PRG SmartXcan™ Quick Start Guide
Version as of: 20 July 2020
PRG part number: AAE-8312
Production Resource Group, L.L.C.
Dallas Oce
3110 Roy Orr Blvd Suite 200
Grand Prairie, TX 75050 USA
www.prg.com

3
©2020 Production Resource Group, L.L.C. All Rights Reserved
Specications are subject to change without notice. July2020
Introduction
Use this Quick Start Guide to quickly set up and understand the major
components of the SmartXcan Mobile Pedestal. It is critical to review these
materials to ensure proper usage of the device.
For further details, refer to the SmartXcan User Manual.
Environmental Conditions
The SmartXcan requires specic environmental conditions for accurate
temperature readings. Use in a space with controlled environmental
conditions.
+Ideal 64 - 75°F / 18 - 24°C
+Relative non-condensing humidity 10-75%
+Do not place next to a heat source
+The thermal image sensor should not be aimed at
any other temperature source such as a incandescent
light source, radiator, or A/C system
+Do not point at the sun or open sky
Acclimation (Warmup) Period
The Unit requires one minute to start up and an estimated acclimation
period of 15 minutes. This acclimation period allows the temperature
scanning instrumentation to neutralize to the environment. The SmartXcan is
set to allow temperature scans before the acclimation period is completed,
but temperature accuracy can be aected.
If the unit is moved after the initial acclimation period, the device should be
allowed to re-acclimate for at least 15 minutes before performing additional
temperature measurements.
SmartXcan Mobile Pedestal
Accessories
Power Cable (IEC C13)
Varies based on country of use
Battery, 14.8V 98Wh
See Batteries Spec on page 7.
Battery Charger, Travel Verison
See User Manual for charging
information.
Battery Compartment Key (x2)
Indicator Light
Temperature Scanner

4
©2020 Production Resource Group, L.L.C. All Rights Reserved
Specications are subject to change without notice. July2020
Temperature Scanner Unit Detail
SmartXcan Scanning Unit
LED Temperature Indicator Scale
By default, the acceptable temperature ranges are shown below in Figure 4.
The temperature ranges can be changed from the SmartXcan web interface.
The CDC states a fever to be any temperature of 100.4°F or above.
Measurement
successful.
LED ring green.
5 of 8 LEDs
light up. No
increased body
temperature.
95.0-100.3°F
35.0-37.9°C
Measurement
successful.
LED ring red.
6 of 8 LEDs
light up. Slightly
increased body
temperature.
100.4-101.0°F
38.0-38.3°C
Measurement
successful.
LED ring red.
7 of 8 LEDs
light up.
Increased body
temperature.
101.1-102.7°F
38.4-39.3°C
Measurement
successful.
LED ring green.
8 of 8 LEDs
light up.
High body
temperature.
>102.7°F
>39.3°C
LED Temperature Scale Breakdown
Securing Unit
The SmartXcan unit must be secured to ensure it will remain upright.
SmartXcan Base Mounting
Secure unit with two fasteners (Ø1/4” max). Each shall have a minimum
tensile capacity of 200 lbf.
Each fastener shall have sucient embedment depth to withstand 200 lbf of
tension.
Distance Measuring Sensor
Temperature Sensor
LED Temperature
Indicator
LED Ring

5
©2020 Production Resource Group, L.L.C. All Rights Reserved
Specications are subject to change without notice. July2020
Connecting Power
AC Power
Connect the unit to a grounded AC power source of 100-240V 50/60Hz.
Note: The battery does not charge when the SmartXcan is connected to AC power.
Battery Power
Step 1. Unlock the battery door on the rear of the unit.
Step 2. Install a charged battery onto the battery mounting plate by sliding
the battery downwards onto a charging bay. Ensure the V-Mount rails
are aligned between the charger and battery.
Step 3. The battery is fully engaged when the latch makes an audible “click”
sound and is rmly seated.
PoE
See the SmartXcan User Manual for connecting to a PoE source.
Operating Modes
Standalone
The SmartXcan device will operate as-is without any additional network
or computer connections. This is the most simple and common operating
mode.
Networked
Optionally, the user may choose to connect the device to a single computer
or a computer network to perform any of the following (but not limited to):
+Enable a simple Kiosk (monitoring) mode
+Congure the device
+For additional features, refer to the SmartXcan User Manual
Accessing SmartXcan Web Interface
Use the following steps to access the SmartXcan web interface
SmartXcan Web Interface Kiosk Window
Step 1. Set the IP address of the computer you wish to connect the
SmartXcan as stated below. Computer IP Address: 192.168.100.101
Subnet Mask: 255.255.255.0
Step 2. It is recommended to disable all other network sources of the
computer such as WiFi. Any rewalls should also be disabled.
Step 3. Open a web browser window and type in the IP address
192.168.100.223
Refer to the SmartXcan User Manual for login and conguration information.

