1
Desktop type switch mode power supplies
PSD12006, PSD12010, PSD12020, PSD12030,
PSD12050, PSD12070, PSD12100
EN
Edition: 1st from 09.07.2010
Supercedes edition:_ _ _ _ _
1. echnical description.
1.1. General description.
Stabilised DC power supply is intended for cameras installed in CC V industrial systems. he unit has a cable
with a DC5.5/2.1 pin. When connected to fuse blocks of the LB4/xx/xx or LB8/xx/xx family, the power supply unit can feed
more cameras (max. 4 or 8). he unit is protected against short-circuit and overload.
1.2. echnical parameters.
REMARKS:
(1) – detachable DC cable, power supply is sell with a AC cable (EV 1,2m, code PSD12)
(2) – power supply has build in PFC circuit
(3) – fastening clips to a wall
* - output current of the power supply unit depending on ambient temperature. For temperature above
30°C maximum output current is limited according to graph 1. he power supply operation life time is
limited by reliability of the electrolyte capacitors which strongly depends of an operation temperature.
Avoid excessive temperature rise of the power supply!
PSD
12006
PSD
12010
PSD
12020
PSD
12030
PSD
12050
PSD
12070
PSD
12100
Dimensions
(L x W (W1) x H)
65x36(56)
x30
65x36(56)
x30
86x50(72)
x32
107x47(82)
x33
112x52(81)
x35
116x56(84)
x37
175x72(101)
x45
Net/Gross weight
130g/155g 130g/155g 205g/235g 250g/280g 300g/340g 350g/395g 650g/710g
DC plug DC5,5/2,1 female
AC cable length 115cm 115cm 115cm 115cm 145cm 145cm 145cm
DC cable length 145cm 145cm 145 cm 145cm 115cm 125cm 150cm
AC supply
100 V÷ 240 V AC 50/60 Hz
Maximum AC
variation 90 V÷ 264 V AC 50/60 Hz
Output power*
7,2W* 12W* 24W* 36W* 60W* 84W* 120W*
Output voltage 12 V DC
Maximum output
current
for t
AMB
<30°C
0,6A* 1A* 2A* 3A* 5A* 7A* 10A*
Maximum output
current
for t
AMB
=40°C
0,4A* 0,7A* 1,4A* 2,1A* 3,5A* 4,9A* 7A*
Output ripple <120mV
Short circuit
protection /
Overload protection
Yes
Operation status
indication
Yes – LED diode
Operation condition 0 ÷ 40
o
C , RH 10 ÷ 90 %, no condensation
Remarks (3) (3) (3) (3) (3) (1), (3) (1), (2), (3)
2
Graph 1 Relation between output power and ambient temperature.
Figure 1 Dimensions of the power supply.
1.3. Accessories.
Fallowing accessories are available for desktop power supplies:
- fuse blocks LB4/xx/xx (AWZ573, AWZ574, AWZ575, AWZ576)
Fuse block is intended for connect multiple loads to one power supply unit. Fuse block has four, independently
protected outputs. Each output is protected against: overvoltage (varistor) and short circuit / overload. Depends
of type of the fuse block, overload / short circuit protection is realized with fuse or resettable P C fuse.
AWZ573
LB4/0,3A/P C
AWZ574
LB4/0,5A/P C
AWZ575
LB4/1,0A/P C
AWZ576
LB4/0,3-1,0A/F A
Protections:
- short circuit SCP
- overload OLP
- 4 x 0,3A P C
- 4 x 0,5A P C
- 4 x 1,0A P C
- 4 x F 0,3A or
- 4 x F 0,5A or
- 4 x F 1,0A
- fuse blocks LB8/xx/xx (AWZ577, AWZ578, AWZ579, AWZ580)
LB8/xx/xx module is similar to LB4/xx/xx with one exception: LB8/xx/xx has eight outputs.
AWZ577
LB8/0,3A/P C
AWZ578
LB8/0,5A/P C
AWZ579
LB8/1,0A/P C
AWZ580
LB8/0,3-1,0A/F A
Protections:
- short circuit SCP
- overload OLP
- 8 x 0,3A P C
- 8 x 0,5A P C
- 8 x 1,0A P C
- 4 x F 0,3A or
- 4 x F 0,5A or
- 4 x F 1,0A
3
- adapter CABLE – DC 5,5/2,1 PLUG (code ML109)
2. Installation.
2.1 Requirements.
he desktop power supply shall be mounted by the qualified installer having appropriate (required and necessary
for a given country) permissions and qualifications for connecting (operating) low-voltage installations. he unit shall be
mounted in closed rooms, according to the environment class II, of the normal air humidity (RH=90% max. without
condensation) and the temperature within the range from 0°C to +40°C.
he power supply shall be mounted in a close casing (a cubicle, a terminal device) and in order to fulfill LVD and
