Thank you for purchasing a PROSCALE®LÜR™ digital scale. Please read all operating instructions careful-
ly before use. This electronic scale is a precision instrument.With normal care and proper treatment, it
will provide years of reliable service.
Never load the scale with more than the maximum capacity. Overloading will permanently damage it!
Avoiding any exposure to extreme heat or cold, your scale works better when operated at normal room
temperature. Always allow the scale to acclimate to normal room temperature for at least one hour
before use. Give your scale sucient warm up time. Usually 30-60 seconds to give the internal compo-
nents a chance to stabilize. Keep your scale in a clean environment. Dust, dirt, moisture, vibration, air
currents and a close distance to other electronic equipment can all cause an adverse eect on the
reliability and accuracy of your scale. Handle with care. Gently apply all items to be weighed onto tray
top. Although this scale is designed to be quite durable, try to avoid rough treatment as this may perma-
nently damage the internal sensor. Avoid shaking, dropping or otherwise shocking the scale. This is a
precision instrument and must be handled with extreme care.
TM
This document hosted by: www.oldwillknottscales.com
OPERATION
1. Place scale on a horizontal at surface, press [ON/ZERO]
key to turn on the scale.
2.Wait until "0.0" is displayed
3. Put the object(s) on the weighing platform
4. Using the [g/lb] key, you can change the weighing units.
TARE/ZERO
T
are can be used for eliminating the weight value of an
empty container. Place an empty container on the scale,
press [ ON/ZERO ].Then place the items to be weighed in the
container. NOTE: When all weight is removed from the
weighing tray, the tared value of a container will be
displayed as a negative number. Press [ON/ZERO] again to
return the scale to zero.
CLOCK/TIMER SETTING
1. General Settings
Please make sure that the scale is in clock mode.To toggle
through the modes (Clock, Alarm, Date) press [MODE].
Press [SET] when the scale is in clock mode to enter the
menu. Press [SET] again to toggle the settings till you
reach the desired mode. Press [MODE] to adjust the
selected digit. Press [SET] to conrm..
2. Setting the alarm & buzzer
Please make sure that the scale is in the clock mode. Press
[SET] to display the alarm time. Press [MODE] to toggle ON
and OFF the alarm and buzzer which are indicated by the
symbols ( ) and ( ) .
SPECIFICATIONS
Capacity 5000g
Readability 1g
Modes g/lb:oz
Tare Range Full capacity
Auto O 60 seconds
Op. Temp 15 to 30 degrees C
Display LCD 5 digits
Power 4 x AAA
Scale Dim. 207 x 175 x 20 mm
Tray 175 mm x 175 mm
DISPLAY ERROR MESSAGES
Change the batteries.
You are overloading the
scale. Remove the
excessive load immediately.
Use the scale in a more
stable position.
[O-LD]
[UnST]

Other Proscale Scale manuals

Proscale LCS100 User manual

Proscale

Proscale LCS100 User manual

Proscale PROFREIGHT 332 User manual

Proscale

Proscale PROFREIGHT 332 User manual

Proscale ProTouch IV User manual

Proscale

Proscale ProTouch IV User manual

Proscale SIMPLEX 300 User manual

Proscale

Proscale SIMPLEX 300 User manual

Proscale PRO-MOUSE 100 User manual

Proscale

Proscale PRO-MOUSE 100 User manual

Proscale SLICK User manual

Proscale

Proscale SLICK User manual

Proscale LC100 User manual

Proscale

Proscale LC100 User manual

Proscale Versa77 User manual

Proscale

Proscale Versa77 User manual

Proscale 111 User manual

Proscale

Proscale 111 User manual

Proscale LCS100 User manual

Proscale

Proscale LCS100 User manual

Proscale PX User manual

Proscale

Proscale PX User manual

Proscale 222 Instruction Manual

Proscale

Proscale 222 Instruction Manual

Popular Scale manuals by other brands

Soehnle KWD Pure Invite Operation

Soehnle

Soehnle KWD Pure Invite Operation

Anyload NPS Series Operator's guide

Anyload

Anyload NPS Series Operator's guide

HMM Diagnostics Smartlab scale user manual

HMM Diagnostics

HMM Diagnostics Smartlab scale user manual

Sartorius PMA35001-Y installation instructions

Sartorius

Sartorius PMA35001-Y installation instructions

Sencor SKS 5020WH-NA user manual

Sencor

Sencor SKS 5020WH-NA user manual

Tanita WB-800AS plus instruction manual

Tanita

Tanita WB-800AS plus instruction manual

Dr. Trust Absolute Grey user manual

Dr. Trust

Dr. Trust Absolute Grey user manual

bewell connect BW-SCF5 manual

bewell connect

bewell connect BW-SCF5 manual

Salter 1088 Instructions and guarantee

Salter

Salter 1088 Instructions and guarantee

Seca Robusta 813 bt Instructions for use

Seca

Seca Robusta 813 bt Instructions for use

TMT TCB Series Operational manual

TMT

TMT TCB Series Operational manual

nedis PESC500BK quick start guide

nedis

nedis PESC500BK quick start guide

ARESA AR-4301 instruction manual

ARESA

ARESA AR-4301 instruction manual

KERN EMS-BA-e-1514 instruction manual

KERN

KERN EMS-BA-e-1514 instruction manual

A&D HW-200KV-WP instruction manual

A&D

A&D HW-200KV-WP instruction manual

Tanita HD-361 Instructions for use

Tanita

Tanita HD-361 Instructions for use

IKEA RAAN manual

IKEA

IKEA RAAN manual

Vakoss WH-6305 manual

Vakoss

Vakoss WH-6305 manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.