manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. PCB Piezotronics
  6. •
  7. Accessories
  8. •
  9. PCB Piezotronics 401B04 User manual

PCB Piezotronics 401B04 User manual

Other PCB Piezotronics Accessories manuals

PCB Piezotronics 106B51 User manual

PCB Piezotronics

PCB Piezotronics 106B51 User manual

PCB Piezotronics 117B227 User manual

PCB Piezotronics

PCB Piezotronics 117B227 User manual

PCB Piezotronics S111A22 User manual

PCB Piezotronics

PCB Piezotronics S111A22 User manual

PCB Piezotronics M224C User manual

PCB Piezotronics

PCB Piezotronics M224C User manual

PCB Piezotronics 352M208 User manual

PCB Piezotronics

PCB Piezotronics 352M208 User manual

PCB Piezotronics 208A11 User manual

PCB Piezotronics

PCB Piezotronics 208A11 User manual

PCB Piezotronics 208C01 User manual

PCB Piezotronics

PCB Piezotronics 208C01 User manual

PCB Piezotronics 350C04 User manual

PCB Piezotronics

PCB Piezotronics 350C04 User manual

PCB Piezotronics 351B04 User manual

PCB Piezotronics

PCB Piezotronics 351B04 User manual

PCB Piezotronics 8161-111A User manual

PCB Piezotronics

PCB Piezotronics 8161-111A User manual

PCB Piezotronics ICP 320C33 User manual

PCB Piezotronics

PCB Piezotronics ICP 320C33 User manual

PCB Piezotronics 208C04 User manual

PCB Piezotronics

PCB Piezotronics 208C04 User manual

PCB Piezotronics IMI Sensors 640 B7 Series User manual

PCB Piezotronics

PCB Piezotronics IMI Sensors 640 B7 Series User manual

PCB Piezotronics M209C12 User manual

PCB Piezotronics

PCB Piezotronics M209C12 User manual

PCB Piezotronics IMI Sensors 080A133 User manual

PCB Piezotronics

PCB Piezotronics IMI Sensors 080A133 User manual

PCB Piezotronics IMI Sensors 66333PPZ2 User manual

PCB Piezotronics

PCB Piezotronics IMI Sensors 66333PPZ2 User manual

PCB Piezotronics IMI SENSORS EXM641B02 User manual

PCB Piezotronics

PCB Piezotronics IMI SENSORS EXM641B02 User manual

PCB Piezotronics ICP 137B23A User manual

PCB Piezotronics

PCB Piezotronics ICP 137B23A User manual

PCB Piezotronics HT356A66 User manual

PCB Piezotronics

PCB Piezotronics HT356A66 User manual

PCB Piezotronics 356B08 User manual

PCB Piezotronics

PCB Piezotronics 356B08 User manual

PCB Piezotronics 208C01 User manual

PCB Piezotronics

PCB Piezotronics 208C01 User manual

PCB Piezotronics 010M144 User manual

PCB Piezotronics

PCB Piezotronics 010M144 User manual

PCB Piezotronics 137B21B User manual

PCB Piezotronics

PCB Piezotronics 137B21B User manual

PCB Piezotronics S101A06 User manual

PCB Piezotronics

PCB Piezotronics S101A06 User manual

Popular Accessories manuals by other brands

Quincy lab 140AE-1 operating manual

Quincy lab

Quincy lab 140AE-1 operating manual

HomePro ZIR000 user manual

HomePro

HomePro ZIR000 user manual

DOL 20SCR Technical user guide

DOL

DOL 20SCR Technical user guide

RAB Smart Task installation manual

RAB

RAB Smart Task installation manual

Kemppi KMS 300 quick guide

Kemppi

Kemppi KMS 300 quick guide

Stearns 57,500 Series Installation and service instructions

Stearns

Stearns 57,500 Series Installation and service instructions

iGuzzini TWILIGHT COPENAGHEN manual

iGuzzini

iGuzzini TWILIGHT COPENAGHEN manual

Adelaide Annexe & Canvas Avan Deluxe installation guide

Adelaide Annexe & Canvas

Adelaide Annexe & Canvas Avan Deluxe installation guide

OHAUS 5000 instruction manual

OHAUS

OHAUS 5000 instruction manual

HOME8 WLS1300 quick start guide

HOME8

HOME8 WLS1300 quick start guide

MAXBOTIX MaxSonar quick start guide

MAXBOTIX

MAXBOTIX MaxSonar quick start guide

ioSmart iSmart56 Installation and user guide

ioSmart

ioSmart iSmart56 Installation and user guide

Focusrite Scarlett 18i8 user guide

Focusrite

Focusrite Scarlett 18i8 user guide

Velleman ED38105 user manual

Velleman

Velleman ED38105 user manual

JumpSport SkyBounce user manual

JumpSport

JumpSport SkyBounce user manual

Prima-Temp PRIYA Instructions for use

Prima-Temp

Prima-Temp PRIYA Instructions for use

Tefcold BC85I-BC85I W user manual

Tefcold

Tefcold BC85I-BC85I W user manual

Vaisala WMS302 user guide

Vaisala