EMC requirements the rules for power-supply, encasing and shielding shall be observed according to application.
2.2 Installation procedure.
1. Connect the DC output to the load/loads.
2. Connect the power supply unit to the AC line. he power supply has to by installed in such way to keep air flow around
the power supply unit.
3. After tests and operation control are performed, the casing (cubicle) shall be closed etc.
3. Maintenance.
All the maintenance duties may be performed following disconnection of the power pack from the power grid. he
power pack does not require any specific maintenance procedures, however, in the case of significant level of dust, its
interior should be cleaned with the compressed air.
4
WEEE designation
The waste electric and electronic equipment worn out may not be disposed of together
with standard household waste. According to the WEEE directive, applicable in the EU,
the separate neutralization methods should be used for electric and electronic
equipment.
Pulsar K.Bogusz Sp.j.
Siedlec 150, 32-744 Łapczyca, Poland
el. (+48) 14-610-19-40, Fax. (+48) 14-610-19-50
e-mail: [email protected], sa[email protected]l
http:// www.pulsar.pl
THE GENERAL WARRANTY CONDITIONS
1. Pulsar K. Bogusz, Particular Partnership (the manufacturer) provides a one-year quality arranty for devices, as from the purchase date placed on a purchase
proof.
2. The arranty includes free repair or replace for a functional equivalent (the selection is performed by the manufacturer) of a non-operational device due to
reasons dependent on the manufacturer, including production and material defects, as far as defects are notified ithin the arranty period (item 1 and 2).
3. The equipment subject to arranty shall be provided to the point, here it has been purchased or directly to the place of business.
4. The complete devices are subject to arranty, and the sort of defect shall be described in ritten in a correctly fulfilled claim notification.
5. If a claim is accepted, the manufacturer is obliged to perform arranty repairs as soon as possible, but no later than 14 orking days since the device is
provided to the service of the manufacturer.
6. The repair period specified in item 5 can be extended, if there are no technical opportunities to perform the repair or the equipment is conditionally accepted
by the service due to non-compliance of the arranty conditions by the person lodging a claim.
7. All service actions related to arranty are performed exclusively at the service of the manufacturer.
8. The arranty does not include the follo ing defects of the device due to:
- manufacturer-independent reasons,
- mechanical defects,
- improper storage and transport,
- operation contrary to the instruction manual or purpose of the device,
- emergencies, including atmospheric discharges, failures of the po er net ork, fire, flood, effect of high temperature and chemical agents,
- improper installation and configuration (contrary to the instruction manual)
9. The loss of rights resulting from the arranty al ays occurs, if it is confirmed that construction changes have been performed or repairs have not been
performed at the service of the manufacturer, or if serial numbers or arranty labels of the device are someho replaced or damaged.
10. The responsibility of the manufacturer to ards the purchaser is limited to the value of the device determined according to the holesale price from the
purchase day suggested by the manufacturer.
11. The manufacturer does not bear any responsibility for damages resulting from failure, faulty operation or inability to use the device, particularly if it results
from non-compliance ith advices and requirements included in the instruction manual or contrary to purpose of the device.

