Proxomed Compass 600 User manual

compass®600
User manual

2
1Foreword
Congratulations on your new device.
Compass®products bring real progress to your business and secure real benefits for both you and your
customers.
You have decided to purchase our training equipment. We thank you for this trust.
The equipment has undergone extensive safety and functional testing to reduce potential hazards and
risks. Please read these instructions for use with all safety instructions and warnings carefully before
using your training equipment for the first time to ensure a safe, effective and intended use for the
benefit of your customers and patients.
The compass®600 product line comprises eight training devices for strength and endurance training
and is specially designed for the use in rehabilitation and prevention facilities. The load dosage and
control for the training is done via a stack of plug-in weights.
The training devices are designed for patients with a maximum body weight of 200 kg and a maximum
body height of 200 cm. The equipment-specific use and operation are described in the respective
chapters of the equipment. The equipment must only be used under the instruction of a qualified trainer
who is familiar with the use of the equipment. The compass®600 training devices can be used to target
muscle groups of the upper or lower extremities and the trunk muscles.
All devices are manufactured in Germany and meet the highest demands due to their robust and stable
design. The devices are medical devices and meet the requirements of EN ISO 20957-1 and EN ISO
20957-2 class S/I.

3
Table of contents
1Foreword.................................................................................................................................... 2
2Notes on the instructions for use ............................................................................................ 6
2.1 Safety instructions (legend).......................................................................................................................................6
3Safety instructions .................................................................................................................... 7
3.1 Marking on the device.................................................................................................................................................7
3.2 Applied symbols for transport..................................................................................................................................8
3.3 Liability notice.................................................................................................................................................................8
3.4 Intended use....................................................................................................................................................................9
3.5 Indications and contraindications........................................................................................................................10
3.6 Patient population......................................................................................................................................................10
3.7 Clinical benefit .............................................................................................................................................................10
3.8 Responsible operation..............................................................................................................................................10
3.9 Safety regulations.......................................................................................................................................................11
3.10 Combination with other products........................................................................................................................11
3.11 Side effects and residual risks................................................................................................................................11
3.12 Incident reporting.......................................................................................................................................................11
4Storage, transport and installation ....................................................................................... 12
5Commissioning........................................................................................................................ 13
6Training tips............................................................................................................................. 14
7Device descriptions ................................................................................................................. 16
7.1 compass®600 Abductor/Adductor.....................................................................................................................16
Intended Purpose ............................................................................................................................................. 16
Indications ...........................................................................................................................................................16
Settings................................................................................................................................................................. 17
7.2 compass®600 Leg Extension/Leg Curl ..............................................................................................................18
Intended Purpose ............................................................................................................................................. 18
Indications ...........................................................................................................................................................18
Settings................................................................................................................................................................. 19
7.3 compass ® 600 Chest Press/Rowing....................................................................................................................21
Intended Purpose ............................................................................................................................................. 21
Indications ...........................................................................................................................................................21

4
Settings................................................................................................................................................................. 22
7.4 compass®600 Leg Press..........................................................................................................................................23
Intended Purpose ............................................................................................................................................. 23
Indications ...........................................................................................................................................................23
Settings................................................................................................................................................................. 24
7.5 compass®600 Butterfly/Butterfly Reverse .......................................................................................................26
Purpose.................................................................................................................................................................26
Indications ...........................................................................................................................................................26
Settings................................................................................................................................................................. 27
7.6 compass®600 Trunk Extension/Trunk Flexion ...............................................................................................29
Intended Purpose ............................................................................................................................................. 29
Indications ...........................................................................................................................................................29
Settings................................................................................................................................................................. 30
7.7 compass®600 Pulldown/Dip .................................................................................................................................31
Intended Purpose ............................................................................................................................................. 31
Indications ...........................................................................................................................................................31
Settings................................................................................................................................................................. 32
7.8 compass®600 Shoulder Press/Vertical Row....................................................................................................33
Intended Purpose ............................................................................................................................................. 33
Indications ...........................................................................................................................................................33
Settings................................................................................................................................................................. 34
7.9 General training settings .........................................................................................................................................35
8Maintenance, cleaning, servicing, disposal........................................................................... 37
9Service...................................................................................................................................... 39
10 Accessories............................................................................................................................... 40
11 Technical data.......................................................................................................................... 46
12 Warranty .................................................................................................................................. 48
13 Appendix.................................................................................................................................. 49
13.1 Real training weight...................................................................................................................................................49
Compass®600 Abductor/Adductor .......................................................................................................... 49
Compass®600 Leg Extension ......................................................................................................................49
Compass®600 Leg Curl ................................................................................................................................. 50