Vaisala WMS302 user guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

Model 401B04
ICP® Source Follower
Installation and Operating Manual
For assistance with the operation of this product,
contact PCB Piezotronics, Inc.
Toll-free: 800-828-8840
24-hour SensorLine: 716-684-0001
Fax: 716-684-0987
E-mail: [email protected]
Web: www.pcb.com
Manual 21354 Rev E
ECN 50523
Repair and Maintenance
PCB guarantees Total Customer Satisfaction through its
“Lifetime Warranty Plus” on all Platinum Stock Products
sold by PCB and through its limited warranties on all other
PCB Stock, Standard and Special products. Due to the
sophisticated nature of our sensors and associated
instrumentation, field servicing and repair is not
recommended and, if attempted, will void the factory
warranty.
Beyond routine calibration and battery replacements
where applicable, our products require no user
maintenance. Clean electrical connectors, housings, and
mounting surfaces with solutions and techniques that will
not harm the material of construction. Observe caution
when using liquids near devices that are not hermetically
sealed. Such devices should only be wiped with a
dampened cloth—never saturated or submerged.
In the event that equipment becomes damaged or ceases
to operate, our Application Engineers are here to support
your troubleshooting efforts 24 hours a day, 7 days a
week. Call or email with model and serial number as well
as a brief description of the problem.
Calibration
Routine calibration of sensors and associated
instrumentation is necessary to maintain measurement
accuracy. We recommend calibrating on an annual basis,
after exposure to any extreme environmental influence,
or prior to any critical test.
PCB Piezotronics is an ISO-9001 certified company whose
calibration services are accredited by A2LA to ISO/IEC
17025, with full traceability to SI through N.I.S.T. In
addition to our standard calibration services, we also offer
specialized tests, including: sensitivity at elevated or
cryogenic temperatures, phase response, extended high
or low frequency response, extended range, leak testing,
hydrostatic pressure testing, and others. For more
information, contact your local PCB Piezotronics
distributor, sales representative, or factory customer
service representative.
Returning Equipment
If factory repair is required, our representatives will
provide you with a Return Material Authorization (RMA)
number, which we use to reference any information you
have already provided and expedite the repair process.
This number should be clearly marked on the outside of
all returned package(s) and on any packing list(s)
accompanying the shipment.
Contact Information
PCB Piezotronics, Inc.
3425 Walden Ave.
Depew, NY14043 USA
Toll-free: (800) 828-8840
24-hour SensorLine: (716) 684-0001
General inquiries: in[email protected]
Repair inquiries: rma@pcb.com
For a complete list of distributors, global offices and sales
representatives, visit our website, www.pcb.com.
Safety Considerations
This product is intended for use by qualified personnel
who recognize shock hazards and are familiar with the
precautions required to avoid injury. While our equipment
is designed with user safety in mind, the protection
provided by the equipment may be impaired if equipment
is used in a manner not specified by this manual.
Discontinue use and contact our 24-Hour Sensorline if:
Assistance is needed to safely operate equipment
Damage is visible or suspected
Equipment fails or malfunctions
For complete equipment ratings, refer to the enclosed
specification sheet for your product.
Definition of Terms and Symbols
The following symbols may be used in this manual:
DANGER
Indicates an immediate hazardous
situation, which, if not avoided, may
result in death or serious injury.
Manual 21354 Rev E
ECN 50523
CAUTION
Refers to hazards that could damage
the instrument.
NOTE
Indicates tips, recommendations and
important information. The notes
simplify processes and contain
additional information on particular
operating steps.
The following symbols may be found on the equipment
described in this manual:
This symbol on the unit indicates that
high voltage may be present. Use
