MT-1509
3-1/2 Auto Range Multimeter
User’s Manual
1st Edition, 2020
© 2020 Copyright by Prokit’s Industries Co., Ltd.
1
The Statement
In accordance with the international copyright law, without
permission and written consent, one shall not copy the contents of
this manual in any form (including storage and retrieval or translation
into languages of other countries or regions). The manual is subject
to change in future edition without prior notice.
Caution
“Caution” mark refers to the condition and operation which may
cause damage to the instrument or equipment.
It requires that you must be careful during the execution of the
operation. If you incorrectly perform the operation or do not follow the
procedure, it may damage the instrument or equipment. In the
circumstances that such conditions are not met or not fully
understood, please do not continue to perform any operation
indicated by the caution mark.
Warning
“Warning” mark indicates the condition and operation which may
cause danger to users.
It requires that you must pay attention during the execution of
this operation. If you incorrectly perform the operation or do not follow
the procedure, it may result in personal injury or casualties. In the
circumstances that such conditions are not met or not fully
understood, please do not continue to perform any operation
indicated by the warning mark.
Before using the instrument, please read this manual carefully
and pay attention to the relevant safety warning information.
Overview
The instrument is a portable Auto range digital multimeter. It has
stable performance, high precision, low power consumption, novel
structure, and is safe and reliable. It’s an ideal measuring instrument
for the majority of users.
The instrument can measure DC voltage, AC voltage, resistance
and connectivity; with non-contact voltage detection function, timely
remind the user to pay attention to operation safety, so it’s more safe
2
for the user to use.
This manual includes the relevant safety information, warning
notices and so on, please read the related contents carefully before
using the instrument, and strictly follow all warnings and precautions.
Safety Instructions
The instrument is designed and manufactured strictly in
accordance with the safety standard IEC61010 and in conformity with
double insulation, over-voltage standard 600V CAT III and pollution
level 2 safety standards.
Please follow the manual to use the instrument, otherwise the
protection function provided by the instrument may be reduced or
invalid. Safety Operation Specification
Warning
In order to avoid possible electric shock or personal injury,
please abide by the following specification:
Before using the instrument, please read the “Safety Instructions”
