PCE Health and Fitness VE 250 User manual

© PCE Instruments
PCE-VE 250 Industrial Borescope
User Manual
User manuals in various languages (français,
italiano, español, português, nederlands, türk, polski,
русский, 中文) can be found by using our
product search on: www.pce-instruments.com
Last change: 23 October 2019
v1.0
English

© PCE Instruments
Contents
1Safety notes........................................................................................... 1
2Specifications........................................................................................2
2.1 Technical specifications ................................................................................................... 2
2.2 Delivery contents.............................................................................................................. 3
3System description............................................................................... 3
3.1 Device.............................................................................................................................. 3
3.2 Display............................................................................................................................. 4
3.3 Handheld device .............................................................................................................. 5
3.4 Camera and cleaning head .............................................................................................. 5
4Getting started....................................................................................... 6
4.1 Insert micro SD card......................................................................................................... 6
4.2 Assembly/disassembly of the display ............................................................................... 6
4.3 Charging .......................................................................................................................... 6
5Operation ............................................................................................... 6
5.1 On/off............................................................................................................................... 6
5.2 Taking a picture................................................................................................................ 6
5.3 Recording settings ........................................................................................................... 6
5.4 Video recording................................................................................................................ 7
5.5 Viewing the saved data.................................................................................................... 7
5.6 Cleaning function ............................................................................................................. 7
5.7 Settings............................................................................................................................ 8
6Operating conditions............................................................................ 9
7Troubleshooting....................................................................................9
8Warranty...............................................................................................10
9Disposal ...............................................................................................10

© PCE Instruments
1
1 Safety notes
Please read this manual carefully and completely before you use the device for the first time. The
device may only be used by qualified personnel and repaired by PCE Instruments personnel.
Damage or injuries caused by non-observance of the manual are excluded from our liability and
not covered by our warranty.
•The device must only be used as described inthis instructionmanual. If used otherwise,
this can cause dangerous situations for the user and damage to the meter.
•The instrument may only be used if the environmental conditions (temperature, relative
humidity, …) are within the ranges stated in the technical specifications. Do not expose
the device to extreme temperatures, direct sunlight, extreme humidity or moisture.
•Do not expose the device to shocks or strong vibrations.
•The case should only be opened by qualified PCE Instruments personnel.
•Never use the instrument when your hands are wet.
•You must not make any technical changes to the device.
•The appliance should only be cleaned with a damp cloth. Use only pH-neutral cleaner,
no abrasives or solvents.
•The device must only be used with accessories from PCE Instruments or equivalent.
•Before each use, inspect the case for visible damage. If any damage is visible, do not
use the device.
•Do not use the instrument in explosive atmospheres.
•The measurement range as stated in the specifications must not be exceeded under
any circumstances.
•Non-observance of the safety notes can cause damage to the device and injuries to
the user.
•The borescope has been developed for industrial use and must not be used for medical
purposes.
•Never target persons or animals with the device.
•Only use the device for the intended purpose.
We do not assume liability for printing errors or any other mistakes in this manual.
We expressly point to our general guarantee terms which can be found in our general terms of
business.
If you have any questions please contact PCE Instruments. The contact details can be found at
the end of this manual.

© PCE Instruments
2
2 Specifications
2.1 Technical specifications
Main unit
Display
3.5" TFT LCD
Resolution video function
AVI (640 x 480)
Resolution image function
JPEG (640 x 480)
Image rotation
360° rotation und mirror function
Freeze function
Yes
Zoom
4-fold, digital
Storage medium
Micro SD card (4 GB)
Menu languages
German
English
Spanish
French
Russian
Japanese
simplified Chinese
traditional Chinese
Interfaces
Micro USB 2.0, TV output, Micro SD card slot
TV output
PAL
Power supply
Li-ion battery (2600-mAh)
Typical battery life per battery charge
4 hours in continuous operation
Protection class
Splashproof
Endoscope cable
Camera head diameter
8.5 mm / 0.33 in
Cable diameter
4.5 mm / 0.18 in
Cable length
ca. 90 cm / 2ft 11 in
Camera resolution
720 x 576 Pixel
Camera lighting
6 white LEDs (adjustable intensity)
Field of view / angle of view
60°
Field of view depth
30 ... 60 mm / 1.18 ... 2.36 in
Push cable
semi-flexible
Environmental conditions of digital endoscope PCE-VE 250
Operating temperature probe
In air: -10 … 50°C / 14 ... 122°F
In water: 5 … 50°C / 41 ... 122°F
Operating temperature main unit
In air: -10 … 50°C / 14 ... 122°F
Relative humidity probe and main unit
15 ... 90%
Liquid resistance probe and main unit
Machine oil, light oil or saline solution 5%
Probe
Water, oil and dust, to protection class IP67
Main unit
Splash-proof (with closed battery compartment)
not usable under water

