manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. PrimeVOLT
  6. •
  7. Inverter
  8. •
  9. PrimeVOLT PV-5000W-V User manual

PrimeVOLT PV-5000W-V User manual

SINGLE PHASE GRID-TIE PV INVERTERS
PV-5000W-V
Installation & Operation Manual
〇Safety Precautions
Qualified Personnel ONLY!
Only Qualified technicians shall install or service unit(s) in
accordance with local wiring regulations.
PV Modules ONLY!
Designed for PV and solar power conversion only; do not use
for other DC sources or conversion purposes.
Hot Surface
Metallic parts of enclosure may be hot during operation.
Recycle
Do not throw this electronic device in a trash dumpster
when being disposed of. To minimize pollution of
environment, please consult your local service provider.
Danger!
High voltage inside inverter can cause electric
shock, even when inverter is not operating. Wait
for at least 41 minutes before opening the
enclosure.
41 minutes
1/2
〇Outline & Dimensions
Before beginning your journey, please read the following safety instructions
carefully.
〇Installation
■ Unpacking
Recommended Max. DC Power (W)
Max. DC (V)
Max. Current (A)
String
5500
580
9A/String, 18A in Total
2
■Wire Connections
■ AC(Grid) Wiring
Caution!
For safety purposes, place an independent circuit breaker
between inverter and grid BEFORE all connections. Make sure
inverter will be safely disconnected from the grid in all
circumstances.
It is recommended to use certified 250V/30A circuit breakers.
Note on Cable Selection
It is recommended to use solid cables to ensure steadfastness of
cables on terminal block. If stranded wires are used, apply core-
end materials enclosed in accessory kit for all sakes.
■ RS485 & RJ45 Connections
■ DC (PV) Wiring
Be Sure to SWITCH OFF PV
Direct pull-off of DC plugs can lead to sparks. Be sure to switch
off PV before hand.
2. Use either connector
a. Wieland PST40i1C (Preferred)
b. Multi-Contact MC4
3. Connect to PV, After all the associated cables and connectors have been
prepared
4. Remove sealing plugs as depicted on right
5. Plug in PV cables gently as depicted below
1. DC Input Ratings
614-37089-02
■ Choosing Proper Installation Site
Remind!
1. Using the 600Vdc/20A x 2(trackers) circuit breaker between
PV Module with PV Inverter.
2. Only non-grounding PV module is applicable, user is
suggested to consult with system installer for PV module
type selection.
3. Require PV modules that have IEC 61730 class A rating.
SpecificationItem
>30
cm
>30
cm
>20cm
1. Remove sealing plug and twist off the cable gland (M25)
2. Insert wires from rear of guidance and holes of rubber sealing (M25)
3. Connect RJ45 and RS485 wires as shown below
4. Make sure that RJ45 cable is wound two turns the gray EMI core
5. Tighten cable gland to secure cables firmly in position
■ Keeping Clearance
Avoid exposing the inverter in direct sunlight or to rain.
Mount the inverter in vertical direction; tilt or horizontal mounting should be
avoided.
Mounting Surface
Concrete
OK/NO
OK
Metal
Stone
OK
OK
PLastics / Acrylic NO
Wood NO
To retain the good cooling condition, keep each of unit over 20cm left and right,
30cm upper and down and ensure no any object is put around the units to affect
the cooling.
■ Assembling Bracket
Before fixing on wall, assemble the bracket as below.(Use M4 flat screws × 4 item
Ⓓ of accessory kit)
■ Mounting Bracket
■ Checking
1. Place the assembled bracket on where the inverter
will be installed. Make proper drill holes and mount
the assembled bracket with screws from accessory kit.
2. For safe and firm mounting, make at least 3 drill holes
in a triangular manner as demonstrated on right.
3. Use Ⓔ item to install mounting bracket on wall.
1. All supporting points are firm
2. Lock caps are tightened with screws
3. Inverter is well installed and secured on wall
Warranty Information
Warranty or liability will be void if damage caused by, but not limited to the
following:
1. Unauthorized opening of unit
2. Installation faults such as improper environment, wiring and applications
3. Working conditions beyond specified
4. Improper operation of unit
5. Violation of safety instructions in this manual
6. Damage during transportation
7. Any internal modifications
