Patton electronics ipRocketLink 3086FR User manual

ipRocketLink™ Model 3086FR
G.SHDSL Frame Relay over
ATM IAD
Quick Start Guide
Important
—This is a Class A device and is intended for use in a light industrial environment. It is not
intended nor approved for use in an industrial or residential environment.
Part Number: 07M3086FR-QS, Rev. B
Revised: February 15, 2012
Sales Office: +1 (301) 975-1000
Technical Support: +1 (301) 975-1007
E-mail: support@patton.com
WWW: www.patton.com

2ipRocketLink 3086FR Quick Start Guide
1.0 Power up the IAD
Your IAD comes with one of the following power supply options:
•
Internal AC power supply with detachable power cord
•
External AC adaptor with detachable power cord
•
Internal DC power supply—no power accessories are included
1.1 Models with internal AC power supply
1. Insert the female end of the AC power cord into the internal power supply connector.
2. Connect the male end of the power cord into an AC power outlet (100–240 VAC).
1.2 Models with external AC adaptor
1. Connect female plug of the AC power cord to the AC adaptor provided.
• This device contains no user serviceable parts. The equipment shall be
returned to Patton Electronics for repairs, or repaired by qualified
service personnel.
• Mains Voltage: Do not open the case the when the power cord is
attached. Line voltages are present within the power supply when
the power cords are connected. The mains outlet that is utilized to
power the devise shall be within 10 feet (3 meters) of the device,
shall be easily accessible, and protected by a circuit breaker.
• For AC powered units, ensure that the power cable used meets all
applicable standards for the country in which it is to be installed, and
that it is connected to a wall outlet which has earth ground.
• For units with an external power adapter, the adapter shall be a
listed Limited Power Source.
• Hazardous network voltages are present in WAN ports regardless of
whether power to the unit is ON or OFF. To avoid electric shock, use
caution when near WAN ports. When detaching the cables, detach the
end away from the device first.
• Do not work on the system or connect or disconnect cables during
periods of lightning activity.
The interconnecting cables shall be acceptable for external use and shall be rated for
the proper application with respect to voltage, current, anticipated temperature, flam-
mability, and mechanical serviceability.
WARNING
CAUTION

ipRocketLink 3086FR Quick Start Guide 3
2. Connect the barrel-type connector of the AC adaptor to the barrel-type power jack on the ipRocketLink.
3. Insert the male plug of the AC power cord into an AC power outlet (100–240 VAC)
.
1.3 Models with internal DC power supply
1. Strip insulation 1/4-inch from the electrical wires that will connect the DC power source to
the ipRocketLink.
2. Connect the ground terminal from the power source to the ground terminal on the ipRocketLink.
3. Connect the negative (-) terminal from the power source with to the negative (-) terminal on
the ipRocketLink.
4. Connect the positive (+) terminal from the power source with to the positive (+) terminal on
the ipRocketLink.
1.4 Power-up indication
The Power LED blinks as the ipRocketLink is powering up. When the Power LED stops blinking and remains lit,
the ipRocketLink is ready for you to configure.
2.0 Configure the IP address
The ipRocketLink is shipped with a factory-configured IP address assigned to the Ethernet LAN port (green out-
line). The address is 192.168.200.10/24. In most cases, you must change the address to be on the same
subnet as your PC, as described in the procedures below. If you are not sure which IP address to use for your
installation, contact your network administrator.
2.1 Connect a PC and log in
1. Using the included combination RS232/Ethernet cable and DB9-RJ45 adapter, connect a PC’s serial port
to the ipRocketLink’s Console port (see figure 1).
Figure 1. Connecting ipRocketLink to the PC’s serial port
Connect to Console port
Serial port
PC with
terminal emulator
Power
Console
ipRocketLink
G.SHDSL Integrated Access Device
Model 3086
Link
TD
RD
CTS
DTR
WAN Sync Serial
Link
100M
TxRx
Ethernet
NS
ER
TM
Status
- 511E
- Normal
- 511
Test Modes
Local -
Normal -
Remote -

