PPS SuperNOVA Guide

Precision Pumping Systems •GoPPS.com •6515 Business Way, Boise, ID 83716 •208.323.5300
PUMP SYSTEMS
Installation, Operations & Maintenance Instructions
0 - Warranty Information
1 - Safety Instructions
2 - Component Manual Library
3 - Flagship Pump Station Components
4 - Drop Pipe Installation
5 - Custom Pump Station Components
6 - Theory of Operation
7 - Basic Operation
8 - Control & Monitoring
9 - Troubleshooting
10 - Maintenance & Winterization
11 - Start-Up & Winterization Checklist

Precision Pumping Systems •GoPPS.com •6515 Business Way, Boise, ID 83716 •208.323.5300
TABLE of CONTENTS
2
Warranty Information
1-Year Warranty
3-Year Warranty
Safety Instructions
Component Manuals Library
Flagship Pump Station Components
ARIEL
ATLAS
SuperNOVA
NEBULA
NEUTRON
NOVA
ORION
PHOENIX
VEGA
Drop Pipe Installation
Custom Pump Station Components
Canned Turbine Pump Station
End Suction Centrifugal Booster
Submersible Pump Station
Vertical Multi-Stage Booster
Vertical Turbine-Submersible
Theory of Operation
Single-Pump Systems
Multi-Pump Systems
Start-Up
Basic Operation
Control & Monitoring
PPS Controls
Non-PPS Controls
Troubleshooting
Maintenance & Winterization
Start-Up & Winterization Checklist
0
0.1
0.2
1
3
2
4
5
6
5.1
3.1
3.4
3.7
5.2
5.4
3.2
3.5
3.8
5.3
5.5
6.1
6.2
6.3
3.3
3.6
3.9
7
8
8.1
8.2
9
10
11
.....................................................pg.3
..............................................................pg.3
..............................................................pg.4
...........................................................pg.5
.......................................pg.7
.......................pg.8
..................................................................................pg.9
..............................................................................pg.11
..................................................................pg.13
..........................................................................pg.15
......................................................................pg.17
...............................................................................pg.19
.............................................................................pg.21
........................................................................pg.23
...............................................................................pg.25
..................................................pg.30
......................pg.31
.............................pg.31
.........................pg.33
....................................pg.35
.................................pg.37
...............................pg.39
.....................................................pg.41
..............................................pg.41
................................................pg.41
..........................................................................pg.42
..............................................................pg.43
...................................................pg.44
.................................................................pg.46
..................................................pg.53
.........................................................pg.54
............................pg.58
................pg.61