6
©2020 Production Resource Group, L.L.C. All Rights Reserved
Specications are subject to change without notice. July2020
Temperature Scanning Procedure
Position face about 12 inches from the scanner
2
Identify the center of the temperature scanner. The
ring will illuminate green once in the measurement
zone.
3
Measurement Acceptable Measurement Not Acceptable
Observe the illumination of the indicator light and
audible sound conrming scanner completion.
4
1Approach the SmartXcan Mobile Pedestal

7
©2020 Production Resource Group, L.L.C. All Rights Reserved
Specications are subject to change without notice. July2020
Battery Specs
Shape Full Play 14.8V 98Wh Rechargeable Lithium-Ion V-Mount
Rated Battery Usage
+Scanner only: 54.3 hours
+Scanner & Indicator Light: 38.0 hours (700 scans per hour)
+Scanner & Indicator Light: 52.8 hours (average of 50 scans per hour)
+Estimated Battery Lifetime: 3.3 years (continuous use)
Transport: Safe for air travel (IATA approved) Ensure proper markings on box
according to company policy and local ordinances.
Refer to the SmartXcan User Manual for information on other compatible
batteries.
Cleaning
To clean the SmartXcan body and mobile pedestal, use a non-abrasive
disinfectant such as a 10:1 Bleach Mixture or other disinfectant wipe. Use
extra care not to soak the temperature probe.
To clean the SmartXcan probe, use electronics-safe and oil-free compressed
air. Do not stick any object into the probe. A dry or lightly-damped microber
cleaning cloth can also be used to clean the probes/lenses.
Support & Questions
Have you referred to the SmartXcan User Manual?
Information Page: prg.pub/SmartXcan
Technical Specs
+Mains : 100-240V ±10%, 50/60 Hz, 0.5A Max
+PoE : 37- 44VDC, 0.35A PoE Type 1 (See User
Manual for connection information)
+Battery ; 14.8VDC, 1.0A
+Operating Ranges: 18ºC to 24ºC, 10-75% non-condensing humidity
+IEC 60320 C14 Power-In
+Battery or PoE optional
+Two Neutrik® etherCON ports
+On/O Switch
+Infrared thermal array thermal sensor
+Laser IEC 60825-1:2014-3, Class 1 distance sensor
+Scan distance of 4-12in (10-30cm)
+Scan Time, Throughput: 0.6 second scan time (5
seconds for approach, scan, departure)
+700 temperature measurements per hour
+Mobile pedestal, turnstile access
+lack powdered coated aluminum (others upon request)
+Integrated buzzer and LED indicator
+Web Interface Conguration Software
+Room temperature sensor: Measuring range
0 to 85 °C (accuracy ± 0.5 °C)
+Air humidity sensor: Measuring range 0 to 100 % (accuracy ±3 %)
+Infrared sensor: Measuring range 0-100 °C,
repeatability ±0.3 °C, resolution 0.1 °C, emission
factor 0.98, ambient temperature 18 - 28 °C
+External connections
+REST API supporting plain text, JSON, or XML
content types via POST or GET methods
+Monitoring, notications, and alerts via SNMP and SMTP
+Integrated webserver with onboard management and conguration
+Integration with Kentix AlarmPro software
+Maximum Altitude: Normal 2000m
+Overvoltage Category: Normal II
+Pollution Degree: Normal 2
+IP30
+55.75” H x 18” W x 19.4” L (1416mm x 457mm x 492mm)
+Weight: 69lbs. (31.3kg)
+ETL/CE Certied (Pending)

