level 2 safety standards.
Please follow the manual to use the instrument, otherwise the protection function provided by the
instrument may be reduced or invalid.
Safety Operation Specification
Warning
In order to avoid possible electric shock or personal injury, please abide by the following specifica-
tion:
Before using the instrument, please read the “Safety Instructions” in advance. Use the instru-
ment in strict accordance with the provisions”; otherwise, the protection ability provided by the
instrument may be reduced or invalid.
Check the external shell firstly before using the instrument. Check whether there are any
cracks or defects on the plastic parts. Please carefully check the insulator near the input ter-
minal.
If the instrument is not working properly or damaged, please do not use.
Do not touch the electrified body with more than 30V true effective value AC, 42V AC peak or
60V DC.
The instrument shall be used according to the specified measurement category, voltage or
current rating.
When it shows low battery indication, please replace the battery in time in case of any meas-
urement error.
Please comply with local and national safety code. Wear personal protection equipment (such
as approved rubber gloves, masks and flame retardant clothes, etc.) to prevent being damaged
by electric shock and electric arc due to exposed hazardous live conductor.
The voltage applied between input terminals or between each terminal and earth point cannot
exceed the specified ratings of the instrument.
Measure a known voltage to determine whether the instrument works properly.
When measuring, correct input terminal, function shift and range shift must be used.
Do not use the instrument around explosive gas, steam or in wet environment.
Do not use damaged probe. Check whether the insulation layer of the probe is damaged,
whether there’s any exposed metal or sign of wear. Check the continuity of the probe.
When measuring, please connect the zero line or the ground line firstly, then connect the live
wire; but when disconnecting, please cut off the live wire firstly, then disconnect the zero line
and ground line.
When measuring, please put your fingers behind the finger protector of the probe.
Before opening the back cover of the instrument, please disconnect the probe with the meas-
ured object.