8. Replacing or installation of unauthorized software
9. Unforeseen calamity or force majeure
Contact Information
〇PV System
DC Switchboard
PV Generator
AC Switchboard
Public Grid
PV Inverter
A typical PV system contains:
1. PV Generator : Receive sunlight and generate DC power.
2. DC Switchboard : Links between PV panels and PV inverter, include of DC switch
and surge protection.
3. Inverter's DC Switch : PV Inverter with DC Switch(Optional).
4. PV Inverter : Converts DC power by PV panels to AC output power for public grid.
5. AC Switchboard : Links between PV inverter and public grid.
6. Public Grid : Provides utility for homes.
1. AC cord configured with M25 cable gland, containing waterproof rubber plug
three holes for cable diameter of 4.8 ~ 6.2mm, diameter is recommended to
3.5/5.5/8mm2 of wire. The following factors should be taken into account when
it comes to actual wiring: Ambient temperature, Wiring nearby, Cooling
2. Recommend to use right M25 cable gland for Line(L), neutral(N)/ground(PE)
wires
3. Twist off the cable gland and remove rubber waterproof plug. Remove the
required number of sealing plug for AC wires
4. Use the cable with appropriated wire diameter through the rubber waterproof
plug. Then insert the rubber waterproof plug into the cable gland
5. Remove an appropriated length of the jacket and insulation layer from
cable and crimp the wires with terminal
6. Use a screwdriver to fix L(Line), N(Neutral) and ground(PE) wires on the AC
terminal block from left to right side
7. Tighten cable gland firmly to fix wires and achieve waterproof effect
Note
:
Be sure to use the water-proof plugs that you put in order to achieve the waterproof function.
ES-Series
◎
ES-Series
◎
Your PV Inverter Professional
PrimeVOLT
Asian Power Devices Inc.
(Trade mark: PrimeVOLT )
www.primevolt.com
1. AC Cable Gland M25 (AC cable)
2. Signal Cable Gland M25 (Ethernet/RS485)
3. AC terminal block
4. RS485 terminal
5. RS485 terminal resistor switch
6. RS485 address selector
7. RJ45 port for Internet access
8. Ripple Control Receiver (RCR) terminal
9. USB connector
190mm418mm
485mm
Status LED
Front Cover
AC Cable
Guidance
Signal Cable
Guidance
Button & LED
Display LCD
DC (PV) Input
DC Switch
Ⓐ Ⓑ Ⓒ
Ⓓ Ⓔ Ⓕ *
Black EMI core x 1(Ethernet cable RJ45)
DescriptionItem
ⒶInverter
Ⓑ
Ⓒ
Ⓓ
Ⓔ
Ⓕ
Mounting bracket kit
User manual
M4(8mm) flat screws × 4, used for mounting bracket
Plastic anchors & screws(Φ6.5*32mm) × 3. Used to install mounting
bracket on wall
RS485 Port
RJ45 Port (Internet)
L N
② ①
③
⑨
④ ⑤ ⑥
⑦ ⑧
L N
LN
⑥
③
④
PV1(+)PV1(-)
PV2(-)PV2(+)
DC Switch
Internal fault detected
Please keep DC breaker of solar panels off
Grid voltage below range
Measured voltage displayed
AC VOLT LOW
VacXXX/XXX/XXX V
AC FREQ HIGH
fac XXX.X Hz
Grid frequency over range
Measured frequency displayed
AC FREQ LOW
fac XXX.X Hz
Grid frequency below range
Measured frequency displayed
PV VOLT HIGH
Vdc XXX/XXXV
Solar panel voltage over range
Measured voltage displayed
PV ISUL LOW Check for insulation of solar panels failed
GFC HIGH
Ig XXX mA
Leakage current high
Measured current displayed
C1
C2
High DC current detected
Relay failed
C3
C4
DC current sensor failed
Internal temperature high
C5
C7
GFCI detection failed
Anti-islanding detection failed
FAN FAILS
F1
Fan not working properly
Bus voltage low
F2
F3
Bus voltage high
CPU communication abnormal
F4
F5
Mismatch of firmware version between CPUs
EEPROM memory faulty
F6
F7
Error on system consistency
Over-current in inverter detected
F8 Slow start-up on Bus
Grid voltage over range
Measured voltage displayed
AC VOLT HIGH
VacXXX/XXX/XXX V
ES-Serial Description
■ Error Message
Input (DC)
Recommended Maximum Power W 5500
MPPT Working Range V 180 ~ 580
MPPT Range(full load) V 290 ~ 500
Maximum DC Voltage V 580
Maximum DC Current A 10x2
No. of MPP Trackers 2
Max. backfeed current to array mA 1.6
Output (AC)
Nominal Power W 5000
Maximum Power W 5000
Nominal Voltage V 220/230/240
Nominal Frequency Hz 50/60
Power Factor -0.8 ~ +0.8
Maximum Current A 23.8
Max. O/P Over-Current Protection A 45
Efficiencies
Max. Efficiency % 97.2
Euro- Eta % 96.1
General
Temp. Range °C -25 ~ 55
Temp. (Full Power) °C -20 ~ 45
Topology Transformerless
