Parker Pneumatic PR364 Quick guide

Pneumatic Division North America
Richland, Michigan 49083
Installation and Service Instructions
3R100P
1/4" PR364 & 1/2" PR10 Regulators
ISSUED: April, 2003
Supersedes: January, 2003
Doc.# 3R100, ECN# 030337, Rev. 3
!
WARNING
To avoid unpredictable system behavior that can cause personal injury
and property damage:
• Disconnect electrical supply (when necessary) before installation,
servicing, or conversion.
• Disconnect air supply and depressurize all air lines connected to
this product before installation, servicing, or conversion.
• Operate within the manufacturer’s specified pressure, temperature,
and other conditions listed in these instructions.
• Medium must be moisture-free if ambient temperature is below
freezing.
• Service according to procedures listed in these instructions.
• Installation, service, and conversion of these products must be
performed by knowledgeable personnel who understand how
pneumatic products are to be applied.
• After installation, servicing, or conversion, air and electrical
supplies (when necessary) should be connected and the product
tested for proper function and leakage. If audible leakage is present,
or the product does not operate properly, do not put into use.
• Warnings and specifications on the product should not be covered
by paint, etc. If masking is not possible, contact your local
representative for replacement labels.
!WARNING
FAILURE OR IMPROPER SELECTION OR IMPROPER USE OF
THE PRODUCTS AND/OR SYSTEMS DESCRIBED HEREIN OR
RELATED ITEMS CAN CAUSE DEATH, PERSONAL INJURY AND
PROPERTY DAMAGE.
This document and other information from Parker Hannifin Corporation,
its subsidiaries and authorized distributors provide product and/or
system options for further investigation by users having technical
expertise. It is important that you analyze all aspects of your application,
including consequences of any failure and review the information
concerning the product or systems in the current product catalog. Due
to the variety of operating conditions and applications for these products
or systems, the user, through its own analysis and testing, is solely
responsible for making the final selection of the products and systems
and assuring that all performance, safety and warning requirements
of the application are met.
The products described herein, including without limitation, product
features, specifications, designs, availability and pricing, are subject
to change by Parker Hannifin Corporation and its subsidiaries at any
time without notice.
EXTRA COPIES OF THESE INSTRUCTIONS ARE AVAILABLE FOR
INCLUSION IN EQUIPMENT / MAINTENANCE MANUALS THAT UTILIZE
THESE PRODUCTS. CONTACT YOUR LOCAL REPRESENTATIVE.
Introduction
Follow these instructions when installing, operating, or servicing
the product.
Application Limits
These products are intended for use in general purpose
compressed air systems only.
Operating Pressure:
kPa PSIG bar
Maximum Inlet Pressure 2068 300 21.0
Operating Temperature Range: 4°C to 66°C (40°F to 150°F)
ANSI Symbols
Installation
1. The regulator should be installed with reasonable
accessibility for service whenever possible - repair service
kits are available. Keep pipe and tubing lengths to a
minimum with inside clean and free of dirt and chips. Pipe
joint compound should be used sparingly and applied only
to the male pipe - never into the female port. Do not use
PTFE tape to seal pipe joints - pieces have a tendency to
break off and lodge inside unit, possibly causing
malfunction.
2. Install regulator so that air flow is in the direction of arrow.
Installation must be upstream (high pressure) side and as
close to the devices it is to service (valve, cylinder, tool,
etc.) as possible. Mounting may be in any position.
3. Gauge ports are located on both sides of the regulator
body for your convenience. It is necessary to install a
gauge or pipe plugs into each port during installation.
4. For protection against rust, pipe scale, and other foreign
matter, install a filter on the upstream (high pressure) side
as close to the regulator as possible.
Operation
1. Before turning on the air supply:
1A. On PR364, disengage the adjusting knob by pulling upward.
Turn adjusting knob counterclockwise until the compression
is released from the pressure control spring.
1B. On PR10, push down on the adjusting knob while turning
knob counterclockwise until the compression is released
from the pressure control spring. (Knob is locked when
up.)
2. Then turn on air supply and adjust regulator to desired
secondary pressure by turning adjusting knob clockwise.
This permits pressure to build up slowly, preventing any
unexpected operation of the valve, cylinders, tools, etc.,
attached to the line. Adjustment to desired secondary
pressure can be made only with primary pressure applied
to the regulator.
3. To decrease regulator pressure setting, always reset from
a pressure lower than the final setting desired. For example,
lowering the secondary pressure from 550 to 410 kPa (80
to 60 psig) is best accomplished by dropping the secondary
pressure to 350 kPa (50 psig), then adjusting upward to
410 kPa (60 psig).
!
WARNING
Product rupture can cause serious injury.
Do not connect regulator to bottled gas.
Do not exceed maximum primary pressure rating.
➤
➤
➤
➤
➤
➤
Relieving Regulator
Adjustable
Non-Relieving Regulator
Adjustable