This manual suits for next models

6

Other Pulsar Power Supply manuals

Pulsar PSC13008 User manual

Pulsar

Pulsar PSC13008 User manual

Pulsar PSBS 1024B User manual

Pulsar

Pulsar PSBS 1024B User manual

Pulsar PSBOC502418 User manual

Pulsar

Pulsar PSBOC502418 User manual

Pulsar AWZ 101 User manual

Pulsar

Pulsar AWZ 101 User manual

Pulsar PSP54006 User manual

Pulsar

Pulsar PSP54006 User manual

Pulsar EN54-5A40LCD User manual

Pulsar

Pulsar EN54-5A40LCD User manual

Pulsar PSBS 5012D User manual

Pulsar

Pulsar PSBS 5012D User manual

Pulsar POE042418B User manual

Pulsar

Pulsar POE042418B User manual

Pulsar PS-602425 User manual

Pulsar

Pulsar PS-602425 User manual

Pulsar GREEN POWER HPSB 1512B User manual

Pulsar

Pulsar GREEN POWER HPSB 1512B User manual

Pulsar PS-12V15A User manual

Pulsar

Pulsar PS-12V15A User manual

Pulsar ROUPS12VR User manual

Pulsar

Pulsar ROUPS12VR User manual

Pulsar EN54C Series User manual

Pulsar

Pulsar EN54C Series User manual

Pulsar PSD480075 User manual

Pulsar

Pulsar PSD480075 User manual

Pulsar PSD480250 User manual

Pulsar

Pulsar PSD480250 User manual

Pulsar PSBBH 1012 User manual

Pulsar

Pulsar PSBBH 1012 User manual

Pulsar PS20012140 User manual

Pulsar

Pulsar PS20012140 User manual

Pulsar BLACK POWER PSBEN 2012C User manual

Pulsar

Pulsar BLACK POWER PSBEN 2012C User manual

Pulsar HPSB 11A12C User manual

Pulsar

Pulsar HPSB 11A12C User manual

Pulsar HPSBB 0324 27.6V/3A/2x7Ah User manual

Pulsar

Pulsar HPSBB 0324 27.6V/3A/2x7Ah User manual

Pulsar PSD15040 User manual

Pulsar

Pulsar PSD15040 User manual

Pulsar PSBOC352413 User manual

Pulsar

Pulsar PSBOC352413 User manual

Pulsar HPSB 2512C User manual

Pulsar

Pulsar HPSB 2512C User manual

Pulsar PSBEN 2012B/LCD User manual

Pulsar

Pulsar PSBEN 2012B/LCD User manual

Popular Power Supply manuals by other brands

Bogen SPS2466 Installation

Bogen

Bogen SPS2466 Installation

Vimar ELVOX 6942 Installer's guide

Vimar

Vimar ELVOX 6942 Installer's guide

Haltian Thingsee POWERCOVER User and installation guide

Haltian

Haltian Thingsee POWERCOVER User and installation guide

Seneca Z109S-1 manual

Seneca

Seneca Z109S-1 manual

Eisco ESRDS1337 instruction manual

Eisco

Eisco ESRDS1337 instruction manual

Elektro-Automatik EA-ELR 10000 3U manual

Elektro-Automatik

Elektro-Automatik EA-ELR 10000 3U manual

NETGEAR ProSafe APS1000W installation guide

NETGEAR

NETGEAR ProSafe APS1000W installation guide

axing TZU 11-02 Operation instructions

axing

axing TZU 11-02 Operation instructions

ENERMAX REVOLUTION85PLUS user manual

ENERMAX

ENERMAX REVOLUTION85PLUS user manual

Conrad PSW160-7.2 operating instructions

Conrad

Conrad PSW160-7.2 operating instructions

Puls CP10.241-S2 installation manual

Puls

Puls CP10.241-S2 installation manual

Intelight PRIMUS LED operating instructions

Intelight

Intelight PRIMUS LED operating instructions

Vanderbilt PSU241038 quick start guide

Vanderbilt

Vanderbilt PSU241038 quick start guide

Samlex Europe SEC-1212G owner's manual

Samlex Europe

Samlex Europe SEC-1212G owner's manual

LEYBOLD 666 471 instruction sheet

LEYBOLD

LEYBOLD 666 471 instruction sheet

Horizont ranger AN3000 instruction manual

Horizont

Horizont ranger AN3000 instruction manual

ODA EX Series user manual

ODA

ODA EX Series user manual

Akyga AK-ND-09 user manual

Akyga

Akyga AK-ND-09 user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.