1. Scope and General
2 Safety instructions and regulations
2.1 Symbols explanation
2.2 Safety instructions
3 Technical Data/Specification and product information
3.1 Parameters Table
3.2 Product Information
4 Installation
5 Trouble shooting
6 Maintenance and Repair
7 Warranty commitment
8 Contact us
1
1
1
2
2
2
2
2
3
4
4
5
CONTENT

1 Scope and General
2 Safety instructions
For your safety and effective operation, please read the safety instructions thoroughly before using the products.
Safety Instructions should always be observed to prevent accident or risk during operating.
2.1 Symbols explanation
This manual is used to PEFS-PL series products only.
Version Date Remark Chapter
V1.0 2022-01-15 First Edition -
Risk of Electric Shock
The installation and operation can be operated by qualified people only
The product must not be disposed together with household waste
Read all documentations which accompanies with the product
Do not touch
Risk of Electric Shock, Do Not Remove Cover.
No User Serviceable Parts Inside.
Refer Service To Qualified Service Personnel
SYMBOLS DIRECTIONS NOTE
DANGER
CAUTION ‒ Hot surfaces ‒ To reduce the risk of burns ‒ Do not touch.
DANGER
Risk of electric shock from energy stored in capacitor, Do not remove
cover until ___ minutes after disconnecting all sources of supply.
If there is
capacitor
DANGER
WARNING
CAUTION
www.projoy-electric.com
PEFS-PL Series

2.2 Safety instructions Caution!
3 Technical Data
1) Only qualified people who can install and operate
2) Read all documentations which accompanies with the product
3) Must follow the National Wiring Rules and local standards related.
3.1 Parameters Table
www.projoy-electric.com
PEFS-PL Series
Type PEFS-PL80S-11 PEFS-PL80S-21 PEFS-PL120S-11 PEFS-PL120S-21
Number of PV Inputs 1 2 1 2
Number of Modules Recommend 1 2 2 4
Maximum Allowed Input Voltage80V80V120V120V
Maximum Allowed Input Current
Maximum Output Voltage80V160V120V240V
System Voltage
Control Compliance
Control Requirements
Ambient Operating Temperature
Protection Temperature
IP Level
Fire-proof Level
Humidity
PV Connectors
Design Life Span
Size 120*51.9*22.4mm 120*59*22.4mm 120*51.9*22.4mm 120*59*22.4mm
Weight
Cable Length, PV1+ Input120mm 120mm 1200mm 120mm
Cable Length, PV1- Input1200mm 1200mm 1200mm 2400mm
Cable Length, PV2+ Input / 1200mm / 2400mm
Cable Length, PV2- Input / 120mm / 120mm
Cable Length, Power Output650mm+650mm 1250mm+1250mm 1250mm+1250mm 2450mm+2450mm
Cable Length, 24Vdc Control Cable 650mm+650mm 1250mm+1250mm 1250mm+1250mm 2450mm+2450mm
Standard Comliance NEC2017/2020 (690.12); UL1741; UL3741; IEC/EN62109; IEC/EN61000
>IP68, NEMA 4X
15A / 20A
Flame retardant, UL94-V0
0%~90%
MC4 (Customized)
21.6V~26.4V at nomi. 27~36mA/unit
24VDC + 2 x 0.8mm2Cable
1000V/ 1500V
-30° C to +60° C
85° C
< 200g (Excluding Cables)
25 years

