Primus FS 6-16 Manual

FS 6-16
INSTALLATION AND MAINTENANCE MANUAL SOFT MOUNTED WASHER EXTRACTOR
PUBLICATION DATE : 05/02 WITH ELECTRONIC PROGRAMMER
100646

100 646 PUB.DATE : 05/02 INSTALLATION AND MAINTENANCE MANUAL 1
1. TABLE OF CONTENTS
Publication date : 05/02
1. TABLE OF CONTENTS ................................................................................................ 1
2. WARNINGS ................................................................................................................... 2
3. TECHNICAL INFORMATION ........................................................................................ 3
4. MACHINE INSTALLATION........................................................................................... 7
4.1. MACHINE INSPECTION ....................................................................................................................7
4.2. MACHINE STORAGE.........................................................................................................................7
4.3. MACHINE POSITIONING...................................................................................................................7
4.3.1 FREELY ON THE FLOOR............................................................................................................8
4.3.2 FREELY ON AN ELEVATION. .....................................................................................................8
4.3.3 FIXED ON AN ELEVATION..........................................................................................................9
4.3.4 LEVELING THE MACHINE ........................................................................................................10
4.4. SHIPPING BARS..............................................................................................................................10
4.5. ELECTRICAL CONNECTION...........................................................................................................12
4.6. CONNECTION OF WATER SUPPLIES ............................................................................................15
4.7. CONNECTION OF LIQUID WASHING SOAPS DOSING..................................................................17
4.8. PREPARING THE MACHINE FOR OPERATION..............................................................................18
5. MAINTENANCE AND ADJUSTMENTS...................................................................... 19
5.1. MAINTENANCE ...............................................................................................................................19
5.2. ADJUSTMENTS AND PART´S EXCHANGES ..................................................................................20
6. TROUBLESHOOTING AIDS ....................................................................................... 25
6.1. ERROR HANDLING .........................................................................................................................25
6.2. PROBLEM CHECK LIST ..................................................................................................................25
6.3. DOOR FAILS TO OPEN ...................................................................................................................27
7. LIST OF RECOMMENDED SPARE PARTS............................................................... 28
8. PUTTING THE MACHINE OUT OF SERVICE ............................................................ 29

2 INSTALLATION AND MAINTENANCE MANUAL PUB.DATE : 05/02 100646
2. WARNINGS
FAILURE TO COMPLY WITH THE INSTRUCTIONS IN THIS MANUAL MAY LEAD TO INCORRECT USE
OF THE WASHER EXTRACTOR, AND MAY RESULT IN BODILY INJURIES OR DEATH AND/OR
DAMAGE TO THE LAUNDRY AND/OR THE WASHER EXTRACTOR.
♦This English version is the original version.
♦This instruction is not complete without "User manual“, "Installation and Maintenance manual“, "Programming manual“, ”Spare-parts
manual” and "Instruction manual for frequency invertor.
♦Before installing, operating or maintaining the machine, read and follow these instructions carefully and keep them in a handy place for
later use. Safety instructions included in manuals for personnel operating the washing machine must be printed and posted on a visible
place near the machine in the laundry room.
♦Follow all basic and valid safety instructions and laws. Do not bypass the instructions stated in the instruction manual and warnings on
the labels. The labels must stay on the machine and they must be legible.
♦Installation and service can be done only by a service organization with proper authorization.
Do not let children use, play in, on, or around the machine.
♦Any changes concerning the installation which are not described in this Installation Manual must be approved by the supplier or
manufacturer. Otherwise, the supplier and manufacturer are not responsible for potential injuries to operators or for any damages.
Interventions in the machine execution or functions are not allowed, and the manufacturer refuses any responsibility in such cases.
♦During transportation and storage never use excessive forces on the carton box because components can be damaged protruding the
contour line of the machine.
♦The washer extractor must be installed on level. If not, the machine may become unbalanced during extraction and, although fitted with
an unbalance safety, the machine may become seriously damaged what may result in bodily injuries.
♦Never transport the machine without the transporting braces mounted.
♦Never put the machine in operation when the transporting braces are not removed.
♦To prevent the possibility of electrical shock, make sure the washer has been properly grounded in accordance with the installation
instructions and ALL local codes.
Use copper conductors only. This appliance must be connected to a supply circuit to which no lighting units or general-purpose
receptacles are connected.
♦The machine must be connected to the power, ground, water, ventilation and steam supply according to the Installation manual, in
compliance with the local standards done by qualified technicians with proper authorization. The valid standards for connecting to the
local power network (TT / TN / IT, ...) must be followed.
♦All machines types are produced according the EMC-directive (Electro-Magnetic-Compatibility). They can be used in restricted
surroundings only (comply minimally with class A requirements). For safety reasons there must be kept the necessary precaution
distances with sensitive electrical or electronic device(s).
♦If you have a machine with frequency inverter do not change the parameters of the inverter. Doing so can cause serious injury, fire,
machine damage, etc.
♦Before removing top or back panel of the machine, switch power off and wait for at least 10 minutes. Before starting inspection of frequency
inverter, check for residual voltage across main circuit terminals + and -. This voltage must be below 30 VDC before you can access
the inverter for inspection.
♦The washer extractor is intended to be permanently connected to fixed wiring.
♦The washer must not be operated when the finger protection rubbers are removed or damaged.
♦Do not expose the washing extractor to excessive humidity or extreme temperatures.
♦Keep the top of the machine clean, without the presence of flammable materials. Do not wash or spray the machine with running water.
♦Do not operate the washer extractor when parts are broken or missing or when covers are open. The machine may not operate until the
fixed guards are put correctly in place.
♦Do not tamper with the washer extractor controls and do not bypass the safety instructions and the warnings.
♦Do not store flammable materials around the machine.
♦Define the dangerous areas in the laundry room and obstruct an admission to them during machine's operating.
♦Carefully read and follow the instructions on the packaging of detergents. Observe all warnings, cautions and labels to avoid personal
injury. Store detergents, laundry aids and disinfectants out of reach of children, preferably in a locked cabinet.
Do not put articles soiled with explosif solvents and/or dangerous chemical products in the machine for any reason.
Do not open door until cylinder remains stopped and water has been drained from cylinder.
♦Always disconnect the power supply and close all water and steam valves while servicing the washer extractor.
♦Although the washer may be in the “off” position, there is still electrical power to the switch supply terminals.
Do not repair or adjust belt drive when the machine is in operation. Do not repair or replace any part of the washer, or attempt any
servicing unless specifically recommended in the maintenance instructions.
Original or identical parts must be used for replacement in this washer extractor. After servicing replace and secure all panels in the
original way. Take these measures for continued protection against electrical shock, injury, fire and/or property damage.
♦If steam is leaking, turn off the main steam supply and contact the maintenance worker.
♦Turn off the main supply like water, steam, electricity at the end of each operating day.
♦Check the functioning of the door lock mechanism on regular base.
♦Regularly once a three months check the proper function of ground and emergency button.
♦If the installed machines operates with coin, token or similar operation, then the owner-installer must provide a remote-located
emergency stop device. This device must be placed in such a way that it is easy and safely accessible for the users. The emergency
stop device takes care that at least the control circuit of the washer extractors is interrupted.
♦Under certain conditions, hydrogen gas may be created in the hot water system that has not been used for two or more weeks.
Hydrogen gas is explosive. If the hot water system has not been used for such period open all hot water taps and let the water run out
for few minutes. This will release any accumulated gas. As this gas is flammable, do not smoke or use open flames during this time.
♦The instructions and warnings described in this manual do not include all conditions and situations which may occur during the
installation, maintain or operate of your machine. They must be generally understood. Caution and care are factors which are not
included in the design of this machine and all persons who install, operate or maintain the machine must be qualified and familiar with
the operating instructions.
♦If any problems or failures occur which you do not understand, immediately contact your dealer, serviceman or manufacturer.
= Warnings and labels present on the machine

