631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
www.lightolier.com © 2010 Philips Group • A0910
Lytecaster Performance Recessed Downlighting 1001
Page 2 of 2 5" Aperture Vertical Open, Performance Series, Reflector Trim
Job Information Type:
Zonal Lumens And Percentages
Zone Lumens %Lamp %Fixt
0-30 415.94 24.3 45.2
0-40 659.16 38.5 71.7
0-60 918.96 53.7 99.9
0-90 919.93 53.8 100
90-120 0 0 0
90-130 0 0 0
90-150 0 0 0
90-180 0 0 0
0-180 919.93 53.8 100
** Efficiency = 53.8% **
Zonal Lumen Summary
Zone Lumens
0-10 47.69
10-20 143.32
20-30 224.93
30-40 243.22
40-50 196.58
50-60 63.22
60-70 .97
70-80 0
80-90 0
90-100 0
100-110 0
110-120 0
120-130 0
130-140 0
140-150 0
150-160 0
160-170 0
170-180 0
1101CL HID 70W ED-17 LAMP
26W TRIPLE TUBE LAMP, LUMEN RATING = 1710 LMS, ELECTRONIC BALLAST, CL FINISH TRIM
Coefficients Of Utilization
Ceiling 80% 70% 50% 30% 0
Wall 70 50 30 10 50 10 50 10 50 10 0
RCR Zonal Cavity Method - Effective Floor Reflectance = 20%
Room Cavity Ratio
0 56 56 56 56 55 55 52 52 50 50 47
1 53 51 50 49 50 48 48 47 47 45 43
2 50 47 45 43 46 42 44 41 43 40 39
3 46 43 40 38 42 37 41 37 40 36 35
4 43 39 36 34 39 33 37 33 36 33 31
5 41 36 33 30 35 30 34 30 34 29 28
6 38 33 30 27 33 27 32 27 31 27 26
7 36 30 27 25 30 25 29 24 29 24 23
8 33 28 25 22 28 22 27 22 27 22 21
9 31 26 23 21 26 21 25 20 25 20 20
10 30 24 21 19 24 19 24 19 23 19 18
Determined In Accordance With Current IES Published Procedures
Luminaire Input Watts = 33.0
Coefficients Of Utilization
Ceiling 80% 70% 50% 30% 0
Wall 70 50 30 10 50 10 50 10 50 10 0
RCR Zonal Cavity Method - Effective Floor Reflectance = 20%
Room Cavity Ratio
0 64 64 64 64 63 63 60 60 57 57 54
1 60 59 57 59 58 55 55 53 53 52 49
2 57 54 51 49 53 48 51 47 49 46 44
3 53 49 46 43 48 43 47 42 45 41 40
4 49 45 38 44 38 43 37 42 37 36 41
5 46 41 37 34 40 34 39 34 38 33 32
6 43 37 33 31 37 31 36 30 35 30 29
7 40 34 30 28 34 28 33 27 33 27 26
8 38 32 28 25 31 25 31 25 30 25 24
9 36 29 26 23 29 23 28 23 28 23 22
10 33 27 24 21 27 21 27 21 26 21 20
Determined In Accordance With Current IES Published Procedures
Luminaire Input Watts = 27.0
Candlepower Distribution
Angle Mean CP
01520
51581
10 1405
15 1274
20 1230
25 1153
30 1023
35 880
40 734
45 595
50 418
55 169
60 12
65 5
70 3
75 2
80 2
85 1
90 1
Candlepower Distribution
Angle 0° CP
0481
5496
10 507
15 500
20 512
25 492
30 449
35 392
40 324
45 258
50 178
55 56
60 4
65 1
70 1
75 0
80 0
85 0
90 0
Candlepower Distribution
Angle 0° CP
0393
5405
10 413
15 409
20 418
25 399
30 361
35 307
40 249
45 192
50 114
55 40
60 3
65 1
70 0
75 0
80 0
85 0
90 0
Trim/Frame: 1001CL
Lamp lumens: 4700 lm
Input Watts: 83 W
Efficiency: 47.0 %
Spacing Criterion: 1.06
Multiple Unit Data - RCR 2
Spacing Avg.Initial Watts/
On Ctr. Footcandles Sq. Ft.
6' 55 2.07
8' 38 1.44
10' 24 0.92
38'x38'x10' Room, Workplane 2 1/2'
above floor, 80/50/20% Reflectances
Single Unit Data
Height to Initial Beam
Lighted Plane Footcandles Diameter
6' 42 6'
8' 24 8'
10' 15 11'
12' 11 13'
Zonal Lumens And Percentages
Zone Lumens %Luminaire
0-30 1035 47.0%
0-40 1583 72.0%
0-60 2202 99.0%
0-90 2211 100.0%
CERTIFIED TEST REPORT NO. 4067FR
SC = 1.3
CERTIFIED TEST REPORT NO. 3067FR
COMPUTED BY LSI PROGRAM
**TEST-LITE**
500
1000
1500
150
300
450
60˚
60˚
30˚
30˚
Zonal Lumens And Percentages
Zone Lumens %Lamp %Fixt
0-30 338.39 28.2 47.2
0-40 529.08 44.1 73.8
0-60 715.78 59.6 99.8
0-90 716.88 59.7 100
90-120 0 0 0
90-130 0 0 0
90-150 0 0 0
90-180 0 0 0
0-180 716.88 59.7 100
** Efficiency = 59.7% **
Zonal Lumen Summary
Zone Lumens
0-10 38.92
10-20 117.03
20-30 182.44
30-40 190.69
40-50 144.07
50-60 42.62
60-70 1.11
70-80 0
80-90 0
90-100 0
100-110 0
110-120 0
120-130 0
130-140 0
140-150 0
150-160 0
160-170 0
170-180 0
18W TRIPLE TUBE LAMP, LUMEN RATING = 1200 LMS, ELECTRONIC BALLAST, CL FINISH TRIM
Coefficients Of Utilization
Ceiling 80% 70% 50% 30% 0
Wall 70 50 30 10 50 10 50 10 50 10 0
RCR Zonal Cavity Method - Effective Floor Reflectance = 20%
Room Cavity Ratio
0 71 71 71 71 69 69 66 66 64 64 60
1 67 65 64 62 64 61 62 59 59 57 55
2 63 60 57 54 59 54 57 53 55 51 49
3 59 55 51 48 54 48 52 47 50 46 44
4 55 50 46 43 49 43 48 42 47 42 40
5 52 46 42 38 45 38 44 38 43 38 36
6 48 42 38 35 41 35 40 34 40 34 33
7 45 39 34 31 34 31 37 31 37 31 30
8 42 36 31 29 35 29 35 28 34 28 27
9 40 33 29 26 33 26 32 26 32 26 25
10 38 31 27 24 31 24 30 24 29 24 23
Determined In Accordance With Current IES Published Procedures
Luminaire Input Watts = 27.0
SC = 1.3
CERTIFIED TEST REPORT NO. 3066FR
COMPUTED BY LSI PROGRAM
**TEST-LITE**
125
250
375
500
60˚
30˚