UNPACKING THE UNIT
Each unit is shipped with the germicidal lamp placed in a
box with protective packaging. When handling the lamp
take care to not touch the glass portion of the lamp with
bare hands. ils from
the hands can cause “hot spots” which
reduce lamp life. Handle by the socket end or use a soft cloth.
If you accidentally
touch a lamp, clean it using the included
alcohol cleaning pad or a soft cloth damp-ened with
rubbing alcohol. The lamp is fragile and proper care must
be taken when removing from packaging.
The following parts are included:
• Power Supply with remote lamp assembly
• ne (1) Germicidal Twin H Lamp (packed in lamp box)
• Eight (8) Sheet Metal Screws
•Two (2) caution labels
• Installation & maintenance instructions
•
Strain relief connector
•
Alcohol cleaning pad
When installing and using this electrical equip ent, basic safety precautions should always be followed including the following:
1. READ AND FOLLOW ALL INSTRUCTIONS.
2.
Always be sure the unit is unplugged during installation or service procedures.
3.
The ultraviolet light produced by the UV la p is har ful to your eyes. Do not look directly at
the la p. Should it beco e necessary to view the la p, use UV-protected sunglasses.
Lors de l’installation et de l’utilisation de cet équipe ent, des précautions devront être suivies.
1- Lire et suivre es étapes attentivement.
2- Assurez vous de toujours débrancher avant l installation ou le service.
3- Ne pas regarder la la pe directe ent avec les yeux. Si nécessaire de le faire,
veuillez porter les lunettes de soleil contre les rayons U.V.
IMPORTANT: SAFETY INSTRUCTIONS
IMPORTANT: Inst uctions de secu ité

INSTALLATION:
• Do not locate the unit within 20” of plastic material that will be directly exposed to the UV light,
such as wiring, return-side humidifier or certain types of air filters. Check with the filter manufacturer
to see if their material is UV resistant. ver time, UV light may degrade plastic.
• Do not touch the glass portion of the lamps with bare hands because oils from the hands can cause
“hot spots” which reduce lamp life. Handle either by the porcelain caps or use a soft cloth. If you
accidentally touch a lamp, wipe it off, using a soft cloth dampened with rubbing alcohol.
INSTALLING THE GERMICIDAL UNIT
1. Using the lamp mount as a template, draw the hole pattern on the air duct in a suitable location.
2. Using a 1 1/4 inch Vari Bit, make two holes side by side. Clean off excess metal between the
two holes with tin snips.
3. Peel off the adhesive backing of the gasket on backside of mounting plate.
4. Center mounting plate on hole.
5. Use four self tapping screws provided to secure mounting plate on the air duct.
6. Find a suitable location to mount the ballast making sure supply cord to ballast will reach 120 to 240
volt power supply. Mount the ballast using four self-tapping sheet metal screws provided.
7.
Unplug mid cord connector by pressing the lock release (marked “PRESS” on the connector.)
Route the cord to the lamp mount area. (See Photo B)
8. Taking care not to touch the glass, hold the lamp by the plastic end and insert fully into the base plate.
9. Insert the water resistant lamp socket over the plastic lamp end fitting over the mountng studs,
secure using the two thumb nuts and reconnect the mid cord connector. (Photo A & B)
10. Adhere included UV Warning La el onto ductwork within six inches of each UV lamp..
WIRING/FUSE
The multivoltage ballast is self-adjusting and operates with voltages from 120 - 240 VAC. For 120V wiring
install a 5 amp inline fuse to L1. Connect the black wire to L1, white wire to neutral, green wire to ground. Be
sure power cord is secured with the included strain relief connector.
For hard wiring to 240V systems install
5 amp inline fuses to both legs of power. Then connect the black wire to L1, white wire to L2, green
wire to ground.
Be sure power cord is secured with the strain relief connector.
It is not necessary to cycle the germicidal air purifier with the furnace blower. You may allow unit to run
continuously or have it
interlocked with the furnace blower. If a 120 VAC EAC terminal is available, supply
power to the unit from the EAC terminal. Connect in accordance with local wiring codes. If there is no EAC
terminal, interlock the UV unit with the furnace blower using an appropriate alternate.
Wire the unit in
accordance
with local wiring codes. After installing, verify voltage is operating between 120 - 240 VAC
with air handler operating.
ACCESSORIES
Magnetic Z bracket for Germicidal Lamp Part #500483-MG
Duct-mount plate for Germicidal Lamp Part #DMP-Remote

