Purified Air UV-O 500 User manual

UV-O Odour Control Units
Technical and
Operations Manual
Models Covered: UV-O 500
UV-O 1000


UV-O Odour Control Units
Technical and Operations Manual - Using this Manual i
Using this Manual
This manual is intended to be used as a work of reference by professional, well trained and
authorised users to assist them in safely installing, using, maintaining and repairing the Units
mentioned on the cover of this document.
Please note that it is strongly recommended that training is given by Puried Air Limited prior to
operatives attempting to carry out maintenance or repair work on these Units.

UV-O Odour Control Units
ii Technical and Operations Manual - Copyright Statement
Copyright Statement
All rights reserved
No part of this publication may be copied or published by means of printing, photocopying,
microlm or otherwise without prior written consent othe manuacturer. This restriction also
applies to the corresponding drawings and diagrams.
The information given in this manual has been collected for the general convenience of our clients.
It has been based on general data pertaining to construction material properties and working
methods known to us at the time of issue of the document and is therefore subject, at any time,
to change or amendment and the right to change or amend is hereby expressly reserved. The
instructions in this publication only serve as a guideline for installation, use, maintenance and
repair of the models mentioned on the cover page of this document.
This manual is to be used for the standard models of the Units of the type given on the cover page.
Thus the manufacturer cannot be held responsible for any damage resulting from the application of
this manual to the version actually delivered to you.
This manual has been written with great care. However, the manufacturer cannot be held
responsible either for any errors occurring in this manual or their consequences.


Technical and Operations Manual - Safety 1
UV-O Odour Control Units
1. Safety
1.1 Introduction
Everyone working on or with these Units must be familiar with the contents of this manual
and must strictly observe the instructions herein.
The Management should instruct personnel in accordance with this manual and observe
all instructions and directions given herein.
Note: Always ollow the steps or any instructions in this manual in the order given.
Always keep this manual with your Unit.
The users of the Units are always fully responsible for observing all applicable
local safety instructions and regulations.
Specic working conditions or selected accessories may require additional saety
instructions. Contact your supplier immediately if you detect a potential danger
when using these Units.

UV-O Odour Control Units
Technical and Operations Manual - Safety 2
1.2 Safety Warnings and Instructions
The ollowing symbols and notications are used in this manual:
WARNING!
Used to indicate where there is a risk of injury or death.
WARNING! - DANGER OF ELECTRIC SHOCK!
Used to indicate where there is a risk of injury or death from electric
shock.
WARNING
Used to indicate that Ozone (O3) is produced by this Unit
WARNING
Used to indicate that the Unit contains lamps that produce UV light.
CAUTION
Used to indicate where there is a risk of damage to equipment.
INFORMATION
Important information or useful hints about usage.
RECYCLING
Recycling information.
WEEE REGULATIONS
Used to ensure that waste electrical equipment is disposed of correctly.

Technical and Operations Manual - Safety 3
UV-O Odour Control Units
1.3 Pictograms, Warnings and Instructions Displayed on the Unit
The pictograms, warning and instructions attached to the Unit are, themselves, safety
features.
They must not be covered or removed and must remain present and legible through the
entire life of the Unit.
●Immediately replace or repair damaged or illegible pictograms, warnings and
instructions.
Figure 1 -
UV-O 500
0800 0184000 www.purifiedair.com
This system contains UV light which is
harmful to skin & eyes, isolate before opening.
This system produces ozone.
If you smell ozone isolate unit and ventilate area.
WARNING
WARNING
UV-O 500 Unit Label
Figure 2 -
UV-O 1000
0800 0184000 www.purifiedair.com
This system contains UV light which is
harmful to skin & eyes, isolate before opening.
This system produces ozone.
If you smell ozone isolate unit and ventilate area.
WARNING
WARNING
UV-O 1000 Unit Label
1.4 Safety Features
To prevent inadvertent exposure to UV light, the UV-C lamps are secured behind locked
panels, with the Units automatically shutting down when these panels are unlocked.

