Pegasus PP-3702/T Series Quick start guide

Intelligent Time Attendance Recorder & Access Controller
Access Control/Time & Attendance / Lift Access Control System/ Security
PP-3702/T Series
Operational Manual
Ver.11.1
W-04-PP3702T/E

2
Table of contents
S
y
stem introduction 1
General features 1
S
p
ecification 3
LCD instruction 4
Panel descri
p
tion 6
Bottom view 6
Wirin
g
connectors and PIN assi
g
nment 7
How to connect PP-3702T to a com
p
uter? 1
Exam
p
le of wirin
g
1
Controller and
r
ela
y
b
ox wirin
g
exam
p
le 1
Brief s
y
stem
p
ro
g
rammin
g
1
Chan
g
e the master PIN 1
Function code instruction 1
F0: Delete all
p
ersonal ma
p
17
F1:Access b
y
ke
y
in user ID throu
g
h maste
r
PIN 17
F2:Set weekda
y,
hour
,
minute 18
F3:Calendar
y
ear
,
month and date settin
g
18
F4: Parameters & Modes 18
Grou
p
0.S
y
stem initiation 3
Grou
p
1.In
p
ut commands 3
Grou
p
2.Out
p
ut commands 3
Grou
p
3.O
p
eration
m
odes 3
Grou
p
4. PIN or
m
aster PIN settin
g
3
Grou
p
5.In
q
uir
y
mode 3
Grou
p
6.Time zone
m
ode/add card
m
ode 3
Grou
p
7.Delete card
m
ode 3
Grou
p
8.S
y
stem confi
g
urations 3
G
r
oup
9.
F
acto
r
y
c
o
nfi
gu
r
at
i
o
n
3

3
F5 : In
q
uir
y
mode 19
A. Sin
g
le card in
q
uir
y
1
B. Inquiry with learning mode 1
C. In
q
uir
y
card status b
y
block mode 1
F6:Add
p
ersonal ma
p
2
A. Add card no. 2
B. Add card no. and PIN 2
C. Add card with learnin
g
mode 2
D. Add card with block mode 2
F7: Delete
p
ersonal ma
p
2
A. Delete sin
g
le card 2
B. Delete card with leanin
g
mode 2
C. Delete card with block mode: 2
D. Delete card with block mode 2
F8: Time zone/holida
y
/bell
p
ro
g
rammin
g
2
A. Personalized mode 2
B. Free access mode 2
C. Holida
y
mode 2
D. Bell alarm mode 2
F9: Modif
y
events counter for event retrievin
g
3
F*:Inquiry and display the stored events 3
Sim
p
le and eas
y
trouble shootin
g
3
A
pp
endix 4

4
Packing list
Before getting start, please check the PP-3702/T package contains the
following items:
DESCRIPTION Q’TY
The system unit 1 unit
1 9 Pin connector (Blue) 1 pc
2 8 Pin connector (White) 1 pc
3 5 Pin connector (White) 1 pc
4 4 Pin connector (White) 2 pc
5 Screw 1 pc
6 Free wheeling diode 1 pc
7 Sealing rubber for
waterproof 1 pc

1
PP-3702/T is an intelligent time recording terminal designed to meet the
variant applications in time attendance and access control, lift control
& ARM/DISARM security requirements.Each terminal can be operated
independently or through PC/Internet adapter PC-T100 to fulfill the multiple
terminal system. The recording terminal includes nearly all the necessary
functions for time recording and access control.Users can use master PIN to
select the desired functions from the abundant functional list (For malfunction,
please contact with your local distributors)
The system could be started by modifying the factory defaulted templated as
by code F4 + 0850 and then save them by 0650 to back up for farther
configuration your system by 0950, if you confused your configuration.
General features
1-A Time recording features:
1、High capacity with 8 digits card number / 6 digits staff number and 8
character English name.( Either checking or without checking personal
map )
2、16 characters x2 rows of LCD disply with 8 digits which have
year, month,day,week,time, IP,operation mode,real time mode,unlock
time, door monitoring.
3、79 duty codes, duty name defined by PC.
4、Selectable batch or real time on-line mode.
5、Key in 8 digits ID for time attendance recording.
6、Totally 192 alarm schedules (8 schedules per hour) dry contacts output
for periodic bell announce.
There are 6 versions available:
(1)K Version: 1,000 card capacity, 500 events.
(2)L Version: 2,000 card capacity, 1,000 events.
(3)M Version: 30,000 card capacity, 10,000 events.
(4)N Version: 11,000 card capacity, 32,000 events.
(5)P Version: 11,000 card capacity, 8,000 events.
(6)X Version: 32,000 card capacity, 32,000 events.
Versions could be getting thru the equipped RS-485 interface.
System introduction