© PCE Instruments
3
2.2 Delivery contents
1 x Industrial Borescope PCE-VE 250
1 x Attachable TFT LCD
1 x AV output cable
1 x USB cable
1 x Car charging adapter
1 x Micro SD card
1 x Liquid container
1 x Carrying case
1 x Quick shut-off valve
1 x User manual
3 System description
3.1 Device
1
2
3
4
1. Display unit
2. Borescope
3. Camera cable
4. Liquid container

© PCE Instruments
4
3.2 Display
1. On/off key
2. Micro SD card slot
3. Micro USB 2.0
4. TV output
5. Up/zoom key
6. Settings key
7. Image key
8. Video/OK key
9. Down/rotation key
10. Image memory key
11. LED key
12. Display lock
12
1
2
3
4
5
6
11
10
9
8
7

© PCE Instruments
5
3.3 Handheld device
1. Pipe connection
2. Cleaning outlet
3. Shut-off valve
4. Cleaning button
5. Liquid container connection
6. Compressed air connection
3.4 Camera and cleaning head
1. Borescope head
2. Cleaning nozzle
3. Camera

© PCE Instruments
6
4 Getting started
4.1 Insert micro SD card
Before using the device, insert the micro SD card into the card slot (not included).
4.2 Assembly/disassembly of the display
Slide the display down onto the handheld device until it locks in
place.
To disassemble the display, slide the lock at the rear side of the
display outwards and pull up the display to remove it.
4.3 Charging
The device can be charged via the USB interface, using a micro
USB charger or the included car charging adapter.
5 Operation
5.1 On/off
Short-press the on/off key to turn the meter on or off.
5.2 Taking a picture
Press the image key to save the currently displayed image to the SD card. After saving the
image, the meter will automatically return to view mode.
5.3 Recording settings
With the LED key , you can set the brightness at the camera head in 4 levels: off, level 1,
level 2 and level 3. The LED icon in the lower right-hand part of the display shows the brightness
you have set.
You can set the zoom in 3 levels with the up/zoom key . The current zoom is shown with a
magnifying glass at the lower edge of the display.
To rotate the displayed image, press the down/rotation key .

© PCE Instruments
7
5.4 Video recording
Press the video/OK key to start recording a video. A video icon in the display shows that a video
is being recorded. Press the key again to stop recording. The video icon will disappear from the
display. The video will automatically be saved to the SD card when recording is finished.
5.5 Viewing the saved data
Press the image memory key to view thesaved images and videos. You can navigate through
the records with the arrow keys . The files are sorted by date and type.
5.6 Cleaning function
For cleaning, you can either use compressed air only or compressed air and water and/or a
cleaning agent. However, compressed air is needed for cleaning with a liquid as the compressed
air moves the liquid out of the nozzle. The liquid container must be placed onto the tube and fixed
with the union nut.
Tou se the cleaning function, place the camera cable where required and push the cleaning
button (4) of the handheld unit. If you wish to clean with liquid, the shut-off valve (3) must be
opened.
Borescope PCE-VE 250 Borescope PCE-VE 250
with open shut-off valve with closed shut-off valve

© PCE Instruments
8
5.7 Settings
To enter the settings, press the settings key and select language selection, time setting,
automatic shutdown setting or memory card format with the arrow up/down keys.
•Language
Select ”language selection“from the menu and press the video/OK key to enter
language selection mode. Use the navigation keys (▲and ▼) to select the desired
language and confirm your selection with the video/OK key.
•Date/time
Select “time setting“from the menu and press the video/OK key. Use the navigation
keys (▲and ▼) to set the desired value.
With the image memory key , you can navigate through the parameters.
•Energy saving
By selecting “shutdown setting“, you can set the time after which the device will turn
off automatically. Set the desired time by using the navigation keys (▲and ▼) and
confirm your selection with the video/OK key.
•Formating the memory card
In the menu item “memory card format“, you can set the inserted SD card.
Note: When you format the SD card, all saved files will be deleted from the SD card
irrevocably!

