Pelsis Curtis Dyna-Fog Hurricane User manual

Introduction
Thank you for purchasing the Hurricane. Please read this User
Guide to understand and ensure safe, proper, effective and
responsible use of the Hurricane.
Safety Precautions
Please ensure you have read and fully understood the safety
precautions before operating this appliance. For further in depth
instructions please refer to the supplementary on-line user manual
(www.hurricane-es.com).
Instructions for use of this product will vary depending on chemical
applications. Always read the product label when preparing your
solution.
• Always comply with any requirements for Personal Protective
Equipment (PPE) as required by the formulation label.
• This appliance is to be kept out of reach from children.
However, it can be used by children aged 8 years and above,
as well as persons with reduced physical, sensory or mental
capacities or lack of experience and knowledge, provided they
have been given supervision or instruction concerning use
of the appliance in a safe way, and understand the hazards
involved.
• Children should not play with the appliance, and cleaning
and user maintenance should not be made by children
without supervision.
• Children should be supervised to ensure they do not play with
the appliance.
• Users should hold the appliance and manually cover the
designated fogging areas.
• The fogger should not be left operating unattended, and for
the most efcient application it should not be left stationary.
• This fogger can be used with water-based, oil-based, and
solvent-based formulations.
• Never direct fogging at live electrical items,animals,humans,
etc. Remember to cover aquariums before fogging takes
place.
Please take note of the below diagram to familiarise yourself with the
design and structure of the unit:
CARRYING HANDLE
AIR INTAKE AREA
ON/OFF SWITCH
WITH LIGHT
REMOVABLE FILLING
CAP WITH TETHER
ADJUSTABLE
LOCKING DEVICE
STAINLESS STEEL
PRECISION METERING
VALVE WITH FILTER
THREE (3) PRECISION
NOZZLES FOR GREATER
OUTPUT CAPACITY
TRANSLUCENT
CORROSION
AND IMPACT
RESISTANT
TANK
Operation
• Ensure you are wearing appropriate PPE when operating this
fogger.
• If the use of an extension lead is required, ensure it is rated at
230V 13Aand is grounded. Only use an extension lead which
is properly rated for voltage, current, length, and which is free
from nicks, cracks, and other signs of prior abuse. Replace
damaged or worn electric leads immediately.
• Do not use a fogger that is broken or damaged in any way. Do
not alter the fogger by adding or removing parts.
• Do not restrict the motor blower air intake area.
Formulation
• Always read the product label when preparing your solution
and ensure the formulation is suitable for the intended
application.
• This fogger can be used with water-based, oil-based, and
solvent-based formulations. Ensure that formulation is
applied only in strict compliance with the formulation label
and store formulation in its original labelled container.
• Remove the lling cap to pour formulation into the tank. Add
only premixed/diluted formulations to the tank.
Operation
• With the fogger power off, remove the lling cap and pour
your premixed formulation into the tank, up to a maximum
3.8 litres, and replace the cap.
• Ensuring the fogger is pointing in a safe direction, turn on via
the power switch and select the appropriate ow valve setting.
• The exact method of operation is dependent on a number
of factors, including the application, ow rate, formulation
viscosity, but best results are normally achieved maintaining
a distance of 1-4 metres from the items you want to fog. Keep
moving the fogger with slow, steady movements for an even
coverage, starting from the highest point. If there is liquid
run-off then the application is too heavy, either move further
away, adjust the ow rate or speed up.
• Do not allow the fogger to operate unattended. Do not stand
in water or hold over water while operating fogger and do not
allow the power lead or extension lead to be submersed in
water.Do not use outdoors when it’s raining.
• Do not block the air intake area.
230V Fogger
USER GUIDE Pelsis UK Contact Number: +44 (0) 800 988 5359
Pelsis Belgium Contact Number: +32 (0) 3 886 22 11
Pelsis UK Contact Number: +44 (0) 800 988 5359
Pelsis Belgium Contact Number: +32 (0) 3 886 22 11
Pelsis Ltd
Sterling House, Grimbald Crag Close,
Knaresborough, HG5 8PJ, UK
Pelsis Belgium NV
Industrieweg 15, 2880
Bornem, Belgium