Knob
Adjusting Screw
Drive Nut
Control Spring
Spring,
Poppet Return
O-Ring,
Bottom Cap
O-Ring,
Vent Seal
Diaphragm Assembly
(Includes Upper Diaphragm Plate
& Lower Diaphragm Plate
Bottom Cap
Torque:
3.5 to 5.1 Nm (35 to 45 in.lb.)
Bottom Cap
Torque:
3.5 to 5.1 Nm (35 to 45 in.lb.)
Poppet
Assembly
Body
Knob
Adjusting Screw
Drive Nut
Control Spring
Spring,
Poppet Return
O-Ring,
Bottom Cap
Diaphragm Assembly
(Includes Upper Diaphragm Plate
& Lower Diaphragm Plate
Poppet
Assembly
Body
Bonnet - Torque:
4.5 to 5.6 Nm (60 to 70 in.lb.)
Bonnet - Torque:
13.6 to 15.8 Nm (120 to 140 in.lb.
)
Service
!
CAUTION:
SHUT OFF AIR SUPPLY and exhaust the primary and
secondary pressure before disassembling regulator unit.
(Turning the knob counterclockwise reduces regulator’s
setting, but does not vent downstream pressure on non-
relieving regulators.)
!
CAUTION:
Lubricate parts with a mineral based grease / oil or silicone
grease. DO NOT use synthetic grease / oils such as esters.
A. Servicing the Bonnet and Diaphragm Assembly-
1A. On PR364, disengage the adjusting knob by pulling upward.
Turn adjusting knob counterclockwise until the compression
is released from the pressure control spring.
1B. On PR10, push down on the adjusting knob while turning
knob counterclockwise until the compression is released
from the pressure control spring. (Knob is locked when
up.)
2. Unscrew the threaded bonnet assembly. Next, disassemble,
clean, and carefully inspect parts for wear and/or damage.
If replacement is necessary, use parts from service kits.
3. Install diaphragm assembly into body. Then install bonnet
assembly to body. See Figure 1 for torque value.
B. Servicing the Poppet Assembly-
1. Exhaust system air pressure as previously described. Then
remove bottom cap by unscrewing it from body. Next,
remove cap and o-ring, spring and poppet assembly.
2.
Next, clean, and carefully inspect parts for wear and/or
damage. If replacement is necessary, use parts from
service kits.
1/4" PR364 & 1/2" PR10 Regulators 3R100P
3. Lubricate o-ring and sliding surfaces using grease supplied
with service kit.
4. Lubricate cap’s o-ring and install it in o-ring groove on cap.
Then screw cap into body until the cap bottoms out in
body. See Figure 1 for torque value.
5. Turn on air supply and adjust to desired secondary pressure
as described in the Operation section.
Turn on air pressure and check regulator for leakage. If leakage
occurs, DO NOT OPERATE — conduct repairs again.
If you have questions concerning how to service this unit, contact
your local authorized dealer or your customer service
representative.
Service Kits Available
Description PR364 (1/4") PR10 (1/2")
Bonnet Assembly PCKR364YSS PCKR10YSS
Gauges 274Z160SS 275Y160SS
Panel Mount Nut PR05X51SS PR10X51SS
Regulator Repair Kit
(Relieving) PRK364YSS PRKR10YSS
Regulator Repair Kit
(Non-Relieving) PRK364KYSS PRKR10KYSS
Spring, 0-25 PSIG SPR-375-2-SS —
Spring, 0-60 PSIG SPR-376-1-SS SPR-388-1-SS
Spring, 0-125 PSIG SPR-377-1-SS SPR-389-1-SS
Spring, 0-250 PSIG — SPR-390-1-SS
PR364 Regulator
(Non-Relieving Shown)
PR10 Regulator
(Relieving Shown)
Figure 1
Lightly grease with provided lubricant.
Inspect for nicks, scratches, and surface imperfections. If present,
reduced service life is probable and future replacement should
be planned.
Clean with lint-free cloth.
This manual suits for next models
1
Other Parker Pneumatic Controllers manuals
Popular Controllers manuals by other brands

LEGRAND
LEGRAND Adorne LC7001 user guide

Athena
Athena S Series instruction manual

National Instruments
National Instruments Network Adapter NI PXIe-6672 installation guide

I2R Tech Lighting Solutions
I2R Tech Lighting Solutions Moving Head Controller 2.0 user manual

M-Audio
M-Audio Keystation manual

MIKRODEV
MIKRODEV MP110 Series Hardware manual

Woodward
Woodward 723PLUS Installation and operation manual

Beckett
Beckett AquaSmart Quick Tutorial

Schischek
Schischek RedMax BF Series quick start guide

Inovance
Inovance MD500 Series user guide

Snell Advanced Media
Snell Advanced Media 2460 user manual

Siemens
Siemens BACnet PTEC Dual Duct 2 AVS installation instructions