manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Pentair
  6. •
  7. Water Pump
  8. •
  9. Pentair MYERS ED-25 Guide

Pentair MYERS ED-25 Guide

INSTALLATION, OPERATION, & PARTS MANUAL
Model ED-25 Electric Drain
Sink Pump System
© 2013 Pentair, Inc. All Rights Reserved. 25581A050 (Rev. 02/05/13)
293 WRIGHT STREET, DELAVAN, WI 53115 WWW.FEMYERS.COM
PH: 888-987-8677
Warranty void if product modified, drilled,
painted, or altered in any way; if used to pump hot water, or
to pump liquids other than water (such as but not limited to
chemicals, fertilizers, flammable liquids, herbicides, mud,tar,
cement, wood chips); or otherwise abused.
The Model ED-25 Sink Pump System is especially designed for
pumping wastewater from laundry trays, washing machines,
wet bars, water softeners, dehumidifiers, etc. This pump system
can not be used for laundry/dishwasher applications in a
commercial or industrial environment.
California Proposition 65 Warning
This product and related accessories contain
chemicals known to the State of California to cause cancer, birth
defects or other reproductive harm.
INSTALLATION INSTRUCTIONS
Pump power cord is coiled inside the basin for
shipment. Remove the extra cord from the basin before operation.
Diagrams 1 and 2 show the various connections that must be
made for proper installation and operation. This is only a guide –
actual installation may vary depending on the
particular situation.
Inlet: A 1½” inlet is provided on the ED-25 Sink Tank System.
One method of hook up is to use a 1½” PVC MIP adapter
or a 1½” PVC MIP marvel connection (or a similar type of
connection). You may use a 1½” extension tail piece or 1½” PVC
pipe, it depends on the type of fittings used on the basin inlet. A
P-trap should be installed once the appropriate connections are
made on the basin inlet. Once these fittings are installed the rest
of the piping may be plumbed.
Vent: Provision has been made for a 2” vent to allow maximum
volume for any application and proper operation of pump. The
vent may be reduced to no less than 1¼”.
Venting is essential for proper pump operation and should not
be omitted. The ED-25 Sink Pump System may be vented into an
existing vent stack or use a BOCCA approved in-line vent. Any
other fixtures in the system must be vented separately from the
ED-25 Sink Pump System. Be sure to comply with local codes.
Discharge: Do not restrict discharge line below 1¼”. A check
valve MUST be installed to prevent back flow of water after each
cycle. If you are using 1½” or 1¼” PVC pipe on the discharge
line, a Myers CV-170 check valve is recommended. Once check
valve has been installed plumb the discharge line into an
existing drain line.
Basin: Myers Model ED-25 Sink Pump System includes a
corrosion-resistant polypropylene tank with a gasketed cover. An
inlet strainer is provided in the basin cover above the inlet. The
strainer is sealed and held in place with the four thumb
screws provided.
MAINTENANCE
Always disconnect pump from the electrical
power source before doing any maintenance.
Your sink pump system is manufactured for easy maintenance.
Each unit is individually factory-tested to ensure proper
adjustment and operation. If unit fails to operate properly,
carefully read instructions again to make sure correct procedure
has been followed.
Note: The basin strainer requires routine maintenance.
The strainer should be removed and cleaned monthly to
prevent clogging.
ELECTRICAL INFORMATION
SP25V1 pump is 6.5 amps.
Risk of electrical shock. This pump is supplied
with a grounding conductor and grounding type attachment
plug. To reduce risk of electrical shock, connect only to a