© PCE Instruments
9
6 Operating conditions
7 Troubleshooting
Operating conditions of the industrial borescope PCE-VE 250
Operating temperature
Probe
In the air: -10 … +50 °C
In water: +5 … +50 °C
Main unit
In the air: -10 … +50 °C
Relative humidity
Probe and main unit
15 … 90 %
Liquid resistance
Probe and main unit
Machine oil, light oil or saline
solution 5 %
Ingress protection
Probe
Water, oil and dust, IP67
protection
Main unit
Splash-proof (when battery
compartment is closed),
not submersible
Problem
Reason
Solution
The borescope does not
power on
Battery flat
Charge the meter by using the
USB cable
No records can be saved
No memory card
inserted
Insert an SD card
No liquid comes out of the
nozzle
No or insufficient
compressed air
Connect compressed air and
ensure 6-8 bar connection
pressure

© PCE Instruments
10
8 Warranty
You can read our warranty terms in our General Business Terms which you can find here:
https://www.pce-instruments.com/english/terms.
9 Disposal
For the disposal of batteries in the EU, the 2006/66/EC directive of the European Parliament
applies. Due to the contained pollutants, batteries must not be disposed of as household waste.
They must be given to collection points designed for that purpose.
In order to comply with the EU directive 2012/19/EU we take our devices back. We either re-use
them or give them to a recycling company which disposes of the devices in line with law.
For countries outside the EU, batteries and devices should be disposed of in accordance with
your local waste regulations.
If you have any questions, please contact PCE Instruments.

© PCE Instruments
11
PCE Instruments contact information
Germany France Spain
PCE Deutschland GmbH PCE Instruments France EURL PCE Ibérica S.L.
Im Langel 4 23, rue de Strasbourg Calle Mayor, 53
D-59872 Meschede 67250 Soultz-Sous-Forets 02500 Tobarra (Albacete)
Deutschland France España
Tel.: +49 (0) 2903 976 99 0 Téléphone: +33 (0) 972 3537 17 Tel. : +34 967 543 548
Fax: +49 (0) 2903 976 99 29 Numéro de fax: +33 (0) 972 3537 18 Fax: +34 967 543 542
www.pce-instruments.com/deutsch www.pce-instruments.com/french www.pce-instruments.com/espanol
Germany United Kingdom Italy
PCE Produktions- und PCE Instruments UK Ltd PCE Italia s.r.l.
Entwicklungsgesellschaft mbH Unit 11 Southpoint Business Park Via Pesciatina 878 / B-Interno 6
Im Langel 26 Ensign Way, Southampton 55010 Loc. Gragnano
D-59872 Meschede Hampshire Capannori (Lucca)
Deutschland United Kingdom, SO31 4RF Italia
Tel.: +49 (0) 2903 976 99 471 Tel: +44 (0) 2380 98703 0 Telefono: +39 0583 975 114
Fax: +49 (0) 2903 976 99 9971 Fax: +44 (0) 2380 98703 9 Fax: +39 0583 974 824
www.pce-instruments.com/deutsch www.pce-instruments.com/english www.pce-instruments.com/italiano
The Netherlands China Hong Kong
PCE Brookhuis B.V. PCE (Beijing) Technology Co., Limited PCE Instruments HK Ltd.
Institutenweg 15 1519 Room, 6 Building Unit J, 21/F., COS Centre
7521 PH Enschede Zhong Ang Times Plaza 56 Tsun Yip Street
Nederland No. 9 Mentougou Road, Tou Gou District Kwun Tong
Telefoon: +31 (0)53 737 01 92 102300 Beijing, China Kowloon, Hong Kong
www.pce-instruments.cn www.pce-instruments.cn
United States of America Turkey
PCE Americas Inc. PCE Teknik Cihazları Ltd.Şti.
711 Commerce Way suite 8 Halkalı Merkez Mah.
Jupiter / Palm Beach Pehlivan Sok. No.6/C
33458 FL 34303 Küçükçekmece - İstanbul
USA Türkiye
Tel: +1 (561) 320-9162 Tel: 0212 471 11 47
Fax: +1 (561) 320-9176 Faks: 0212 705 53 93
www.pce-instruments.com/us www.pce-instruments.com/turkish
Table of contents