ISSUED: 7-8-98 SHEET #: 128-9017-4 08-19-04
Visit the Peerless Web Site at www.peerlessindustries.com For customer service call 1-800-729-0307 or 708-865-8870.
3 of 5
#For Concrete Wall use jumbo shelf, making
sure that it is level, as a template to mark
holes. Drill 1/4" (6 mm) dia. holes to a
minimumdepth of2.5" (64mm).Concrete
must be 2000 psi density minimum. Insert
anchors in holes flush with wall as shown
(right).Placejumboshelfoveranchorsand
secure with #14 x 2.5" (6 mm x 65 mm) wood
screws.Tightenallfasteners.
1
3
concrete
wall
concrete
anchor
concrete
anchor
concrete
anchor
D
D
2A
Tighten to 80 in • lb (9 N.M.) torque.
CUTAWAYVIEW
INCORRECT
concrete
plaster/
drywall
mounting
plate
CORRECT
concrete
plaster/
drywall
mounting
plate
WARNING
• When installing Peerless wall mounts on cinder block, verify that you have a minimum of 1-3/8" of actual concrete
surface in the hole to be used for the concrete anchors. Do not drill into mortar joints! Be sure to mount in a solid
part of the block, generally 1" minimum from the side of the block. Cinder block must meetASTM C-90 specifica-
tions. It is suggested that a standard electric drill on slow setting is used to drill the hole instead of a hammer drill
toavoid breaking outthe back ofthe hole whenentering a voidor cavity.
• Concrete must be 2000 psi density minimum. Lighter density concrete may not hold concrete anchor.
• Make sure that the wall will safely support four times the combined load of the equipment and all attached hard-
wareand components.
ACC 203 (sold
seperateley)
• Tightenwood screws firmly,but donot overtighten.
Overtighteningcan damagethe screws,greatly
reducingtheir holdingpower.
• Never tighten in excess of 80 in • lb (9 N.M.).
WARNING
• Concrete anchors are not intendedfor attachmentto
concretewall covered witha layer ofplaster,drywall,
orother finishing material.If mounting toconcrete wall
coveredwith plaster/drywallis unavoidable,plaster/
drywall (up to 5/8" thick) must be counterbored as
shown below. If plaster/drywall is thicker than 5/8",
custom fasteners must be supplied by installer.
WARNING
16"