5
Compass®600 Chest Press........................................................................................................................... 50
Compass®600 Rowing...................................................................................................................................50
Compass®600 Leg Press ...............................................................................................................................51
Compass®600 Butterfly/Butterfly Reverse............................................................................................. 51
Compass®600 Pulldown/Dip ......................................................................................................................51
Compass®600 Shoulder Press/Vertical Rowing...................................................................................51
Compass®600 Trunk Extension.................................................................................................................. 52
Compass®600 Trunk Flexion.......................................................................................................................52

6
2Notes on the instructions for use
These instructions for use are part of the product and must be kept safe and accessible
throughout the entire service life. In the event of a change of ownership, the operating
instructions must be handed over to the new owner. If supplements to these operating
instructions are supplied, they must be added to the document.
2.1 Safety instructions (legend)
The safety instructions presented in the operating instructions are categorized as follows:
Safety note
Meaning
WARNING
WARNING
•Indicates a potentially dangerous situation.
•If the situation is not avoided, death or serious injury may
result.
CAUTION
CAUTION
•Indicates a potentially dangerous situation.
•If the situation is not avoided, an injury may result.
ATTENTION
ATTENTION
•Indicates a potentially harmful situation.
•If the situation is not avoided, the device may be
damaged.

7
3Safety instructions
3.1 Marking on the device
Figure
Description
Reference
Observe operating instructions
EN ISO 15223-1
Manufacturer, name, address, year of
manufacture
EN ISO 15223-1
123
CE Mark
EU 2017/ 745
Serial number
EN ISO 15223-1
Unique Device Identification
EU 2017/ 745
Multi-year inspection sticker
Next test date
(countersigned by perforation)
EN 62353
Type Shield
Identification of the manufacturer, address, year
of manufacture, device designation, serial
number, UDI number as well as device-specific
information
EU 2017/ 745
Follow instructions
Is additionally attached to devices with
electr. components
ISO 15223-1

8
3.2 Applied symbols for transport
Figure
Description
Reference
TOP - top here
-
DO NOT stack
-
Protect from moisture
-
Temperature range
ISO 15223-1
Humidity
ISO 15223-1
3.3 Liability notice
The device is built according to the current state of the art and the recognized safety rules. Nevertheless,
unauthorized misuse may result in hazards to persons and the device.
No design or development changes may be made to the device. The installation of additional
components or the removal of components is not permitted.
The device may only be used if it is in perfect technical condition and in the intended use described.

9
3.4 Intended use
The devices are manufactured according to the international standards EN ISO 20957-1 and EN ISO
20957-2 as class S (studio); they are intended for commercial use e.g. in health-oriented fitness facilities
or physiotherapy practices for use on patients.
Before the start of the first training session, the patient is instructed by qualified personnel.
Training with patients may only be performed under therapeutic supervision.
The device may only be used by adults (14 years and older); unsupervised children must be kept away
from the device.
The application is done in a sitting position.
The application is made only with intact skin.
If you feel unwell or have sudden symptoms, please stop training immediately and consult a doctor if
necessary.
To avoid injury, the patients should wear tight-fitting clothing; tie up open, long hair if necessary.
Compass® devices are intended for indoor use only.
When using the devices with the smart assist option outside the German-speaking area, English
language skills are required for operation.
In case of deviations from the intended use, the manufacturer is not liable for damages.
CAUTION
Before starting their first workout, beginners and returning users over the age of 45,
as well as people with existing illnesses and health problems, should consult a doctor.