in advance. Use the instrument in strict accordance with the
provisions”, otherwise the protection ability provided by the
instrument may be reduced or invalid.
Check the external shell first, before using the instrument.
Check whether there are any cracks or defects on the plastic parts.
Please carefully check the insulator near the input terminal.
If the instrument is not working properly or damaged, please do
not use.
Do not touch the electrified body with more than 30V true effective
value AC, 42V AC peak or 60V DC.
The instrument shall be used according to the specified
measurement category, voltage or current rating.
When it shows low battery indication, please replace the battery in
time in case of any measurement error.
Please comply with local and national safety code. Wear personal
protection equipment (such as approved rubber gloves, masks
and flame retardant clothes, etc.) to prevent being damaged by
electric shock and electric arc due to exposed hazardous live
conductor.
The voltage applied between input terminals or between each
3
terminal and earth point cannot exceed the specified ratings of the
instrument.
Measure a known voltage to determine whether the instrument
works properly.
When measuring, correct input terminal, function shift and range
shift must be used.
Do not use the instrument around explosive gas, steam or in wet
environment.
Do not use damaged probe. Check whether the insulation layer of
the probe is damaged, whether there’s any exposed metal or sign
of wear. Check the continuity of the probe.
When measuring, please connect the zero line or the ground line
first, then connect the live wire; but when disconnecting, please
cut off the live wire first, then disconnect the zero line and ground
line.
When measuring, please keep your fingers behind the finger
protector of the probe.
Before opening the back cover of the instrument, please
disconnect the probe with the measured object.
Do not use the instrument in the environment of exceeding the
measurement category (CAT) rating of a single element with the
lowest rating among the instrument, probe or accessories.
4
Electrical Symbols
High voltage warning
AC (Alternating current)
DC (Direct current)
AC or DC
Warning, important safety signs
Ground
Equipment with double insulation or reinforced
insulation protection
Low battery
Conforms with European Union standard
It shows - do not discard this electrical/electronic
product into household garbage.
CAT II
CAT II measurement is applicable for testing and
measuring circuits connected to the supply point
(socket and similarities ) of a low voltage power supply.
CAT III
CAT III measurement is applicable for testing and
measuring circuits connecting to the distribution
section of building low voltage power supply.