4ipRocketLink 3086FR Quick Start Guide
2. Start a HyperTerminal session on the PC using the settings:
9600 bps, 8 data bits, 1 stop bit, no parity, no flow control
3. Log in to the ipRocketLink using the factory-default login and password:
Login: superuser
Password: superuser
Login successful
2.2 Modify the IP address
1. Display current IP interface settings for the ipRocketLink Ethernet LAN port.
fi
ip list interfaces <enter>
IP Interfaces:
ID | Name | IP Address | DHCP | Transport
---|------|----------------|----------|--------------
1 | ip1 | 192.168.200.10 | disabled | <bridge>
----------------------------------------------------
2. Modify the IP address for the LAN port according to your network requirements.
fi
ip set interface ip1 ipaddress 10.10.10.5 255.255.255.0
Note The above IP address is only an example. You must choose an IP address on the same subnet as
your PC.
3. Verify the new address is correct and save it in system boot memory.
fi
ip list interfaces <enter>
fi
system config save <enter>
fi
3.0 Connect to the local IP network
Now you can connect the ipRocketLink to your local IP network and complete the remaining configuration from
your PC using a standard web browser.
Connect the ipRocketLink’s Ethernet port (green) to the same Ethernet segment as your PC (see figure 2). The
front-panel Ethernet Link LED should turn on. If it does not, press the rear-panel MDI-X switch so that the Ethernet
Link LED illuminates.

ipRocketLink 3086FR Quick Start Guide 5
Figure 2. Connecting the ipRocketLink to the local IP network (Model 3086FR/RIC shown)
You can check the connection with the ping command. For example shown in figure 2, you would ping
10.10.10.5 from a PC on the IP network.
4.0 Log onto the web management interface
You will now access the web management graphical user interface (GUI) to configure the ipRocketLink using a
standard web browser (such as Internet Explorer or Netscape browser).
1. At your PC, open a web browser and enter the IP address you assigned to the ipRocketLink’s Ethernet LAN
port in step 2 of section 2.2 “Modify the IP address” on page 4.
2. Log in to the web management home page using the username superuser and the password superuser.
Figure 3. ipRocketLink web management home page
5.0 Connect the G.SHDSL Port
1. Obtain single-twisted-pair cable with an RJ-11 plug connector at each end.
Crossover
10/100
Ethernet DSL
Power MDI-X
Connect to Ethernet port
Ethernet port
MDI-X switch
PC
Interface Port

6ipRocketLink 3086FR Quick Start Guide
2. Plug one end of the cable into the (yellow) RJ-11socket (labelled DSL) on the ipRocketLink Integrated
Access Device.
3. Plug the other end of the cable into the RJ-11 wall socket that provides your G.SHDSL service.
4. When a DSL link is established the front-panel WAN LINK LED will turn on.
6.0 Connect the serial port
Your ipRocketLink is equipped with one of the following serial WAN ports for connection to an NTU:
•
V.35 (M/34 or DB-25)—Model 3086FR/RIC, Model 3086FR/RICA
•
X.21 (DB-15)—Model 3086FR/RID
•
T1/E1(RJ-48C and dual BNC)—Model 3086FR/RIK, Model 3086FR/RIT
Connect the serial cable to the ipRocketLink serial port as follows:
1. Attach the male connector of the serial cable to the female serial connector on the IAD.
2. Attach the other end of the cable to the serial connector on local serial NTU.
Note The IAD’s V.35 interface is wired as a DCE. No DTE configuration is possible. If you are directly connect-
ing the IAD’s V.35 interface to third-party equipment that cannot be configured as a DTE, you must use
a tail-circuit cable. You can purchase a tail-circuit cable from a datacom-supply vendor. A tail-circuit
cable will cross-over the necessary V.35 signals so that the two DCE interfaces can communicate.
Note The IAD’s X.21 interface is wired as a DCE. No DTE configuration is possible. The IAD’s X.21 interface
requires a cable with a male DB-15 connector.
7.0 Additional Information
For detailed information about configuring and operating guidance, set up procedures, and troubleshooting,
refer to the ipRocketLink 3086FR User Guide available online at www.patton.com/manuals/
3086FR.pdf.
A.0 Customer and Technical Support
Toll-Free VoIP support: call sip:support@patton.com with a VoIP SIP phone
Online support: www.patton.com
E-mail support: support@patton.com—answered within 1 business day
Telephone support:
•
Standard: +1 (301) 975-1007 (USA), Monday–Friday: 8:00 am to 5:00 pm EST (1300 to
2200 UTC/GMT)