100 646 PUB.DATE : 05/02 INSTALLATION AND MAINTENANCE MANUAL 3
3. TECHNICAL INFORMATION
60L 75L 95L 165L
LOAD CAPACITY OF DRY
LINEN (1/10)
6 kg/13,2 lb 7,3 kg/16.1 lb 10 kg/21 lb 16.5 kg/36.4 lb
DIMENSIONS
CABINET DIMENSIONS
Width 660 mm/25.98" 660 mm/25.98" 660 mm/25.98" 830 mm/32.6”
Depth 680 mm/26.77" 680 mm/26.77" 780 mm/30.71” 960 mm/37.8”
Height 1050mm/41.34" 1050mm/41.34" 1110mm/43.70” 1285 mm/50.5"
PACKING DIMENSIONS
Width 750 mm/29.53" 750 mm/29.53" 750 mm/29" 913 mm/36”
Depth 845 mm/33.27" 845 mm/33.27" 945 mm/27.56" 1123 mm/44.2”
Height 1215mm/47.83" 1215mm/47.83" 1275mm/40.35" 1500 mm/59"
Transportation volume 0.77m3/27.19ft30.77m3/27.19 ft30.90m3/31.92 ft31.68m3/59.3 ft3
DIMENSIONS OF INNER DRUM
Diameter 530 mm/20.86" 530 mm/20.86" 530 mm/21" 650 mm/25.6”
Depth 270 mm/10,63" 330 mm/10,6" 420 mm/16.5" 500 mm/19.7”
Drum Volume 60dm3/15.85gal 73dm3/19.28gal 95dm3/25.1gal 166dm³/43.8gal
WEIGHT
Net 207 kg 210 kg 250 kg 390 kg
Gross 223 kg 226 kg 268 kg 415 kg
ELECTRICAL DATA
1AC 220-240V 50/60Hz X X X X
3AC 220-240V 50/60Hz X X X X
3AC 380-415V + N 50/60Hz X X X X
Permitted deviation of voltage -6% to +10% V -6% to +10% V -6% to +10% V -6% to +10% V
Permitted deviation of frequency ±1% Hz ±1% Hz ±1% Hz ±1% Hz
TOTAL INPUT OF THE
MACHINE WITH
Electric heating 6kW 6.75 kW 6.75 kW 7.5 kW -
Electric heating 9 kW 9.75 kW 9.75 kW 10.5 kW -
Electric heating 12 kW - 12.75 kW 13.5 kW 14.2kW
Electric heating 18 kW - - - 20.2kW
Without heating or steam 0.75 kW 0.75 kW 1.5 kW 2.2kW
Nominal output of motor 0.75 kW 0.75 kW 1.5 kW 2.2kW
WASHING FUNCTIONS
Washing 42 RPM 42 RPM 42 RPM 42 RPM
High extracting 1000 RPM 1000 RPM 1000 RPM 1000 RPM
G-factor 300 300 300 363

