Plasson Super Easy Start
Adjustable For Turkey Poults
(Up to 7 weeks)
Operation Instructions
Global Presence - Local Commitment
2012
4. After taking the birds out:
• CleanthelinesfollowingPlassonGuidetoCleaningWaterLines
• Keepthelineslledwithwaterexceptunderfreezingconditions
1. Check your installation:
• Aftercompletingtheinstallation,llthelinesinordertocheckthe
system.
• TheSESAsystemisassembledonthePlassonNipplesystem.
• Alwaysusethelongconnectingpiece(02209015)forthe
Aluminumprole.
• Nippletypeforthisapplication:Grey.
• RecommendednumberofTurkeyPoultsperSESA:25-30.
• RecommendednumberofSESAper3m(10’)section:4-6.
• Maximumlengthofline80m(260ft.).Forlongerlines,aPlasson
MidLinePressureRegulatorcanbeused.
• Ifwaterissuppliedfromthemainpipeline,incomingpressureto
theheaderkitshouldbe1.5bar(22psi),
max.2.7bar(40psi).
• Ifwaterissuppliedfromaheadertank,theheadertankshouldbe
atleast4m(13ft.)aboveoorlevel.
• A130micronor120meshltercartridgeorbettermustbe
installedbeforetheheaderkit.
• Linesmustbesuspendedataconstantheightabovethehouse
oor(slats/litter).
• Forlineswithmorethan15cm(6”)offallorslope,besureto
installtheheaderkitonthehighendofthelineandallowthe
watertoowdownward.Maximumpermitteddropoflinewithout
usingPlassonSlopeRegulator:15cm(6”).
• Shockerwiremustbeinstalled.Thealuminumprolemustbe
grounded.Itisrecommendedtoperformthegroundingusing
PlassonGroundingNipple.
2. Before operating the system and prior to placement of
birds:
• Atthestartofeachnewockandaftermedication,thesystem
mustbeushedthoroughlywithhighpressure,onelineatatime
(fordetailsseePlassonGuidetoCleaningWaterLines).Toush:
° Opendrainvalveatendofline
° TurnvalveonPressureRegulatorto“ush”position(halfturn)
° Wesuggestaminimumof10minutesperline.Oncecompleted,
turnthevalveto“regulate”positionandclosedrainvalveatthe
endoftheline.
• Setthewaterpressure(initialsetting)to30cm(12”).(Waterlevel
insighttubeshouldbemeasuredfromthecenteroftheNipple
linepipe)
3. During the ock:
• ItisveryimportantthattheTurkeyPoultswillbeabletoseethe
waterintheSESA-adjusttheheightoftheSESAlineandthelight
programaccordingly.
• Recommendedwaterpressure:25-40cm(10"-16").
• Trainingtowardsgrowout:
°IfnishingbarnisequippedwithHF*werecommendadding
oneHFper3m(10’)sectionforthelastweekofbrooding.
°IfthenishingisdoneinthesameshedandusingHF,we
recommendaddingoneHFper3m(10’)sectionfromthe3rd
weekofbroodingandcontinuereplacingtheSESAwithoneHF
everytwo/threedays(seeHFOperatinginstructions).Theextra
unusedNipplesshouldbecoveredwithPlassonSnaponPlug
forNipple(02205294).
°PlassonBellDrinker,lower5to10BellDrinkersperhousefor
thelastweekofbrooding.
• HeightofSESASystemguidelines:followthesketchhereunder
* HF(HeavyFinish)-PlassonNippleSystemforAdultTurkeys.
• Cleanthelterperiodicallyaccordingtowaterquality
• ItisgoodpracticetoruncleanwaterthroughtheMedicatorafter
eachmedication
Please read all the instructions before using the Plasson
Super Easy Start Adjustable for Turkey Poults system.
The following are general recommendations:
Adjust the line’s height
enabeling the Turkey
Poults to easily see the
water upon their first
search while ensuring
the cup does not touch
the litter as this will
cause it to flood.
Day 1
Slightly raise the water
lines in order to train
the birds to drink from
the raised SESA. The lip
of the SESA should be
at bird’s chest to eye
level.
Day 3 up to
6 days
Keep the SESA lip
slightly above eye level
while enabling free
movement under the
SESA.
7 days till
end of brooding