10
3.5 Indications and contraindications
The indications for the use of the devices in therapy are shown in chapter 7 for the respective devices.
The devices are contraindicated and must not be used for the conditions listed below:
•Febrile diseases
•Current pain at rest or during activity, as well as acute health complaints
•Existing pain in the musculoskeletal system among other things after stretches, strains, torn
muscle fibers, sprains and disc protrusions
•Fresh fractures
•Osteoporosis in continued stages (grade 2 and 3)
•Hypertension in continued stages (grade 2 and 3 according to WHO)
•Artificial joint replacement at the knee and/or hip joint with unstable anchorage
•Severe neurological diseases with a tendency to muscle spasms
•Abdominal wall or inguinal hernia
•Pregnancy from the 2nd trimester
•Heart failure and coronary heart disease. Patients with high blood pressure may only use the
device after consultation with their physician.
3.6 Patient population
The devices are intended for professional use in health care facilities such as orthopedic and
physiotherapy departments in hospitals, rehabilitation clinics, etc. Depending on the indication, health
condition of the patient and treatment goal, the devices can be used in any phase of rehabilitation.
3.7 Clinical benefit
Compass®600 devices support physiotherapeutic interventions. The clinical benefit for the patient lies
in the complementary use of the devices and the resulting improved muscle stabilization.
3.8 Responsible operation
These operating instructions are intended for the operator and the qualified personnel. All people who
work on the device must be trained in its use and must have read and understood the operating
instructions including the safety chapter.
Personnel must be informed before therapy begins and at regular intervals about the nature and scope
of activities and about possible hazards such as any warnings.
Instruction on the equipment (therapist, trainer, fitness trainer) and monitoring (therapist, sports
therapist, fitness trainer) may only be carried out by trained personnel. Authorization of the operator is
required.
Adjustments must not be operated under load. Before each adjustment, make sure that there is no load
from a lifted weight block. This may impair the permanent functionality of the components.

11
3.9 Safety regulations
The device may only be used in technically perfect condition in the intended use. In the event of defects
or malfunctions, please block the device and contact the manufacturer's service department.
It must be ensured, especially when changing the position of the unit without disassembly, that the unit
stands securely on level ground.
The protective cladding must not be removed. The device may only be operated with the protective
cladding mounted.
The warranty becomes void if modifications are made to the device or electronic devices for control and
measurement are attached that have not been carried out by specialist personnel authorized by the
manufacturer.
Defective parts of the device must be replaced immediately - in this case, it is advisable to stop using
the device until repairs have been made. Only use original accessories, otherwise no liability will be
accepted.
The device may only be opened by proxomed service or authorized personnel.
Do not reach with your hands between the moving bearings/rollers.
3.10 Combination with other products
Compass®600 devices can optionally be used with the smart assist accessory. smart assist is an active
medical device from proxomed Medizintechnik GmbH that contains software. smart assist was
developed and tested according to EN 60601-1.
3.11 Side effects and residual risks
The devices are developed in such a way that no critical side effects occur. Occasional side effects such
as muscle soreness and joint pain may occur, usually after incorrect ergonomic adjustment or after too
intensive training. These symptoms should subside spontaneously after a few days.
3.12 Incident reporting
Please report any clinical events that occurred in and immediately after the use of the device directly to
the manufacturer at the address: vigilance@proxomed.com.

12
4Storage, transport and installation
Store the devices dry, free of seawater and protected from dust within the temperature range of -5°C to
+45°C.
Protect the devices from impacts, scratches and moisture. Note that the load-bearing capacity of the
substrate must be according to the weight of the devices.
Use the devices only in dry rooms free of seawater air (<65% humidity).
The devices are usually delivered completely assembled. In rare cases, it may be necessary to ship the
units partially disassembled for transport reasons. In these cases, please use the corresponding assembly
instructions and follow the instructions given!
When setting up the unit for the first time, it is important to know the maximum achievable range of
motion for the particular version to be installed. The clearance area around the unit must be at least 60
cm to ensure safe access and exit from the unit, also in emergencies. However, the safety clearances may
overlap.
The following Figure 1 shows an exemplary arrangement of compass®600 devices.
The device must be set up on a level, impact-resistant surface that can withstand the load of the device
and the maximum permissible body weight of the user of 200 kg.
To compensate for unevenness, the unit has adjustable feet that can be adjusted in height. An important
prerequisite for proper functioning of the device is alignment with a spirit level.
Avoid installing the equipment in heavily frequented rooms or near doors and passageways.
Figure 1
Area until
next device
Active
Training area

13
5Commissioning
Before each start-up, check that the training device is in perfect technical condition.
Locking bolt on function, the locking button must engage automatically.
Protective cladding - present or damaged.
Screw connections - check for tight connection.
Welded joints - visual inspection.
Movement limitation, if available as an option.
Accessories available/functional.
Check for safe stand.
Make sure that aids, accessories, cables, etc. are not within the range of motion.
ATTENTION
Before initial start-up, the devices should stand at room temperature for at least 24
hours.
CAUTION
Before starting training, check the detent pins for tightness.
Do not pull on the locking bolts and pins during training.