Precision Pumping Systems •GoPPS.com •6515 Business Way, Boise, ID 83716 •208.323.5300
Standard 1-Year Warranty
3
Theequipmentfurnishedaspartofthisagreementissubjecttotheoriginalmanufacturer’swarrantyonly.Inaddition,PrecisionPumping
Systems(PPS)providesthefollowingLIMITEDWARRANTY:Telephone technical support free-of-charge for the life of your product.
Limited 1-Year Warranty
PPSwarrantstotheoriginalbuyerthatitsproductsandsystemswillbefreefromdefectsinmaterialandworkmanshipforaperiodof
twelve(12)monthsfromthedateofplacingtheEquipmentinoperationorfteen(15)monthsfromthedateofcompletionofmanufacture
oftheEquipment,whichevershalloccurrst.WhennotiedbyPurchaserofadefectwhichconformstothisWarrantyPPSshall,atitssole
discretion,correctthedefectbyperformingasuitablerepairtotheEquipmentorbyprovidingareplacementpart.Thiswarrantydoesnot
applytoequipmentthathasbeendamaged,misappliedormodiedinanyway.
Terms and Conditions:
1. WarrantyclaimsmustbesubmitteddirectlytoPrecisionPumpingSystemwithinthevalidwarrantyperiod.
NoclaimsforwarrantywillbepaidwithoutpriorapprovalbyPPS.
2. ThedeterminationregardingdefectivestatusofcomponentsorproductsisatthesolediscretionofPPS.
3. IfacomponentorproductisdeterminedtobedefectivebyPrecisionPumpingSystem,thenPPSshall,atitssolediscretion,correctthe
defectbyperformingasuitablerepairtotheequipmentorbyprovidingareplacementpart.
4. Properstart-upandoperationalproceduresmustbefollowed,andtherequiredannualpreventativemaintenancemustbeperformed
byauthorizedPPSpersonnelorthiswarrantyshallbevoid.
5. Withintherstyearafterstart-up,PPSwillcoverlaborandmaterialscosts.Inanysubsequentyearsofthewarrantyperiod(ifan
extendedwarrantyispurchased)onlymaterialscostsarecoveredbythiswarranty–nolaborcostswillbepaid.
Disclaimers
1. PPSshallnotbeliableforrepairs,replacementsoradjustmentstotheEquipmentorcostsoflaborperformedbythePurchaserwithout
priorwrittenconsentofPPS.
2. AllPPSwarrantyprovisionsrequirethePurchasertooperateandmaintaintheEquipmentaccordingtogoodindustrypracticesandto
complywithallrecommendationsbyPPSregardingoperationandmaintenance.
3. PPSsystemsareequippedwithsafetyfeatureswhichprotectkeycomponentsfromdamage.Manyofthesesafetyfeaturesare
overriddenwhenoperatingthesystemin“Hand”.Operationofthesystemin“Hand”voidsthiswarrantyunlessdirectlyauthorizedbya
PPStechnician.
4. Thereisnowarrantycoverageformechanicalpumpsealsorpackingglandsunlessthefailureoccursduringtheinitialstart-upof
thesystem.
5. AnymodicationstothepumpingsystemwithoutwrittenapprovalbyPPSshallvoidthiswarranty.Suchmodicationsinclude,
butarenotlimitedto,changestoPLC/HMIprogramming,removingordisablingsensors,oraddingorremovingvalvesorpiping.
6. PPSmakesnoperformancewarrantyunlessspecicallystatedinitsproposal.
7. Theeectsofcorrosion,erosionandnormalwearandteararespecicallyexcludedfromthePPSwarranty.
8. PPSprovidesnowarrantyforusedorexistingcustomerownedequipmentofanycharacterexpressedorimplied.
9. Blownfusesregardlessofcauseareexcluded.Damagesorproblemscreatedbyorcausedbylightningorpowersurges,lowvoltage,
orotherincomingpowerrelatedproblemsareexcludedfromthesewarranties.
10. Damagescreatedbyorresultingfromexcessivelydirtywater,mud,silt,sand,grass,weeds,oranyotherorganicorinorganicmaterials,
cloggedpumpintakeimpellersorsuctionscreens,and/orbuild-upofsedimentinthesumpareexcluded.
11. Naturaldisasters,misuse,abuse,ormisapplication,orothercausesbeyondPPS’control,andactsofGodareexcludedfromthese
warranties.
12. PPSwillnotacceptanyresponsibilityforthecostsassociatedwithsystemsinstalledindiculttoaccessareasincluding,butnot
limitedto,thoserequiringcranesinexcessof5tons,divers,helicopters,excavators,dredges,etc.Determinationofdiculttoaccess
locationsisatthesolediscretionofPPS.
13. PPSMAKESNOOTHERWARRANTYORREPRESENTATIONOFANYKINDWHATSOEVER,EXPRESSEDORIMPLIED,EXCEPTTHATOFTITLE,
ANDALLIMPLIEDWARRANTIES,INCLUDINGANYWARRANTYOFMERCHANTABLITYANDFITNESSFORAPARTICULARPURPOSE,ARE
SPECIFICALLYEXCLUDED.
14. PPSwillassumenoliabilityforanyincidentalorconsequentialdamageswithrespecttothiscontractortheEquipmentandservices
furnishedhereunder,inconnectionwiththeperformanceorbreachthereof,orfromthemanufacture,sale,delivery,installation,repair
ortechnicaldirectioncoveredbyorfurnishedunderthiscontract.Thisisacommercialtransaction.
15. Itisalsoagreedthattheowner’sorpurchaser’ssoleremedy,whetherforbreachofcontract,warrantyorintort,shallbelimitedtothe
returnofanygoodsandrepaymentofthecontractpriceorthecostsofrepairandreplacementofdefectivegoods,attheoptionofPPS.
Noclaimbythebuyerofanykindshallbegreaterinamountthanthenetpurchasepriceoftheequipment.
Choice of law and arbitration:Anyclaimorcontroversyarisingunderorrelatingtothiswarrantyshallbesubmittedforarbitrationand
shallbegovernedbythelawsofthestateofIdaho.

