Plymovent Miniman-100 User manual

www.plymovent.com
Extraction arm
AB
AB
C
C
MINIMAN-100 | ATEX | TOPGR ADE
Installation and user manualEN

0000110292/010123/B MiniMan-100 | MiniMan-100 ATEX | MiniMan-100 TopGrade 1
PREFACE...................................................................................................................................2
1 INTRODUCTION..........................................................................................................2
2 PRODUCT DESCRIPTION .............................................................................................3
3 SAFETY ......................................................................................................................3
4 INSTALLATION ........................................................................................................... 5
5 USE ...........................................................................................................................6
6 MAINTENANCE ...........................................................................................................6
7 TROUBLESHOOTING ...................................................................................................7
8 SPARE PARTS .............................................................................................................7
9 DISPOSAL ..................................................................................................................7
CE DECLARATION......................................................................................................................7
EN | ORIGINAL INSTRUCTION
All rights reserved. The information given in this document has been collected for the general convenience of our clients. It has been based on general data pertaining to construction
material properties and working methods known to us at the time of issue of the document and is therefore subject at any time to change or amendment and the right to change or amend
is hereby expressly reserved. The instructions in this publication only serve as a guideline for installation, use, maintenance and repair of the product mentioned on the cover page of this
document. This publication is to be used for the standard model of the product of the type given on the cover page. Thus the manufacturer cannot be held responsible for any damage
resulting from the application of this publication to the version actually delivered to you. This publication has been written with great care. However, the manufacturer cannot be held
responsible, either for any errors occurring in this publication or for their consequences.
To improve comprehension for people whose rst language is not English, we have written parts of this manual in Simplied Technical English (STE). STE is a controlled
language originally developed for aerospace industry maintenance manuals. It offers a carefully limited and standardized subset of English, along with specic writing rules.
TABLE OF CONTENTS

0000110292/010123/B MiniMan-100 | MiniMan-100 ATEX | MiniMan-100 TopGrade 2
PREFACE
Using this manual
This manual is intended to be used as a work of reference for
professional, well trained and authorised users to be able to
safely install, use, maintain and repair the product mentioned
on the cover of this document.
Pictograms and symbols
The following pictograms and symbols are used in this manual:
TIP
Suggestions and recommendations to simplify
carrying out tasks and actions.
ATTENTION
A remark with additional information for the user. A
remark brings possible problems to the user’s
attention.
CAUTION!
Procedures, if not carried out with the necessary
caution, could damage the product, the workshop or
the environment.
WARNING!
Procedures which, if not carried out with the
necessary caution, may damage the product or
cause serious personal injury.
WARNING!
WARNING!
Explosion hazard! Important warning to prevent
explosions.
Personal protective equipment (PPE)
Instruction to use respiratory protection when you
do service, maintenance and repair jobs, as well as
during functional testing. We recommend to use a
half-face respirator according to EN 149:2001 +
A1:2009, class FFP3 (Directive 89/686/EEC).
Personal protective equipment (PPE)
Instruction to use protective gloves when you do
service, maintenance and repair jobs.
Text indicators
Listings indicated by “-” (hyphen) concern enumerations.
Listings indicated by “•” (bullet point) describe steps to
perform.
1 INTRODUCTION
1.1 Identication of the product
following data:
- product name
- serial number
1.2 General description
all types of smaller dust and fume applications.
design), which allows for maximum air velocity, low pressure
drop and low noise level. The inner tubes are kept in place by
a gas spring (standing arm) or a balancing strap (hanging
arm). This design ensures smooth movement of the arm.
The MiniMan-100
- type H: for hanging mounting
- type S: for standing mounting
- type TopGrade: white arm (hanging or standing), especially
suitable for use in clean working environments, such as
laboratories
- type ATEX: approved for use in explosive environments zone
1 and 21; marking Ex II 2G 2D (for hanging mounting only)1
1.3 Options and accessories
DAMPER-100
MiniMan-100 all types (except for ATEX versions)
S-100
LL-5.5/24-100
+ TR-24
transformer 230/24V
1.4 Product combinations
You can use the MiniMan-100 with the following products:
Extraction fan Suitable for
- FUA-2100 | 0,75 kW (1 HP)
- FUA-3000 | 1,1 kW (1½ HP)
- FUA-4700 | 2,2 kW (3 HP)
- 2-3 MiniMan arms
- 3-4 MiniMan arms
- 4-5 MiniMan arms
Stanchion
-
- PA-220-160 | 2,2 m (7¼ ft)
1.5 Technical specications
Physical dimensions and properties
Length (nom.):
- MM-100-1.5
- MM-100-2.1
- 1,5 m (5 ft.)
- 2,1 m (7 ft.)
Diameter Ø 100 mm (4 in.)
Material of tubes aluminium
Material of hoses:
- type H, S, Topgrade - PVC with internal steel spiral;
- type ATEX - PVC with internal steel spiral;
Weight (net):
- MM-100-1.5
- MM-100-2.1
- 9,5 kg (21 lbs.)
- 12 kg (26½ lbs.)
Arm rotation:
- type H, S, Topgrade
- type ATEX
- 360°
- max. 359° (due to the litz
wire)
Performance
-
200-450 m/h (118-265 CFM)
- 200 m/h (118 CFM)
1.6 Working reach
Refer to Fig. I on page 8.
1.7 Pressure drop
Refer to Fig. II on page 9.
Refer to the available product data sheet for
1. In accordance with TRGS 727 & ATEX Directive 2014/34/EU

