Installation Wood Joist Finished Ceiling,
Exposed Wood Joists, or Wood Beam Ceiling.
(See 3for concrete ceilings). Drill four 5/32" (4 mm)
dia. holes to a minimum depth of 2.5" (64 mm).
Attach with four #14 x 2.5" (6 mm x 65 mm) wood
screws as shown using 3/8" (10 mm) socket
wrench. Tighten wood screws so ceiling plate is
firmlyattached.
PARTSLIST
PART # QTY. DESCRIPTION
128-1039 1 ceiling plate (CMJ 470 only)
128-1086 1 ceiling plate (CMJ 480 only)
128-1087 1 ceiling plate (CMJ 490 only)
5S1-015-C03 4 #14 x 2.5" (6 mm x 65 mm) wood screw
2PT-22CA01D 2 end cap
520-9250 1 M5 x .8 x 10 mm phillips screw (for use
with extension column if applicable)
flush mount tube
(includedwithJumbo
MountBracket)
ceiling
plate
FromthetopthreadtheFlushMountTube(included
withyourJumboMount Bracket) through the
threaded fitting in the ceiling plate.
Note: If you will install an extension column DO NOT
INSTALL THE FLUSH MOUNT TUBE. Begin with step 2.
Note: Read entire instruction sheet before
beginning installation and assembly.
Installation and Assembly - Ceiling Plate for Jumbo Mounts Models: CMJ 470
CMJ 480 CMJ 490
Note: This ceiling plate is intended for use only to support Jumbo Mount TV Brackets or other products as specified by Peerless
Industries,Inc.Combineonlyasspecified(seespecificationsonpage2).Fastenersprovidedareforattachmenttowoodstruc-
turalmembers (joistsor beam).Order additionalfastenerkit ACC 244 ifattaching to asolidconcrete ceiling. This product is
intendedfor indoor useonly. Use ofthis product outdoorscould lead toproduct failure and personal injury.
CEILINGCONSTRUCTION ADDITIONALHARDWARE REQUIRED
Wood Joist, Wood Beam none
Concrete Concrete Anchor Kit - order accessory kit ACC 244.
Other or unsure? Call Peerless Customer Care.
IMPORTANT! Certain ceilings require additional mounting hardware... For customer care, or to order
accessory kits call
1-800-7865-2112
Max. Load Capacity:
300lb (137 kg)
end
cap
R
This product is intended for use with UL
Listed products and must be installed by a
qualified professional installer.
• Tighten wood screws so that ceiling plate is firmly
attached,butdonotovertighten.Overtighteningcan
damagethescrews, greatly reducing theirholding
power.
• Never tighten in excess of 80 in. • lb (9 N.M.).
• Make sure that mounting screws are anchored into the
center of the joists. The use of an "edge to edge" stud
finderishighlyrecommended.
WARNING