CAT IV
CAT IV measurement is applicable for testing and
measuring circuits connecting to the power supply of
building low voltage power supply.
5
Instrument Familiarization
AC
1
2
3
4
5
6
78
①.Flash light
②.Non-contact voltage detector
③.Non-contact voltage level indicator
④.LCD Display
Hold/Light/NCV keys:
Turn on/off backlight, flash light and data hold
Press down data hold, and then press again to cancel data hold,
press and hold more than 2 seconds, open the backlight and lighting,
after about 15 seconds automatically shut down or repress and hold
more than 2 seconds to manually turn off
NCV key,press this key for non-contact voltage detection
⑤.Power on/off button and measurement key:press for power and
long press more than 2 seconds for power off, while power on,
6
press this button for measurement.
⑥.Red test lead
⑦.Black test lead
Method of Measurement
AC /DC Voltage and Resistance Measurement
1. Press the power key to turn on the meter。
2. The probe is parallel to the circuit to be tested ACV, DCV or
resistance. Instrument automatic identification of AC voltage, DC
voltage or resistance.
3. When measured resistance, resistance is less than about 50,
built-in buzzer alarm.
4. Read measured results from the display, while measuring DC
voltage, it will show the voltage polarity of tested point of red and
black test lead at the same time.
5. When finished measurement, press the power key and hold for 2
seconds to turn off the instrument.
Warning
To prevent possible electric shock, fire or personal injury, before
measuring the resistance, please disconnect the power supply of
the circuit under test firstly, and fully discharge all the high voltage
capacitors.
After completed with all the measurement operations, make sure
to disconnect the probe and the circuit under test.
Non-contact Voltage Detection
1. Turn on power
2. Press and hold the "NCV" button, and then place the item under
test near the instrument non-contact voltage sensing area (less
than 5mm) to sense AC voltage.
3. Non-contact voltage indicator light will light up, saying there is AC
voltage present.
7
General Specifications
Operation environment condition:
IEC/EN 61010-1 600V CAT III, pollution level 2
Altitude< 2000 m
Working temperature:
0~40℃(do not consider when it’s <80% RH, <10℃)
Storage temperature:
-10~60℃(<70% RH, remove the battery)
Temperature coefficient: 0.1accuracy /℃
Maximum voltage allowed between the measuring terminal and the
ground: 600V DC or AC RMS
Sampling rate: about 3 times/second.
Display: 3 1/2 bit LCD
Over range indication: LCD display will show “OL”.
Low battery indication:
when the battery voltage is lower than the normal working voltage,
“ ” will be displayed on the LCD display.