0000110292/010123/B MiniMan-100 | MiniMan-100 ATEX | MiniMan-100 TopGrade 3
1.8 Ambient and proces conditions
Process temperature:
- min.
- nom.
- max.
5°C (41°F)
20°C (68°F)
70°C (158°F)
Max. relative humidity 90%
Outdoor use allowed no
2 PRODUCT DESCRIPTION
2.1 Components
The product consists of the following main components and
elements:
Fig. 2.1
A Mounting bracket
B Friction joint (2)
C Hose (3)
D Balancing strap
E Inner tube
F Outer tube
G Hood
H Gas spring
I Handle
A
B
B
C
C
C
A
B
I
G
G
I
B
F
F
H
D
E
E
C
C
C
MiniMan H
A
B
B
C
C
C
A
B
I
G
G
I
B
F
F
H
D
E
E
C
C
C
MiniMan S
Fig. 2.1 Main components and elements
2.1.1 MiniMan-100 ATEX
MiniMan-100 ATEX arms are suitable for use in potentially
explosive environments. They comply with ATEX directives due
to:
- antistatic hoses instead of standard hoses
- litz wires that interconnect the metal parts of the arm
2.2 Operation
The fume is extracted through the nozzle of the arm by an
extraction fan. The extraction arm discharges the polluted air
atmosphere.
2.2.1 Option: DAMPER-100 (sealed shut-o valve)
extraction arms are integrated in a line installation; in such
heated air. You can also use the valve to prevent fume from
3 SAFETY
General
The manufacturer does not accept any liability for
damage to the product or personal injury caused by
ignoring of the safety instructions in this manual, or
by negligence during installation, use, maintenance, and repair
of the product mentioned on the cover of this document and
used accessories may require additional safety instructions.
Immediately contact your supplier if you detect a potential
danger when using the product.
The user of the product is always fully responsible
for observing the local safety instructions and
regulations. Observe all applicable safety
instructions and regulations.
User manual
- Everyone working on or with the product, must be familiar
with the contents of this manual and must strictly observe
the instructions therein. The management should instruct the
personnel in accordance with the manual and observe all
instructions and directions given.
- Do not change the order of the steps to perform.
- Keep the manual with the product.
Users
- The use of this product is exclusively reserved to authorised,
personnel in training can only use the product under
supervision and responsibility of skilled engineers.
- Stay alert and keep your attention to your work. Do not use
alcohol or medicine.
- The product is not to be used by children or persons with
reduced physical, sensory or mental capabilities, or lack of
experience and knowledge, unless they have been given
supervision or instruction.
- Children must be supervised not to play with the product.