standard safety precautions to avoid
personal contact with this voltage.
This symbol on the unit indicates that
the user should refer to the operating
instructions located in the manual.
This symbol indicates safety, earth
ground.
Manual 21354 Rev E
ECN 50523
PCB工业监视和测量设备 - 中国RoHS2公布表
PCB Industrial Monitoring and Measuring Equipment - China RoHS 2 Disclosure Table
部件名称
有害物质
铅(Pb)
汞
(Hg)
镉
(Cd)
六价铬(Cr(VI))
多溴联苯 (PBB)
多溴二苯醚(PBDE)
住房
O
O
O
O
O
O
PCB板
X
O
O
O
O
O
电气连接器
O
O
O
O
O
O
压电晶体
X
O
O
O
O
O
环氧
O
O
O
O
O
O
铁氟龙
O
O
O
O
O
O
电子
O
O
O
O
O
O
厚膜基板
O
O
X
O
O
O
电线
O
O
O
O
O
O
电缆
X
O
O
O
O
O
塑料
O
O
O
O
O
O
焊接
X
O
O
O
O
O
铜合金/黄铜
X
O
O
O
O
O
本表格依据 SJ/T 11364 的规定编制。
O:表示该有害物质在该部件所有均质材料中的含量均在 GB/T 26572 规定的限量要求以下。
X:表示该有害物质至少在该部件的某一均质材料中的含量超出 GB/T 26572 规定的限量要求。
铅是欧洲RoHS指令2011/65/ EU附件三和附件四目前由于允许的豁免。
CHINA RoHS COMPLIANCE
Manual 21354 Rev E
ECN 50523
Component Name
Hazardous Substances
Lead (Pb)
Mercury (Hg)
Cadmium (Cd)
Chromium VI
Compounds
(Cr(VI))
Polybrominated
Biphenyls (PBB)
Polybrominated
Diphenyl Ethers
(PBDE)
Housing
O
O
O
O
O
O
PCB Board
X
O
O
O
O
O
Electrical Connectors
O
O
O
O
O
O
Piezoelectric Crystals
X
O
O
O
O
O
Epoxy
O
O
O
O
O
O
Teflon
O
O
O
O
O
O
Electronics
O
O
O
O
O
O
Thick Film Substrate
O
O
X
O
O
O
Wires
O
O
O
O
O
O
Cables
X
O
O
O
O
O
Plastic
O
O
O
O
O
O
Solder
X
O
O
O
O
O
Copper Alloy/Brass
X
O
O
O
O
O
This table is prepared in accordance with the provisions of SJ/T 11364.
O: Indicates that said hazardous substance contained in all of the homogeneous materials for this part is below the limit
requirement of GB/T 26572.
X: Indicates that said hazardous substance contained in at least one of the homogeneous materials for this part is above the limit
requirement of GB/T 26572.
Lead is present due to allowed exemption in Annex III or Annex IV of the European RoHS Directive 2011/65/EU.
401B04 ICP
®
Sensor Simulator
1. INTRODUCTION AND DESCRIPTION
The Model 401B04 is a unity gain, non-inverting, impedance-converting voltage amplifier with the same
characteristics as the built-in ICP
®
amplifiers provided in most PCB pressure sensors, force sensors, and
accelerometers. This model consists of MOSFET circuitry packaged in a convenient Pomona box with BNC
connectors. When used in conjunction with a signal generator or oscillator, it can be used in place of an ICP
sensor to calibrate ICP
®
sensor signal conditioners, do system verifications and gain adjustments, or check
frequency response of systems with long input cables. (The Model 401B04 simulates the circuit of an ICP
®
sensor while the signal generator takes the place of the sensor’s crystals.)
2. INSTALLATION AND OPERATION
CAUTION: Connect the output only to an ICP
®
type, current-limited signal conditioner.
WARNING: Excessive current may damage this model. Measure the ICP
®
sensor signal conditioner
current prior to connecting the 401B04. The ICP
®
excitation current should be ≤20 mA.
2.1 CALIBRATION OF ICP
®
SENSOR SIGNAL CONDITIONERS
Refer to the acceptance test procedure for your particular PCB signal conditioner, dual mode charge
amplifier, or digital peak meter model. (Acceptance test procedures are available for most PCB electronic
products. Consult factory for details.)
Connect a signal generator or oscillator to the input jack of the 401B04, after observing the caution and
warning above. Connect the output jack of the 401B04 to the ICP
®
sensor signal conditioner being
tested. (Various cables and adaptors are available from PCB as needed.) Switch on the signal
conditioner and note the output bias voltage on the meter as you would for any ICP
®
sensor. The meter
should read mid scale, indicating that the 401B04 is operational. Follow the acceptance test procedure
for your particular PCB model. The exact gain factor (near unity) of the 401B04 is noted on the
calibration certificate supplied with the unit. The nominal value of Gain = 1.0 is on the housing of the unit.
401
B04 Simulator
Frequency Counter
Function Generator
Digital Volt Meter
Oscilloscope
Signal Conditioner
(Unit Under Test)
401B04
Simulator
Frequency Counter
Function Generator
Digital Volt Meter
Oscilloscope
Signal Conditioner
(Unit Under Test)