14
6Training tips
The device must be adjusted to the ergonomic conditions of the user before the first training. The
adjustment of the training device for the user is the responsibility of the qualified personnel.
•To avoid injuries and to make the training more effective, a general and special warm-up
program should be completed. This prepares the circulation and musculature for the loads.
•Select a safe and firm sitting position, with the pelvis and spine close to the seat. The back,
especially the lumbar spine, must be stabilized as best as possible during the exercise. If
available, the backrest is used to stabilize the spine. To support the spinal posture, especially for
people with postural instabilities, use the optional lordosis cushion.
•Correct positioning of the patient in the starting position contributes greatly to the quality,
effectiveness and safety of the exercise performance. The device axes and pivot points must be
matched as closely as possible to the axes of movement of the joints to be exercised in order to
avoid the occurrence of compression and shear forces.
•Perform the movement slowly and in a controlled manner.
•The intensity of the load should be selected to be light at the beginning of the training. The load
is gradually increased to avoid overload and discomfort.
•The equipment allows for double-leg or single-leg or double-arm or single-arm training.
•If mobility is restricted or pain occurs, immediately reduce the load or/and the extent of
movement.
•Training and therapy take place only in the pain-free area.
•During fast-impact exercises, the weight can be moved explosively. Controlled movement must
be ensured, especially in this training method, so that incorrect loads and injuries are avoided.
As a rule, concentric and eccentric ways of working the muscles are combined.
CAUTION
Improper or excessive training can lead to health problems
CAUTION
Pressurized breathing and the associated increase in intrathoracic pressure
can lead to damage to the vascular system in persons at risk. Perform
movement slowly and in a controlled manner.
WARNING
If you experience symptoms such as rapid heartbeat, dizziness, shortness of
breath, nausea or chest pain, profuse sweating or headache, please stop training
immediately.

15
•Different training methods are used. If training is done according to the repetition method,
several series of exercises are performed with appropriate breaks.
•The load intensity is based on the load capacity of the individual indications, the rehabilitation
phase and the treatment goal. Thus, in order to adapt and accustom the injured structure
(connective tissue, cartilage, tendons, ligaments and joint capsule) to a weight load, the focus
can be on low training intensity before the training of special strength skills - such as strength
endurance or maximum strength - begins with increasing intensity.
•In order to be able to reproduce the training positions made by a therapist/trainer during a later,
possibly independent training, all adjustment devices are provided with scales and numbered
alphabetically (A, B, C, ...).
•On all devices there is the possibility to stabilize the patient/client optimally during the training.
WARNING
Risk of injury. Keep a safety distance of at least 60 centimeters from moving parts.

16
7Device descriptions
7.1 compass®600 Abductor/Adductor
Intended Purpose
Compass®600 Abductor/Adductor is intended for muscular stabilization of the abducting or adducting
leg muscles.
Abduction
Adduction
Indications
•Sarcopenia of the leg muscles
•Nonspecific lower back pain
•Postoperative rehabilitation after hip arthroplasty
C - Footrests
A - Start angle
B - Backrest
Weight tower

17
Settings
A - Start angle/Leg supports
130°
11 à 13°
B - Backrest
75°
(80-5°)
Stepless
(8 positions)
C - Footrests right/left
optional
30 cm
16 à 2 cm

18
7.2 compass®600 Leg Extension/Leg Curl
Intended Purpose
Compass® 600 Leg Extension/Leg Curl is intended for muscular stabilization of the leg extension or leg
curl muscles.
Leg Extension
Leg Curl
Indications
•Sarcopenia of the leg muscles
•Osteoporosis (grade 0 and 1)
•Postoperative rehabilitation after hip arthroplasty
Femoral fixation
A - Seat
C - Start angle
B - Legrest
Leg rest
Weight tower

19
Settings
A - Seat depth
21 cm
(45-66 cm)
Stepless
(12 positions)
B - Legrest
26 cm
(19-45 cm)
Stepless
(25 positions)
C - Start angle
105°
(10-85°)
12 à 10°

20
Leg fixation
105°
(10-85°)
6 à 10°
Other manuals for Compass 600
1
Table of contents
Other Proxomed Fitness Equipment manuals

Proxomed
Proxomed kardiomed 521 User manual

Proxomed
Proxomed compass MTT User manual

Proxomed
Proxomed Compass 530 User manual

Proxomed
Proxomed Intensic Abductor User manual

Proxomed
Proxomed kardiomed 521 User manual

Proxomed
Proxomed Core Circuit User manual

Proxomed
Proxomed tergumed 710 User manual

Proxomed
Proxomed compass 210 Abductor User manual

Proxomed
Proxomed kardiomed 530 cycle User manual

Proxomed
Proxomed Kardiomed LC Operation instructions