0000110292/010123/B MiniMan-100 | MiniMan-100 ATEX | MiniMan-100 TopGrade 4
Intended use2
The product has been designed exclusively for extracting
soldering fumes, airborne dust, fumes from solvents, TIG
welding and MIG-MAG/GMAW welding. The TopGrade type of
arm (fully white) is especially suitable for use in laboratories in
the pharmaceutical, chemical and food processing industry.
Using the product for other purposes is considered contrary to
its intended use. The manufacturer accepts no liability for any
damage or injury resulting from such use. The product has
been built in accordance with state-of-the-art standards and
recognised safety regulations. Only use this product when in
technically perfect condition in accordance with its intended
use and the instructions explained in the user manual.
Technical specications
Modications
Product combinations
If the product is used in combination with other products or
machines, the safety instructions in the documentation of
these products also apply.
Installation
- The installation of this product is exclusively reserved to
- During installation, always use Personal Protective
Equipment (PPE) to avoid injury. This also applies to persons
who enter the work area during installation.
-
on a higher level than 2 metres (local restrictions may
apply).
- Do not install the product in front of entrances and exits
which must be used for emergency services.
- Mind any gas and water pipes and electric cables.
- Make sure that the workspace is well illuminated.
- Stay alert and keep your attention to your work. Do not
drugs, alcohol or medicine.
- Air containing particles such as chromium, nickel, beryllium,
cadmium, lead etc., should never be recycled. This air must
always be brought outside the working area.
Use
WARNING!
Fire hazard! Do not use the product for:
- polishing applications in combination with
grinding, welding or any other application that
generate sparks
exposed to sparks)
- arc-air gouging
-
or solids or liquids
- extracting of aggressive fumes (such as
hydrochloric acid) or sharp particles
- extracting dust particles which are released when
welding surfaces treated with primer
- sucking cigarettes, cigars, oiled tissues, and other
burning particles, objects, and acids
2. “Intended use” as explained in EN-ISO 12100-1 is the use for which the
directions in the sales brochure. In case of doubt it is the use which can be
deduced from the construction, the model and the function of the technical
product which is considered normal use. Operating the machine within the
limits of its intended use also involves observing the instructions in the user
manual.
WARNING!
Explosion hazard! Do not use the product for
explosion-hazardous applications, e.g.:
- aluminium laser cutting
- grinding aluminium and magnesium
- explosive environments or explosive substances/
gases
This warning does not apply to MiniMan-100 ATEX
arms
WARNING!
Do not use the product for:
- extraction of hot gases (more than 70°C/158°F
continuously)
-
- oil mist
- heavy oil mist in welding fume
- extraction of cement, saw dust, wood dust etc.
• Inspect the product and check it for damage. Verify the
functioning of the safety features.
• During use, always use Personal Protective Equipment
(PPE) to avoid injury. This also applies for persons who
enter the work area.
• Check the working environment. Do not allow unauthorised
persons to enter the working environment.
• Protect the product against water and humidity.
•
• Make sure that the workshop, in the vicinity of the product,
Service, maintenance and repairs
• Obey the maintenance intervals given in this manual.
Overdue maintenance can lead to high costs for repair and
revisions and can render the guarantee null and void.
• Always use Personal Protective Equipment (PPE) to avoid
injury. This also applies for persons who enter the work
area.
•
• Use tools, materials, lubricants and service techniques
which have been approved by the manufacturer. Never use
worn tools and do not leave any tools in or on the product.
• Safety features which have been removed for service,
maintenance or repairs, must be put back immediately
still function properly.
•
working on a higher level than 2 metres (local restrictions
may apply).
• Clean the area afterwards.
ATTENTION
Service, maintenance and repairs must be
performed in accordance with directive TRGS 560
persons (skilled) using appropriate work practices.
Personal protective equipment (PPE)
Wear respiratory protection and protective
gloves during service, maintenance and
repairs.