2
1-B. Access control features: (Main application)
1. System parameters and personal access map can be down loaded by PC
or manually programmed through keypad.
2. The personal access map is consisted of card ID, staff number and staff
name, PIN and Time Zone Status, expiry date and
Anti-passback.Operation modes : (1) card only (2) card + PIN (3)Door
PIN only and duress feature (4)Card no +PIN and duress feature(5)Free
access (6) Automatic operation mode by time zones
NOTE: The staff name is used under F4=9601, 3400 cards capacity only.
3. Individual personal access map can be added/deleted and checked by
on-lined PC or through manually in single / block range card number or
by direct reading card in learning mode.
4. Selectable immediate or batched serial output for event printing
5. With complete door release, status monitoring and intruded alarm
periord & error trials.

3
Dimensions :174mm(L) x 100mm(W) x 43mm(H)
Weight :600g± 5%
Power supply :DC 12V±10%, 80mA~100mA(not include power
requirement for lock & alarm)
Transmission rate :Default 9,600 bps N,8,1(2,400bps/4,800bps)
(19,200bps/38,400bps<selectable>)
Operating temperature :0 ~70℃℃
Operating humidity :10%~90%
Keypad :For system programming, pass word entry or duty code
selection.
Password :Programmable 4 digits PIN for each person
Serial interface :RS-485 & RS-232 & TCP/IP
Serial output :1.To link with PG-1050B printer interface adaptor
for Centronics printer port or direct to serial
printer
*2. To drive DDR (digital door relay) for safety
control model.
3. Lifts controller. common door codes
Events/card capacity :(1) K Version: 1,000 card capacity, 500 events.
(2) L Version: 2,000 card capacity, 1,000 events.
(3) M Version: 30,000 card capacity, 10,000 events.
(4) N Version: 11,000 card capacity, 32,000 events.
(5) P Version: 11,000 card capacity, 8,000 events.
(6) X Series: 32,000 card capacity, 32,000 events.
Other capacity combination requested by order
Card standard :EM 125KHz / Mifare 13.56MHz(ISO 14443A or ISO
14443B) / HID 125KHz(Depending on order)
Wiegand 26/34 bits port for any kind of reader
External Reader :With one or optional two port for external Wiegand (26/34
bits definable by command) &
ABA input(by order)
Specification

4
Normal Display: After plug-in power, LCD displays as below:
Y Y / M M / D D
hh:m m XXX. +NNNNN
Y Y/ M M / D D: The calendar year, month and date (Year/ Month/ Day)
h h:mm:System clock, Hour & Minute (hh=00~23;mm=00~59)
X X X:weekday Monday to Sunday
NNNNN:The transaction records stored in the buffer.
When display shows “FULL”, which means the butter is full. Please download the
records by PC or press Master PIN and then press”9”,key-in “000000” to erase the
events.
Parameter display: key-in “9”, LCD displays as below:
Aaa Wt tt 96
AD R . W A T . D O R . BPS
Aaa : Polling address by F4=88aa (00~99)
WAT :Real time on-line waiting time by F4=890t (0~9), “0” for
baten mode by F4=99nn
DOR :Door released time by F4=21tt(00~99)
BPS :Buad Rate 96=9600 48=4800 24=2400 19=19200
N Wt tt N-N
REP . M O T . D P T . T - A
REP:Door Monitoring Status time for check repeat reads in unit of
second
N=t Check repeating card with t minutes
N=0 Norepeatingcardcheck
MOT: Door monitoring time by code F4=230t
LCD instruction
First display Parameter value
Parameter name
Second display Parameter value
Parameter name

5
DPT : LCD message display time by F4=250t, useful for F*
T-A :Time zone control – Free access mode
Y - Enable function
N -Disable function
*Note: The system could be operated in proper order only when the address
code is correctly programmed through 88nn. If the reader address is
not correctly programmed, the display of address will show some
other ASCII characters as “xxx“ above the ADR.which can’t save the
event; therefore you should program again.
Third display
R.rrrrr: The read counter of buffer
W.wwwww: The write counter of buffer
Version:CPU version
Note: Accoring to actual version.
R.r r r r r W.w w w w w
Version P372P36Q

6
Bottom view
Panel description
J1-8 pins connector for Communication and
alarm output
J2-9 pins connector for Access port
KJ10- 4 pins connector for external reader
KJ11-4 pins connector for external
reader(Optional)
KJ4-5 pins connector for bell outport
KLJ1-RJ-45(For TCP/IP)

7
Wiring connectors and PIN assignment
A. J2-9P
Blue (For power input and access functions)
*Note:
Please connect the blue wire to GND if the Door Monitoring function is
unnecessary.
Please connect the purple wire to GND if the Security Sensor function is
unnecessary.