Precision Pumping Systems •GoPPS.com •6515 Business Way, Boise, ID 83716 •208.323.5300
Irrigation Industry 3-Year Warranty
4
Theequipmentfurnishedaspartofthisagreementissubjecttotheoriginalmanufacturer’swarrantyonly.Inaddition,PrecisionPumping
Systems(PPS)providesthefollowingLIMITEDWARRANTY:Telephone technical support free-of-charge for the life of your product.
Limited 3-Year Warranty
PPSwarrantsthatitsproductsandsystemswillbefreefromdefectsinmaterialandworkmanshipforaperiodofthree(3)yearsfromthe
dateofplacingtheequipmentinoperationorforty(40)monthsfromthedateofcompletionofmanufactureoftheequipment,whichever
shalloccurrst.Initialstart-upandpreventativemaintenancemustbeperformedbyanauthorizedPPSrepresentativeorthewarrantyshall
bevoid.Thiswarrantydoesnotapplytoequipmentthathasbeendamaged,misappliedormodiedinanyway.
Terms and Conditions:
1. WarrantyclaimsmustbesubmitteddirectlytoPrecisionPumpingSystemwithinthevalidwarrantyperiod.
NoclaimsforwarrantywillbepaidwithoutpriorapprovalbyPPS.
2. ThedeterminationregardingdefectivestatusofcomponentsorproductsisatthesolediscretionofPPS.
3. IfacomponentorproductisdeterminedtobedefectivebyPrecisionPumpingSystem,thenPPSshall,atitssolediscretion,correctthe
defectbyperformingasuitablerepairtotheequipmentorbyprovidingareplacementpart.
4. Properstart-upandoperationalproceduresmustbefollowed,andtherequiredannualpreventativemaintenancemustbeperformed
byauthorizedPPSpersonnelorthiswarrantyshallbevoid.
5. Withintherstyearafterstart-up,PPSwillcoverlaborandmaterialscosts.Inthesecondandthirdyearsofthewarrantyperiodonly
materialscostsarecoveredbythiswarranty–nolaborcostswillbepaid.
Disclaimers
1. PPSshallnotbeliableforrepairs,replacementsoradjustmentstotheEquipmentorcostsoflaborperformedbythePurchaserwithout
priorwrittenconsentofPPS.
2. AllPPSwarrantyprovisionsrequirethePurchasertooperateandmaintaintheEquipmentaccordingtogoodindustrypracticesandto
complywithallrecommendationsbyPPSregardingoperationandmaintenance.
3. PPSsystemsareequippedwithsafetyfeatureswhichprotectkeycomponentsfromdamage.Manyofthesesafetyfeaturesare
overriddenwhenoperatingthesystemin“Hand”.Operationofthesystemin“Hand”voidsthiswarrantyunlessdirectlyauthorizedbya
PPStechnician.
4. Thereisnowarrantycoverageformechanicalpumpsealsorpackingglandsunlessthefailureoccursduringtheinitialstart-upof
thesystem.
5. AnymodicationstothepumpingsystemwithoutwrittenapprovalbyPPSshallvoidthiswarranty.Suchmodicationsinclude,butare
notlimitedto,changestoPLC/HMIprogramming,removingordisablingsensors,oraddingorremovingvalvesorpiping.
6. PPSmakesnoperformancewarrantyunlessspecicallystatedinitsproposal.
7. Theeectsofcorrosion,erosionandnormalwearandteararespecicallyexcludedfromthePPSwarranty.
8. PPSprovidesnowarrantyforusedorexistingcustomerownedequipmentofanycharacterexpressedorimplied.
9. Blownfusesregardlessofcauseareexcluded.Damagesorproblemscreatedbyorcausedbylightningorpowersurges,lowvoltage,or
otherincomingpowerrelatedproblemsareexcludedfromthesewarranties.
10. Damagescreatedbyorresultingfromexcessivelydirtywater,mud,silt,sand,grass,weeds,oranyotherorganicorinorganicmaterials,
cloggedpumpintakeimpellersorsuctionscreens,and/orbuild-upofsedimentinthesumpareexcluded.
11. Naturaldisasters,misuse,abuse,ormisapplication,orothercausesbeyondPPS’control,andactsofGodareexcludedfrom
thesewarranties.
12. PPSwillnotacceptanyresponsibilityforthecostsassociatedwithsystemsinstalledindiculttoaccessareasincluding,butnotlimited
to,thoserequiringcranesinexcessof5tons,divers,helicopters,excavators,dredges,etc.Determinationofdiculttoaccesslocations
isatthesolediscretionofPPS.
13. PPSMAKESNOOTHERWARRANTYORREPRESENTATIONOFANYKINDWHATSOEVER,EXPRESSEDORIMPLIED,EXCEPTTHATOFTITLE,
ANDALLIMPLIEDWARRANTIES,INCLUDINGANYWARRANTYOFMERCHANTABLITYANDFITNESSFORAPARTICULARPURPOSE,ARE
SPECIFICALLYEXCLUDED.
14. PPSwillassumenoliabilityforanyincidentalorconsequentialdamageswithrespecttothiscontractortheEquipmentandservices
furnishedhereunder,inconnectionwiththeperformanceorbreachthereof,orfromthemanufacture,sale,delivery,installation,repair
ortechnicaldirectioncoveredbyorfurnishedunderthiscontract.Thisisacommercialtransaction.
15. Itisalsoagreedthattheowner’sorpurchaser’ssoleremedy,whetherforbreachofcontract,warrantyorintort,shallbelimitedtothe
returnofanygoodsandrepaymentofthecontractpriceorthecostsofrepairandreplacementofdefectivegoods,attheoptionofPPS.
Noclaimbythebuyerofanykindshallbegreaterinamountthanthenetpurchasepriceoftheequipment.
Choice of law and arbitration:Anyclaimorcontroversyarisingunderorrelatingtothiswarrantyshallbesubmittedforarbitrationand
shallbegovernedbythelawsofthestateofIdaho.

