Potter LED-16F User manual

LED-16 Series
LED Annunciator
8830096 - Rev D • 12/18 PAGE 1 OF 2
Potter Electric Signal Company, LLC • St. Louis, MO • Phone: 800-325-3936 • www.pottersignal.com
LED-16 Flush Mount LED-16 Surface Mount
Description
The LED-16 Series is a LED remote annunciator for various Potter
addressable re control panels. The LED-16 Series communicates
using a RS-485 (P-Link) connection to the main panel providing zone
specic indication of Alarm, Supervisory, Trouble conditions.
The LED-16 Series features 2 slide-in labels allowing each of the 16
zones to be customized for any application. It can be ush mounted
or surface mounted. It can be mounted on a single gang electrical box
or a four-square electrical box. The annunciator utilizes a sheet metal
enclosure secured with a Potter lock.
Technical Specications
Standby Current 20 mA
Alarm Current 25 mA
Operating Temperature 0°C-49°C (32°F-120°F)
Operating Humidity Range 0 to 93% (non-condensing)
Maximum Wire Length 6500 ft.
Maximum Annunciators 31
Flush Mount Size
(WxHxD) 11 3/8” x 9-1/4” x 7/8”
Surface Mount Size
(WxHxD) 11 3/8” x 9-1/4” x 3 1/8”
Wire Gauge 12 AWG-22 AWG
Compatible Panels
IPA Series
AFC/ARC Series
PFC-4064
P-Series*
PFC-6000 Addressable Series*
*Legacy Product
Features
• Capable of displaying alarms, supervisory, trouble status for 16
zones
• System Silence and Reset buttons
• Common LEDs for status indication
• Maximum 31 LED-16s for:
PFC-6800, P400(R), IPA-4000, and AFC-1000.
• Maximum 10 LED-16s for:
PFC-6030/6075(R)/6200, P100/200/300, IPA-60, IPA-100, AFC-
50, AFC/ARC-100 and PFC-4064
• Maximum P-Link wire length of 6,500 feet
• Available in four colors
• Product includes a 5 year warranty
• UUKL Listed for Smoke Control
NOTE: LED PWR can be provided by any re listed source. Output
power must be 16 VDC–33 VDC and must be power limited.
7305-0328:0200 UOXX.S2930
firealarmresources.com
8830096 - Rev D • 12/18 PAGE 2 OF 2
Potter Electric Signal Company, LLC • St. Louis, MO • Phone: 800-325-3936 • www.pottersignal.com
LED-16 Series
LED Annunciator
LED PWR
P-Link
- +
- + A B
P-Link from control panel
Example:
Powered by control panel
Power from
auxiliary supply
LED PWR
P-Link
- +
- + A B
P-Link from
control panel
Example:
Powered by auliliary supply
The LED-16 Series is connected to the re alarm control panel using a four wire RS-485 connection. The connection is power limited and supervised.
Up to 31 LED-16 Series LED annunciators can be connected on PFC series, Potter Plus Series, AFC and IPA series panels.
Installation
Wiring Diagrams
Fig 1
Fig 2
Model Description Stock No.
LED-16F LED Annunciator Flush
Mount 3992727
LED-16 LED Annunciator Surface
Mount 3992666
Ordering Information
Zone labels
may be
inserted
here
Wiring LED-16 Series to Control Panel or Auxiliary Power Example
LED-16 Series Module Showing Front Cover and Board
firealarmresources.com

This manual suits for next models

2

Other Potter Security System manuals

Potter Amseco SSX-81 User manual

Potter

Potter Amseco SSX-81 User manual

Potter MHT-1224 Series User manual

Potter

Potter MHT-1224 Series User manual

Potter PFC-4410G3 User manual

Potter

Potter PFC-4410G3 User manual

Potter DCM-4 User manual

Potter

Potter DCM-4 User manual

Potter RA-6075R User manual

Potter

Potter RA-6075R User manual

Potter LED-4410G3 User manual

Potter

Potter LED-4410G3 User manual

Potter PDC Series User manual

Potter

Potter PDC Series User manual

Potter VSA User manual

Potter

Potter VSA User manual

Potter LED-16 Series User manual

Potter

Potter LED-16 Series User manual

Popular Security System manuals by other brands

G2 UPS-100 quick start guide

G2

G2 UPS-100 quick start guide

SVAT CV501 - 16CH instruction manual

SVAT

SVAT CV501 - 16CH instruction manual

ADEMCO 1025 installation instructions

ADEMCO

ADEMCO 1025 installation instructions

Swann PRO-640 Specifications

Swann

Swann PRO-640 Specifications

Telefire ADR-3000 System introduction

Telefire

Telefire ADR-3000 System introduction

Aurora TAVIS TAV-BX1 quick start

Aurora

Aurora TAVIS TAV-BX1 quick start

GE Concord 4 installation manual

GE

GE Concord 4 installation manual

Eaton Activeline GH5 Technical manual

Eaton

Eaton Activeline GH5 Technical manual

Ezviz T9 quick start guide

Ezviz

Ezviz T9 quick start guide

Swann Fourtify quick start guide

Swann

Swann Fourtify quick start guide

MobileHelp Fall Button user guide

MobileHelp

MobileHelp Fall Button user guide

Bosch FMC-210-SM installation manual

Bosch

Bosch FMC-210-SM installation manual

Moore Industries SPA manual

Moore Industries

Moore Industries SPA manual

Iteris VersiCam user guide

Iteris

Iteris VersiCam user guide

Profort multiGuard DIN9 3G quick guide

Profort

Profort multiGuard DIN9 3G quick guide

GSD GSD-i70 installation manual

GSD

GSD GSD-i70 installation manual

Kimessa CANline 02 user manual

Kimessa

Kimessa CANline 02 user manual

Knox KEYSECURE 6 Quick start installation guide

Knox

Knox KEYSECURE 6 Quick start installation guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.