Input polarity indication: automatically display “”
Power requirement: 2x1.5V AAA batteries
Dimension: 128x61x25mm
Accuracy Specifications
The accuracy applies within one year after the calibration.
Reference condition: the environment temperature 18℃to 28℃, the
relative humidity is no more than 80.
DC Voltage
Range
Resolution
Accuracy
2V
0.001V
± (0.5% readings+3)
20V
0.01V
200V
0.1V
600V
1V
± (0.8% readings+5)
Sensitivity:The minimum DC voltage of 0.5V
Input impedance: 10MΩ
Maximum input voltage: 600V DC or AC RMS
8
AC Voltage
Range
Resolution
Accuracy
2V
0.001V
±(0.8 readings +3)
20V
0.01V
200V
0.1V
600V
1V
±(1.0% readings +5)
Sensitivity:The minimum 1V AC voltage
Input impedance: 10MΩ Maximum input: 600V DC or AC RMS.
Frequency range: 50Hz~60Hz; true RMS
Resistance
Range
Resolutio
n
Accuracy
2kΩ
0.001 kΩ
±(1.0% readings +3)
20kΩ
0.01 kΩ
200kΩ
0.1 kΩ
2MΩ
0.001MΩ
10MΩ
0.01 MΩ
±(1.2% readings +15)
Input protection: Maximum 600V DC or AC RMS.
Connectivity
Functio
n
Description
Testing environment
When the buzzer
sounds, the measured
resistance is less than
50.
Test current: 100A;
open circuit voltage: about
-1.8V.
Input protection: Maximum 600V DC or AC RMS.
Instrument Maintenance
This section provides the basic maintenance information, including
description of replacing fuse and batteries.
9
Do not try to repair the instrument unless you are an experienced
repair person and have associated calibration, performance test and
maintenance information.
Warning
To prevent possible electric shock, fire or personal injury:
When the housing is open, do not use the instrument to do any
measurement operation.
Remove the input signal before cleaning the instrument.
Specified replacement parts shall be used. Please ask the
qualified technicians to repair the instrument.
General Maintenance
Use a damp cloth and a small amount of detergent to clean the outer
casing of the instrument. Please do not use abrasive or chemical
solvents.
Replacing the Batteries
Warning
To prevent electric shock or personal injury caused by error
reading, when it displays “ ” on the screen, the batteries
should be replaced in a timely manner.
To ensure safety operation and product maintenance, when the
instrument will not be used for an extended period of time, please
remove the batteries to avoid any product damage caused by
battery leakage.
To avoid electric shock or personal injury, before opening the back
cover to replace batteries, the instrument should be shut down
and checked to ensure that the probe has already been
disconnected from the measuring circuit.
Please follow the following steps to replace the battery:
1. Turn off the power supply of the instrument.
2. Disconnect the probe from the circuit under test.
3. Loosen the screws fixing the back cover, remove the back cover.
