Perle 07013050 Manual

IDS-305G Hardware Installation Guide
Managed Industrial Ethernet Switches
Updated: September 2016
Revision 1.00
Document Part#: 5500401-10
www.perle.com

Table of Contents
Preface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
Switch Model View . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
LED Indicators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
Ports . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
Port Status Indicators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
Cautions and Warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
Terminal Block-Power Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
Connecting the Console Port . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11
Connecting Destination Ports . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
Resetting the Switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13
Booting the Switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14
Fast Setup Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14
Password Recovery . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14
Configuring the IDS Switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15
Appendix A - Technical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16
Appendix B - Labels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18
Appendix C - Mechanical Drawings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19
Appendix D - IDS DIN Rail and Wall Mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20
Appendix E - IDS Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .22
Appendix F - Cables and Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .23

IDS-305G Hardware Installation Guide
THE SPECIFICATIONS AND INFORMATION REGARDING THE PRODUCTS IN THIS GUIDE ARE SUBJECT TO CHANGE
WITHOUT NOTICE. ALL STATEMENTS, INFORMATION, AND RECOMMENDATIONS IN THIS GUIDE ARE BELIEVED TO BE
ACCURATE BUT ARE PRESENTED WITHOUT WARRANTY OF ANY KIND, EXPRESS OR IMPLIED. USERS MUST TAKE
FULL RESPONSIBILITY FOR THEIR APPLICATION OF ANY PRODUCTS.
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC
rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a
commercial environment. This equipment generates, uses, and can radiate radio-frequency energy and, if not installed and used in
accordance with this hardware guide may cause harmful interference to radio communications. Operation of this equipment in a
residential area is likely to cause harmful interference, in which case users will be required to correct the interference at their own
expense.
Modifications to this product not authorized by Perle could void the FCC approval and negate your authority to operate the product.
Perle reserves the right to make changes without further notice, to any products to improve reliability, function, or design.
Perle, the Perle logo, and IDS Switch are trademarks of Perle Systems Limited.
©2016. Perle Systems Limited.

2
IDS-305G Hardware Installation Guide
Preface
Audience
This guide is for the network or computer technician responsible for installing Perle IDS-305 series
switches. We assume that you are familiar with the concepts and terminology of Ethernet and local area
networks.
Purpose
This document describes the hardware and physical characteristics of the Perle IDS switch. It covers
hardware features as well as installation and operation of the switch. This document does not cover how
to configure your Perle IDS switch. Information to configure your Perle IDS switch can be found in the
Perle IDS User’s Guide
Package Contents
• IDS switch with attached DIN rail mounting bracket
• Quick Start Guide
Document Conventions
This document contains the following conventions:
Most text is presented in the typeface used in this paragraph. Other typefaces are used to help you
identify certain types of information. The other typefaces are:
Note: Means reader take note: notes contain helpful suggestions.
Caution: Means reader be careful. In this situation, you might perform an action that could result in
equipment damage or loss of data.
Warning: IMPORTANT SAFETY INSTRUCTIONS
Means danger. You are in a situation that could cause bodily injury. Before you work on any equipment,
be aware of the hazards involved with electrical circuitry and be familiar with standard practices for
preventing accidents. Only qualified personnel should connect power to this unit.

3
IDS-305G Hardware Installation Guide
Overview
This chapter discusses the following topics:
• LED Indicators
• Switch Model View
•Ports
• Port Status Indicators
The table below gives a brief overview of the models covered in this guide. For more details and for the
most up-to-date list of models, please refer to the product pages at www.perle.com.
Note: xxxxxx denotes the specific type of fiber port installed. Refer to the Perle Website for up to date
details on the available options.
Standard Models Port 1-4 Port 5 Temp
IDS-305G-XXXXXX 10/100/1000Base-T (RJ45) 1000Base-X SC/ST fiber Standard
IDS-305G-XXXXXX-XT 10/100/1000Base-T (RJ45) 1000Base-X SC/ST fiber Industrial

4
IDS-305G Hardware Installation Guide
Switch Model View
IDS-305G
Note: Fiber Port may appear different, depending on the type of fiber port installed.