8
©2020 Production Resource Group, L.L.C. All Rights Reserved
Specications are subject to change without notice. July2020
Compliance
This device complies with Part 15 of the FCC rules. Operation is subject to the following two
conditions:
1) This device may not cause harmful interference, and
2) This device must accept any interference received, including interference that may cause
undesired operation.
Conforms to:
UL STD 1573
PENDING CERTIFICATION to:
CAN/CSA STD E598-1
CAN/CSA STD E598-2-17
Important Safety Instructions
+ Read these instructions.
+ Keep these instructions.
+ Heed all warnings.
+ Follow all instructions.
+ Not to be used in any other way not specied by the manufacturer.
+ Do not use this apparatus near water.
+ Use caution when cleaning.
+ Do not install near any heat sources such as radiators, heat registers,
stoves, or other apparatus (including ampliers) that produce heat.
+ Protect the power cord from being walked on or pinched, particularly at plugs,
convenience receptacles, and the point where they exit from the apparatus.
+ Unplug this apparatus during lightning storms or when unused for long periods of time.
+ Refer all servicing to qualied service personnel. Servicing is required when
the apparatus has been damaged in any way, such as power-supply cord
or plug is damaged, input ports are damaged, liquid has been spilled or ob-
jects have fallen into the apparatus, the apparatus has been exposed to
rain or moisture, does not operate normally, or has been dropped.
+ In Europe: The building installation shall be regarded as providing pro-
tection in accordance with the rating of the wall socket outlet.
+ In Finland: Laite on liitettävä suojamaadoituskoskettimilla varustettuun pistorasiaan.
+ In Norway: Apparatet må tilkoples jordet stikkontakt.
+ In Sweden: Apparaten skall anslutas till jordat uttag.
+ No naked ame sources should be placed on the apparatus.
+ Apparatus not for use in tropical climates.
+ The apparatus shall not be exposed to dripping or splashing. No objects
lled with liquids, such as vases, shall be placed on the apparatus.
Medical Disclosure
This manual is not intended to dene any policy or procedures.
The SmartXcan is not a medical thermometer. It shall not be utilized as a substitute for an
examination by a medical professional. A medical examination is always necessary to determine
a subject’s exact temperature.
The PRG SmartXcan is NOT a product intended for use in the diagnosis of disease or other
conditions or in the cure, mitigation, treatment, or prevention of disease; the device is not
covered under section 201(h) of the FD&C Act (21 U.S.C. 321(h)).
The measurement should not be solely or primarily relied upon to diagnose or exclude a
diagnosis of COVID-19, or any other disease.
a) Elevated body temperature in the context of use should be conrmed with secondary
evaluation methods (e.g., an NCIT or clinical grade contact thermometer)
b) Public health ocials, through their experience with the device in the particular environment
of use, should determine the signicance of any fever or elevated temperature based on the skin
telethermographic temperature measurement;
c) The technology should be used to measure only one subject’s temperature at a time
d) Visible thermal patterns are only intended for locating the points from which to extract the
thermal measurement.
This temperature measuring device meets the (IEC 80601-2-59;2017) standard relating to
requirements for safety and essential performance of screening thermographs.
Electrical Safety
WARNING! For personal safety, this equipment must be properly grounded when connected to
an AC power source.
Do not, under any circumstances, cut or remove the ground prong from the power cord.
The power cord of this equipment is shall be minimum 18AWG with a grounding plug that mates
with a grounded outlet to minimize the possibility of electric shock hazard from this equipment.
The plug that mates to the outlet shall be compatible with the country standards the product
shall be used in. The connector mating to the device’s C14 inlet will be an IEC 60320 C13
connector.
Ensure the outlet that the device will be connected to is properly grounded. NEVER use a ground
lift or any other device which would not connect the device to ground.
Other manuals for SmartXcan
1
Table of contents
Popular Temperature Controllers manuals by other brands

Fike
Fike FIK-2351T Installation and maintenance instructions

Omron
Omron E5ZN-DRT Operation manual

OUMAN
OUMAN EH-80 operating instructions

AURATON
AURATON 200 RT owner's manual

La Crosse Technology
La Crosse Technology TX4 instruction manual

Bosch Thermotechnik
Bosch Thermotechnik 77356000216 quick start guide