8
E.KLJ1-RJ-45(For TCP/IP)
PIN Number Signal
1 TPTX+
2 TPTX-
3 TCT
4 NC
5 NC
6 RCT
7 TPRX+
8 TPRX-

9
Note: Via RJ45 cable to a computer directly
Please change one of the RJ45 connector (crossing).

10
How to connect PP-3702T to a computer?
Change IPaddress(IE only) & change Ports setting
a. Change IP address(IE only)
1. Start IE (Internet Explorer), keyin IP address: 192.168.1.120 on internet to
start the setting.
2.Select DHCP Mode to Static IP, and key-in IP address.
3.Press “ Update” for upload complete.
zIPAddress: Please search useful/ vacancy IP address.
zSubnet Mask/ Gateway IP: Please compliance Internet of Ethernet
or check “ Start”Æ” run”Ækey in ” cmd” then click “OK”Ækeyin
“ ipconfig” to get the information.

11
b. Change serial ports
1. Please set Serial Port1.
1) Baud Rate: 9,600
2) Data Size: 8
3) Interface: RS232
4) Local Telnet Port Number: 4001
(*Note: Our software uses socket port “4001”)
5) Click “ Update” for complete setting.

12
2. Please set Serial Port2.
1) Baud Rate: 9,600
2) Data Size: 8
3) Local Telnet Port Number: 4001 (Note: Our software uses
socket port “4001”)
4) Click “ Update” for complete change.

13
Example of how to wiring

14
※R-27-YK10T1/125/250V is line filter to avoid signal interference.
If elevator cont※roller doesn’t work; please turn off “Bypass switch”
of non-controlled button.
To connect 2 or 3 of 24 floor controllers to achevie 64 floors access※
of set up.
※Please refere appendix for floor controller of relate operation manner.

15
PP-3702/T PG-OUTMOD-8 Relay Box
9 Pin Blue Connector J5-7PinBlueConnector
Color Signal Name Color SignalName
No1.Red +12V No1.Red +12V
No2.Black GND No2.Black GND
No3.Brown No3.Orange No Connection
No4.Orange No4.Purple SerialPrinterInput
No5.Yellow No5.Black NoConnection
No6.Green No6.Gray No Connection
No7.Blue No7. Gray No Connection
No8.Purple
No9.Gray Serial Printer Output
PP-3702/T PG-OUTMOD-24 Relay Box
9 Pin Blue Connector J5-9 Pin Blue Connector
Color SignalName Color SignalName
No1.Red +12V No1.Red +12V
No2.Black GND No2.Black GND
No3.Brown No3.Brown NoConnection
No4.Orange No4.Orange Serial Printer Input
No5.Yellow No5.Yellow No Connection
No6.Green No6.Gree No Connection
No7.Blue No7. Blue No. Connection
No8.Purple No.8Purple
No9.GraySerialPrinterOutput No.9Gray
Controller and relay box wiring example

16
System initialize (default password 246890)
The system initialization means the system parameters are defaulted by
F4=0850(off-line mode) or F4=0750(on-line mode). Then the user could
modify some parameters based on it. After each modification to individual
requirement, the user may backup them by code F4=0650. Once the
parameters are destroyed, the code F4=0950 could be applied to restore it.
All the function code under F4 is disabled, except the timer for 21tt, 22…..
1. Door monitoring::Disable the door monitor function ( F4=1100 )
2. Presonal map compare:Not compare ( F4=1500 )
3. Door release time :close one second(F4=2101)
4. Door open mode:card only mode(F4=3200)
5. Anti-pass back mode : Disable (F4=3900)
6. Check repeat card : Disable(F4=8300)
7. Printer output function:Disable ( F4=8600 )
8. When event buffer full:Not recycle ( F4=8700 )
9. Computer connect mode:real time mode ( F4=8903 )-F4=0750
batch mode ( F4=8900 )-F4=0850
Operating instruction
The manager could program the controller by pressing “0” and master PIN
(default password as “246890”.The password could be modified by F4=4609)
to enter into the PROGRAM mode.
Summary of fuctions code please refer to ndex on the system introduction.
F0
【0】: Delete all personal map
F1
【1】: Key in user ID for access by master PIN
F2
【2】: Set weekday, hour, minute
F3【3】: Program Calendar year, month and date
F4【4】:
Parameter modes & Modes
F5【5】: Inquiry Personal access map
F6【6】: Add personal map
F7【7】: Delete personal map
F8【8】: Time zone/holiday/bell programming & Inquiry
F9【9】: Modify events counter for event retrieving
F10【*】: Display or print out recorded
Note:The programming procedures could be escaped by pressing ”#” by key.