For Installation of Electrical Controls at Equipment Pad (ON/OFF
Switches, Timers and Automation Load Center)
Installallelectricalcontrolsatequipmentpad,suchason/
oswitches,timers,andcontrolsystems,etc.toallowthe
operation(startup,shut-down,orservicing)ofanypump
orltersotheuserdoesnotplaceanyportionofhis/her
bodyoverornearthepumpstrainerlid,lterlidorvalve
closures.Thisinstallationshouldallowtheuserenough
spacetostandclearofthelterandpumpduringsystem
start-up, shut down or servicing of the system lter.
Pentair Water Pool and Spa®
IMPORTANT SAFETY INSTRUCTIONS
For Installation of Electrical Controls at Equipment Pad
(ON/OFF Switches, Timers and Automation Load Center)
Install all electrical controls at equipment pad, such as on/off
switches, timers, and control systems, etc. to allow the
operation (startup, shut-down, or servicing) of any pump or
filter so the user does not place any portion of his/her body
over or near the pump strainer lid, filter lid or valve closures.
This installation should allow the user enough space to stand
clear of the filter and pump during system start-up, shut down
or servicing of the system filter.
SAVE THESE INSTRUCTIONS
IMPORTANT PUMP WARNING AND SAFETY INSTRUCTIONS
Beforeservicingequipment,makenoteofthelterpressure.Besurethatall
controlsaresettoensurethesystemcannotinadvertentlystartduringservice.
Turnoallpowertothepump.IMPORTANT:Placeltermanualairreliefvalve
in the open position and wait for all pressure in the system to be relieved.
Beforestartingthesystem,fullyopenthemanualairreliefvalveandplaceall
systemvalvesinthe“open”positiontoallowwatertoowfreelyfromthetank
and back to the tank. Stand clear of all equipment and start the pump.
IMPORTANT: Do not close lter manual air relief valve until all pressure
has beendischarged fromthe valve and asteady stream of water appears.
Observelterpressuregaugeandbesureitisnothigherthanthepre-service
condition.
HAZARDOUSPRESSURE:STANDCLEAROFPUMP
AND FILTER DURING START UP
Circulationsystemsoperateunderhighpressure.When
anypartofthecirculatingsystem(i.e.lockingring,pump,
lter, valves, etc.) is serviced, air can enter the system
andbecomepressurized.Pressurizedaircancausethe
pump housingcover, lter lid,and valves toviolently
Pentair Water Pool and Spa®
IMPORTANT SAFETY INSTRUCTIONS
For Installation of Electrical Controls at Equipment Pad
(ON/OFF Switches, Timers and Automation Load Center)
Install all electrical controls at equipment pad, such as on/off
switches, timers, and control systems, etc. to allow the
operation (startup, shut-down, or servicing) of any pump or
filter so the user does not place any portion of his/her body
over or near the pump strainer lid, filter lid or valve closures.
This installation should allow the user enough space to stand
clear of the filter and pump during system start-up, shut down
or servicing of the system filter.
separatewhichcanresultinseverepersonalinjuryordeath.Filtertanklidand
strainercovermustbeproperlysecuredtopreventviolentseparation.Stand
clearofallcirculationsystemequipmentwhenturningonorstartinguppump.
General Installation Information
• Allworkmustbeperformedbyaqualiedserviceprofessional,andmust
conform to all national, state, and local codes.
• Install to provide drainage of compartment for electrical components.
• These instructions contain information for a variety of pump models
and therefore some instructions may not apply to a specic model.
All models are intended for use in swimming pool applications. The
pump will function correctly only if it is properly sized to the specic
application and properly installed.
• Installing a non-return valve after the pump on the installation will
prevent the impeller from unwinding and is strongly recommended.
Pumps improperly sized or installed or used in
applications other than for which the pump was
intendedcanresultinseverepersonalinjuryordeath.