Protection IP65
Humidity % 0 ~ 100
Cooling Force-Air Cooling
Protection Class I
Overvoltage Cat. DC input:II、AC input:III
Features(ES-Series)
LCD 1602 character display
RS485 Standard, half-duplex
Network Cable Network (RJ45)、Wi-Fi(Optional)
Data Logging Yes, 3 years
Web Server Yes
Clock Synchronization Automatically sync with time server
Mechanical
W x H x D mm 418 x 485 x 190
Weight kg 22
Input Pairs 2
DC Switch Built-in
Compliances
Grid Monitoring VDE-AR-N 4105
VDE0126-1-1/A1、PEA/MEA、G83-2
Safety IEC 62109-1、62109-2
EMC EN 61000-6-2、EN 61000-6-4
EN 61000-3-11、EN 61000-3-12
Note: Specifications are subject to change without prior notice.
〇Specifications
■ Wiring Diagram
Inverter Info. PV-5000W-HV Date & Time Jan/1/2016 2:04:33
Voltage Range 184.0 ~ 264.5 V Frequency Range 50 Hz
Grid Regulation VDE-AR-N 4105
IP Address 192.168.60.43 Wi-Fi (Edit)
Auto FW Update ON Language English
Feed-in Rate $0.32 Administration admin
UPLOAD (Edit)
When in Settings sheet, you will see the table below.
■ Settings
〇Browsing Inverter Web Page(ES-Series)
■ Basics
Inverter has a built-in and multi-functional web page that user can access via LAN/
WLAN. The recommended web browsers are Internet Explorer, Firefox and Safari.
Follow the steps below to explore the inverter web page.
1. Make sure you have successfully connected inverter to a LAN by either Ethernet
or Wi-Fi.
2. Tap button to switch to “Operation Frame” to read off the inverter’s IP address.
3. Open a web browser on your desktop/laptop, key in the IP address you have
read previously at the address bar
4. Daily graphs will load soon after.
〇Network and Internet(ES-Series)
■ Accessing Inverter via LAN (Local Area Network)
The illustration above demonstrates how to access the inverter via Internet. Similar
to LAN, the inverter can be accessed by web browser. However, there is usually a
firewall that would block direct access of the LAN from the Internet. In order to
overcome this, you will need to set up NAT (Network Address Translation) or Port
Forwarding of the router. For detailed information, please refer to the manual
provided by your router supplier.
Information Board
Inverter Status
Daily Graphs
Forward/Backward Tabs
Display Tabs
■ Error Message Display
KEEP PV OFF
614-37089-02
Function Unit Specification
〇RS485 Communication Interface
■RS485 hardware interface
Address
Switch Terminal
Resistor Switch
RS485 terminal
T/R 1+ T/R 2+
T/R 1- T/R 2-
ES-Series
◎
■ Address Setup(ES-Series)
To do this setting, use the address rotary switch shown on right. For a
single inverter, set the position to “1”; for multiple inverters, please assign
them different positions with no duplications. Since only 15 positions (1~F)
are available, the maximum number of inverters that can be grouped at a
time in a RS485 bus is 15.
■ Setting the Terminal Resistor
As shown on right, “ON” indicates a resistor is added. ONLY the
terminal-end inverter (last inverter of the row) should have this switch
set to “ON”. Switches of the other inverters should be set as “OFF.”
ON
OFF
5.0kW
4.0kW
3.0kW
2.0kW
1.0kW
0.0kW
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
2016 / 01 / 01
Production
System
Now
Today
Total
Vac
Vdc
Fac
50000W
22.2kWh
23.8kWh
230V
650.1 V
50.1 Hz
Grid-Connected PV-5000W-HV DAYSETTINGS LOGS MONTH
ON
1
■ LCD display
Buttons are used to change frame display on LCD screen.
DescriptionIcon Note
LED A,Reference LED fault table A
LED B,Reference LED fault table B
LED C,Reference LED fault table C
Button
2/2
CBA
A
B
C
Pac 5000W
Etoday 50.5kWh
Computer via LAN
Router/Modem
Computer via Internet
Inverter
■ Logs
Event records of inverter. Events include activities and errors of inverter. See
picture below for demonstration
When inverter encounters an error, LCM screen enter error mode and an error
message will be displayed on LCM screen continuously. The maximum is 5 in ES-
serial For more detail content, please refer to the“error message”chapter.
2016/01/20 10:26:12 System StartedInformation
2016/02/27 15:25:24 AC FREQ HIGHError
2016/01/22 11:23:15 Frequency range changedInformation
Time EventType
■ Cloud Monitoring
Trouble Suggestions
No display or
incorrect display
No generation
(No Error)
1. Check PV wiring.
