10 of 33 ISSUED: 09-20-06 SHEET #: 202-9167-3 01-26-07
Installation to Solid Concrete or Cinder Block
Make sure that wall plate (AA) is level, use it as a
templateto mark four mounting holes. The top
mountinghole should be 2.5" above the desired screen
center as shown in figure 4.1 on page 8. Drill four 1/4"
(6 mm) dia. holes to a minimum depth of 2.5" (64 mm).
Insert anchors (EE) in holes flush with wall as shown
(right).Placewall plate over anchors and secure with
#14 x 2.5" screws (DD). Level, then tighten all
fasteners.
NOTE: Six holes and six sets of fasteners are required
whenmounting the wall plate forequipment weighing
greaterthan 200 lbs.
• When installing Peerless wall mounts on cinder block, verify that you have a minimum of 1-3/8" of actual concrete
thickness in the hole to be used for the concrete anchors. Do not drill into mortar joints! Be sure to mount in a solid
part of the block, generally 1" minimum from the side of the block. Cinder block must meetASTM C-90 specifica-
tions. It is suggested that a standard electric drill on slow setting is used to drill the hole instead of a hammer drill to
avoid breaking out the back of the hole when entering a void or cavity.
• Concrete must be 2000 psi density minimum. Lighter density concrete may not hold concrete anchor.
• Makesurethatthe supporting surface will safely support the combined load of the equipment and all attached hard-
wareand components.
WARNING
CUTAWAY VIEW
INCORRECT
concrete
surface
1
3
2
EE
Drill holes and insert anchors (EE).
CORRECT
Place plate (AA)over anchors (EE) and secure with screws (DD).
Tighten all fasteners.
wall
plate
plaster/
drywall
concrete wall plate concrete
plaster/
drywall
• Always attach concrete anchorsdirectly to load-
bearingconcrete.
• Neverattach concreteanchorsto concretecovered
withplaster, drywall, or other finishingmaterial.If
mountingto concrete surfacescoveredwith a finishing
surfaceis unavoidable, thefinishingsurface must be
counterbored asshown below. Be sure concrete
anchorsdo not pull away fromconcrete when tighten-
ing screws. If plaster/drywall is thicker than 5/8",
custom fasteners must be supplied by installer.
(Notevaluatedby UL)
WARNING
AA
• Tighten screws so that wall plate is firmly attached,
but do not overtighten. Overtightening can damage
screws, greatly reducing their holding power.
• Never tighten in excess of 80 in. • lb (9 N.M.).
WARNING
DD
AA
EE
DD
EE
solid concrete cinder block