4. Remove the old batteries, replace with new batteries.
5. Mount the back cover, tighten the screws.
© 2016 Prokit’s Industries Co., LTD. All rights reserved 2016001(C)
10
3-1/2 自動換檔自動量程電表使用手冊
1. 聲明
根據國際版權法,未經允許和書面同意,不得以任何形式(包括存儲和
檢索或翻譯為其他國家或地區語言)複製本說明書的任何內容。本說明
書在將來的版本中如有更改,恕不另行通知。
“小心”標誌表示會對儀錶或設備造成損壞的狀況和操作。
它要求在執行此操作時必須小心,如果不正確執行此操作或不遵循
此操作步驟,則可能導致儀錶或設備損壞。在不滿足這些條件或沒有完
全理解的情況下,請勿繼續執行小心標誌所指示的任何操作。
“警告”標誌表示會對使用者造成危險的狀況和操作。
它要求在執行此操作時必須注意,如果不正確執此行操作或不遵守
此操作步驟,則可能導致人身傷害或傷亡。在不滿足這些條件或沒有完
全理解的情況下,請勿繼續執行警告標誌所指示的任何操作。
使用儀錶前,請仔細閱讀說明書並注意有關安全警告資訊。
2. 概述
Pro’sKit MT- 1509 3-1/2 全自動電表是一款可隨身攜帶的智慧型數
字萬用表。它性能穩定,精度高,功耗低,結構新穎,安全可靠,是廣大用
戶的理想測量儀錶。
儀錶可以測量直流電壓、交流電壓、電阻及連通性等功能;還具有
非接觸電壓探測功能,及時提醒用戶注意操作安全,讓用戶使用更安全、
放心。
本說明書包括有關的安全資訊和警告提示等,使用儀錶前請仔細閱
讀有關內容,並嚴格遵守所有的警告和注意事項。
3. 安全注意事項
本儀錶嚴格遵循安全標準 IEC61010 進行設計和生產,符合雙重絕
11
緣、過電壓標準 600V CATIII 和污染等級 2的安全標準。
請遵循本說明書使用儀錶,否則儀錶所提供的保護功能可能會降低或無
效。
4. 安全操作規範
警告
為了避免可能的觸電或人身傷害,請切實遵守以下的規範:
使用儀錶前,請先閱讀“安全須知”。並嚴格按照規定使用儀錶,否
則儀錶所提供的保護能力可能會降低或無效。
使用儀錶前先檢查外殼,檢查是否存在裂紋或塑膠件缺損,仔細
檢查輸入端子附近的絕緣體。
若儀錶工作不正常或損壞,請勿使用。
禁止觸摸電壓超過 30V 真有效值交流電、42 V 交流電峰值或 60V
直流電的帶電帶體。
應按照指定的測量類別、電壓或電流額定值使用儀錶。
當顯示電池電量不足指示時請及時更換電池,以防測量錯誤。
請遵守當地和國家的安全規範。穿戴個人防護用品(經認可的橡
膠手套、面具和阻燃衣物等),以防危險帶電導體外露時遭受電擊
和電弧而受傷。
輸入端子間或每個端子與接地點之間施加的電壓不能超過儀錶規
定額定值。
測量一個已知電壓,以確定儀錶操作是否正常。
請勿在爆炸性氣體、蒸汽周圍或在潮濕環境中使用儀錶。
請勿使用已損壞的表筆。檢查表筆的絕緣層是否損壞,是否有外
露金屬或有磨損跡象。檢查表筆的通斷性。
測量時,請先連接零線或地線,再連接火線;斷開時,請先切斷
火線,再斷開零線和地線。
測量時,請將手指握在表筆護指裝置的後面。
打開儀錶後蓋之前,請先斷開表筆與被測量物件。
請勿在超出儀錶、表筆或附件中額定值最低的單個元件的測量類
別(CAT) 額定值的環境中使用儀錶。
12
5. 電氣符號
高壓警告
AC(交流電)
DC(直流電)
交流電或直流電
警告,重要安全標誌
接地
保險絲
設備由雙重絕緣或加強絕緣保護
電池電量不足
符合歐盟(European Union)標準
說明不得將此電氣/電子產品丟棄在家庭垃圾中。
CAT II
II 類測量適用於測試和測量與低電壓電源裝置的用
電點(插座和相似點)直接連接的電路
CAT III
III 類測量適用於測試和測量與建築物低電壓電源
裝置配電部分連接的電路
CAT IV
IV 類測量適用於測試和測量與建築物低電壓電源
裝置電源連接的電路
6. 儀錶說明
13
①照明燈
②非接觸電壓感應區
③非接觸電壓指示燈
④顯示屏
⑤按鍵: :背光、照明燈開及資料保持鍵
按一下,開啟資料保持,再按一下取消資料保持;
按下並保持大於 2秒,開啟背光和照明燈,約 15 秒後自動關
閉或再按下並保持大於 2秒手動關閉
:NCV 鍵,非接觸電壓檢測鍵
⑥電源開關鍵,按下開機或按下並保持大於 2秒關機
⑦紅色表筆
⑧黑色表筆
7. 測量方法
7.1 交直流電壓/電阻測量/連通性檢測
按下電源開關鍵,打開儀錶的電源。
將表筆並聯到待測電路、電源或電阻上。儀錶自動判別交流電壓、
直流電壓、電阻。
當測量電阻時,電阻小於約 50時,內置蜂鳴器發聲。
從顯示屏讀取測量結果。測量直流電壓時,顯示屏同時顯示紅黑表
筆測試點的電壓極性。
測量結束,按下電源開關鍵並保持 2秒,關閉儀錶電源。
不要輸入高於 600V 的電壓,顯示更高電壓值是可能的,但可能會有
損壞儀錶的危險。
測量高電壓時,要格外小心,以避免觸電。
在完成所有的測量操作後,要斷開表筆與被測電路的連接。
7.2 非接觸電壓檢測
按下電源開關鍵,打開儀錶的電源。
按下“NCV”鍵並保持,然後將儀錶非接觸電壓感應區靠近(小於 5mm)
交流電壓的火線。
儀錶非接觸電壓指示燈將點亮,同時有蜂鳴提示音,表示火線上有
交流電壓。
14
8. 通用技術指標
使用環境條件:
IEC/EN 61010-1 600V CAT III,污染等級 2
海拔高度 < 2000 m
工作環境溫濕度:0~40℃(<80% RH,<10℃時不考慮)
儲存環境溫濕度:-10~60℃(<70% RH, 取掉電池)
溫度係數:0.1準確度/℃
測量端和地之間允許的最大電壓:600V 直流或交流有效值
採樣速率:約 3次/秒。
顯示:3 1/2 位液晶顯示屏
超量程指示:液晶顯示器將顯示“OL ”。
電池低壓指示:當電池電壓低於正常工作電壓時,“ ”將顯示在液晶
顯示器上。
輸入極性指示:自動顯示 “ ”號
電源: 2x1.5V AAA 電池
外形尺寸:128x61x25mm
9. 準確度指標
準確度在校準後一年內適用。
基準條件:環境溫度 18℃至28℃、相對濕度不大於 80。
9.1 直流電壓
量程
解析度
準確度
2V
0.001V
±(0.5% 讀數 +3 字)
20V
0.01V
200V
0.1V
600V
1V