Precision Pumping Systems •GoPPS.com •6515 Business Way, Boise, ID 83716 •208.323.5300
SAFETY INSTRUCTIONS
5
1.1 Electrical Hazards
To help prevent severe injury or property damage, please carefully read through each of the following warnings:
IMPORTANT
IMPORTANT
CAUTION
CAUTION
!
!
!
!
!
!
!
!
WARNING DANGER
DANGER
DANGER
HAZARDOUS VOLTAGE
Hazardous voltage inside this panel will cause
an electrical shock or an arc ash explosion,
which may result in SEVERE INJURY or DEATH.
ELECTRIC SHOCK HAZARD
ARC FLASH HAZARD
ELECTRIC SHOCK HAZARD
ARC FLASH EXPLOSION
ELECTRIC SHOCK HAZARD
ARC FLASH EXPLOSION
SAFE WORK PRACTICES
Follow all NFPA 70E requirements for safe work practices
and for personal protective equipment.
Main Disconnect and branch circuit protection for this
panel to be provided by others.
TURN OFF ALL power to the control panel before
working on or around electrical equipment.
Never operate or start the equipment with the control
panel open, otherwise an ARC EXPLOSION may occur.
RISK OF ELECTRIC SHOCK
More than one disconnect switch may be required
to de-energize the equipment before servicing.
AUTHORIZED VFD TECHNICIAN ONLY
This station uses a variable frequency drive (VFD).
VFD servicing or troubleshooting to be performed
by an authorized VFD Technician ONLY.
DISCONNECT POWER BEFORE SERVICING
WARNING!
Working on a pressurized system can cause an
explosion resulting in SEVERE INJURY OR DEATH.
RELIEVE SYSTEM PRESSURE before working
on the pump station or attached equipment.
HAZARDOUS PRESSURE
RISK OF EXPLOSION AND SEVERE INJURY
IF EQUIPMENT FAILS
1.2 Pressure Hazards

WARNING
! !
DO NOT PUMP HAZARDOUS FLUIDS
This system is not designed for pumping hazardous uids.
Pumping hazardous uids can cause re, burns, or death.
1.3 Pumped Fluid Hazards
1.4 Equipment Protection
Precision Pumping Systems •GoPPS.com •6515 Business Way, Boise, ID 83716 •208.323.5300
SAFETY INSTRUCTIONS
6
To help prevent severe injury or property damage, please carefully read through each of the following warnings:
IMPORTANT
IMPORTANT
!
!
RISK OF FREEZING DAMAGE
RISK OF AUTOMATIC FILTER DAMAGE
Freezing conditions may cause the piping, ttings and
sensing components to crack or malfunction, which
may create an explosion resulting in
SEVERE INJURY OR PROPERTY DAMAGE.
NOTE: The manufacturer is not responsible for any
damages caused by freezing due to improper
winterizations. Read and follow the winterization
procedures in this manual.
DO NOT allow downstream pressurized water to ow
backwards into the lter unit under any circumstances.
The downstream check valve has been modied at the
factory to allow some water to return into the
collector tank for sensing purposes.
If the downstream mainline needs to be drained,
an external drain plug mounted downstream of
the lter unit must be provided. The system MUST
have at least 35 PSI of pressure for the lter unit
to operate and clean eectively.
The lter ush valve drain MUST be sized correctly.
Run it to a dump pit or downstream in a ditch.

