+3V PS Blue. Steady glow indicates 3V power supply is
OK. O󰀨 indicates no power.
+5V PS Blue. Steady glow indicates 5V power supply is
OK. O󰀨 indicates no power.
DMX INPUT Amber. Steady glow indicates port latched to ac-
tive DMX source. Blinking indicates no incoming
DMX signal. O󰀨 indicates Port is Disabled.
DMX OUTPUT Green. Steady glow indicates port is transmit-
ting DMX. Blinking indicates no DMX output. O󰀨
indicates Port is Disabled.
NETWORK
LINK/ACT
Green. Flickering glow means active Ethernet
network link. O󰀨 indicates no network link.
Pathport DIN-Mount DMX/RDM Ethernet Gateway
PWPP DIN P1 Manual
03/08/22
The Pathport® DIN-mount 1-Port Gateway (PWPP DIN P1)
provides the full functionality of other Pathport gateways
in a compact, DIN-rail mountable form factor.
System integrators can now easily put a fully customized
universe of DMX where it’s needed.
Ideal for use in NEMA enclosures. Fully compatible with
DIN interfaces (PWINF).
The Pathport PWPP DIN P1 features terminal strips that can
be removed from the card to facilitate easy wiring installation or
replacement. Make the following connections, WITH THE POWER
TURNED OFF.
POWER
The PWPP DIN P1 is designed to run on either Power-over-Ethernet
(PoE), or on an auxiliary power supply providing between 18 and 48
volts DC. The gateway is Class 1 PoE and will draw up to 4 Watts.
If an auxiliary supply is used, observe the correct polarity when
connecting V+ and V-. A second set of terminals are provided so
power may be daisy-chained to other cards. The earth ground
terminal can be connected to the enclosure’s chassis or electrical
ground terminal to improve EMC compliance.
DMX512
DMX connections consist of a shield and data pair. Connect DATA+
and DATA- to D1+ and D1-. Observe the same polarity convention
throughout the system. Connect the cable shield or common to the
SHLD COM terminal.
NETWORK
All network wiring should follow standard Ethernet rules and be
installed by a qualied person. As part of the installation, all wiring
should be certied under the TIA/EIA-568 standard.
OVERVIEW
CONNECTIONS
STATUS INDICATORS
NC
NC
D1+
COM
SHLD
D1-
DMX IN/OUT
V+
V-
GND
EARTH
V-
DMX INPUT
DMX OUTPUT
AUX POWER IN
18 - 48 VDC
MAX 3 WATTS
V+
+3V PS
NET LINK/ACT
+5V PS
ON
1 2 34
ETHERNET
802.3af POE
1
2
3
4
UNIVERSE SELECT
ALL OFF FOR
SOFT CONFIG
Female RJ45
Ethernet Connector
Universe
Select
LED Indicators
Power In (If PoE not in use):
18-48VDC, 4W Supply required.
Use PWPWR DIN TERM 100W 48VDC
or equal.
Connect Earth ground to to improve
EMC compliance
Fastening mechanism designed
for 35 x 7.5mm DIN rail
DMX512 Input/Output DIN rail release lever
Use large flat-head screwdriver or
similar tool to gently pry lever away
from DIN rail to release
Pathport DIN-Mount DMX/RDM Ethernet Gateway
PWPP DIN P1 Manual
03/08/22
© 2022 Acuity Brands, Inc. • One Lithonia Way, Conyers GA 30012
Pathway Connectivity | #103 - 1439 17th Ave SE Calgary, AB Canada T2G 1J9
Phone: + 1 866 617 3074 www.pathwayconnect.com
INSTALLATION
• Disconnect all power before proceeding with installation.
• Securely mount DIN rail (if not already installed in an enclosure).
To mount the PWPP DIN P1, hook the upper slots on the back
of the plastic extrusion to the DIN rail and then gently but rmly
press on the bottom front corners of the extrusion to snap the
module onto the rail. DO NOT press directly on the PCB card
itself.
• If the PWPP DIN P1 is using an auxiliary power supply, connect
the power IN terminal block, after checking that polarity is being
observed. The earth ground terminal must be connected to the
enclosure’s chassis or electrical ground terminal to ensure EMC
compliance. Restore power and the card will boot up.
• Attach the network cable to the RJ45 connector. Because good
wiring practice requires building wire to terminate with a female
connector, typically a short (12”/30cm) male-to-male jumper is
used. If PoE is being used, the card will boot up. Both auxiliary
power and PoE may be connected simultaneously without
damaging the PWPP DIN P1.
• The system is now ready for testing.
• To remove the PWPP DIN P1 from the DIN rail, use a athead
screwdriver to gently pry the hooked foot on the end caps of the
device away from the DIN rail. The corner of the device should life
free; repeat at the other side and unhook the device from the rail.
A large number of parameters may be customized for the PWPP
DIN P1, including: port direction, output channel patch, input
universe number, transmit and receive protocols and DMX speed.
Network properties such as IP address and subnet mask are also
customizable by the user.
Detailed gateway configuration and overall network system
management are done using Pathscape software, which is available
for download from www.PathwayConnect.com
Please refer to the Pathscape manual for information on
conguring these additional properties.
PATHSCAPE CONFIGURATION
The PWPP DIN P1 ships as a DMX output gateway with Pathway
ssACN enabled.
The following Ethernet receive protocols are unsecured and are
NOT ENABLED by default: Pathport, Strand Shownet, ETC Net2,
E1.31 streaming ACN and Art-Net.
Before conguring and using the PWPP DIN P1, you must add it
to a Security Domain using Pathscape.
To use the other listed unsecured protocols, you must
use Pathscape and enable the device property ALLOW
UNSECURED RX (see below).
DEFAULT SETTINGS
Due to new cybersecurity laws, all Pathport devices shipped after
January 1, 2020 have security properties enabled. This means
that by default, the device is not set up to receive unsecured
network protocols such as Art-Net, E1.31 sACN, ShowNet, NET2
or Pathport Protocol.
You must add the Pathport to a Security Domain using
Pathscape before conguration and use.
Pathway ssACN (Secure sACN) is enabled by default.
To use the above unsecured protocols, open Pathscape. In
the Pathport base device properties, under the Network DMX
Receive Protocols section, click the Allow Unsecured RX
checkbox.
Once checked, you may select the network protocol(s) to receive.
For further information, please see the following sections in the
Pathscape manual: Security, Pathport Properties > Network
DMX Receive Protocols .
IMPORTANT - UNSCURED NETWORK PROTOCOLS
Pathport DIN-Mount DMX/RDM Ethernet Gateway
PWPP DIN P1 Manual
03/08/22
© 2022 Acuity Brands, Inc. • One Lithonia Way, Conyers GA 30012
Pathway Connectivity | #103 - 1439 17th Ave SE Calgary, AB Canada T2G 1J9
Phone: + 1 866 617 3074 www.pathwayconnect.com
• PoE-powered Class 1 device, 4W max power consumption
• Auxiliary input voltage, 18-48V
• 60V protection on each port
• 10Mb TCP/IP connection
• ANSI E1.11 DMX512-A R2013
• ANSI E1.20 RDM(2010) - Remote Device Management
• ANSI E1.31 sACN - Streaming ACN, Art-Net, Strand ShowNet,
Pathway ssACN
• ANSI E1.33 RDMnet - RDM over IP
• IEEE 802.3af Power-over-Ethernet
• Class 2 Low Voltage
• California Title 1.81.26, Security of Connected Devices
ELECTRICAL INFORMATION
COMPLIANCE
• 4.5”W x 4”H x 1.9”D (113mm x 103mm x 48mm)
• 0.4 lbs (0.18 kg)
• Operating Conditions: 14°F-113°F (-10°C to 45°C); 5-95% relative
humidity, non-condensing
PHYSICAL