0000110292/010123/B MiniMan-100 | MiniMan-100 ATEX | MiniMan-100 TopGrade 5
4 INSTALLATION
4.1 Tools and requirements
You need the following tools and requirements to
install the product:
- basic tools
4.2 To be sourced locally
You need the following material to install the
product:
- wall mounting hardware3
4.3 Unpacking
Make sure that the product is complete. The
package contains:
- extraction arm, incl. mounting bracket (fully
assembled)
If parts are missing or damaged, contact your supplier.
4.4 Installation height
You can install the MiniMan arm at any desired height. For
mounting examples, refer to page 10;
- Fig. III: “H” types
- Fig. IV: “S” types
4.5 Mounting
PA | Stanchion
To install the MiniMan-100 on a stanchion, refer to
the instruction sheet that is supplied with the PA.
Refer to the available product data sheet for
mounting examples.
The package contains no mounting hardware for the mounting
bracket, since the required mounting hardware depends on the
wall type.
WARNING!
Before you install the product, make sure that the
wall or mounting structure is strong enough. Refer
to § 1.5 for the weight of the product.
4.5.1 Mounting bracket
Fig. 4.2
• Determine the desired installation height.
• Install the mounting bracket (including the arm) to the wall
or mounting structure.
3. The type of hardware depends on the wall type
B
A
D
D
E
C
B
A
D
D
E
C
MiniMan-75 MiniMan-100
mm in.
A162
B202 8
C186
D30
E79
Fig. 4.2 Mounting bracket
4.6 MiniMan-100 ATEX
The MiniMan-100 ATEX arm is factory-wise provided with litz
wires between the metal parts, including the spring steel wires
of the hoses. To make the arm suitable for use in potentially
explosive atmospheres, you must make an earth connection.
Fig. 4.5
• Connect the litz wire (A) to the extraction hood with the
faston connector.
Fig. 4.3
A
Connection of the litz wire to the hood
Fig. 4.4
• Connect the other litz wire (A) to the extraction duct with a
self-tapping screw4.
• Make sure that the rotation of the arm is not obstructed by
the litz wire.
4. Size 4,2 mm

0000110292/010123/B MiniMan-100 | MiniMan-100 ATEX | MiniMan-100 TopGrade 6
Fig. 4.4
A
A
Connection of the litz wire to the duct
Fig. 4.5
• Measure the earth connection between the hood and the
duct. The electrical resistance must be lower than 10 ohm.
ATTENTION!
If the electrical resistance is over 10 ohm, the litz
wire connection is not correct. In that case: make
sure that all litz wires from the hood to the duct are
interconnected.
Fig. 4.5
< 10 ohm
< 10 ohm
Earth connection
5 USE
Personal protective equipment (PPE)
During use, use PPE to avoid injury. This
also applies for persons who enter the work
area.
Fig. 5.1
• Take the handle (ref. Fig. 2.1 I) of the hood to position it at
max. 300 mm (12 in.) above the source of pollution.
•
open.
• Turn on the connected extraction fan or system.
• Start working.
•
• When the working position changes, move the nozzle to
the correct position in relation to the workpiece.
•
A
C
B
A
C
B
A
C
B
A = max. 300 mm
(12 in.)
B = >300 mm
(12 in.)
C = >0 mm
(0 in.)
Fig. 5.1 A = Correct position of the hood (example: soldering)
6 MAINTENANCE
6.1 Periodic maintenance
The product has been designed to function without
problems for a long time with a minimum of
maintenance. In order to guarantee this some simple, regular
maintenance and cleaning activities are required which are
described in this chapter. If you observe the necessary caution
and carry out the maintenance at regular intervals, any
problems occurring will be detected and corrected before they
lead to a total breakdown.
WARNING!
The indicated maintenance intervals can vary depending on
recommend to thoroughly inspect the complete product once
every year beside the indicated periodic maintenance. For this
purpose contact your supplier.
Component Action Frequency:
every X
months
X=3 X=6
Outside of
the arm
Clean with a non-aggressive
detergent
X
Flexible hoses Check for cracks or damages. Replace
if necessary
X
Inside of the
arm
Clean thoroughly X
Arm
movement
Check the movement of the arm. If
necessary, adjust the friction; refer to
§ 6.2
X
6.2 Arm adjustment
If the extraction arm, or a part of it, does not stay in the
desired position, you must adjust the friction.
Fig. 6.1
• Determine which part of the arm needs more or less
friction;
- inner tube (ref. Fig. 2.1E): adjust friction joint A
- outer tube (ref. Fig. 2.1F): adjust friction joint B
- hood (ref. Fig. 2.1G): adjust joint C