2. Check PV polarities.
3. Check PV voltages.
4. Wait for stronger sunlight.
Error on display
1. Check PV module installation.
2. Check the PV module is damaged or sheltered.
3. Ensure inverter is not in direct sun light.
4. Remove all objects on inverter.
5. Check the setting space of each inverter.
6. Check inverter’s ambient temperature and coiling condition.
Generated power
less than expected
Refer to error table in Error Frame section.
1. Error other than “C#”: Check the error message and take
suitable action.
2. “C#” Error: Switch off the AC breaker then the DC breaker.
Switch on the DC breaker then the AC breaker again.
3. If “C#” error persists, call your local service provider for
assistance.
1. Check AC connection segments such as fuses, breakers and
wires. Be sure AC is connected to inverter properly.
2. Switch AC off and on again.
■ Troubleshooting
In cases where an inverter detects a problem, an error message may be conveyed
by the system. Use the table below to resolve accordingly. If the problem persists,
contact your local service provider for further assistance.
〇Maintenance
Go to http://mypowermanager.net to download the user manual of cloud and
register your user account to set up your inverters for cloud monitoring.
1. Connect T/R+ and T/R- of RS485 converter to the T/R1+ and T/R1- of the data logger
respectively.
2. Between two data loggers, match T/R2+ and T/R2- of this inverter to T/R1+ and T/R1-
of the next inverter.
3. Set terminal resistor switch “ON” of the terminal-end inverter (last data logger of the row)
only. The others’ should be set as “OFF.”
4. Connect data logger and router of RJ45 Cable.
T/R -
T/R +
T/R -  T/R1 -
T/R +  T/R1 +
RJ45 Cable
RJ45 Cable
Data
Logger Router
Pin:Off Pin:Off Pin:On
Inverter
RS485 Connector
ON
1
Inverter
RS485 Connector
ON
1
Inverter
RS485 Connector
ON
1
〇Operation
ES-Series
◎
■ Status LED
The LED on the inverter right side will show the inverter operation status by
different colors. In normal operation, the LED appears in green color; in error
circumstance, it appears in red color.
IndicationStatus
Solid Green: Inverter is standing by/operating (day).
Flashing Green: Inverter is standing by (evening/night).
Solid Red: Inverter is having a fault.
Inverter is not connected to AC.
■ LED Fault and LED Indication
Error Message
LED A LED CLED B
Off Off Off All Normal
ON Off Off High DC Current Detected
Off ON Off Relay(s) Failed
ON
Off Off DC Current Sensor(s) Failed
ON ON Off Internal Temperature High
Bus Failed
GFCI Detection Failed
ON Off ON
Off ON ON
Check for insulation of solar panels failed
Leakage Current High
Fan not Working Properly
Blink Off
Off Off
Blink
Off Off Blink
Note:Blinking means LEDs on for 0.5 seconds and off for 0.5 seconds.
LED fault table
AC VOLT HIGH
Vac 271/ 262/ 261V
■ Operation Chart
The inverter error that has occurred most recently is generally recorded by the
history error.
■ Error Message Display
History Error
Message Record
Output Power
Daily Energy
LAN IPWi-Fi IP
AC Voltag e
AC Current
Safety M ode
Model
F/W V ersion
Modbus
Adress
5 Seconds
WELCOME
DC Voltage
DC Current
E-Total
H-Total
Date/Ti me
VAC/FAC
Range Erro r Record
Clock
Setting
F/W V ersion
History Erro r
Record
Press
Press 5 Seconds
Press5 Seconds
5 Seconds
When inverter has connected to electrical grid and started generating power, the
LCM screen enters regular mode. The LCD display flow chart sequence of on-screen
information is as the frames as below.
Off
Your PV Inverter Professional
PrimeVOLT
Your PV Inverter Profess ional
PrimeVOLT
E S -Series offers basic logger functionalities with simple and necessary on-
screen information form.
The production using for RS48 5 o r RJ 4 5 to monitor the inverter working
status, and provide the LED and LCD display, the LCD is 16*2 character type.
The LED panel has three LED lights and one button. When a fault occurs, one
or two or three LED lights will be blinking in response.
The display content s include output power、grid voltage & current、PV
module voltage & current、energy of today (E-Today )、accumulated energy
( E- T o t a l) 、totally oper a t io n time (H-To t al) 、regulation setting ( Safe t y
Mode)、model name and firmware version.

