Flow Chart Recommendation
M0 = On
M1 = Off
M2 = Off
M3 = On? Check PDM display
Check M3, M5, M6
PLC wiring
No M5 = Off?
or
M6 = Off? Yes
Check PDM display
M0 = On
M1 = Off
M2 = On
Wait 100mS
No
Start PLC
Yes
Position Tool,
Close Jaw and
Wait 50mS
M3 = On?
and
M7 = On? No
Check Jaw
Actuator
Check M7 PLC
wiring
M0 = On
M1 = Off
M2 = Off
Reset PLC
Start Cycle
M0 = On
M1 = On
M2 = Off
Yes
M4 = On? Wait 750mS
(First cycle delay)
No M4 = On? Check PDM display
Check Jaw Actuator
Check M4 PLC wiring
No
Wait 650mS
(Cycle completion
time)
Yes
M4 = On?
Yes
Open Tool Jaw
Move Tool from Bundle
Check PDM display
Remove Tie in Tool
Restart PLC Program
Yes
Cycle Complete
Cycle Not Complete
No
Notes: 1. Input “Off or Open” = Applies voltage less than minimum drop-out level.
2. Input “On or Closed” = Applies voltage within specified input range.
3. Output “Off or Open” = Stops current flow.
4. Output “On or Closed” = Allows current flow.

PAT 4.0 AUTOMATIC CABLE TIE INSTALLATION SYSTEM
ELECTRONIC INTERFACE USER MANUAL
© Panduit Corp. 2017
PA28091A01_02 Page 8of 9 2-2017
Cable Tie Dispenser Display for Errors & Corrective Action
Dispenser
Display
Possible Cause
Corrective Action
“Dispenser jam -
check tie loading”
Dispenser rotary receiver
did not advance next tie
into position; due to bent
cable tie, or jam of carrier
strip in strip exit chute.
{PDS-EI Only: Or Cable
Tie Reel Moved off of Reel
Pivot Disk on Dispenser
Frame}
1. Press "Buzzer" button to turn buzzer off.
2. Check rotary receiver and connection block for jammed cable tie, and
check for jam in carrier strip exit chute.
3. Press "Unload" to back loose cable ties from rotary receiver & un-jam.
4. Cut excess carrier strip and any distorted or damaged cable ties from
cable tie reel.
5. Close Cover and perform loading procedure.
“Out of ties or tie
in dispenser”
A. Reel empty; dispenser
out of cable ties.
B. Reel not empty; tool
cycled without enough
cable ties loaded,
C. Cable tie prevented
from leaving dispenser.
A. 1. Press "Buzzer" button to turn buzzer off.
2. Press "Continue"; then "Menu" to bring up "Reset" display.
3. Press "Reset load" to bring up "Load, Unload, Menu" display and
perform the standard reloading procedure.
B. 1. Press "Buzzer" button to turn buzzer off.
2. Press "Continue"; then "Menu" to bring up "Reset" display.
3. Press "Reset load" to bring up "Load, Unload, Menu" display.
4. Press "Load" to load one (1) cable tie and resume operation.
C. 1. Disconnect air hose and feeder hose from dispenser.
2. Remove cable tie from Dispenser connector block, if present. (if tie
does not come out freely, turn dispenser off / then on again, to reset
rotary receiver position). If not able to remove a stuck tie, notify your
maintenance department.
3. After Cable Tie is removed, reconnect air hose and feeder hose to
dispenser.
4. Press "Continue"; then "Menu" button to bring up "Reset" display.
5. Press "Reset load" to bring up "Load, Unload, Menu" display.
6. Press "Load" to load one (1) cable tie and resume operation.
“Cover is open, no
tie loaded”
A. Cover was open when
"Load" was pressed.
B. Cover was open when
tool was cycled.
A. 1. Press "Buzzer" button to turn buzzer off.
2. Close Cover.
3. Resume loading procedure.
B. 1. Press "Buzzer" to turn buzzer off.
2. Close Cover.
3. Press "Load" to load one (1) cable tie and resume operation.
“Check for low air
pressure” (or
“high”)
A. Incoming air pressure
too low or too high.
B. Air not connected.
A. 1. Press "Buzzer" button to turn buzzer off. 2. Set air pressure 65-85
PSIG (4.5-5.8 bar), with max. 10 PSIG (0.7 bar) drop.