PEFS-PL Series
www.projoy-electric.com
1) Fire-retardant V-0/UV resistant materials used, high temperature resistance, corrosion resistance and security
impact resistance.
2) Clip installation design, simple and convenient
3) Long lifespan design for 25 years
4) Normal working temperature is at -30℃~+80℃
5)
6)
7)
8)
Auto off once the temperature in over 85℃.
The connection cable used is UL and TUV qualified.
24Vdc wiring control way makes it more reliable and stable
More than 200m control distance , which is suitable for C&I solar systems.
Normal installation of PEFS-PL series will be 1/2/4 PV panels VS 1 RSD unit. Typical wiring example below:
Connect the PV panel Positive (+) output connector to the RSD Positive (+) input connector.
Connect the PV panel Negative (-) output connector to the RSD Negative (-) input connector.
3.2 Product Information
4 Installation
Temperature Rise Trigger AC Supply Cut-Off Manual Operation
×
85°
Manual shutdown is initiated within less
than 0.1 second of operation by press-
ing the emergency pushbutton on the
Emergency Rapid Shutdown Switch.
The Emergency Switch can be conve-
niently located at ground level for
easy access or multiple switches can be
installed in different multi-level
building zones.
Automatic shutdown occurs if
the temperature sensor on
board of the RSD detects an
ambient temperature rise
above 85 ℃
Disconnection of the external AC
supply, by whatever means,
causes automatic remote
operation of the Emergency
Rapid Shutdown Switch and solar
panel shutdown.

www.projoy-electric.com
PEFS-PL Series
Control Box
Inverter
Grid
DC+
DC24V
AC
DC-
PEFS-PL
Notes:
1) The 24VDC power source can be supplied separately with UL certificate and should be class 2 (AC/DC or DC/DC type) with
fast shutdown function (<100ms).
2) Meanwhile, temperature degradation and voltage drop should considered when selecting the DC power source. PEFS-
PL80/120-11 type needs 0.8W minimum, PEFS-PL80/120-21 type needs 1.5W minimum. The control voltage is 21.6V minimum.
3) In-line fuse should be used to protect the 24Vdc cable
4) 24V cable size is 2*0.8mm2 recommended

120
51.9
22.4
3
120
51.9
22.4
3
PEFS-PL Series
www.projoy-electric.com
Installation Precautions:
1) Make sure cable wiring correctly
2) Make sure the MC4 connector of PV panel and RSD is the same brand or compatible
3) Make sure the installation environment is applicable

www.projoy-electric.com
1) Check if the 24V power supply works properly
2) Check the 24Vdc cable conencting well or not
3) Check if the installation temperature of power source is too high or not (< 50℃)
4) Check if the installation temperature of RSD is too high or not (< 80℃)
PEFS-PL Series
If RSD can not work properly, please follow the process bellow the check and resolve.
1. Beyond the warranty period;
2. No valid quality assurance card and product serial number;
3. Transportation damage;
4. Improper use, operation and modification;
5. Operating in an environment beyond the specified in this manual;
6. Any installation and use beyond the scope specified in relevant international standards;
7. Damage caused by abnormal natural disasters (earthquake, fire, flood, etc.).
Projoy Electric Co., Ltd.
Tell: +86-512-6878 6489
Web: https://en.projoy-electric.com/
Add: 2nd Floor, Building 3, No. 2266, Taiyang Road, Xiangcheng District, Suzhou
8 Contact us
7.2 Aftersales service
Please contact Projoy local distributors for after-sales service
1) Inappropriate use or installation, self-modification or improper maintenance, etc.:
2) Beyond the prescribed scope of use;
3) Earthquakes, fires, lightning strikes, abnormal voltages, other natural disasters and secondary disasters, etc.
4) Any lost caused by any inappropriate use out of the scope defined in this manual, Projoy will not take the responsibility
7.1 Warranty
Projoy PEFS Series Module Level Rapid Shutdown Device: Up to 25 years lifespan design, which commencing from 3 months
later of the manufacturing date. PROJOY will repair or replace any fault unit which is damaged or cannot work normally due to
product quality issue. However, for the faults caused by following reasons, PROJOY would do service with charge even under
warranty.
Other manuals for PEFS-PL Series
1
This manual suits for next models
4
Table of contents
Other Projoy Electric Inverter manuals
Popular Inverter manuals by other brands

Victron energy
Victron energy Phoenix 12/250 manual

Universal Motors
Universal Motors Goodrive 10 Operation manual

RedEarth
RedEarth BlackMax installation manual

Sensata
Sensata Dimensions 12LPC15 owner's manual

Generac Power Systems
Generac Power Systems 004810-0 owner's manual

Cru Power
Cru Power E-1000 manual