Safety Instructions
Please take a few moments to carefully read through this
manual. Correct maintenance and operation of this machine will
provide the best possible performance from your POLAR product.
• Position on a flat, stable surface.
• A service agent/qualified technician should carry out
installation and any repairs if required. Do not remove any
components or service panels on this product.
• Consult Local and National Standards to comply with the
following:
- Health and Safety at Work Legislation
- BS EN Codes of Practice
- Fire Precautions
- IEE Wiring Regulations
- Building Regulations
• DO NOT use jet/pressure washers to clean the appliance.
• DO NOT use the appliance outside.
• DO NOT use this appliance to store medical supplies.
• DO NOT stand or support yourself on the base, drawers or
doors.
• DO NOT allow oil or fat to come into contact with the plastic
components or door seal. Clean immediately if contact occurs.
• Bottles that contain a high percentage of alcohol must be
sealed and placed vertically in the refrigerator.
• Always carry, store and handle the appliance in a vertical
position and move by holding the base of the appliance.
• Always switch off and disconnect the power supply to the unit
before cleaning.
• Keep all packaging away from children. Dispose of the
packaging in accordance with the regulations of local
authorities.
• Children should be supervised to ensure that they do not play
with the appliance.
GD882-GD883_UA009_ML_A5_v6_20211217.indb 2GD882-GD883_UA009_ML_A5_v6_20211217.indb 2 2021/12/17 14:462021/12/17 14:46

3
UK
• This appliance is not intended for use by persons (including
children) with reduced physical, sensory or mental capabilities,
or lack of experience or knowledge, unless they have been
given supervision or instruction concerning the use of the
appliance by a person responsible for their safety.
• POLAR recommend that this appliance should be periodically
tested (at least annually) by a Competent Person. Testing
should include, but not be limited to: Visual Inspection,
Polarity Test, Earth Continuity, Insulation Continuity and
Functional Testing.
• POLAR recommend that this product is connected to a circuit
protected by an appropriate RCD (Residual Current Device).
Caution Risk of Fire
• Do not store explosive substances such as aerosol cans
with a flammable propellant in this appliance.
Warning: Keep all ventilation openings clear of
obstruction. Unit should not be boxed in without
adequate ventilation.
• Warning: Do not use mechanical devices or other means
to accelerate the defrosting process, other than those
recommended by the manufacturer.
• Warning: Do not damage the refrigerant circuit.
• Warning: Do not use electrical appliances inside the food
storage compartments of the appliance, unless they are the
type recommended by the manufacturer.
Product Description
GD882 - POLAR Stainless Steel Preparation Counter - Double Doors
GD883 - POLAR Stainless Steel Preparation Counter - Double Doors
UA009 - POLAR Stainless Steel Preparation Counter - Single Door
Pack Contents
The following is included:
• POLAR Refrigerator • Instruction Manua
• Gastronorm spacer bars
GD882-GD883_UA009_ML_A5_v6_20211217.indb 3GD882-GD883_UA009_ML_A5_v6_20211217.indb 3 2021/12/17 14:462021/12/17 14:46

4
UK
POLAR prides itself on quality and service, ensuring
that at the time of packaging the contents are
supplied fully functional and free of damage.
Should you find any damage as a result of transit,
please contact your POLAR dealer immediately.
Installation
Note: If the unit has not been stored or
moved in an upright position, let it stand
upright for approximately 12 hours before
operation. If in doubt allow to stand.
1. Remove the appliance from the packaging.
Make sure that all protective plastic film and
coatings are thoroughly removed from all
surfaces.
2. To optimize performance and longevity, ensure
a minimum clearance of 2.5cm is maintained
between the unit and walls and other objects,
with a minimum 5cm clearance on the top.
NEVER LOCATE NEXT TO A HEAT SOURCE.
Note: Before using the appliance for the
first time, clean the shelves and interior
with soapy water.
3. Set the brakes on the castors to keep the
appliance in position.
Operation
Turn On
1. Close the door(s) of the appliance.
2. Ensure the power switch is set to [O] and turn
on at the socket.
3. Switch on the Power [I]. The current
temperature within the appliance is displayed.
Control Panel
Set the Operating Temperature
1. Hold the SET button for 3 seconds. The value
of the current set point will be displayed.
2. Press the or buttons to display the
required temperature.
3. Press the SET button to store the temperature.
Manual Defrost
Press and hold the defrost button "aux" for
2 seconds to begin a manual defrost. The defrost
light illuminates.
Cleaning, Care &
Maintenance
Switch off and disconnect
from the power supply before
cleaning.
• Clean the interior of the appliance as often as
possible.
• Do not use abrasive cleaning agents. These
can leave harmful residues.
• Clean the door seal with warm soapy water.
• Always wipe dry after cleaning.
• Do not allow water used in cleaning to run
through the drain hole into the evaporation
pan.
• Take care when cleaning the rear of the
appliance. Sharp edges can cut.
Condensation will form in refrigeration with
frequent opening of the doors and on hot
humid days, please ensure condensation is
allowed to drain properly or is wiped dry.
Cleaning the Condenser
• Periodically cleaning the condenser can extend
the life of the appliance.
• POLAR recommend that a POLAR agent or
qualified technician clean the condenser.
GD882-GD883_UA009_ML_A5_v6_20211217.indb 4GD882-GD883_UA009_ML_A5_v6_20211217.indb 4 2021/12/17 14:462021/12/17 14:46

5
UK
Troubleshooting
If your POLAR appliance develops a fault, please check the following table before making a call to the
Helpline or your POLAR dealer. A POLAR agent or qualified technician must carry out repairs if required.
Fault Probable Cause Solution
The appliance is not
working
The unit is not switched on Check the unit is plugged in correctly and
switched on
Plug or lead is damaged Replace plug or lead
Fuse in the plug has blown Replace the fuse
Mains power supply fault Check mains power supply
The appliance turns on,
but the temperature is
too high/low
Too much ice on the evaporator Defrost the appliance
Condenser blocked with dust Call POLAR agent or qualified Technician
Doors are not shut properly Check doors are shut and seals are not
damaged
Appliance is located near a
heat source or air flow to the
condenser is being interrupted
Move the refrigerator to a more suitable
location
Ambient temperature is too high Increase ventilation or move appliance to a
cooler position
Unsuitable foodstuffs are being
stored in the appliance
Remove any excessive hot foodstuffs or
blockages to the fan
Appliance is overloaded Reduce the amount of food stored in the
appliance
The appliance is
leaking water
The appliance is not properly
levelled
Adjust the screw feet to level the appliance
(if applicable)
The discharge outlet is blocked Clear the discharge outlet
Movement of water to the drain is
obstructed
Clear the floor of the appliance (if
applicable)
The drip tray is overflowing Empty the drip tray (if applicable)
The appliance is
unusually loud
Loose nut/screw Check and tighten all nuts and screws
The appliance has not been
installed in a level or stable
position
Check installation position and change if
necessary
Technical Specifications
Model Voltage Power Current Temperature
Range Refrigerant Dimensions
H x W x D mm Weight
(kg)
GD882 230V
50Hz
400W 3.0A 2°C - 8°C R290 110g 1097 x 1225 x
760
138
GD883 400W 3.0A 2°C - 8°C R290 120g 1097 x 1555 x
760
159
UA009 280W 3.0A 2°C - 8°C R290 70g 1097 X 735 X
760
95
GD882-GD883_UA009_ML_A5_v6_20211217.indb 5GD882-GD883_UA009_ML_A5_v6_20211217.indb 5 2021/12/17 14:462021/12/17 14:46