Other pathway Gateway manuals

pathway Pathport PWPP HH P1 XLR5F User manual

pathway

pathway Pathport PWPP HH P1 XLR5F User manual

pathway Pathport PWPP DIN P2 User manual

pathway

pathway Pathport PWPP DIN P2 User manual

pathway Pathport PWPP WM P2 User manual

pathway

pathway Pathport PWPP WM P2 User manual

pathway Vignette PWGW Series User manual

pathway

pathway Vignette PWGW Series User manual

pathway pathport quattro User manual

pathway

pathway pathport quattro User manual

Popular Gateway manuals by other brands

Salus SG888ZB Installation & user guide

Salus

Salus SG888ZB Installation & user guide

TopJet Alert Ethernet Gateway quick start guide

TopJet Alert

TopJet Alert Ethernet Gateway quick start guide

Gigalink GL-VP-6222 user manual

Gigalink

Gigalink GL-VP-6222 user manual

MSA fieldserver EZ Series operating manual

MSA

MSA fieldserver EZ Series operating manual

Philips Dynalite DDNG485 installation instructions

Philips

Philips Dynalite DDNG485 installation instructions

HARTING MICA IO-Link Series user guide

HARTING

HARTING MICA IO-Link Series user guide

RTA 460PSBM-NNA1 Product user guide

RTA

RTA 460PSBM-NNA1 Product user guide

RTA 460MSMRS-N2E Product user guide

RTA

RTA 460MSMRS-N2E Product user guide

Comcast XFINITY user guide

Comcast

Comcast XFINITY user guide

Magnum First M9-EBOX Setup manual

Magnum First

Magnum First M9-EBOX Setup manual

OTE Speedport Entry 2i Maintenance Management Guide

OTE

OTE Speedport Entry 2i Maintenance Management Guide

ActionTec Wireless-Ready DSL Gateway user manual

ActionTec

ActionTec Wireless-Ready DSL Gateway user manual

Dension Gateway Lite user manual

Dension

Dension Gateway Lite user manual

Fiberme FAG410X Configuring and Installing

Fiberme

Fiberme FAG410X Configuring and Installing

Wiznet WIZ6000 user manual

Wiznet

Wiznet WIZ6000 user manual

ESD CAN-PN/2 manual

ESD

ESD CAN-PN/2 manual

Honeywell NS1 installation guide

Honeywell

Honeywell NS1 installation guide

VOPtel VG2020 user guide

VOPtel

VOPtel VG2020 user guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.