4 INSTALLATION AND MAINTENANCE MANUAL PUB.DATE : 05/02 100646
CONNECTION
WATER CONNECTION
Water pressure 0.1-0.8 MPa/
1-8 bar /
14.5-116 PSI
0.1-0.8 MPa /
1-8 bar /
14.5-116 PSI
0.1-0.8 MPa /
1-8 bar /
14.5-116 PSI
0.1-0.8 MPa /
1-8 bar /
14.5-116 PSI
Recommended water pressure 0.25 MPa /
2.5bar/36.3 PSI
0.25 MPa /
2.5bar/36.3 PSI
0.25 MPa /
2.5bar/36.3 PSI
0.25 MPa /
2.5bar/36.3 PSI
Water inlet G3/4" BSP G3/4" BSP G3/4" BSP G3/4" BSP
Maximal water temperature 90°C / 194°F 90°C / 194°F 90°C / 194°F 90°C / 194°F
CONNECTION OF WATER
DRAINAGE
Via drain valve diameter 76 mm/3" 76 mm/3" 76 mm/3" 76 mm/3"
Flow amount with drain valve 3.5 l/s 3.5 l/s 3.5 l/s 3.5 l/s
CONNECTION OF STEAM
Steam connection G1/2” G1/2” G1/2” G1/2”
Steam pressure low 1-3 bar 1-3 bar 1-3 bar 1-3 bar
Steam pressure high 3-8 bar 3-8 bar 3-8 bar 3-8 bar
ELECTRICAL CONSUMPTION
Light soiled fabrics,wash 60°C(1)
Without electrical heating 0.2 kWh 0.2 kWh 0.3 kWh 0.5kWh
With electrical heating 1.2 kWh 1.3 kW 1.7 kW 3.5kWh
WORKING CONDITIONS
Ambient temperature +5°C (41°F) to
+35°C (95°F)
+5°C (41°F) to
+35°C (95°F)
+5°C (41°F) to
+35°C (95°F)
+5°C (41°F) to
+35°C (95°F)
Relative humidity 30% to 90%
without
condensation
30% to 90%
without
condensation
30% to 90%
without
condensation
30% to 90%
without
condensation
Heigth above sea level up to 1000 m /
3280 ft
up to 1000 m /
3280 ft
up to 1000 m /
3280 ft
up to 1000 m /
3280 ft
Storage temperature 0°C (32°F) to
+55°C (131°F)
0°C (32°F) to
+55°C (131°F)
0°C (32°F) to
+55°C (131°F)
0°C (32°F) to
+55°C (131°F)
BOTTOM LOAD
Max.static load on floor 2413 N 2492 N 3002 N 5450N
Max.dynamic load on floor 650 N 730 N 1100 N 1220 N
Frequency of dynamic load 16 Hz 16 Hz 16 Hz 16Hz
NOISE
Equivalent sound power level
Leq (dB(A))
< 70 dB(A) < 70 dB(A) < 70 dB(A) < 70 dB(A)
(1) Depends of temperature of cold and hot water supply

100 646 PUB.DATE : 05/02 INSTALLATION AND MAINTENANCE MANUAL 5
60/75/95 L machines 165 L machine with frequency control drive
Fig. 3.1.
1. Control panel
2. Connection liquid soap
3. Serial plate
4. Soap hopper venting
5. Water supply
6. Frequency convertor
7. Fuses
8. Main switch
9. Electrical supply connection
10. Drain
11. Adjustable leg
12. Steam connection
13. Soap hopper
14. Emergency/Coin system

6 INSTALLATION AND MAINTENANCE MANUAL PUB.DATE : 05/02 100646
CAPACITY 60L CAPACITY 75L CAPACITY 95L CAPACITY 165L
A 660 mm / 25.98” 660 mm / 25.98” 660 mm / 25.98” 830 mm / 32.68”
B 685 mm / 26.97” 685 mm / 26.97” 785 mm / 30.91” 960 mm / 37.8”
C 1070 mm / 42.13” 1070 mm / 42.13” 1130 mm / 44.49” 1285 mm / 50.54"
D 560 mm / 22.05” 560 mm / 22.05” 560 mm / 22.05” 715 mm / 28.15”
E 585 mm / 23.03” 585 mm / 23.03” 685 mm / 26.97” 815 mm / 32.09”
F 20 mm / 0.79” 20 mm / 0.79” 20 mm / 0.79” 0 mm / 0”
G 420 mm / 15.54” 420 mm / 15.54” 480 mm / 18.90” 430 mm / 16.92"
H 263 mm / 10.35” 263 mm / 10.35” 263 mm / 10.35” 300 mm / 11.81”
I 910 mm / 35.83” 910 mm / 35.83” 970 mm / 38.19” 1135 mm / 44.68"
J 103 mm / 4.06” 103 mm / 4.06” 103 mm / 4.06” 120 mm / 4.72”
K 980 mm / 38.58” 980 mm / 38.58” 1040 mm / 40.94” 1195 mm / 47"
L 44 mm / 1.73” 44 mm / 1.73” 44 mm / 1.73” 44 mm / 1.73”
M 835 mm / 32.87” 835 mm / 32.87” 895 mm / 35.24” 1015 mm / 39.95"
N 78 mm / 3.07” 78 mm / 3.07” 78 mm / 3.07” 55 mm / 2.36”
O 375 mm / 14.76” 375 mm / 14.76” 375 mm / 14.76” 415 mm / 16.34”
P 10 mm / 0.39” 10 mm / 0.39” 10 mm / 0.39” 15 mm / 0.6”
Q 445 mm / 17.52” 445 mm / 17.52” 445 mm / 17.52” 530 mm 20.86"
R 700 mm / 27.56” 700 mm / 27.56” 700 mm / 27.56” 700 mm / 27.55”
S 600 mm / 23.6” 600 mm / 23.6” 600 mm / 23.6” 600 mm / 23.6”