UV-O Odour Control Units
Technical and Operations Manual - Safety 4
CAUTION
●All saety eatures must be correctly tted and can only be
removed for maintenance and repair jobs by skilled and authorised
service engineers.
●These Units must not be used if the safety features are not fully
present or defective.
●The safety features should be regularly checked for their proper
functioning and, if defective, should be immediately repaired.
1.5 Safety Warnings and Cautions
WARNING! RISK OF EXPLOSION!
These Units are not explosion-proof rated. They can cause sparks and
should therefore not be used in areas with an explosion risk.
WARNING!
Ozone (O3) is produced by these Units. Ozone can be poisonous at
certain levels of concentration.
Inhalation of ozone causes dryness of the mouth, coughing, and
irritates the nose, throat, and chest.
It may cause difculty in breathing, headaches and atigue, and
could aggravate existing bronchial conditions including asthma.
The characteristic sharp, irritating odour is readily detectable at low
concentrations (0.01 to 0.05 ppm).
UNIT MUST NOT BE OPERATED WITHOUT KITCHEN EXTRACT FAN
RUNNING.
WARNING! - DANGER OF ELECTRIC SHOCK!
●To avoid electric shock:
●Do not operate these Units without a proper electrical ground/earth.
●Always disconnect power to these Units and isolate them from the
power supply before performing any service or maintenance.
●Do not operate these Units if their power cables are damaged, or if
any other damage to them is visible or suspected.
●The supplied utility/mains power must match the power
requirements listed on the Units’ rating labels.
WARNING!
●These Units contain lamps that produce UV light.
●Avoid exposure to direct or reected ultraviolet rays.
●Immediate or prolonged exposure to UV light can result in painful
eye injury, skin burn, premature skin aging, or skin cancer.

Technical and Operations Manual - Safety 5
UV-O Odour Control Units
CAUTION
●Regularly inspect your Unit and check it for damage.
●Verify the correct functioning of all of the safety features.
●Read and save all notices, warnings and safety instructions
received with your Unit.
●Do not alter the construction or design of these Units.
●Do not remove safety labels or devices.
●Do not use these Units for other than their intended purpose; as
described in this manual.
●Only use original spare parts.
●Keep the operating controls free from dirt and grease.
CAUTION
●Make sure the room is always sufciently ventilated, particularly in
smaller conned areas.
●Do not use these Units at a relative humidity exceeding 75%.
●Do not use these Units at temperatures below 5°C or above 56°C.
●Check the working environment. Do not allow unauthorised persons
to enter the working environment.
●Use common sense. Stay alert and pay attention to your work. Do
not use these Units when you are tired or under the inuence o
drugs, alcohol or medicine.
1.6 Modifications
Modication othese Units is not permitted.
1.7 Users
Installation or maintenance of these Units is exclusively reserved for authorised, trained
and qualied users.
Temporary personnel and trainees should only access these Units under the supervision
and responsibility oauthorised, trained and qualied users.

UV-O Odour Control Units
Technical and Operations Manual - Safety 6
1.8 Technical Specifications
1.8.1 Rating Plates
Figure 3 -
odlUVO V
r o UVO
UV-O 500 Unit Rating Plate
Figure 4 -
odlUVO V
r o
UV-O 1000 Unit Rating Plate

Technical and Operations Manual - Product Overview 7
UV-O Odour Control Units
2. Product Overview
Figure 5 - UV-O 500 Unit
Figure 6 - UV-O 1000 Unit Installed
2.1 Intended Use
UV-O Odour Control Units are designed to eiciently remove odorous compounds rom the
fumes extracted from commercial kitchens.
Simple to install, the Units are designed to be located on the outside of the ducting. The fact
that they are externally located makes these Units ideal for retrospective installations and,
as the UV lamps are outside of the airstream, maintenance requirements are minimal.

UV-O Odour Control Units
8
To maximise the Units’ efciency, they should be installed into the extraction ducting oa
commercial kitchen, down stream of the extraction hood on the negetive side of the fan.
CAUTION
Using these Units for other purposes is considered contrary to their
intended use. The manufacturer accepts no liability for any damage
or injury resulting from such use.
These Units have been built in accordance with state-of-the-art standards and recognised
safety regulations.
CAUTION
Only use these Units
●If they are not damaged in any way.
●After following the instructions laid down in this manual.
2.2 Features
When installed correctly, Puried Air’s UV-O Odour Control Units have the ollowing
eatures and benets:
●Use highly eicient UV-C technology.
●Robust, compact construction.
●Twelve month eective lamp lie.
●Minimum maintenance requirements.
●Enhanced safety - UV-C lamps are locked behind panels.
●Optional self-diagnostic system.
●Designed to complement our Electrostatic Precipitator (ESP) system.
●Reduce the need for duct cleaning.
●Can reduce cooking odours by up to 90%*.
●Grease is broken down in to more easily managed compounds.
●Virtually no pressure increase within the duct.
* In particularly odourous environments, high levels of odour control will only be
achieved by also using good quality particulate control systems (particularly ESPs) and
supplementary odour control systems in conjunction with this Unit.
2.3 Operating Principles
Puried Air’s UV-O Odour Control Units contain either two (UV-O 500) or ten (UV-O 1000)
high output UV-C (short-wavelength ultraviolet radiation) lamps and are designed to be
located outside the extraction duct.
2.3.1 Ozone and Free Radical Production
The UV light produced by the UV-C lamps converts oxygen present in the air into ozone.
Technical and Operations Manual - Product Overview