MAINTENANCE
This maintenance schedule is only a guideline, determined by average conditions. Actual conditions
will dictate the frequency of cleaning and/or replacement of lamps. Do not touch the glass portion of the
lamp with bare hands because oils from the hands can cause “hot spots” which reduce lamp life.
Handle either by the socket end or use a soft cloth. If you accidentally touch a lamp, clean it using a
soft cloth dampened with rubbing alcohol.
CLEANING THE LAMP - Recommended interval: 12 months
1. Disconnect power to the unit. Unplug mid cord connector before removing lamp.
2.
Remove two thumb nuts from lamp mount then holding the lamp socket pull away from lamp mount.
3.
Using a soft cloth moistened with rubbing alcohol, wipe down the lamp. If there is a large build-up
of dust particles, you may wish to use a can of air first. Always handle lamp by the end socket.
4.
Carefully slide lamp into duct through lamp mount reinstalling thumb nuts until is fits securely.
5. Reconnect mid cor connector and restore power to the unit.
REPLACING THE LAMP - Recommended interval: 24 months
Replacement lamps are available through your HVAC contractor.
Follow above procedure except #4 where you replace the lamp instead of cleaning it. (Note: standard
off-the-shelf lamps are not compatible with this unit. Use of improper lamps will void warranty.)
TROUBLESHOOTING
•
With the selector switch in the N position, the LED should light when power is supplied to the unit.
If the LED does not light with switch in the On position:
1. Check to be sure there is power to the unit.
2. Be sure lamp connectors are fastened securely.
3. If the LED still does not light, replace lamp(s).
4. If still not operating, replace ballast.
Note: Standard off-the-shelf lamps are not compatible with this unit. Use of improper lamps will void warranty.
WARRANTY
All electronic
components carry a lifetime
warranty to the original homeowner. In addition there is a four
year warranty
from the date of installation for any subsequent owner. The manufacturer reserves the right to
send replacement parts or to replace the unit at its discretion. This warranty does not cover any labor or
damage resulting from improper installation or abuse. Use of any lamp other than a genuine Premier ne
lamp designed for this device will void the warranty.
The original lamps are warranted for a period of two years. This warranty does not cover lamps broken during
shipping, installation or as a result of improper handling.
All returns are routed through your contractor/wholesaler and must be approved and accompanied by an RGA#.
The limited warranties described above are in lieu of any other warranty, whether expressed or implied, writ-
ten or oral (including any warranty of merchantability or fitness for a particular purpose.) This warranty
gives you specific legal rights and you may also have other rights which vary from state to state.
© 2014 For service please call 800-982-1840.

Ai flow
UVC
Unit
Alternate
mounting
position
Power Supply Di ensions:
Size (L x W x D)
6.5”L x 5”W x 1.75”D
Lamp Socket Dimensions:
Size (L x W x D)
3.5”L x 2.75”W x 1.625”D
3099107
© 2014 For service please call
800-982-1840.
1. Using the lamp mount as a template, draw the
hole pattern on the air duct in a suitable location.
2. Using a 1 1/4 inch Vari Bit, make two holes side
by side. Clean off excess metal between the two
holes with tin snips.
3. Peel off the adhesive backing of the gasket on
backside of mounting plate.
4. Center mounting plate on hole.
5. Use four self tapping screws provided to secure
mounting plate on the air duct.

Photo C
Photo B
Photo A
Table of contents
Other PremierOne Farm Equipment manuals
Popular Farm Equipment manuals by other brands

Schaffert
Schaffert Rebounder Mounting instructions

Stocks AG
Stocks AG Fan Jet Pro Plus 65 Original Operating Manual and parts list

Cumberland
Cumberland Integra Feed-Link Installation and operation manual

BROWN
BROWN BDHP-1250 Owner's/operator's manual

Molon
Molon BCS operating instructions

Vaderstad
Vaderstad Rapid Series instructions