IDS-305G Hardware Installation Guide
LED Indicators
P (Power Inputs)
Sys (System Status)
Alr (Alarm)
BC (Backup Coupling)
State Description
Green P1 and P2 Power inputs within specifications
Yellow P1 or P2 Providing power within specifications
Red Neither P1 or P2 providing power within specifications
State Description
Green - blinking (after power on) System booting
Green - solid System ready/operating normally
Green - blinking slowly Fast Setup Mode activated/port available
Green - blinking fast Fast Setup Mode activated/no port available
Red Hardware fault or firmware load error
State Description
Off No alarms configured
Green - solid Alarms configured, but no alarms detected
Red - solid Alarm condition detected
Red - blinking Alarm condition detected and Alarm Relay activated
State Description
Off Backup Coupling not enabled
Green - solid Backup Coupling Link enabled

LED Indicators 6
IDS-305G Hardware Installation Guide
RM (Ring Master)
5 (Port 5 - Fiberport Link/Activity)
State Description
Off Ring Master not activated
Green - solid Ring Master Active, redundant port blocked. Coupling Link
enabled
Green - flashing Ring Master unabletoestablish a ring due to missing link on
one of the Ring ports
Yellow - solid Ring Master Active,redundant port unblocked - indicates a
break in the Ring
State Description
Off Link Down
Green - blinking Link and activity
Green - blinking slowly Port in error disable or suspended state

7
IDS-305G Hardware Installation Guide
Ports
10/100/1000Base-T Ports
These ports provide the standard gigabit Ethernet interface. They provide speeds of 10/100 or
1000 Mb/s through twisted pair (UTP) cables of up to 100 meters (328ft) in length.
RJ-45 Console Port
This is a console management port which will provide access to the switch management function using
our industry standard CLI command set. This port has an RJ-45 connector. See RJ-45-Console Port Pin-
outs for pinouts.
1000Base-X SC/ST Fiber Ports
These ports provide a built in fiber module that provides fiber connectivity at 100 Mb/s. These fiber
ports are available on the switches in a variety of distances, wavelengths and connector types. Consult
the full model list at www.perle.com.
Power Connector
The power input connector has provisions for dual inputs. Two independent power sources can be used
to power the switch. If one power input fails, the other power input will power the switch.
Alarm Relay Connector
The Alarm Relay can be energized by the software or hardware under certain conditions. It can then be
used to trigger an external alarm circuit such as a light or sounding device. This connector provides a
Normally Closed (NC) dry contact on the connector block.

8
IDS-305G Hardware Installation Guide
Port Status Indicators
Ethernet Port Status Indicators
Port Link / Speed (Green and Yellow LEDs)
State Description
Green 1000 Mbps
Green / Yellow 100 Mbps
Yellow 10 Mbps
On solid Port Link
Random blinking Port Link and Activity
Slow blinking Error disabled
Rapid blinking Port in Fast Setup Mode
This manual suits for next models
2
Table of contents
Other Perle Switch manuals

Perle
Perle IDS-509G User manual

Perle
Perle RPS1620 User manual

Perle
Perle IDS-409F User manual

Perle
Perle IDS-205 User manual

Perle
Perle IDS-205F User manual

Perle
Perle IDS-305 User manual

Perle
Perle IDS-409 User manual

Perle
Perle IDS-105F User manual

Perle
Perle IDS-509G2 Series Manual

Perle
Perle IDS-509G Manual

Perle
Perle IDS-409G User manual

Perle
Perle JETSTREAM 8500 Quick guide

Perle
Perle IDS-509-SFP User manual

Perle
Perle IDS-509G2PP6 Manual

Perle
Perle IDS-108F User manual

Perle
Perle IDS-206 User manual

Perle
Perle IOLAN SDG4 W User manual

Perle
Perle IOLAN SDG2 W User manual

Perle
Perle IDS-509-2SFP Manual

Perle
Perle IDS-105G User manual