Technical and Operations Manual - Product Overview 9
UV-O Odour Control Units
Ozone is a highly reactive oxidant which interacts with most contaminants, allergens and
odour producing compounds it comes into contact with, oxidising them and rendering
them harmless.
The UV light produced by the lamps can also further convert the ozone to hydroxyl free
radicals in the presence of water or water vapour.
Free radicals are highly reactive oxidants which makes them eective natural air cleansing
agents.
The mixture of ozone and hydroxyl free radicals produced in this way creates a much
more powerful oxidising action (Ozonolysis) than the use of ozone alone.
2.3.2 Location
It is widely accepted that the best way to apply UV-C is in the airstream itself. However, in
such a situation, the lamps can quickly become dirty, greatly reducing their eectiveness.
Unlike other UV-C systems, the UV-O Odour Control Units are designed to be located
outside of the kitchen extract duct, connected via a spigot.
Negative pressure forms as the extract fume is drawn down the duct across the spigots
opening, thus drawing ambient air into the Unit and across the UV lamps producing Ozone
which is then introduced into the duct.
As the ambient air is relatively contaminant ree the lamps stay cleaner allowing a more
constant production of Ozone.
2.4 Components
2.4.1 UV-O 500 Components
The UV-O 500 Unit consists of a Main Chassis which contains the UV lighting source
behind a lockable, hinged, access panel.
A green Power Light and blue Saety Light are located on the lower Panel othe Unit.
An Airlow Sensor (See Figure 8 - Air Flow Sensor on page 10) is mounted on the right
hand side of the Main Chassis below the Duct Connection Spigot.
The Air Inlet is located on the let hand side othe Unit (See Figure 9 - Air Inlet on page
10).

UV-O Odour Control Units
Technical and Operations Manual - Product Overview 10
Figure 7 -
Door Lock
Air Inlet
Plan
Power Light
Safety Light
Air Flow Sensor
Duct Connection
Spigot
View On ‘A’ View On ‘B’
BA
Front View
UV-O 500 - Views
Figure 8 - Air Flow Sensor Figure 9 - Air Inlet
2.4.2 UV-O 1000 Components
The UV-O 1000 Unit consists of a Main Chassis which contains the UV lighting source
behind a lockable hinged access panel also secured with our star knobs. A Control
Panel, on the right hand side othe Main Chassis, contains the Rotary Mains Isolation
Switch green Power Light and blue Saety Light.
An Airow Sensor (See Figure 11 - UV-O 1000 Air Flow Sensor and Air Outlet on page

Technical and Operations Manual - Product Overview 11
UV-O Odour Control Units
11) is mounted on the right hand side othe Main Chassis below the Airow Outlet/Duct
Connection Spigot.
The Air Inlet, containing the Unit’s lter, is located on the let hand side othe Unit (See
Figure 12 - Air Inlet on page 12).
Figure 10 - UV-O 1000 - Front and Side Views
Figure 11 - UV-O 1000 Air Flow Sensor and Air Outlet

UV-O Odour Control Units
Technical and Operations Manual - Product Overview 12
Figure 12 - Air Inlet
Other manuals for UV-O 500
1
This manual suits for next models
1
Table of contents
Other Purified Air Control Unit manuals
Popular Control Unit manuals by other brands

OPW
OPW 1DK-2100 EVR Installation and maintenance instructions

Asco
Asco 8316 Series Installation & maintenance instructions

Hoft & Wessel
Hoft & Wessel HW 86012 Firmware manual

Adeunis RF
Adeunis RF TWIMO Series user guide

SMC Corporation
SMC Corporation VNA1 series instruction manual

Elko
Elko Smart EKO07144 manual