ipRocketLink 3086FR Quick Start Guide 7
•
Alternate: +41 (0)31 985 25 55 (Switzerland), Monday–Friday: 8:00 am to 5:00 pm CET (0900 to 1800
UTC/GMT)
Fax: +1 (253) 663-5693 (USA) or +41 (0)31 985 25 26 (Switzerland)
B.0 Compliance Information
B.1 Compliance
EMC:
•
FCC Part 15, Class A
•
EN55022, Class A
•
EN55024
Safety:
•
UL60950-1/CSA C22.2 No. 60950-1
•
IEC/EN 60950-1
•
AS/NZS 60950-1
PSTN Regulatory:
•
FCC Part 68
•
CS-03
•
AS/ACIF S043
B.2 Radio and TV Interference (FCC Part 15)
This equipment generates and uses radio frequency energy, and if not installed and used properly—that is, in
strict accordance with the manufacturer's instructions—may cause interference to radio and television recep-
tion. This equipment has been tested and found to comply with the limits for a Class A computing device in accor-
dance with the specifications in Subpart B of Part 15 of FCC rules, which are designed to provide reasonable
protection from such interference in a commercial installation. However, there is no guarantee that interference
will not occur in a particular installation. If the equipment causes interference to radio or television reception,
which can be determined by disconnecting the cables, try to correct the interference by one or more of the fol-
lowing measures: moving the computing equipment away from the receiver, re-orienting the receiving antenna,
and/or plugging the receiving equipment into a different AC outlet (such that the computing equipment and
receiver are on different branches).

8ipRocketLink 3086FR Quick Start Guide
B.3 CE Declaration of Conformity
Product Description: ipRocketLink 3086FR
We certify that the apparatus identified in this document conforms to the requirements of Council Directive
1999/5/EC on the approximation of the laws of the member states relating to Radio and Telecommunication
Terminal Equipment and the mutual recognition of their conformity.
The safety advice in the documentation accompanying this product shall be obeyed. The conformity to the above
directive is indicated by the CE sign on the device.
The signed Declaration of Conformity can be downloaded from www.patton.com/certifications/.
B.4 Authorized European Representative
D R M Green
European Compliance Services Limited.
Avalon House, Marcham Road
Abingdon,
Oxon OX14 1UD, UK
B.5 FCC Part 68 (ACTA) Statement
This equipment complies with Part 68 of FCC rules and the requirements adopted by ACTA. On the bottom side of
this equipment is a label that contains—among other information—a product identifier in the format US:
AAAEQ##TXXXX. If requested, this number must be provided to the telephone company.
The method used to connect this equipment to the premises wiring and telephone network must comply with the
applicable FCC Part 68 rules and requirements adopted by the ACTA.
If this equipment causes harm to the telephone network, the telephone company will notify you in advance that
temporary discontinuance of service may be required. But if advance notice isn’t practical, the telephone com-
pany will notify the customer as soon as possible. Also, you will be advised of your right to file a complaint with
the FCC if you believe it is necessary.
The telephone company may make changes in its facilities, equipment, operations or procedures that could
affect the operation of the equipment. If this happens, the telephone company will provide advance notice in
order for you to make necessary modifications to maintain uninterrupted service.
If trouble is experienced with this equipment, for repair or warranty information, please contact our company. If
the equipment is causing harm to the telephone network, the telephone company may request that you discon-
nect the equipment until the problem is resolved.
Connection to party line service is subject to state tariffs. Contact the state public utility commission, public ser-
vice commission or corporation commission for information.
The safety advises in the documentation accompanying the products shall be obeyed. The
conformity to the above directive is indicated by the CE sign on the device.