100 646 PUB.DATE : 05/02 INSTALLATION AND MAINTENANCE MANUAL 7
4. MACHINE INSTALLATION
4.1. MACHINE INSPECTION
When the machine is delivered, it is necessary to do a visual inspection for any damage that may have
occurred during transit. If the package or pallet are damaged or signs of possible damage are evident, let
the carrier note the condition on the shipping papers before the shipping receipt is signed.
Remove the package as soon as possible and check if the information on the serial plate correspond with
your order. The serial plate is located on the rear of the machine, fig. 4.1. This determines the type of model
you have bought, the voltage and the serial number.
Fig. 4.1.Serial plate
Check if the machine is not damaged and if all the accessories are included according to your order. The
accessories and manuals are located inside the machine.
4.2. MACHINE STORAGE
When the machine will be stored after delivery, be sure this is followed:
- Use the delivered package to protect the machine against moisture and dirt.
- The storage temperature is between 0°C and 55°C.
- The machine may not be installed within the reach of spraying water.
- Avoid severe climatic storage conditions and excessive humidity. When the temperature changes and this
causes damp, you must avoid water under and around the machine and also on his covers.
- If possible, leave the machine in the transporting package or at least let it set on the transporting wooden
id until the time of final installation on the foundation according the chapter 4.3. of this manual.
4.3. MACHINE POSITIONING
WARNING !
IF THE MACHINE IS LOCATED ON AN ELEVATED BASE FOR EASIER OPERATION, THE FRONT
LEGS OF THE MACHINE SHOULD BE SERCURED FOR SAFETY REASONS.
- Before placing the machine on its place, remove the packaging, loosen the rear panel (see fig. 4.4. pos 4)
and the service panel (see fig. 4.4. pos 5). Remove the four bolts, which holds the machine on the wooden
pallet. Lift up the machine carefully, take care not to damage the machine components.
- Leave at least a 0.6 m / 23,6“ free space between the rear panel of machine and the wall. Leave at least a
0.01 m / 0.39" free space between the side panel of the machine and the wall or other machine. Above the
machine must be minimum 0.7 m / 27.56” of free space for the maintenance access.
- All passages and spaces the machine has to be transported through at installation should be reasonably
dimensioned to meet the height and width of the machine including the package.
- Never push, pull or press the components protruding from the contour line of machine(control panel, door,
control elements, water inlet and outlet pipes, etc.).
- Make sure that the filling door is closed during handling.
- Take care that the floor where the machines will be placed is underneath supported. The washer should
not be installed on an upper floor or over a basement without approval of structural engineer about the
requirements of permissible loading, vibrations and noise level in the building.
- Take care that the floor where the machines will be placed is not combustible.
!

8 INSTALLATION AND MAINTENANCE MANUAL PUB.DATE : 05/02 100646
4.3.1 FREELY ON THE FLOOR
The machine is to be located on a not elevated leveled concrete floor that comply with static and dynamic
stress of the machine.
The friction coefficient must be higher then 0,5 between the rubber feet and the floor material. Do not place
the machine on a smooth surface but on a rough floor material like concrete. If the friction coefficient is less,
then the machine can move while spinning. If this should happens fasten the machine, see “Fasten with
achoring bolts”.
For 60, 75and 95 liter machines
Position the machine only on his 4 adjustable rubber feet.
For 165 liter machines
Place between the four corners of the frame and the floor a thin rubber sheet of 10 x 10 cm with thickness
between 1 en 2 mm maximum. We advice to fasten this machines always, see “Fasten with achoring bolts”.
4.3.2 FREELY ON AN ELEVATION.
Only for 60, 75 and 95 liter machines.
If you choose to place the machine on a metal base or pad, use a U-profile to secure the machine position.
Fix the U-profile to the iron frame by welding or fix it to the floor by ancoring bolts. This is necessary to
prevent that the machine moves from the base. Make a base according, fig. 4.3.2.
Place the machines front rubber feet in the U-profile.
Fig. 4.3.2. Design of metal base
Capacity 60L Capacity 75L Capacity 95L
Distance A 660 660 760
Distance B 480 480 480
Distance C 590 590 590
Tab 4.3.2. Distances Frame
WARNING ! NEVER DO THIS FOR A 165 LITER MACHINE
!

100 646 PUB.DATE : 05/02 INSTALLATION AND MAINTENANCE MANUAL 9
4.3.3 FIXED ON AN ELEVATION
The machine can also be secured to a mounting base or foundation by means of bolts and anchoring bolts
to assure the safety. When a concrete pad or a frame is used then is the maxium height 305 mm (12”). The
pad or frame must be designed so that it can carry the static and dynamic forces. The tickness of iron
profiles is minimuim 4 mm (0.158”).
For 60, 75 and 95 liter machines, remove the four rubber feeds from the machine frame.
Do not tighten anchoring bolts before the concrete base around the bolts is completely secured.
Tighten the anchoring bolts with the prescribed torque of the bolts.
Fig. 4.3.3.A On an elevatation
Fig. 4.3.3.B Frame fixation dimensions
1. Bolt M8
2. Securing nut
3. Nut M8
4. Machine frame
5. Washer
6. Elevation frame
7. Concrete floor
8. Ancoring bolt