COMPONENT MANUAL LIBRARY
FLOW METERS & FLOW SWITCHES HARMONIC FILTERS
PRESSURE TRANSMITTER & SENSORS AIR CONDITIONERS
PLCs & HMIs INTERNET CONNECTIVITY
TEMPERATURE MONITORING CHEMICAL CONTROLLERS & FEEDERS
VOLTAGE MONITORING DEHUMIDIFIERS
POWER MANAGEMENT HEATERS
PUMPS AUTO DIALERS
PRESSURE GAUGES MOTORS
VALVES CHLORINE ANALYZERS
VFDs FILTERS
FollowthisQRCodeorclickHERE. FollowthisQRCodeorclickHERE.
FollowthisQRCodeorclickHERE. FollowthisQRCodeorclickHERE.
FollowthisQRCodeorclickHERE. FollowthisQRCodeorclickHERE.
FollowthisQRCodeorclickHERE. FollowthisQRCodeorclickHERE.
FollowthisQRCodeorclickHERE. FollowthisQRCodeorclickHERE.
FollowthisQRCodeorclickHERE. FollowthisQRCodeorclickHERE.
FollowthisQRCodeorclickHERE. FollowthisQRCodeorclickHERE.
FollowthisQRCodeorclickHERE. FollowthisQRCodeorclickHERE.
FollowthisQRCodeorclickHERE. FollowthisQRCodeorclickHERE.
FollowthisQRCodeorclickHERE. FollowthisQRCodeorclickHERE.
Can’tndthecomponentmanualyouneed?ContactourServiceSupportTeamat(208) 287-9361orviaemailat[email protected]forassistance.

ARIEL Series
Precision Pumping Systems •GoPPS.com •6515 Business Way, Boise, ID 83716 •208.323.5300 8
FLAGSHIP PUMP STATION COMPONENTS
3.1
*Yourstationmaydierslightlyfromthis
image.Ifyouneedassistancelocatinga
componentnotshown,contactourService
SupportTeamat(208) 287-9361
orviaemailat[email protected].”

ARIEL Component Manuals
PLC & HMI
VFD
PUMP
MOTOR
PRESSURE
GAUGE
PRESSURE
TRANSMITTER
FLOW METER
YourpumpstationincludesaphysicalordigitalPLCandHMI.Locate
thebrandandmodelnumberinyourpumpstationandlocatethe
correctmanualbyfollowingthisQRCodeorclickingHERE.
Yourpumpstationincludesavariablefrequencydrive.Locatethe
brandandmodelnumberinyourpumpstationandlocatethecorrect
manualbyfollowingthisQRCodeorclickingHERE.
Yourpumpstationincludesanend-suctioncentrifugalpump.Locate
thebrandandmodelnumberinyourpumpstationandlocatethe
correctmanualbyfollowingthisQRCodeorclickingHERE.
Yourpumpstationincludesamotor.Locatethebrandandmodel
numberinyourpumpstationandlocatethecorrectmanualby
followingthisQRCodeorclickingHERE.
Yourpumpstationincludesapressuregauge.Locatethebrandand
modelnumberinyourpumpstationandlocatethecorrectmanualby
followingthisQRCodeorclickingHERE.
Yourpumpstationincludesapressuretransmitter.Locatethebrand
andmodelnumberinyourpumpstationandlocatethecorrect
manualbyfollowingthisQRCodeorclickingHERE.
Yourpumpstationmayincludeaowmeter.Locatethebrandand
modelnumberinyourpumpstationandlocatethecorrectmanualby
followingthisQRCodeorclickingHERE.
Precision Pumping Systems •GoPPS.com •6515 Business Way, Boise, ID 83716 •208.323.5300 9
FILTER
Yourpumpstationincludesalter.Locatethebrandandmodel
numberinyourpumpstationandlocatethecorrectmanualby
followingthisQRCodeorclickingHERE.
Can’tndthecomponentmanualyouneed?ContactourServiceSupportTeamat(208) 287-9361orviaemailat[email protected]forassistance.