ipRocketLink 3086FR Quick Start Guide 9
B.6 Industry Canada Notice
This equipment meets the applicable Industry Canada Terminal Equipment Technical Specifications. This is con-
firmed by the registration number. The abbreviation, IC, before the registration number signifies that registra-
tion was performed based on a Declaration of Conformity indicating that Industry Canada technical specifications
were met. It does not imply that Industry Canada approved the equipment.
This Declaration of Conformity means that the equipment meets certain telecommunications network protective,
operational and safety requirements. The Department does not guarantee the equipment will operate to the
user's satisfaction. Before installing this equipment, users should ensure that it is permissible to be connected to
the facilities of the local telecommunications company. The equipment must also be installed using an acceptable
method of connection. In some cases, the company's inside wiring associated with a single line individual service
may be extended by means of a certified connector assembly (telephone extension cord). The customer should
be aware that compliance with the above condition may not prevent degradation of service in some situations.
Repairs to some certified equipment should be made by an authorized maintenance facility designated by the
supplier. Any repairs or alterations made by the user to this equipment, or equipment malfunctions, may give
the telecommunications company cause to request the user to disconnect the equipment. Users should ensure for
their own protection that the ground connections of the power utility, telephone lines and internal metallic water
pipe system, are connected together. This protection may be particularly important in rural areas.

10 ipRocketLink 3086FR Quick Start Guide
Copyright statement
Copyright © 2012, Patton Electronics Company. All rights reserved.
The information in this document is subject to change without notice. Patton Electronics assumes no
liability for errors that may appear in this document.
Trademarks statement
The term ipRocketLink is a trademark of Patton Electronics Company. All other trademarks presented in this doc-
ument are the property of their respective owners.
Warranty, Trademark, & Compliance Information
For warranty, trademark and compliance information, refer to the ipRocketLink 3086FR User Guide located
online at www.patton.com/manuals.
In accordance with the requirements of council directive 2002/96/EC on Waste of
Electrical and Electronic Equipment (WEEE), ensure that at end-of-life you separate
this product from other waste and scrap and deliver to the WEEE collection system in
your country for recycling.

ipRocketLink 3086FR Quick Start Guide 11
NOTES
____________________________________________________________________
____________________________________________________________________
____________________________________________________________________
____________________________________________________________________
____________________________________________________________________
____________________________________________________________________
____________________________________________________________________
____________________________________________________________________
____________________________________________________________________
____________________________________________________________________
____________________________________________________________________
____________________________________________________________________
____________________________________________________________________
____________________________________________________________________
____________________________________________________________________
____________________________________________________________________

12 ipRocketLink 3086FR Quick Start Guide
NOTES
____________________________________________________________________
____________________________________________________________________
____________________________________________________________________
____________________________________________________________________
____________________________________________________________________
____________________________________________________________________
____________________________________________________________________
____________________________________________________________________
____________________________________________________________________
____________________________________________________________________
____________________________________________________________________
____________________________________________________________________
____________________________________________________________________
____________________________________________________________________
____________________________________________________________________
____________________________________________________________________
Other manuals for ipRocketLink 3086FR
2
Table of contents
Other Patton electronics Network Accessories manuals

Patton electronics
Patton electronics Patton SmartNode 2400 Series User manual

Patton electronics
Patton electronics 2888 User manual

Patton electronics
Patton electronics ipRocketLink 3086FR User manual

Patton electronics
Patton electronics 2701RC User manual

Patton electronics
Patton electronics ipRocketLink 3086FR User manual