10 INSTALLATION AND MAINTENANCE MANUAL PUB.DATE : 05/02 100646
Capacity 60L Capacity 75L Capacity 95L Capacity 165L
X1 660 mm / 25.98” 660 mm / 25.98” 660 mm / 25.98” 830 mm / 32.7”
X2 560 mm / 22.05” 560 mm / 22.05” 560 mm / 22.05” 715 mm / 28.1”
X3 50 mm / 1.97” 50 mm / 1.97” 50 mm / 1.97” 57.5 mm / 2.3”
X4 685 mm / 26.97” 685 mm / 26.97” 785 mm / 30.91” 960 mm / 37.8”
X5 455 mm / 17.91” 455 mm / 17.91” 565 mm / 22.24” 815 mm / 32.09”
X6 130 mm / 5.12” 130 mm / 5.12” 130 mm / 5.12” 80 mm / 3.15”
X7 110 mm / 4.33” 110 mm / 4.33” 110 mm / 4.33” 130 mm / 5.2”
Tab 4.3.3. Distances anchoring bolts
4.3.4 LEVELING THE MACHINE
WARNING !
THE MACHINE MUST RELIABLY REST IN ALL FOUR CORNERS OF THE MACHINE!
THE MACHINE MAY NOT ROCK.
THE MACHINE MUST BE IN WATER LEVELLED POSITION.
For 60, 75 and 95 liter machines
The rubber feets are screwed on the bottom of the machine frame and are adjustable with a wrench size 13
and 17 mm. Check the position of the top of the machine by a water level and adjust machine legs, fig.3.1,
pos.11. Adjust the four rubber feet until the machine is leveled and tighten the nuts M10 back to the bottom
of the frame.
For 165 liter machines
The 165 liter machines don’t have rubber feets for adjustment to water level. When it is necessary use thin
hard plates of 10 x 10 cm with thickness of 1 mm and place them under the frame corner of the lowest
position. Use more of them until the machines stands water level. It is always adviseable to bolt down this
machine after leveling.
Take care that the machine is in the lowest possible position.
If the machine with his cabinet rocks can it damage the machine cabinet.
The manufacturer is not responsible for consequences caused by a wrong installation.
4.4. SHIPPING BARS
WARNING !
DO NOT TRY TO OPERATE THE MACHINE WITHOUT REMOVING THE SHIPPING BARS
DO NOT TRANSPORT THE MACHINE WITHOUT SHIPPING BARS MOUNTED.
OTHERWISE THIS CAN LEAD TO INJURY TO PEOPLE AND CAN DAMAGE THE MACHINE.
The machine is blocked for transport. This eliminates all possible movement of the tub during transportation.
There are 3 striking shipping bars which must be removed before putting the machine into operation.
1. Remove fixation plate front, fig. 4.4. pos 1.
2. Remove fixation plate rear right, fig. 4.4. pos 2.
3. Remove fixation plate rear left, fig. 4.4. pos 2.
IMPORTANT : UNSCREW ONLY THE NUTS WHERE INDICATED !
!
!

100 646 PUB.DATE : 05/02 INSTALLATION AND MAINTENANCE MANUAL 11
After removing the shipping bars put the service panel, fig. 4.4. pos 3 and the rear panel, fig. 4.4. pos 4
back on the machine. Keep the shipping bars pos 1,2 for possible future transportation.
Fig. 4.4. Transporting braces

12 INSTALLATION AND MAINTENANCE MANUAL PUB.DATE : 05/02 100646
4.5. ELECTRICAL CONNECTION
WARNING !
THE MACHINE MUST BE CONNECTED TO THE POWER, GROUND, WATER, VENTILATION AND
STEAM SUPPLY ACCORDING TO THE INSTALLATION MANUAL, IN COMPLIANCE WITH THE
LOCAL STANDARDS DONE BY QUALIFIED TECHNICIANS WITH PROPER AUTHORIZATION. THE
VALID STANDARDS FOR CONNECTING TO THE LOCAL POWER NETWORK (TT / TN / IT, ...) MUST BE
FOLLOWED.
GENERAL
The machine has been designed for connecting to the electrical network according to the specifications of
your order. Before connection check if the electrical values stated on the serial plate of the machine
correspond to your electrical network. If not do not connect the machine, please contact your dealer. If the
machine is not equipped with a main switch then supply disconnecting devices need to be provided in the
installation for all electrical supplies connected to the machine, in accordance with EN 60204-1 standard,
point 5.3.
WARNING !
ONLY AUTHORIZED WORKERS WITH A VALID QUALIFICATION MUST EXECUTE THE ELECTRICAL
CONNECTION OF THE MACHINE ACCORDING TO THE VALID LOCAL STANDARDS.
Fig. 4.5.A. Example of electrical connection
SUPPLY CABLE AND SAFETY DEVICES
If there is no mainswitch at the back of the machine, there must be installed a circuit breaker (with
properties according to the local standards) to isolate each washer for a safe disconnecting of the machine,
e.g. maintenance.
Supply cable of the machine must have copper wires. The cross section of the supply wires depends on the
supply voltage and on the total electrical power input of the machine (see table 4.3). The supply cable
safety device against a short-circuit fault and overloading must be performed by automatic breakers or
fuses in the laundry switchboard. The recommended minimal cross-section of the supply wires as well as
the values of fuses (F) for the supply are stated in table 4.5.
In all cases were the local standards requirments are higher, these has to be followed above the
recommendation in table 4.5. If the local standards say that there must be installed a differential (leakage)
current breaker we suggest to install one of 100 mA eqiupped with invertor drive, 30 mA for convential
motor system.
!
!