properly grounded grounding-type receptacle. This pump has
not been investigated for use in swimming pool areas. DO NOT
WORK ON PUMP UNTIL POWER IS UNPLUGGED. DO NOT cut
off ground pin or use an adapter fitting. DO NO use an extension
cord. The pump power cord should be connected to a separately
fused, grounded 115 volt line with a minimum capacity of
15 amps. NEVER touch the pump when it is connected to
electrical power.
The receptacle should be located at least 4 feet above floor level.
When wiring this pump follow all local electrical and safety
codes and ordinances as well as the most recent National
Electrical Code (NEC-ANSI/NFPA 70)
Ref. No. Description Part Number Quantity
A Basin Cover 25540C001 1
B Basin Bottom 25530C000 1
C Kit, Strainer, Strainer Cover, Strainer Gasket,
Screws, Basin Gasket & Cover Screws
25540C002 1
D Pump, SP25V1 with Switch 24683D050 1
E KC-011 Switch & Bracket 26262D100K 1
F Pipe, Discharge 25624A002 1
G Ring, "O" 1-3/4 x 1-15/16 x 3/32 05876A244 1
Limited Warranty
F.E. MYERS warrants to the original consumer purchaser (“Purchaser” or “You”) of the products listed below, that they will be free from defects
in material and workmanship for the Warranty Period shown below.
Product Warranty Period
Jet pumps, small centrifugal pumps, submersible pumps and
related accessories
whichever occurs first:
12 months from date of original installation,
or 18 months from date of manufacture
Fibrewound Tanks 5 years from date of original installation
Steel Pressure Tanks 5 years from date of original installation
Sump/Sewage/Effluent Products 12 months from date of original installation,
or 24 months from date of manufacture
Our warranty will not apply to any product that, in our sole judgement, has been subject to negligence, misapplication, improper installation, or
improper maintenance. Without limiting the foregoing, operating a three phase motor with single phase power through a phase converter will
void the warranty. Note also that three phase motors must be protected by three-leg, ambient compensated, extra-quick trip overload relays of
the recommended size or the warranty is void.
Your only remedy, and F.E. MYERS’s only duty, is that F.E. MYERS repair or replace defective products (at F.E. MYERS’s choice). You must pay all
labor and shipping charges associated with this warranty and must request warranty service through the installing dealer as soon as a problem
is discovered. No request for service will be accepted if received after the Warranty Period has expired. This warranty is not transferable.
F.E. MYERS SHALL NOT BE LIABLE FOR ANY CONSEQUENTIAL, INCIDENTAL, OR CONTINGENT DAMAGES WHATSOEVER.
THE FOREGOING LIMITED WARRANTIES ARE EXCLUSIVE AND IN LIEU OF ALL OTHER EXPRESS AND IMPLIED WARRANTIES, INCLUDING
BUT NOT LIMITED TO IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. THE FOREGOING LIMITED
WARRANTIES SHALL NOT EXTEND BEYOND THE DURATION PROVIDED HEREIN.
Some states do not allow the exclusion or limitation of incidental or consequential damages or limitations on the duration of an implied
warranty, so the above limitations or exclusions may not apply to You. This warranty gives You specific legal rights and You may also have other
rights which vary from state to state.
This Limited Warranty is effective June 1, 2011 and replaces all undated warranties and warranties dated before June 1, 2011.
F.E. MYERS
293 Wright Street, Delavan, WI 53115
Phone: 888-987-8677 • Fax: 800-426-9446 • www.femyers.com
In Canada: P. O. Box 9138, 269 Trillium Dr., Kitchener, Ontario N2G 4W5
Phone: 519-748-5470 • Fax: 888-606-5484