ATLAS Series
Flow meter
(optional)
Suction
Bypass
Pressure Transducer
Pressure Tank
Run Dry Protection
Outlet
Thermosetting epoxy
powder coating provides
corrosion protection
(custom colors available)
Air Relief Valve
Precision Pumping Systems •GoPPS.com •6515 Business Way, Boise, ID 83716 •208.323.5300 10
3.2
*Yourstationmaydierslightlyfromthis
image.Ifyouneedassistancelocatinga
componentnotshown,contactourService
SupportTeamat(208) 287-9361
orviaemailat[email protected].”

ATLAS Component Manuals
PLC & HMI
Yourpumpstationmayincludeaowmeter.Locatethebrandand
modelnumberinyourpumpstationandlocatethecorrectmanualby
followingthisQRCodeorclickingHERE.
Precision Pumping Systems •GoPPS.com •6515 Business Way, Boise, ID 83716 •208.323.5300 11
YourpumpstationincludesaphysicalordigitalPLCandHMI.Locate
thebrandandmodelnumberinyourpumpstationandlocatethe
correctmanualbyfollowingthisQRCodeorclickingHERE.
VFD
Yourpumpstationincludesavariablefrequencydrive.Locatethe
brandandmodelnumberinyourpumpstationandlocatethecorrect
manualbyfollowingthisQRCodeorclickingHERE.
PUMP
Yourpumpstationincludesanend-suctioncentrifugalpump.Locate
thebrandandmodelnumberinyourpumpstationandlocatethe
correctmanualbyfollowingthisQRCodeorclickingHERE.
MOTOR
Yourpumpstationincludesamotor.Locatethebrandandmodel
numberinyourpumpstationandlocatethecorrectmanualby
followingthisQRCodeorclickingHERE.
PRESSURE
GAUGE
PRESSURE
TRANSMITTER
FLOW METER
Yourpumpstationincludesapressuregauge.Locatethebrandand
modelnumberinyourpumpstationandlocatethecorrectmanualby
followingthisQRCodeorclickingHERE.
Yourpumpstationincludesapressuretransmitter.Locatethebrand
andmodelnumberinyourpumpstationandlocatethecorrect
manualbyfollowingthisQRCodeorclickingHERE.
Can’tndthecomponentmanualyouneed?ContactourServiceSupportTeamat(208) 287-9361orviaemailat[email protected]forassistance.

SuperNOVA Series
Precision Pumping Systems •GoPPS.com •6515 Business Way, Boise, ID 83716 •208.323.5300 12
Lockable Marine
Grade Aluminum
Enclosure
Exhaust Fan
Pressure
Gauge
Flow
Switch
Pressure Sensor
2” MPT
Connection
(Suction and
Discharge)
1” Blow Out
Pressure Tank
Exhaust Fan
VFD
Vent
Touch Display
Combo Pressure Gauge
VFD Access
Cover
Vent/Drain
Isolation
Valve
3.3 *Yourstationmaydierslightlyfromthis
image.Ifyouneedassistancelocatinga
componentnotshown,contactourService
SupportTeamat(208) 287-9361
orviaemailat[email protected].”

SuperNOVA Component Manuals
PLC & HMI
Yourpumpstationmayincludeaowmeter.Locatethebrandand
modelnumberinyourpumpstationandlocatethecorrectmanualby
followingthisQRCodeorclickingHERE.
Precision Pumping Systems •GoPPS.com •6515 Business Way, Boise, ID 83716 •208.323.5300 13
YourpumpstationincludesaphysicalordigitalPLCandHMI.Locate
thebrandandmodelnumberinyourpumpstationandlocatethe
correctmanualbyfollowingthisQRCodeorclickingHERE.
VFD
Yourpumpstationincludesavariablefrequencydrive.Locatethe
brandandmodelnumberinyourpumpstationandlocatethecorrect
manualbyfollowingthisQRCodeorclickingHERE.
PUMP
Yourpumpstationincludesanend-suctioncentrifugalpump.Locate
thebrandandmodelnumberinyourpumpstationandlocatethe
correctmanualbyfollowingthisQRCodeorclickingHERE.
MOTOR
Yourpumpstationincludesamotor.Locatethebrandandmodel
numberinyourpumpstationandlocatethecorrectmanualby
followingthisQRCodeorclickingHERE.
PRESSURE
GAUGE
PRESSURE
TRANSMITTER
FLOW METER
Yourpumpstationincludesapressuregauge.Locatethebrandand
modelnumberinyourpumpstationandlocatethecorrectmanualby
followingthisQRCodeorclickingHERE.
Yourpumpstationincludesapressuretransmitter.Locatethebrand
andmodelnumberinyourpumpstationandlocatethecorrect
manualbyfollowingthisQRCodeorclickingHERE.
Can’tndthecomponentmanualyouneed?ContactourServiceSupportTeamat(208) 287-9361orviaemailat[email protected]forassistance.