±(0.8% 讀數 +5 字)
靈敏度:最小 0.5V 直流電壓
輸入阻抗:10MΩ
最大輸入電壓:600V DC 或AC 有效值。
15
9.2 交流電壓
量程
解析度
準確度
2V
0.001V
±(0.8 讀數 +3 字)
20V
0.01V
200V
0.1V
600V
1V
±(1.0% 讀數 +5 字)
靈敏度:最小 1V 交流電壓
輸入阻抗:10MΩ 最大輸入電壓:600V DC 或AC 有效值。
頻率範圍:50Hz~60Hz ,真有效值回應。
9.3 電阻
量程
解析度
準確度
2kΩ
0.001 kΩ
±(1.0% 讀數 +3 字)
20kΩ
0.01 kΩ
200kΩ
0.1 kΩ
2MΩ
0.001MΩ
10MΩ
0.01 MΩ
±(1.2% 讀數 +15 字)
輸入保護:最大 600VDC 或AC 有效值。
9.4 蜂鳴通斷
功
能
說明
測試環境
當內置蜂鳴器發聲時,
被 測 電 阻 不 大 於 約
50。
測試電流:約 100A;
開路電壓:約-1.8V。
輸入保護:最大 600V DC 或AC 有效值。
10. 儀錶維護
本節提供基本的維護資料,包括更換保險管和更換電池的說明。
除非您是有經驗的維修人員且有相關的校準、性能測試以及維修資料,
否則不要嘗試去維修本儀錶
為了防止可能發生的觸電、火災或人身傷害:
在機殼打開時,請勿使用儀錶進行任測量操作。
清潔儀錶前先移除輸入信號。
應使用指定的替換零件。請經過認可的技術人員維修儀錶。
16
3-1/2 自动换档自动量程电表使用手册
1. 声明
根据国际版权法,未经允许和书面同意,不得以任何形式(包括存储和
检索或翻译为其它国家或地区语言)复制本说明书的任何内容。本说明
书在将来的版本中如有更改,恕不另行通知。
“小心”标志表示会对仪表或设备造成损坏的状况和操作。
它要求在执行此操作时必须小心,如果不正确执行此操作或不遵循
此操作步骤,则可能导致仪表或设备损坏。在不满足这些条件或没有完
全理解的情况下,请勿继续执行小心标志所指示的任何操作。
“警告”标志表示会对使用者造成危险的状况和操作。
它要求在执行此操作时必须注意,如果不正确执此行操作或不遵守
此操作步骤,则可能导致人身伤害或伤亡。在不满足这些条件或没有完
全理解的情况下,请勿继续执行警告标志所指示的任何操作。
使用仪表前,请仔细阅读说明书并注意有关安全警告信息。
2. 概述
Pro’sKit MT- 1509 3-1/2 全自动电表是一款可随身携带的智能型数
字万用表。它性能稳定,精度高,功耗低,结构新颖,安全可靠,是广大用
户的理想测量仪表。
仪表可以测量直流电压、交流电压、电阻及连通性等功能;还具有
非接触电压探测功能,及时提醒用户注意操作安全,让用户使用更安全、
放心。
本说明书包括有关的安全信息和警告提示等,使用仪表前请仔细阅
读有关内容,并严格遵守所有的警告和注意事项。
3. 安全注意事项
本仪表严格遵循安全标准 IEC61010 进行设计和生产,符合双重绝
17
缘、过电压标准 600V CATIII 和污染等级 2的安全标准。
请遵循本说明书使用仪表,否则仪表所提供的保护功能可能会降低或无
效。
4. 安全操作规范
警告
为了避免可能的触电或人身伤害,请切实遵守以下的规范:
使用仪表前,请先阅读“安全须知”。并严格按照规定使用仪表,否
则仪表所提供的保护能力可能会降低或无效。
使用仪表前先检查外壳,检查是否存在裂纹或塑料件缺损,仔细
检查输入端子附近的绝缘体。
若仪表工作不正常或损坏,请勿使用。
禁止触摸电压超过 30V 真有效值交流电、42 V 交流电峰值或 60V
直流电的带电带体。
应按照指定的测量类别、电压或电流额定值使用仪表。
当显示电池电量不足指示时请及时更换电池,以防测量错误。
请遵守当地和国家的安全规范。穿戴个人防护用品(经认可的橡
胶手套、面具和阻燃衣物等),以防危险带电导体外露时遭受电击
和电弧而受伤。
输入端子间或每个端子与接地点之间施加的电压不能超过仪表规
定额定值。
测量一个已知电压,以确定仪表操作是否正常。
请勿在爆炸性气体、蒸汽周围或在潮湿环境中使用仪表。
请勿使用已损坏的表笔。检查表笔的绝缘层是否损坏,是否有外
露金属或有磨损迹象。检查表笔的通断性。
测量时,请先连接零线或地线,再连接火线;断开时,请先切断
火线,再断开零线和地线。
测量时,请将手指握在表笔护指装置的后面。
打开仪表后盖之前,请先断开表笔与被测量物件。
请勿在超出仪表、表笔或附件中额定值最低的单个组件的测量类
别(CAT) 额定值的环境中使用仪表。
18
5. 电气符号
高压警告
AC(交流电)
DC(直流电)
交流电或直流电
警告,重要安全标志
接地
保险丝
设备由双重绝缘或加强绝缘保护
电池电量不足
符合欧盟(European Union)标准
说明不得将此电气/电子产品丢弃在家庭垃圾中。
CAT II
II 类测量适用于测试和测量与低电压电源装置的用
电点(插座和相似点)直接连接的电路
CAT III
III 类测量适用于测试和测量与建筑物低电压电源
装置配电部分连接的电路
CAT IV
IV 类测量适用于测试和测量与建筑物低电压电源
装置电源连接的电路
6. 仪表说明
19
①照明灯
②非接触电压感应区
③非接触电压指示灯
④显示屏
⑤按键: :背光、照明灯开及数据保持键
按一下,开启数据保持,再按一下取消数据保持;
按下并保持大于 2秒,开启背光和照明灯,约 15 秒后自动关
闭或再按下并保持大于 2秒手动关闭
:NCV 键,非接触电压检测键
⑥电源开关键,按下开机或按下并保持大于 2秒关机
⑦红色表笔
⑧黑色表笔
7. 测量方法
7.1 交直流电压/电阻测量/连通性检测
按下电源开关键,打开仪表的电源。
将表笔并联到待测电路、电源或电阻上。仪表自动判别交流电压、
直流电压、电阻。
当测量电阻时,电阻小于约 50时,内置蜂鸣器发声。
从显示屏读取测量结果。测量直流电压时,显示屏同时显示红黑表
笔测试点的电压极性。
测量结束,按下电源开关键并保持 2秒,关闭仪表电源。
不要输入高于 600V 的电压,显示更高电压值是可能的,但可能会有
损坏仪表的危险。
测量高电压时,要格外小心,以避免触电。
在完成所有的测量操作后,要断开表笔与被测电路的连接。
7.2 非接触电压检测
按下电源开关键,打开仪表的电源。
按下“NCV”键并保持,然后将仪表非接触电压感应区靠近(小于 5mm)
交流电压的火线。
仪表非接触电压指示灯将点亮,同时有蜂鸣提示音,表示火在线有
交流电压。