Flow Rate Information
Please use the below table as a reference for the ow rate of the
Hurricane.
Metering
Valve
Setting
Hurricane Flow Rate And Droplet Size
Flow Rate Droplet Size
mL/Min Microns - Volume
Median Diameter
#1 60 40-50 MICRONS
#2 90 40-55 MICRONS
#3 120 45-70 MICRONS
• Thicker viscosity liquids will ow at lower rates than demon-
strated in the above table, and produce a bigger droplet size.
• Adjusting the valve will regulate ow rate.
• When the valve is turned clockwise, ow rate will reduce;
when turned anti-clockwise, ow rate will increase.
After Use
• Turn the ow valve to the OFF position after each fogging
application while the motor is still operating to allow the
clearing of the lines.
• Turn off the appliance before unplugging. Unplug by grasp-
ing the plug, do not pull on the lead to unplug. Do not unplug
the fogger with wet hands.
• Clean the Air Intake Filter after each application. If the lter
becomes saturated while the fogger is in operation, switch it
off and clean the lter.
• Formulation should not be stored in the tank.The tank should
be cleaned after each use with hot water with a detergent
solution and ushed thoroughly with clean water before re-
use. To ensure a full ush, fully open the valve and operate
the fogger for 3 to 5 minutes.
Wiring Instructions
The wires in the mains lead are coloured in accordance with the fol-
lowing code:
BLUE = NEUTRAL
BROWN = LIVE
YELLOW & GREEN = EARTH
As the colours of the wire in the mains lead of this appliance may
not correspond with the colour marking identifying the terminals on
your plug, proceed as follows:
• The wire which is coloured BLUE must be connected to the
terminal which is marked with the letter N.
• The wire which is coloured BROWN must be connected to the
terminal which is marked with the letter L.
• The wire which is coloured YELLOW & GREEN must be con-
nected to the terminal which is marked with the letter E or
the symbol .
For UK
This appliance is supplied tted with a BS1363 mains plug and a
BS1362 10A fuse. If this plug is removed from the appliance, please
ensure it is disposed of safely as a disconnected plug is dangerous
if reconnected to the mains. If any other type of plug is used, a 10A
fuse must be tted.
For EU
This appliance is supplied tted with a Schuko mains plug. If this
plug is removed from the appliance, please ensure it is disposed
of safely as a disconnected plug is dangerous if reconnected to the
mains.
For private households: Information on Disposal
for Users of WEEE
This symbol (Figure. 1) on the product(s) and / or
accompanying documents means that used electrical
and electronic equipment (WEEE) should not be
mixed with general household waste.
For proper treatment,recovery and recycling, please take this product
(s) to designated collection points where it will be accepted free of
charge.
Alternatively, in some countries, you may be able to return your
products to your local retailer upon purchase of an equivalent new
product.
Disposing of this product correctly will help save valuable resources
and prevent any potential negative effects on human health and the
environment, which could otherwise arise from inappropriate waste
handling.
Please contact your local authority for further details of your nearest
designated collection point.
Penalties may be applicable for incorrect disposal of this waste, in
accordance with your national legislation.
For professional users in the European Union
If you wish to discard electrical and electronic equipment (EEE),
please contact your dealer or supplier for further information.
For disposal in countries outside of the European Union
This symbol is only valid in the European Union (EU). If you wish to
discard of this product, please contact your local authorities or dealer
and ask for the correct method of disposal.
Figure. 1
Pelsis UK Contact Number: +44 (0) 800 988 5359
Pelsis Belgium Contact Number: +32 (0) 3 886 22 11
USER GUIDE
Pelsis Ltd
Sterling House, Grimbald Crag Close,
Knaresborough, HG5 8PJ, UK
Pelsis Belgium NV
Industrieweg 15, 2880
Bornem, Belgium
Pelsis Belgium NV
Industrieweg 15, 2880
Bornem, Belgium
Other manuals for Curtis Dyna-Fog Hurricane
1
Other Pelsis Insect Control Equipment manuals

Pelsis
Pelsis INSECT-O-CUTOR HALO AQUA HL2X45IPX User manual

Pelsis
Pelsis LURALITE PLUS R4 User manual

Pelsis
Pelsis Insect-O-Cutor Halo Curve User manual

Pelsis
Pelsis Synergetic Halo 15W User manual

Pelsis
Pelsis Green Protect Fruit Fly Trap User manual

Pelsis
Pelsis Curtis Dyna-Fog Hurricane User manual

Pelsis
Pelsis CURTIS DYNA-FOG HURRICANE CL User manual

Pelsis
Pelsis B&G FLEX-A-LITE 2600 User manual