Other PrimeVOLT Inverter manuals

PrimeVOLT PV 5KTL-D3/G2 User manual

PrimeVOLT

PrimeVOLT PV 5KTL-D3/G2 User manual

PrimeVOLT PV-5000T-U User manual

PrimeVOLT

PrimeVOLT PV-5000T-U User manual

PrimeVOLT PV T U Series User manual

PrimeVOLT

PrimeVOLT PV T U Series User manual

PrimeVOLT PV-3000N-V User manual

PrimeVOLT

PrimeVOLT PV-3000N-V User manual

PrimeVOLT PV2KTL-S1/G2P User manual

PrimeVOLT

PrimeVOLT PV2KTL-S1/G2P User manual

PrimeVOLT PV-3000S-V User manual

PrimeVOLT

PrimeVOLT PV-3000S-V User manual

PrimeVOLT PV 7KTL-D1P User manual

PrimeVOLT

PrimeVOLT PV 7KTL-D1P User manual

PrimeVOLT V-3000N-V User manual

PrimeVOLT

PrimeVOLT V-3000N-V User manual

PrimeVOLT PV 2KTL-S1/G2P User manual

PrimeVOLT

PrimeVOLT PV 2KTL-S1/G2P User manual

PrimeVOLT PV 4K6HB-60 User manual

PrimeVOLT

PrimeVOLT PV 4K6HB-60 User manual

Popular Inverter manuals by other brands

Omnik New Energy Omniksol-1.5k-TL user manual

Omnik New Energy

Omnik New Energy Omniksol-1.5k-TL user manual

Agilent Technologies 33250A user guide

Agilent Technologies

Agilent Technologies 33250A user guide

4-noks ZR-SWITCH-RC instruction manual

4-noks

4-noks ZR-SWITCH-RC instruction manual

V&T V5 Series user manual

V&T

V&T V5 Series user manual

Hon Turing HT-T-S1000-12 introduction

Hon Turing

Hon Turing HT-T-S1000-12 introduction

Metabo E 140 SP Plus Original operating instructions

Metabo

Metabo E 140 SP Plus Original operating instructions

BARRON EXITRONIX Tucson Micro Series installation instructions

BARRON

BARRON EXITRONIX Tucson Micro Series installation instructions

Baumer HUBNER TDP 0,2 Series Mounting and operating instructions

Baumer

Baumer HUBNER TDP 0,2 Series Mounting and operating instructions

electroil ITTPD11W-RS-BC Operation and Maintenance Handbook

electroil

electroil ITTPD11W-RS-BC Operation and Maintenance Handbook

Silicon Solar TPS555-1230 instruction manual

Silicon Solar

Silicon Solar TPS555-1230 instruction manual

Mission Critical Xantrex Freedom SW-RVC owner's guide

Mission Critical

Mission Critical Xantrex Freedom SW-RVC owner's guide

HP 3312A Operating and service manual

HP

HP 3312A Operating and service manual

Hoymiles HM-500T user manual

Hoymiles

Hoymiles HM-500T user manual

Nitecore SPM10 user manual

Nitecore

Nitecore SPM10 user manual

AEG Protect PV installation manual

AEG

AEG Protect PV installation manual

On Board TruePower Plus 1200MS owner's manual

On Board

On Board TruePower Plus 1200MS owner's manual

Plugreen PGM-200P-230 Installation and operation manual

Plugreen

Plugreen PGM-200P-230 Installation and operation manual

Fourgroup Easy use and Programming Handbook

Fourgroup

Fourgroup Easy use and Programming Handbook

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.