100 646 PUB.DATE : 05/02 INSTALLATION AND MAINTENANCE MANUAL 13
ELECTRIC HEATING:
EXECUTION:
Without
electrical
heating
6000 W 9000 W 12000 W 18000 W
Fuse
breaker
cross
section
Fuse
breaker
cross
section
Fuse
breaker
cross
section
Fuse
breaker
cross
section
Fuse
breaker
cross
section
1AC 220-240V
+PE
2xD16 2 + 1
2.5mm²
////////
3AC 200-240V
+PE
3xD16 3 + 1
2.5mm²
////////
3AC 380-415V
+N+PE
4xD16 4 + 1
2.5mm²
4 x C16 4 + 1
2.5mm²
4 x C20 4 + 1
2.5mm²
4 x C25 4 + 1
4mm²
4 x C40 4 + 1
6mm²
3AC 220-240V
+PE
3xD16 3 + 1
2.5mm²
3 x C25 3 + 1
4 mm²
3 x C32 3 + 1
4mm²
3 x C40 3 + 1
6mm²
3 x C60 3 + 1
10 mm²
3AC 440V
+PE
3xD16 3 + 1
2.5mm²
3 x C16 3 + 1
2.5mm²
3 x C20 3 + 1
2.5mm²
3 x C25 3 + 1
4mm²
3 x C32 3 + 1
4mm²
Tab 4.5. The values of securing and minimal wire section recommended by the manufacturer
SUPPLY CABLE CONNECTION TO THE MAC H INE
WARNING !
THE PROTECTIVE CONDUCTOR MUST BE LONGER SO THAT WHEN THE CABLE IS PULLED OUT
ACCIDENTALLY, THIS CONDUCTOR IS DISCONNECTED AS THE LAST ONE!
WARNING !
THE WASHER EXTRACTOR IS INTENDED TO BE PERMANENTLY CONNECTED TO FIXED WIRING.
Push the cable through the turnbuckle and connect the wires with the main switch. The diameter of the
supply cable must between 10-14 mm for PG16 turnbuckle and between 13-18 mm for PG21 turnbuckle.
Conductors of the supply cords shall not be consolidated by lead-tin soldering where they are subject to
contact pressure, unless the clamping means is constructed so that there is no risk of a bad contact due to
cold flow of the solder.The phase terminals are marked by L1, L2 and L3. A separate insulated terminal,
labeled N, is provided for the neutral wire. Connect the protection earth wire directly to the protection earth
terminal (marked PE) located on the rear bridge. Tighten the cap nut of the turnbuckle. By this way the
rubber ring in the turnbuckle is pressed, thus securing the cable mechanically and against water. If there’s
no mainswitch the terminals are marked in the same way so also the connection is the same. Depending on
your supply voltage it is possible that L2 and L3 (1 AC) or N (3 AC without Neutral) must not be connected.
If the cable is attached from above, it is recommended to make a sagging on the cable in front of its entry
into the cable turnbuckle. In this way an ingress of the running condensed water into the bush and/or
machine can be avoided. The manufacturer recommends to attach the cable from beneath.
1. L1,L2,L3 and N terminal
2. Turnbuckle
3. Turnbuckle nut
4. PE terminal
Fig. 4.5.B. Example of supply cable connection
!
!

14 INSTALLATION AND MAINTENANCE MANUAL PUB.DATE : 05/02 100646
CHECKING ROTATION DIRECTION
CHECK IF THE DRUM ROTATES FROM THE FRONT VIEW IN CLOCKWISE DIRECTION DURING
EXTRACTION. IF IT ROTATES IN OPPOSITE DIRECTION, DISCONNECT TWO PHASES OF THE
CONNECTION FROM THE FREQUENCY CONVERTOR TO THE MOTOR , SWITCH THEM OVER AND
CHECK AGAIN THE ROTATION DIRECTION.
Fig. 4.5.C. Spin direction
MULTIPLE MACHINES IN LINE SIMPLE PHA SE
When multiple single phase machines are connected to the same electrical network, it is necessary to
connect the machines according to fig. 4.9. The phase of the frequency control and motor which is
connected to the terminal inside the machine, has to be connected alternatively for the first machine with
the first phase L1 of the network, the second machine with the second phase L2, … The fourth machine
must again be connected to the first phase L1. This assures a better load of the electrical network.
Fig. 4.5.D. Multiple machines in line

100 646 PUB.DATE : 05/02 INSTALLATION AND MAINTENANCE MANUAL 15
4.6. CONNECTION OF WATER SUPPLIES
WATER CONNECTION
WATER HARDNESS
It is advisable to contact the water supplier for information concerning the properties of the water in your
area. Good wash results are dependent also on the water hardness. For medium to very hard water,
consideration should be made to make the water softer.
Only in some cases is the use of hard water desirable, such as adding softener in the linen.
The soap supplier can help you with making the right decisions concerning hard water, soft water, washing
programs, type of soap and other related items to have the best wash results.
Characteristics mmol / dm3dH -
Germany
fH -
France England gr/gal
USA
soft 0 - 1,25 0 - 7° 0 - 12° 0 - 8,75° 0 - 3
medium 1,25 - 2,5 7 - 14° 12 - 25° 8,75 - 17,5° 3 - 7
hard 2,5 - 3,75 14 - 21° 25 - 37° 17,5 - 26,3° 7 - 15
very hard above 3,75 above 21° above 37° above 26,3° above 15
Tab.4.6.A.
HOT WATER
When the machine is provided with a hot water inlet, we advise connecting this inlet to a hot water supply
that is set to 70°C – 158°F. The hot water supply needs to be large enough to provide the required hot
water for the washers.
WATER CONNECTION
Most machines are made with 2 or 3 water inlets. One is always marked with „soft water“. If more inlets are
present, they are marked with „Hot water“ or „Hard water“. For connection dimensions see fig. 3.1. Always
use the flexible hose delivered with the machine, if not present, contact your dealer. In each case do not
use a fixed connection to the water supply.
For the proper function of the machine, it is necessary to keep the water pressure within the limits stated in
the technical data. It is also necessary to connect all available water inlets to a water supply. If a hard water
supply is not present, connect it with soft water. If no hot water supply is present, contact your dealer for the
proper required action.
The machine is equipped with 3/4" inlet valves. First let the water flow from the tap into the drain before
connecting the machine to the water system. This is for cleaning the pipes from dirt. Otherwise the filters
could be stopped up.
Open the taps and check the connection points at the taps and at the inlets of the machine for tightness. If
water is leaking, correct the position of the seal and tighten the screw coupling.
WATER CONSUMPTION
The water consumption depends on the programmed values in the timer. These values are shown in the
program manual. For a prewash and wash the low water level (LL) is used. The high water level (HL) is
used for rinsing. The programmed units correspond to an average amount of water. You can calculate the
total water consumption in one washing program by counting up the amount of water by each washing step.
An example is shown for a system with cold and warm water supply for a machine with capacity of 95 liter.
A system without warm water supply you can count with the total amounts.
Program 60°C Light soiled linen
Consumption (liter) Cold water Warm water Total
1. Wash 60°C 15 16 31
2. Rinse (3x) 46 0 138
TOTAL 61 16 169
Tab 4.6.B. Water consumption
The values received from this calculation is only an estimation of the real water consumption. The deviation
depends on many circumstances. In the wash cycle for example there will be taken a mix of warm water
and cold water. The mix of the water depends on the temperature of both. The total amount of water
consumed depends also on the loading of the drum with linen and the turning of the drum.