0000110292/010123/B MiniMan-100 | MiniMan-100 ATEX | MiniMan-100 TopGrade 7
AB
AB
C
C
MiniMan H
AB
AB
C
C
MiniMan S
Fig. 6.1 Adjustment points
7 TROUBLESHOOTING
If the product does not function (correctly), consult
the checklist below to see if you can remedy the
error yourself. Should this not be possible, contact
your supplier.
WARNING!
Obey the safety regulations that are written in
chapter 3 when you carry out the activities below.
Symptom Problem Possible
cause
Solution
The extraction
arm does not stay
in the desired
position
Escape of
fume or
dust; no
proper
extraction
Friction
setting is not
correct
Adjust the friction;
refer to § 6.2
You cannot get
the arm in the
desired position
Escape of fume or
extraction
No proper
extraction
Loose hose(s) Fasten the hose(s)
properly
Hose damage Replace the hose(s)
8 SPARE PARTS
The following spare parts are available for the
product;
- refer to exploded view Fig. V on page 11
9 DISPOSAL
After life of the product, dispose of it in accordance
with federal, state or local regulations.
CE DECLARATION
CE declaration of conformity for machinery
We, Plymovent Manufacturing B.V., Koraalstraat 9,
1812 RK Alkmaar, Netherlands, herewith declare, on
our own responsibility, that the products:
- MiniMan-100-1.5/H ATEX
- MiniMan-100-2.1/H ATEX
which this declaration refers to, have been manufactured in
compliance with the directions of the Directive Council of 17th
of May 2006 regarding machine safety 2006/42/EC, amended
by the directive 95/16/EC with special reference to appendix I
regarding basic health and safety requirements in connection
with the construction and manufacturing of machinery.
Applicable standards:
- EN-ISO 12100:2010 | Safety of machinery
Basic concepts, general principles for design
- EN-IEC 60079-11:2012
Explosive atmospheres – Part 11: Equipment protection by
intrinsic safety “i”
- ISO/IEC 80079-36
Explosive atmospheres – Part 36: Non-electrical equipment
for use in explosive atmospheres
The products are approved for zone 1 (Gas) and zone 21
(Dust), in accordance with the ATEX Directive 2014/34/EU.
- Product group: II
- Product category: 2
Marking:
- Ex II 2G
- Ex II 2D
Signature:
Name: M.S.J. Ligthart
Position: Product Manager
Date of issue: 1st January 2023

0000110292/010123/B MiniMan-100 | MiniMan-100 ATEX | MiniMan-100 TopGrade 8
ANNEX
Fig. I Working reach
956
879
575.5
240.6
MM-100-1.5/H MM-100-1.5/S
MM-100-2.1/H MM-100-2.1/S
MM-160-2.0/H
MM-160-3.0/H
1000 mm
(3¼ ft.)
1000 mm
(3¼ ft.)
2000 mm
(6½ ft.)
2200 mm
(7¼ ft.)
2600 mm
(8½ ft.)
2000 mm
(6½ ft.)
A
B
A
B
956
879
575.5
240.6
MM-100-1.5/H MM-100-1.5/S
MM-100-2.1/H MM-100-2.1/S
MM-160-2.0/H
MM-160-3.0/H
1000 mm
(3¼ ft.)
1000 mm
(3¼ ft.)
2000 mm
(6½ ft.)
2200 mm
(7¼ ft.)
2600 mm
(8½ ft.)
2000 mm
(6½ ft.)
A
B
A
B
MM-100-1.5 MM-100-2.1
mm ft. mm ft.
A1618 5½
B2116 7

0000110292/010123/B MiniMan-100 | MiniMan-100 ATEX | MiniMan-100 TopGrade 9
ANNEX
Fig. II Pressure drop
0
100
200
300
400
500
600
700
800
900
1000
1100
100 200 300 400 500 600
m³/h
Pa
500
0
100 150 200 250 300 350 400
700
CFM
1
0
2
3
4
in. WG
m³/h

