PART 7: BEFORE CALLING YOUR AFTER SALES SERVICE
Alarm
indicator led
is turning on
ERROR TYPE WHY WHAT TO DO
„Failure Warning"
There is/are some part(s) Out
of order or there is a failure in
cooling process.
The product is plugged for
thersttimeoralong-time
power interruption for 1 hour.
Check the door is open or
not and check if the product
working 1 hour. If the door is
not open and the product had
worked 1 hour, call service for
assistance as soon as possible.
If your fridge is not working properly, it may be a minor problem, therefore check the following, before calling
an electrician to save time and money.
What to do if your appliance does not operate;
Check that;
• Thereisnopower,
• Thegeneralswitchinyourhomeisdisconnected,
• Thesocketisnotsucient.Tocheckthis,pluginanotherappliancethatyouknowwhichisworkinginto
the same socket.
What to do if your appliance performs poorly;
Check that;
• Youhavenotoverloadedtheappliance,
• Thefridgetemperaturesetto2.
• Thedoorisclosedperfectly,
• Thereisnodustonthecondenser,
• Thereisenoughplaceattherearandsidewalls.
If your fridge is operating too loudly;
Normal Noises
Cracking (Ice cracking) Noise:
• Duringautomaticdefrosting.
• Whentheapplianceiscooledorwarmed(duetoexpansionofappliancematerial).
Short cracking: Heard when the thermostat switches the compressor on/ o.
Compressor noise: Normal motor noise. This noise means that the compressor operates normally
Compressor may cause more noise for a short time when it is activated.
Bubbling noise and splash: This noise is caused by the ow of the refrigerant in the tubes of the system.
Water flow noise: Normal ow noise of water owing to the evaporation container during defrosting.
This noise can be heard during defrosting.
Air Blow Noise: Normal fan noise. This noise can be heard in No-Frost freezer during normal operation of the
system due to the circulation of air.
If the edges of fridge cabinet that the door joint contact are warm;
Especially in summer (hot weather), the surfaces that the joint contact may get warmer during the operation
of the compressor, this is normal.