16 INSTALLATION AND MAINTENANCE MANUAL PUB.DATE : 05/02 100646
WATER DRAIN CONNECTION
The machine is equipped with a drain valve of 75 mm (3”) diameter. The drain is situated on the rear of the
machine. The drain has to be connected to the waste channel. You can use the elbow, which is a part of the
delivery. Secure the elbow with a clamp.
THE WASTE CHANNEL MUST BE LOCATED LOWER THAN THE DRAIN PIPES BECAUSE THE WATER
DISCHARGES FROM THE MACHINES BY GRAVITY. DO NOT REDUCE THE DIAMETER OF THE
MACHINE DRAIN PIPES.
1.waste channel cover
2.drain elbow ∅75mm(3”)
3.clamp
4.waste channel
Without rubber feet :
X1 = 55 mm
With rubber feet :
X1 = 73 mm
X2 > 100 mm
X3 > 20mm
Fig. 4.6.A. Design of the waste channel
The main drainpipe must have the capacity to be able to handle the total output of all connected machines.
There must also be a hole every twenty meter in the drainpipe, fig. 4.6.B, pos 1 to assure the good working
of the drain. This allows air in the main drain and facilitates drainage of the water flow. Every time a
machine is coupled on the drainpipe, the diameter of the tube or the width of the waste channel must be
more. See, fig. 4.6.B, D1,D2,D3.
The recommended drain pipes diameter are:
D1 = 75 mm / 3” for one machine
D2 = 100 mm / 4” for two machines
D3 = 125 mm / 5” for three machines
If the main drain cannot be sufficiently deodorized, install a deodorizer per machine.
Fig. 4.6.B. Recommended drain pipe diameters

100 646 PUB.DATE : 05/02 INSTALLATION AND MAINTENANCE MANUAL 17
AIR VENT CONNECTION
WARNING!
WATCH OUT FOR STEAM ESCAPE FROM THE MACHINE VENTING !
DO NOT COVER THE MACHINE VENTING; IT SERVES AS A STEAM OUTLET AND MACHINE
VENTING. IT ALLOWS A PROPER MEASURING OF THE LEVEL..
On the backside, the machine is provided with a drum air vent terminal (see fig. 3.1 pos 4) of external
diameter 75 mm (3"). Do not cover it!
For the safety of everyone do one of the following things :
1. Make sure that no-one can reach the backside of the machine.
2. You can connect the machine-venting pipe to the laundry central duct for exhausting the steam out of the
building or to another room where it is safe to emit it. The piping material must withstand a temperature
of80°C / 176°F. You can attach a rubber elbow on the machine by using of a clamp. The central duct
formultiple venting must be dimensioned for the total cross section of venting pipes of all machines.
Acalibration of the machine’s “zero level “ must be made after the duct attachment.
3. You can also use a rubber pipe (elbow and a clamp) and emit the vapor in the waste channel.
WARNING!
BE SURE THAT THE END OF THE PIPE IS NOT IN THE WATER, OTHERWISE THERE WOULD BE AN
ACCUMULATION OF STEAM IN THE MACHINE. THIS CAN LEAD TO INJURY TO PEOPLE AND CAN
DAMAGE THE MACHINE!!
4.7. CONNECTION OF LIQUID WASHING SOAPS DOSING
It is possible to connect an external dosing of liquid soaps to the machine.
WARNING !
DISCONNECT THE MACHINE SUPPLY POWER INLET BEFORE INSTALLATION.
THE INLET TERMINALS ARE UNDER CURRENT EVEN WHEN THE MAIN SWITCH IS OFF
ELECTRICAL CONNECTION AND CONNECTING THE MACHINE INLETS MUST BE CARRIED OUT
BY AUTHORIZED WORKERS ACCORDING TO INSTALLATION MANUAL INSTRUCTIONS AND IN
ACCORDANCE WITH VALID LOCAL STANDARDS.
AFTER THE HOSES ARE CONNECTED PUT ALL MACHINE COVERS BACK TO THEIR PLACES.
For connecting the liquid soap inlets and wiring for machines 60l / 75l / 95l you must take of the top panel.
Unscrew the two bolts and take the top panel of the machine. For the 165l it is sufficient to open the top
panel by means of the two keyswitches at the front.
At the right side panel there is a support for the top panel.
The hoses of external dosing of liquid soaps are
pushed through the holes in the rear panel after
removing the plugs. The hoses should be protected
by
rubber bushings where penetrating the rear panel.
After
this make as many holes in the soap hopper,
fig. 4.7.A, pos 1) as you have liquid soap hoses.
Connect the hoses to the soap hopper by means
of clamps.
Fig. 4.7.A. Connection soap hopper
!
!
!