0000110292/010123/B MiniMan-100 | MiniMan-100 ATEX | MiniMan-100 TopGrade 10
ANNEX
Fig. III Mounting examples MiniMan H
956
879
575.5
240.6
MM-100-1.5/H MM-100-1.5/S
MM-100-2.1/H MM-100-2.1/S
MM-160-2.0/H
MM-160-3.0/H
1000 mm
(3¼ ft.)
1000 mm
(3¼ ft.)
2000 mm
(6½ ft.)
2200 mm
(7¼ ft.)
2600 mm
(8½ ft.)
2000 mm
(6½ ft.)
A
B
A
B
956
879
575.5
240.6
MM-100-1.5/H MM-100-1.5/S
MM-100-2.1/H MM-100-2.1/S
MM-160-2.0/H
MM-160-3.0/H
1000 mm
(3¼ ft.)
1000 mm
(3¼ ft.)
2000 mm
(6½ ft.)
2200 mm
(7¼ ft.)
2600 mm
(8½ ft.)
2000 mm
(6½ ft.)
A
B
A
B
MM-100-1.5/H MM-100-2.1/H
1000 mm
(3½ ft.)
MM-100-1.5/S
MM-100-1.5/H
MM-100-1.5/H + PA-220/160
Fig. IV Mounting examples MiniMan S
956
879
575.5
240.6
MM-100-1.5/H MM-100-1.5/S
MM-100-2.1/H MM-100-2.1/S
MM-160-2.0/H
MM-160-3.0/H
1000 mm
(3¼ ft.)
1000 mm
(3¼ ft.)
2000 mm
(6½ ft.)
2200 mm
(7¼ ft.)
2600 mm
(8½ ft.)
2000 mm
(6½ ft.)
A
B
A
B
956
879
575.5
240.6
MM-100-1.5/H MM-100-1.5/S
MM-100-2.1/H MM-100-2.1/S
MM-160-2.0/H
MM-160-3.0/H
1000 mm
(3¼ ft.)
1000 mm
(3¼ ft.)
2000 mm
(6½ ft.)
2200 mm
(7¼ ft.)
2600 mm
(8½ ft.)
2000 mm
(6½ ft.)
A
B
A
B
MM-100-1.5/S MM-100-2.1/S
1000 mm
(3½ ft.)
MM-100-1.5/S
MM-100-1.5/H
MM-100-1.5/H + PA-110/160

0000110292/010123/B MiniMan-100 | MiniMan-100 ATEX | MiniMan-100 TopGrade 11
ANNEX
Fig. V Exploded view
MiniMan 100-1.5/H
MiniMan 100-2.1/H
(+ ATEX)
MiniMan 100-1.5/S
MiniMan 100-2.1/S
0000101132
0000102503
0000102504
0000102503
0000102504
0000101994
0000101995
0000102007
(3/3)
0000102000
0000102001
0000102000
0000102001
0000101994
0000101995
0000101996
0000101997
0000102007
(1/3)
0000102002
0000102003
0000102509
0000102511
0000102513
0000102515
0000102509
0000102511
0000102513
0000102515
0000102517
0000102519
0000102521
0000102523
0000102517
0000102519
0000102521
0000102523
0000101998
0000101999
0000101996
0000101997
0000102007
(2/3)
0000101996
0000101997
0000101996
0000101997
0000101132
0000102506
0000102507
0000102506
0000102507
0000102506
0000102507
0000102506
0000102507