NEBULA Series
Precision Pumping Systems •GoPPS.com •6515 Business Way, Boise, ID 83716 •208.323.5300 14
Motor
Service Rated External Disconnect
Single point of connection
for incoming power
Variable Frequency Drive (VFD)
Controls the speed of the motor to maintain
constant output pressure and varying ows
Pump
Flow Switch
Protects the pump from
running dry and helps the
pump go into idle mode
Check
Valve
Advanced
Keyboard
for easy control
and operation
Pressure Gauge
Pressure Transmitter
Sends pressure
reading to the VFD
3.4 *Yourstationmaydierslightlyfromthis
image.Ifyouneedassistancelocatinga
componentnotshown,contactourService
SupportTeamat(208) 287-9361
orviaemailat[email protected].”

NEBULA Component Manuals
PLC & HMI
Yourpumpstationmayincludeaowmeter.Locatethebrandand
modelnumberinyourpumpstationandlocatethecorrectmanualby
followingthisQRCodeorclickingHERE.
Precision Pumping Systems •GoPPS.com •6515 Business Way, Boise, ID 83716 •208.323.5300 15
YourpumpstationincludesaphysicalordigitalPLCandHMI.Locate
thebrandandmodelnumberinyourpumpstationandlocatethe
correctmanualbyfollowingthisQRCodeorclickingHERE.
VFD
Yourpumpstationincludesavariablefrequencydrive.Locatethe
brandandmodelnumberinyourpumpstationandlocatethecorrect
manualbyfollowingthisQRCodeorclickingHERE.
PUMP
Yourpumpstationincludesanend-suctioncentrifugalpump.Locate
thebrandandmodelnumberinyourpumpstationandlocatethe
correctmanualbyfollowingthisQRCodeorclickingHERE.
MOTOR
Yourpumpstationincludesamotor.Locatethebrandandmodel
numberinyourpumpstationandlocatethecorrectmanualby
followingthisQRCodeorclickingHERE.
PRESSURE
GAUGE
PRESSURE
TRANSMITTER
FLOW METER
Yourpumpstationincludesapressuregauge.Locatethebrandand
modelnumberinyourpumpstationandlocatethecorrectmanualby
followingthisQRCodeorclickingHERE.
Yourpumpstationincludesapressuretransmitter.Locatethebrand
andmodelnumberinyourpumpstationandlocatethecorrect
manualbyfollowingthisQRCodeorclickingHERE.
Can’tndthecomponentmanualyouneed?ContactourServiceSupportTeamat(208) 287-9361orviaemailat[email protected]forassistance.

NEUTRON Series
Precision Pumping Systems •GoPPS.com •6515 Business Way, Boise, ID 83716 •208.323.5300 16
Flow Switch
Protects the pump from
running dry and helps the
pump go into idle mode
Control Box
Pressure
Gauge
Pump and Motor
VFD
Pressure Transmitter
Sends pressure
reading to the VFD
3.5
*Yourstationmaydierslightlyfromthis
image.Ifyouneedassistancelocatinga
componentnotshown,contactourService
SupportTeamat(208) 287-9361
orviaemailat[email protected].”

NEUTRON Component Manuals
PLC & HMI
Yourpumpstationmayincludeaowmeter.Locatethebrandand
modelnumberinyourpumpstationandlocatethecorrectmanualby
followingthisQRCodeorclickingHERE.
Precision Pumping Systems •GoPPS.com •6515 Business Way, Boise, ID 83716 •208.323.5300 17
YourpumpstationincludesaphysicalordigitalPLCandHMI.Locate
thebrandandmodelnumberinyourpumpstationandlocatethe
correctmanualbyfollowingthisQRCodeorclickingHERE.
VFD
Yourpumpstationincludesavariablefrequencydrive.Locatethe
brandandmodelnumberinyourpumpstationandlocatethecorrect
manualbyfollowingthisQRCodeorclickingHERE.
PUMP
Yourpumpstationincludesanend-suctioncentrifugalpump.Locate
thebrandandmodelnumberinyourpumpstationandlocatethe
correctmanualbyfollowingthisQRCodeorclickingHERE.
MOTOR
Yourpumpstationincludesamotor.Locatethebrandandmodel
numberinyourpumpstationandlocatethecorrectmanualby
followingthisQRCodeorclickingHERE.
PRESSURE
GAUGE
PRESSURE
TRANSMITTER
FLOW METER
Yourpumpstationincludesapressuregauge.Locatethebrandand
modelnumberinyourpumpstationandlocatethecorrectmanualby
followingthisQRCodeorclickingHERE.
Yourpumpstationincludesapressuretransmitter.Locatethebrand
andmodelnumberinyourpumpstationandlocatethecorrect
manualbyfollowingthisQRCodeorclickingHERE.
Can’tndthecomponentmanualyouneed?ContactourServiceSupportTeamat(208) 287-9361orviaemailat[email protected]forassistance.