This manual suits for next models

1

Other Pro's Kit Multimeter manuals

Pro's Kit MT-1509 User manual

Pro's Kit

Pro's Kit MT-1509 User manual

Pro's Kit MT-1217 User manual

Pro's Kit

Pro's Kit MT-1217 User manual

Pro's Kit MT-5210 User manual

Pro's Kit

Pro's Kit MT-5210 User manual

Pro's Kit MT-1706 User manual

Pro's Kit

Pro's Kit MT-1706 User manual

Pro's Kit MT-1217 User manual

Pro's Kit

Pro's Kit MT-1217 User manual

Pro's Kit MT-1503 User manual

Pro's Kit

Pro's Kit MT-1503 User manual

Pro's Kit mt-1232 User manual

Pro's Kit

Pro's Kit mt-1232 User manual

Pro's Kit MT-2208 User manual

Pro's Kit

Pro's Kit MT-2208 User manual

Pro's Kit MT-1708 User manual

Pro's Kit

Pro's Kit MT-1708 User manual

Pro's Kit MT-7602 User manual

Pro's Kit

Pro's Kit MT-7602 User manual

Pro's Kit MT-2207 User manual

Pro's Kit

Pro's Kit MT-2207 User manual

Pro's Kit MT-2018 User manual

Pro's Kit

Pro's Kit MT-2018 User manual

Pro's Kit MT-1820 User manual

Pro's Kit

Pro's Kit MT-1820 User manual

Pro's Kit MT-2017N User manual

Pro's Kit

Pro's Kit MT-2017N User manual

Pro's Kit MT-3109 User manual

Pro's Kit

Pro's Kit MT-3109 User manual

Pro's Kit MT-1220 User manual

Pro's Kit

Pro's Kit MT-1220 User manual

Pro's Kit MT-2017 User manual

Pro's Kit

Pro's Kit MT-2017 User manual

Pro's Kit MT-1232 User manual

Pro's Kit

Pro's Kit MT-1232 User manual

Pro's Kit MT-1610 User manual

Pro's Kit

Pro's Kit MT-1610 User manual

Pro's Kit MT-2018 User manual

Pro's Kit

Pro's Kit MT-2018 User manual

Pro's Kit MT-1132 User manual

Pro's Kit

Pro's Kit MT-1132 User manual

Pro's Kit MT-1510 User manual

Pro's Kit

Pro's Kit MT-1510 User manual

Pro's Kit MT-1508 User manual

Pro's Kit

Pro's Kit MT-1508 User manual

Pro's Kit MT-1707 User manual

Pro's Kit

Pro's Kit MT-1707 User manual

Popular Multimeter manuals by other brands

Tenma 72-3540 manual

Tenma

Tenma 72-3540 manual

Tenma 72-7224 operating manual

Tenma

Tenma 72-7224 operating manual

Tektronix DMM4040 Safety and installation instructions

Tektronix

Tektronix DMM4040 Safety and installation instructions

Fluke 8508A Extended specifications

Fluke

Fluke 8508A Extended specifications

Unit UT131A user manual

Unit

Unit UT131A user manual

SATA 03022 user manual

SATA

SATA 03022 user manual

Sonel CMM-60 user manual

Sonel

Sonel CMM-60 user manual

Eproteca KPS KPS-MT720 instruction manual

Eproteca

Eproteca KPS KPS-MT720 instruction manual

Circuit-test DMR-6600 user manual

Circuit-test

Circuit-test DMR-6600 user manual

Vichy VC97 Operation manual

Vichy

Vichy VC97 Operation manual

Extech Instruments EX310 user guide

Extech Instruments

Extech Instruments EX310 user guide

Extech Instruments EX520 user guide

Extech Instruments

Extech Instruments EX520 user guide

Triplett 1401 instruction manual

Triplett

Triplett 1401 instruction manual

Velleman DVM345DI user manual

Velleman

Velleman DVM345DI user manual

Eurotron Mini MMX II instruction manual

Eurotron

Eurotron Mini MMX II instruction manual

ADCMT 7352A Operation manual

ADCMT

ADCMT 7352A Operation manual

SIGLENT SDM3000 Series quick start guide

SIGLENT

SIGLENT SDM3000 Series quick start guide

VOLTCRAFT VC-12A operating instructions

VOLTCRAFT

VOLTCRAFT VC-12A operating instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.