0000110292/010123/B MiniMan-100 | MiniMan-100 ATEX | MiniMan-100 TopGrade 12
ANNEX
Article no. Description
General
0000101132 DAMPER-100
• MM-100-1.5/H 0000101109
0000101994 Hose L=330 mm/Ø 100 mm (black), incl. 2 tie-wraps
0000101996 Hose L=500 mm/Ø 100 mm (black), incl. 2 tie-wraps
0000102000 Hood MM-100 (black), complete
0000102002 Balancing strap MM-100-1.5/H
0000102503 Wall mounting bracket MM-100 (black)
0000102506 Joint MM-100 (black)
0000102509 Inner tube MM-100-1.5 yellow
0000102517 Outer tube MM-100-1.5 yellow
• MM-100-1.5/H TopGrade 0000101117
0000101995 Hose L=330 mm/Ø 100 mm (white), incl. 2 tie-wraps
0000101997 Hose L=500 mm/Ø 100 mm (white), incl. 2 tie-wraps
0000102001 Hood MM-100 (white), complete
0000102002 Balancing strap MM-100-1.5/H
0000102504 Wall mounting bracket MM-100 (white)
0000102507 Joint MM-100 (white)
0000102511 Inner tube MM-100-1.5 white
0000102519 Outer tube MM-100-1.5 white
• MM-100-1.5/H ATEX 0000101128
0000102000 Hood MM-100 (black), complete
0000102002 Balancing strap MM-100-1.5/H
0000102503 Wall mounting bracket MM-100 (black)
0000102506 Joint MM-100 (black)
0000102007 Hose set Ø 100 mm (antistatic), incl. 6 hose clamps
0000102509 Inner tube MM-100-1.5 yellow
0000102517 Outer tube MM-100-1.5 yellow
• MM-100-2.1/H 0000101110
0000101994 Hose L=330 mm/Ø 100 mm (black), incl. 2 tie-wraps
0000101996 Hose L=500 mm/Ø 100 mm (black), incl. 2 tie-wraps
0000102000 Hood MM-100 (black), complete
0000102003 Balancing strap MM-100-2.1/H
0000102503 Wall mounting bracket MM-100 (black)
0000102506 Joint MM-100 (black)
0000102513 Inner tube MM-100-2.1 yellow
0000102521 Outer tube MM-100-2.1 yellow
• MM-100-2.1/H TopGrade 0000101118
0000101995 Hose L=330 mm/Ø 100 mm (white), incl. 2 tie-wraps
0000101997 Hose L=500 mm/Ø 100 mm (white), incl. 2 tie-wraps
0000102001 Hood MM-100 (white), complete
0000102003 Balancing strap MM-100-2.1/H
0000102504 Wall mounting bracket MM-100 (white)
0000102507 Joint MM-100 (white)
0000102515 Inner tube MM-100-2.1 white
0000102523 Outer tube MM-100-2.1 white
• MM-100-2.1/H ATEX 0000101129
0000102000 Hood MM-100 (black), complete
0000102003 Balancing strap MM-100-2.1/H
0000102503 Wall mounting bracket MM-100 (black)
0000102506 Joint MM-100 (black)
0000102007 Hose set Ø 100 mm (antistatic), incl. 6 hose clamps
0000102513 Inner tube MM-100-2.1 yellow
0000102521 Outer tube MM-100-2.1 yellow
Article no. Description
• MM-100-1.5/S 0000114588
0000101994 Hose L=330 mm/Ø 100 mm (black), incl. 2 tie-wraps
0000101996 Hose L=500 mm/Ø 100 mm (black), incl. 2 tie-wraps
0000101998 Gas spring 300 N
0000102000 Hood MM-100 (black), complete
0000102503 Wall mounting bracket MM-100 (black)
0000102506 Joint MM-100 (black)
0000102509 Inner tube MM-100-1.5 yellow
0000102517 Outer tube MM-100-1.5 yellow
• MM-100-2.1/S 0000114587
0000101994 Hose L=330 mm/Ø 100 mm (black), incl. 2 tie-wraps
0000101996 Hose L=500 mm/Ø 100 mm (black), incl. 2 tie-wraps
0000101999 Gas spring 500 N
0000102000 Hood MM-100 (black), complete
0000102503 Wall mounting bracket MM-100 (black)
0000102506 Joint MM-100 (black)
0000102513 Inner tube MM-100-2.1 yellow
0000102521 Outer tube MM-100-2.1 yellow

www.plymovent.com
0000110292/010123/B MiniMan-100 | MiniMan-100 ATEX | MiniMan-100 TopGrade
Other manuals for Miniman-100
1
This manual suits for next models
2
Table of contents
Other Plymovent Robotics manuals