Other Pentair Water Pump manuals

Pentair MYERS C40-20 Manual

Pentair

Pentair MYERS C40-20 Manual

Pentair Aurora 770 Manual

Pentair

Pentair Aurora 770 Manual

Pentair MYERS MUSP125 User manual

Pentair

Pentair MYERS MUSP125 User manual

Pentair BERKELEY LTH Series User manual

Pentair

Pentair BERKELEY LTH Series User manual

Pentair AERMOTOR SPCM Series Owner's manual

Pentair

Pentair AERMOTOR SPCM Series Owner's manual

Pentair HYPRO 1532C-6SP Use and care manual

Pentair

Pentair HYPRO 1532C-6SP Use and care manual

Pentair PENTEK DEFENDER CSC-LINK User manual

Pentair

Pentair PENTEK DEFENDER CSC-LINK User manual

Pentair Hydromatic W-A1 Manual

Pentair

Pentair Hydromatic W-A1 Manual

Pentair STA-RITE DOMINATOR User manual

Pentair

Pentair STA-RITE DOMINATOR User manual

Pentair Sta-Rite J Series User manual

Pentair

Pentair Sta-Rite J Series User manual

Pentair MYERS WG75HH User manual

Pentair

Pentair MYERS WG75HH User manual

Pentair ONGA 112 Series User manual

Pentair

Pentair ONGA 112 Series User manual

Pentair MYERS MWS550110T Guide

Pentair

Pentair MYERS MWS550110T Guide

Pentair MW50 Series User manual

Pentair

Pentair MW50 Series User manual

Pentair HYDROMATIC CSS-3D User manual

Pentair

Pentair HYDROMATIC CSS-3D User manual

Pentair Challenger User manual

Pentair

Pentair Challenger User manual

Pentair Myers 125B Manual

Pentair

Pentair Myers 125B Manual

Pentair Myers CMP Series Troubleshooting guide

Pentair

Pentair Myers CMP Series Troubleshooting guide

Pentair HYPRO 1542A-65SP Series Use and care manual

Pentair

Pentair HYPRO 1542A-65SP Series Use and care manual

Pentair JET User manual

Pentair

Pentair JET User manual

Pentair Myers 125B User manual

Pentair

Pentair Myers 125B User manual

Pentair Aurora Edwards 150 User manual

Pentair

Pentair Aurora Edwards 150 User manual

Pentair Berkeley LTHH Series User manual

Pentair

Pentair Berkeley LTHH Series User manual

Pentair Hydromatic H3HX Manual

Pentair

Pentair Hydromatic H3HX Manual

Popular Water Pump manuals by other brands

Graco Bulldog instructions

Graco

Graco Bulldog instructions

DYI SHENG DS20-S-01 operating manual

DYI SHENG

DYI SHENG DS20-S-01 operating manual

Xylem FLOJET G257 Series manual

Xylem

Xylem FLOJET G257 Series manual

BUSCH COBRA Oxygen NC 0400 B instruction manual

BUSCH

BUSCH COBRA Oxygen NC 0400 B instruction manual

Grundfos Unilift AP12 Installation and operating instructions

Grundfos

Grundfos Unilift AP12 Installation and operating instructions

Doka CFT 700bar Original operating instructions

Doka

Doka CFT 700bar Original operating instructions

Becker KVT 3.140 operating instructions

Becker

Becker KVT 3.140 operating instructions

MayPole MP7956 user guide

MayPole

MayPole MP7956 user guide

MSW MSW-DENTPULLER.PW01 user manual

MSW

MSW MSW-DENTPULLER.PW01 user manual

Dover PSG Wilden Pro-Flo P220/AAPPP ENGINEERING OPERATION & MAINTENANCE MANUAL

Dover

Dover PSG Wilden Pro-Flo P220/AAPPP ENGINEERING OPERATION & MAINTENANCE MANUAL

ARO EXTRUSION PUMP NP623XXXXR8-XX Operator's manual

ARO

ARO EXTRUSION PUMP NP623XXXXR8-XX Operator's manual

KSB moviBOOST VP operating instructions

KSB

KSB moviBOOST VP operating instructions

Speck pumpen BN 10 A original operation manual

Speck pumpen

Speck pumpen BN 10 A original operation manual

Dwyer Instruments PHP Specification and operating instructions

Dwyer Instruments

Dwyer Instruments PHP Specification and operating instructions

BUSCH SIMPLEX operating instructions

BUSCH

BUSCH SIMPLEX operating instructions

SUNPUMPS SDS-Q Series Rebuild Instructions

SUNPUMPS

SUNPUMPS SDS-Q Series Rebuild Instructions

caprari K M150R Series Use and maintenance instructions

caprari

caprari K M150R Series Use and maintenance instructions

Aqua Computer AQUASTREAM XT USB User and operating manual

Aqua Computer

Aqua Computer AQUASTREAM XT USB User and operating manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.