B. Connect air to PDM.
“Tie stuck in exit
sensor” or
“Blocked or dirty
exit sensor” or
“No exit sensor
seen – service
tool soon”
Exit sensor in dispenser is
obstructed by a cable tie or
excess debris (dirt, grime).
or
Cable tie in feeder hose
when cycle started.
or
Exit sensor in dispenser is
not functioning properly.
1. Press "Buzzer" button to turn buzzer off.
2. Disconnect feeder hose from dispenser and remove tie from dispenser
connector block if present (if tie does not come out freely, turn
dispenser off / then on again, to reset rotary receiver position). If not
able to remove a stuck tie, notify your maintenance department.
3. Reconnect feeder hose, and resume operation.
4. If tie is not found, reconnect feeder hose and follow the same
Corrective Action for "Tie in hose - press air burst" error to remove
the cable tie from the system.
5. If the same error is repeated, clean the dispenser exit sensor lens and
resume operation.
6. If the same error is still repeated, maintenance is required to replace the
exit sensor.

PAT 4.0 AUTOMATIC CABLE TIE INSTALLATION SYSTEM
ELECTRONIC INTERFACE USER MANUAL
© Panduit Corp. 2017
PA28091A01_02 Page 9of 9 2-2017
Cable Tie Dispenser Display for Errors & Corrective Action
(Continued)
Dispenser
Display
Possible Cause
Corrective Action
“Blocked or dirty
tool sensor”
or
“Tie stuck in tool
sensor”
Tool sensor is obstructed
by a cable tie, or excess
debris (dirt, grime).
1. Press "Buzzer" button to turn buzzer off'.
2. Disconnect feeder hose from tool. Look for cable tie in tool or tool end
of hose and remove cable tie if present; then reconnect feeder hose,
and resume operation.
3. If cable tie is not found, reconnect feeder hose and follow the same
Corrective Action for "Tie in hose - press air burst" error to remove the
cable tie from the system.
4. If the same error is repeated, clean tool sensor lens.
“Detent sensor
blocked or dirty”
Detent sensor is obstructed
by debris because of full Tip
Collector, or detent sensor
lens is dirty.
1. Press "Buzzer" button to turn buzzer off.
2. Remove cable tie from jaw area of tool. 3. Empty Tip Collector.
4. Press "Continue" button and resume operation.
5. If message reappears, Tool maintenance required to clean detent
sensor.
“Switch #X is
stuck or broken”
A switch (buttons #1, 2, 3, 4
near the Dispenser Display
or the Tool Jaw actuator /
trigger) was held down or
was stuck when the
dispenser was turned on.
This message remains if
there is a bad switch.
1. The message will disappear when the designated switch has been freed
or released.
2. If the message does not disappear, then the designated switch is bad,
and the Dispenser or Tool requires maintenance.
“Jaw sensor
error”
Cable tie stopped in tool
gripper gears.
1. Press "Buzzer" button to turn buzzer off.
2. Remove the cable tie from the jaw area.
3. Press "Continue" and resume operation.
“Tie in tool”
Tie in tool jaws-cycle not
complete; Due to:
Large air pressure drop.
Or bundle too large.
Or severe bend in hose.
Or jaw opened during cycle.
1. Press "Buzzer" button to turn buzzer off.
2. Remove cable tie and any obstruction from the jaw area.
3. Press "Continue" to resume operation.
4. Correct any conditions that prevent Tie cycle from being completed.
“Tie in hose –
press air burst”
or
“Blocked hose-
failed back
pressure test”
Cable tie stayed in feeder
hose during cycle; Due to:
Severe bend in hose.
Or low air pressure.
Or an interrupted cycle.
1. Press "Buzzer" button to turn buzzer off.
2. Straighten feeder hose to eliminate bends or twists, then point tool
away from yourself and others.
3. Press "Air burst" to advance cable tie to jaw area of tool, and "Tie in
tool" message will appear and buzzer will sound (If tie does not
advance to tool jaw after pressing "Air Burst" several times, replace
feeder hose). Press "Buzzer" button to turn buzzer off.
4. Remove tie from jaw area and press "Continue", then press "Load" to
load one cable tie and resume operation.