Theserisksmayincludebutnotbelimitedtoelectricshock,re,ooding,
suction
entrapmentorsevereinjuryorpropertydamagecausedbyastructuralfailure
of the pump or other system component.
Thepumpcanproducehighlevelsofsuctionwithinthe
suctionsideoftheplumbingsystem.Thesehighlevels
of suction can pose a risk if a person comes within the close
proximityofthesuctionopenings.Apersoncanbeseriouslyinjuredbythishigh
level of vacuum or may become trapped and drown. It is
absolutelycriticalthatthesuctionplumbingbeinstalledinaccordancewiththe
latest national and local codes for swimming pools.
TheVirginia Graeme Baker (VGB) Pool and Spa Safety Act creates new
requirementsforownersandoperatorsofcommercialswimmingpools
and spas.
Commercial pools or spas constructed on or after December 19, 2008,
shall utilize:
(A) Amultiplemaindrainsystemwithoutisolationcapabilitywithsuction
outletcoversthatmeetASME/ANSIA112.19.8aSuctionFittingsforUsein
Swimming Pools, Wading Pools, Spas, and Hot Tubs and either:
(i)Asafetyvacuumreleasesystem(SVRS)meetingASME/ANSIA112.19.17
ManufacturedSafetyVacuumReleasesystems(SVRS)forResidentialand
CommercialSwimmingPool,Spa,HotTub,andWadingPoolSuctionSystems
and/orASTMF2387StandardSpecicationforManufacturedSafetyVacuum
Release Systems (SVRS) for Swimming pools, Spas and HotTubs or
(ii) A properly designed and tested suction-limiting vent system or
(iii) An automatic pump shut-o system.
CommercialpoolsandspasconstructedpriortoDecember19,2008,witha
singlesubmergedsuctionoutletshalluseasuctionoutletcoverthatmeets
ASME/ANSI A112.19.8a and either:
(A) A SVRS meeting ASME/ANSI A112.19.17 and/or ASTM F2387, or
(B) A properly designed and tested suction-limiting vent system, or
(C) An automatic pump shut-o system, or
(D) Disabled submerged outlets, or
(E) Suction outlets shall be re-congured into return inlets.
TOMINIMIZETHERISKOFINJURYDUETOSUCTION
ENTRAPMENT HAZARD:
• Each suction cover must be installed at least 1 m apart, as measured
from the nearest point to nearest point.
• Regularlyinspectallcoversforcracks,damageandadvancedweathering.
• If a cover becomes loose, cracked, damaged, broken or is missing,
replace with an appropriate certied cover.
• Replace draincovers asnecessary. Draincoversdeteriorate over time
due to exposure to sunlight and weather.
• Avoidgettinghair,limbsorbodyincloseproximitytoanysuctioncover,
pool drain or outlet.
• Disable suction outlets or recongure into return inlets.
A clearly labeled emergency shut-o switch for the
pump mustbe in aneasily accessible,obvious place.
Make sureusers know where it isand how touse it in
case of emergency.
English
BodyEntrapment:Whenaportionofthebodyisheldagainstthedraincover
trappingtheswimmerunderwater.Thishazardispresentwhenthedraincover
ismissing,brokenorthecoverowratingisnothighenoughforthepumpor
pumps.
Evisceration/Disembowelment:When a person sits on an open pool (par-
ticularlyachildwadingpool)orspaoutletandsuctionisapplieddirectlytothe
intestines,causingsevereintestinaldamage.Thishazardispresentwhenthe
drain cover is missing, loose, cracked, or not properly secured.
MechanicalEntrapment:Whenjewelry,swimsuit,hairdecorations,nger,toeor
knuckleiscaughtinanopeningofanoutletordraincover.Thishazardispresent
whenthedraincoverismissing,broken,loose,cracked,ornotproperlysecured.
NOTE: ALL SUCTION PLUMBING MUST BE INSTALLED IN
ACCORDANCEWITH THE LATEST NATIONAL AND LOCAL CODES,
STANDARDS AND GUIDELINES.
4