401B04 Simulator
Frequency Counter
Function Generator
Digital Volt Meter
Oscilloscope
Signal Conditioner
(Unit Under Test)
PAGE 2
2.2 MEASUREMENT SYSTEM CHECKOUT AND/OR GAIN ADJUST
The Model 401B04 is inserted in place of the ICP
®
sensor in your measurement system. Connect the
input of the 401B04 to a signal generator and the output to the ICP
®
sensor signal conditioner. Also
connect any additional amplifiers or recording devices that will be used in the test, as shown in the figure
above. After switching on all equipment and allowing sufficient warm-up time, apply a known signal
through the system with the signal generator and adjust gains, ranges, zeroes, etc., as needed.
2.3 CALIBRATION OF LONG LINES
Model 401B04 can be used, in conjunction with an oscillator or step function generator, to simulate an
ICP® sensor driving a long input cable between the sensor and the ICP sensor signal conditioner. Refer
to PCB “General Guide to ICP® Instrumentation” for more details on the procedure.
3. FREQUENCY RESPONSE CONSIDERATIONS
When used with a signal generator for system checkouts or testing of long lines, low frequency response of
the 401B04 is DC.
High frequency response of the Model 401B04, when driving short cables with small (~1V) signals, is 1
megahertz. Refer to PCB “General Guide to ICP® Instrumentation.” if long cables are to be driven. Also,
consult the factory if less than 2 mA constant current will be used to power the 401B04.
4. MEASUREMENT AND REPAIR
The miniature size precludes most maintenance. If used in a very humid or dirty environment, signal
degradation, usually in the form of reduced output or loss of low frequency response, may occur. If the
connectors become dirty, clean with Freon TF ®, Genesolv, or other suitable solvent that leaves no residue.
Manual Number: 40858
Manual Revision: A
ECN Number: 38393
Model Number
401B04 ICP® SOURCE FOLLOWER Revision: F
ECN #: 52519
Performance ENGLISH SI
Gain(+ 0 to -2 %) 1 1
Output Range ± 5 V ± 5 V
Low Frequency Response 0 Hz 0 Hz
High Frequency Response(2.0 mA) 110 kHz 110 kHz [1]
High Frequency Response(4 mA) 220 kHz 220 kHz [1]
High Frequency Response(20 mA) 1,000 kHz 1,000 kHz [1]
Non-Linearity ≤ 2 % FS ≤ 2 % FS
Environmental
Temperature Range(Operating) +30 to +150 °F -1.1 to +65.5 °C
Electrical
Excitation Voltage + 18 to 30 VDC + 18 to 30 VDC [2]
Constant Current Excitation 2 to 20 mA 2 to 20 mA
Output Impedance < 100 Ohm < 100 Ohm
Output Bias Voltage + 7 to 14 VDC + 7 to 14 VDC
Output Current 1 to 19 mA 1 to 19 mA [3]
Broadband Electrical Noise(10 to 100,000
kHz)
12 µV rms 12 µV rms [4]
Spectral Noise(1 Hz) 4 µV/√Hz 4 µV/√Hz [4]
Spectral Noise(10 Hz) 1 µV/√Hz 1 µV/√Hz [4]
Spectral Noise(100 Hz) 0.3 µV/√Hz 0.3 µV/√Hz [4]
Spectral Noise(1 kHz) 0.1 µV/√Hz 0.1 µV/√Hz [4]
Spectral Noise(10 kHz) 0.05 µV/√Hz 0.05 µV/√Hz [4]
Insulation Resistance(Minimum) 109 Ohm 109 Ohm
Physical
Housing Material Aluminum Aluminum
Electrical Connector(Input) BNC Plug BNC Plug
Electrical Connector(Output) BNC Jack BNC Jack
Size (Length x Width x Height) 2.2 in x 1.1 x 0.9 55.9 mm x 27.9 x 22.9
Weight 2.50 oz 70.9 gm
[5]
All specifications are at room temperature unless otherwise specified.
In the interest of constant product improvement, we reserve the right to change specifications without notice.
ICP® is a registered trademark of PCB Piezotronics, Inc.
OPTIONAL VERSION S
Optional versions have identical specifications and accessories as listed for the standard model except
where noted below. More than one option may be used.
NOTES:
[1]Above stated frequency, the amplifier becomes slew rate limited.
[2]Voltage < 20 VDC reduces input range to ±3V.
[3]Excitation current supplied minus 1 mA nominal current consumption.
[4]Typical, tested with 1000 pF capacitance at input.
[5]See PCB Declaration of Conformance PS024 for details. A low impendance connection from case
to earth ground is required to maintain CE compliance.
Date: 01/27/2022 Date: 01/27/2022 Date: 01/27/2022 Date: 01/27/2022 40857
Entered: TP Engineer: CPH Sales: AH Approved: JWH Spec Number:
Phone: 716-684-0001
Fax: 716-684-0987
E-Mail: info@pcb.com
3425 Walden Avenue, Depew, NY 14043