Power-Grid Connection Instructions
If you have chosen xed power grid connection for installing your heating unit, please
commission a professional to carry the installation out on your behalf. For this type of
installation, the following instructions must be adhered to:
•The heating unit must be connected to a power grid by means of a power cord with
a correct and sucient current capacity.
•Attach the power cord wire ends to the relevant clips on the heater as indicated.
•Right from the external casing of the electrical clips the power cord must lead vertically
straight up towards the ceiling, parallel to the chains. The power cord may never be left
lying on the heater while its surface is hot—the cable would come to harm.
•Make sure the correct polarity is observed.
•When connecting the unit to a power grid while using a thermostat the installation must
be carried out in compliance with the instructions provided by its manufacturer.
•The thermostat should be mounted 1.5 meters above the oor. When selecting its posi-
tion, avoid draught and such zones that would put the thermostat under direct impact
of heat rays or other types of heat sources, should you wish to avoid malfunctions.
Unit Operation and Maintenance
The heating unit you have purchased basically does not require any maintenance or
service. There are only two tasks necessary for ensuring its continuous reliable operation
over the years:
•If dusty, use a wet cloth to clean the casing and use industrial alcohol for wiping the
heat-emitting panel (only when the heater is o and cool).
•Once a year, prior to the heating season, check whether the wire contacts of the power
cord are in working condition and make sure the clip connectors have not come loose.
9
The infrared heater may only be used under the following conditions:
•The ambient temperature must be between -50 °С to +50 °С.
•Relative air humidity at a temperature of 25 °С must not exceed 80% .
Problem Solution Tips
Insucient
heating
performance
• Check what the voltage is on the unit’s terminal clamps, the values should read
230 V +/- 10 V when in operation.
• Make sure that the thermostat is in perfect condition.
• Compare the values indicated on the thermostat with the reading of your
standard indoor thermometer, duly located next to the thermostat. The devia-
tion in thermostat start-up must fall within the range of +/- 2 °C.
The unit does
not heat •Make sure there is power in the power grid.
• Check whether the power cord is intact.
• Check all contacts at the unit’s terminal board.
• Check the power plug contact points .
• See whether the thermostat is working properly.
• Turn to authorized dealers for help.
The heater should be stored in its original package on such premises where temperature ran-
ges between -50 °С and +50° С and air humidity does not exceed 80%. The heater should be
safeguarded against banging, dust and moisture. The heat-emitting panel should be treated
and handled with extra care; don’t touch its surface. Should it ever get stained then you may
wipe it with industrial alcohol.
Storage Instructions
Troubleshooting
A Diagram Illustrating the Installation Scheme with the Use of a Thermostat
automatic power switch
neutral conductor N
phase L1
ground conductor
N 1 2
phase L1
ground conductor neutral conductor N
infrared heating
thermostat