NOVA Series
Automatic pump
by-pass
(optional)
Low Ambient Temperature/
Insulation and Heating
(optional)
Cooling Fan
Lockable Clam-Shell Lid
provides complete access to all
system components
Suction & discharge
drop pipes
(cut to customer
length/easy
connection to
pump station)
(optional)
Flow meter
(optional)
Free of welding
seams or cracks
to prevent rust.
Structural steel
is welded
underneath
to maximize
strength.
UL rated control cabinet for VFD
Thermosetting Epoxy
Powder Coating
provides corrosion protection
(custom colors available)
Precision Pumping Systems •GoPPS.com •6515 Business Way, Boise, ID 83716 •208.323.5300 18
3.6
*Yourstationmaydierslightlyfromthis
image.Ifyouneedassistancelocatinga
componentnotshown,contactourService
SupportTeamat(208) 287-9361
orviaemailat[email protected].”

NOVA Component Manuals
Precision Pumping Systems •GoPPS.com •6515 Business Way, Boise, ID 83716 •208.323.5300 19
PLC & HMI
Yourpumpstationmayincludeaowmeter.Locatethebrandand
modelnumberinyourpumpstationandlocatethecorrectmanualby
followingthisQRCodeorclickingHERE.
YourpumpstationincludesaphysicalordigitalPLCandHMI.Locate
thebrandandmodelnumberinyourpumpstationandlocatethe
correctmanualbyfollowingthisQRCodeorclickingHERE.
VFD
Yourpumpstationincludesavariablefrequencydrive.Locatethe
brandandmodelnumberinyourpumpstationandlocatethecorrect
manualbyfollowingthisQRCodeorclickingHERE.
PUMP
Yourpumpstationincludesanend-suctioncentrifugalpump.Locate
thebrandandmodelnumberinyourpumpstationandlocatethe
correctmanualbyfollowingthisQRCodeorclickingHERE.
MOTOR
Yourpumpstationincludesamotor.Locatethebrandandmodel
numberinyourpumpstationandlocatethecorrectmanualby
followingthisQRCodeorclickingHERE.
PRESSURE
GAUGE
PRESSURE
TRANSMITTER
FLOW METER
Yourpumpstationincludesapressuregauge.Locatethebrandand
modelnumberinyourpumpstationandlocatethecorrectmanualby
followingthisQRCodeorclickingHERE.
Yourpumpstationincludesapressuretransmitter.Locatethebrand
andmodelnumberinyourpumpstationandlocatethecorrect
manualbyfollowingthisQRCodeorclickingHERE.
Can’tndthecomponentmanualyouneed?ContactourServiceSupportTeamat(208) 287-9361orviaemailat[email protected]forassistance.

ORION Series
Precision Pumping Systems •GoPPS.com •6515 Business Way, Boise, ID 83716 •208.323.5300 20
Jockey Pump
Optional Filter
Pressure Relief
Valve
Pressure Transmitter
- High PSI Switch
Duty Pumps
Flow Meter
3.7
*Yourstationmaydierslightlyfromthis
image.Ifyouneedassistancelocatinga
componentnotshown,contactourService
SupportTeamat(208) 287-9361
orviaemailat[email protected].”
Table of contents
Other PPS Water Pump manuals
Popular Water Pump manuals by other brands

Oase
Oase Atlantis 30 Directions for use

ProMinent
ProMinent Beta b BT4b Series operating instructions

Stuart Turner
Stuart Turner FLOMATE MBF 12 Installation & maintenance instructions

Pentair
Pentair Fairbanks Nijhuis Series Installation, operation and maintenance manual

Grundfos
Grundfos Conlift1 LS Installation and operating instructions

Clarke
Clarke PW2 Operation & maintenance instructions