ISSUED: 08-12-04 SHEET #: 128-9152-1
Visit the Peerless Web Site at www.peerlessindustries.com For customer service call 1-800-729-0307 or 708-865-8870.
1 of 2
For Wood Joist Finished Ceiling, Exposed
Wood Joists, or Wood Beam Ceiling. (See
step 3 forconcreteceilings).Drillfour5/32"(4
mm) dia. holes to a minimum depth of 2.5" (64
mm). Attach with four #14 x 2.5" (6 mm x 65
mm) wood screws as shown using 3/8" (10
mm) socket wrench. Tighten wood screws so
ceiling plate is firmly attached.
flush mount tube
(includedwithJumbo
MountBracket)
ceiling
plate
FromthetopthreadtheFlushMountTube
(includedwithyourJumboMountBracket)
throughthethreadedfittingintheceilingplate.
IMPORTANT: If you will install an extension
columnDONOT INSTALL THEFLUSH
MOUNT TUBE. Begin with step 2.
IMPORTANT! Read entire instruction sheet before beginning installation and assembly.
Installation and Assembly - Ceiling Plate for
Jumbo Mounts
Models: CMJ 470W, CMJ 480W,
CMJ 490W
This Ceiling Plate is intended for use only to support
Jumbo Mount TV Brackets or other products as
specifiedbyPeerlessIndustries,Inc.Combineonly
as specified (see specifications on page 2). Fasten-
ersprovidedareforattachmenttowoodstructural
members(joistsorbeam).Orderadditionalfastener
kit ACC 204 if attaching to a solid concrete ceiling.
CEILINGCONSTRUCTION ADDITIONALHARDWAREREQUIRED
Wood Joist, Wood Beam none
Concrete Concrete Anchor Kit - order accessory kit ACC 204.
Other or unsure? Call Peerless Customer Service.
IMPORTANT! Certain ceilings require additional mounting hardware...
MAXIMUMLOADCAPACITY:
300 lb (137 kg)
end
cap
R
This product is intended for use with UL
Listed products and must be installed by a
qualified professional installer.
• Installer must verify that the ceiling will safely support
fourtimesthecombinedweightofall attached equip-
mentandhardware.
WARNING
• Tighten wood screws so that ceiling plate is firmly
attached,butdonot overtighten.Overtighteningcan
damagethescrews,greatlyreducing their holding
power.
• Never tighten in excess of 80 in • lb (9 N.M.).
• Make sure that mounting screws are anchored into the
center of the studs. The use of an "edge to edge" stud
finderishighlyrecommended.
WARNING
PARTSLIST
PART # QTY. DESCRIPTION
128-2039 1 ceiling plate (CMJ 470W only)
128-2086 1 ceiling plate (CMJ 480W only)
128-2087 1 ceiling plate (CMJ 490W only)
5S1-015-C03 4 #14 x 2.5" (6 mm x 65 mm) wood screw
2PT-22CA01F 2 end cap (white models only)
520-9250 1 M5 x .8 x 10 mm phillips screw (for use
with extension column if applicable)