18 INSTALLATION AND MAINTENANCE MANUAL PUB.DATE : 05/02 100646
WARNING !
CHECK IF THE HOSES ARE TIGHTEN BY THE CLAMPS !
ANY LEAKAGE OF CHEMICALS MAY CAUSE CORROSION ON THE PARTS IN THE MACHINE.
The liquid soap pump system supply needs to be connected to an external electrical source. Only authorised
workers with a valid qualification must execute the electrical connection of the machine according to the valid
local standards. Do not connect the pump system in the machine. The liquid soap signals are available in
the machine on a connector, see fig. 4.7.B. The first terminal is the common line of the signals. The following
terminals are the signals that will be active depending of the programmed wash programme. These signals have
a potential of max. 250V. Use a cable that is sufficcient for their function and pass it in the appropriate opening
in the machine. Connect these signal terminals like the manufacturer of the liquid soap system requires. The
liquid soap system may draw maximum 0,1A out the control circuit of the washer-extractor.
1. terminals for connection
liquid soap pumps
2. Neutral line
3. Soap signals
Fig. 4.7.B. Electrical connection soap pumps
4.8. PREPARING THE MACHINE FOR OPERATION
CHECKING BEFORE PUTTING INTO SERVIC E
1. Make sure the transporting braces are removed.
2. Put out all things from wash drum.
3. Check the machine horizontal position.
4. Check connection and clearance of your drain, channel or central drainage.
5. Check protective connection (earthing) and electrical supply connection.
6. Open water valves to machine and check hose and connections for leaks.
7. Read carefully the „User manual“ and „Programming manual“, which are a part of delivery.
8. Initialize the programmer after machine installation. The calibration of the zero level must not happen
anymore. This calibration is executed in the factory and is not changeable.
9. Check the drum rotation direction during extracting according to the extracting label.
10. Check the vibration switch function during extracting (see also chapter 5.2 adjustments and parts
exchange, adjustment of the vibration switch.
11. Check the emergency function
!

100 646 PUB.DATE : 05/02 INSTALLATION AND MAINTENANCE MANUAL 19
5. MAINTENANCE AND ADJUSTMENTS
WARNING !
ALWAYS FOLLOW SAFETY INSTRUCTIONS! DO NOT BYPASS ANY SAFETY DEVICES OR THEIR
PARTS, ANY INTERFERENCE TO THE MACHINE FUNCTIONS AND CONSTRUCTION ARE
PROHIBITED. BEFORE MAINTENANCE WORK DISCONNECT THE MACHINE POWER SUPPLY.
In case of serious failures call the technical service of your supplier. When replacing any parts of the
machine, exchange them with original parts obtained from your dealer or ordered through the spare parts
catalogue.
5.1. MAINTENANCE
CHECKING AND MAINTENANCE DAILY
1. Remove the linen or other parts (paperclips, needles, …) who are left lying in the drum to avoid injuries
and damage to the rubber door seal, seals, glass etc.
2. Clean the door seal from any remaining detergent and other foreign matter.
3. Clean the top and body when water or detergent traces are on the machine. Use a damped cloth, do not
use abrasive cleaners. Dry with a soft cloth.
4. Hoppers must be cleaned at the end of each working day. Remove sediments inside the reservoir by
means of a plastic spatula and splash by water.
5. Check water and possible steam inlets for leakage.
6. At the end of the working day, open the machine door to allow airing out the machine and to prolong the
door gasket life service. We recommend to shut off all electrical power inlets and main water inlets.
CHECKING AND MAINTENANCE EVERY THREE MONTHS
WARNING !
HOT MACHINE PARTS SHOULD BE ALLOWED TO COOL FIRST !
1. Check if the drain valve is not leaking during the wash process.It is also important that the valve opens
properly afterwards (drain valve opens when electrical power falls out).Wash out the drain if the water
doesn’t drain fluent.
2. Check for the belt tightness or possible damage; therefore remove the machine rear cover.
3. Check the tightness of the bolts according to chapter 5.2.
4. Check visually all hoses and connection inside the machine for leaking.
5. Make sure that the control components are protected against moisture and dust during the clean up.Wipe
and clean up the machine inside.
6. Tighten the contacts of heating elements terminals on machines with electrical heating.
CHECKING AND MAINTENANCE EVERY SIX MONTHS
1. The filters in the water connection at the valves need to be cleaned. Turn off the tap. Unscrew the hoses
at the back of the appliance. Take out the filter at the center with pointed pliers, clean and re-insert.
When re-attaching the hoses, make sure that the seals are seated correctly. Check water inlets for leaks.
Tighten the connections or replace the seals of the inlet hose if necessary.
BEFORE REMOVING TOP OR BACK PANEL OF THE MACHINE, SWITCH POWER OFF AND WAIT
FOR AT LEAST 10 MINUTES. BEFORE STARTING INSPECTION OF FREQUENCY INVERTER,
CHECK FOR RESIDUAL VOLTAGE ACROSS MAIN CIRCUIT TERMINALS + AND -. THIS VOLTAGE
MUST BE BELOW 30VDC BEFORE YOU CAN ACCESS THE INVERTER FOR INSPECTION.
2. Clean and remove dirt and dust from:
– the cooling fin of the inverter
– the motor cooling fins
– the internal ventilator of the inverter (if present)
– the external ventilator (if present)
– the external air relieves of the machine
– check if ventilator in coolfins of inverter (if present) is functional
– check if external ventilator (if present) is functional
!
!
!
Other manuals for FS 6-16
1
Table of contents
Other Primus Washer manuals

Primus
Primus C 6 User manual

Primus
Primus MB90 Manual

Primus
Primus F22 User manual

Primus
Primus FS16 Original operating manual

Primus
Primus 6kg Manual

Primus
Primus PW 5 Manual

Primus
Primus FS 6-16 User manual

Primus
Primus R6 User manual

Primus
Primus F 22-55 User manual

Primus
Primus MKIIA-LC Installation manual