Qlightec QLEX-TRI-240 User manual

PB 1
QLEX-TRI-240(PL)
6040
67
66
Ex
1. Explosion proof products should be managed according to explosion-proof regulations. Do not disassemble, assemble, alter or repair
the product arbitrarily.
2. The temperature rating of the product is the temperature the product will experience at the applied rated voltage and ambient
temperature indicated.
3. Please use cable gland that is recommended by Qlight.
4. Before installing the product, please make sure all cautions indicated on the labels, packaging, and operation manual of the product are
fully understood.
5. Installation, maintenance and repair of the product must be performed by experts in the explosion proof ¿eld, or persons who have
received relevant training.
6. For safety, the product should be installed and operated in environments that avoid high temperature and high pressure.
7. Please follow general safety precautions and avoid installing the product in locations that may generate excessive heat.
8. When installing the product in places where chemicals are located, please make sure that the environment does not have two or more
incompatible chemicals mixed. For safety, please read the instruction manual carefully and be mindful of the chemical compositions
where the product is used.
9. Please be careful of static electricity during product installation.
Please eliminate static electricity by using static eliminator or handle the product with anti-static globes.
10. Please contact Qlight if cable gland maintenance is required since power cable and cable gland are also explosion proof type.
11. This product is an explosionproof certi¿ed product with a minimum power cable length of 2m. Do not cut the power cable arbitrarily.
1. During wiring or maintenance, please completely turn o-• the power of the product. (Failure to follow this may lead to an electric shock.)
2. Do not install the product in locations that subjects it to excessive dust or water other than the conditions designated by the IP protection
ratings indicated for each product. (Failure to follow these instructions may cause a ¿re to the product, electric shock, physical injury,
malfunction or damage to the product.)
3. Do not alter or repair this product. If maintenance or repair service is required, please contact your local Qlight contact point.
(Failure to follow these instructions may lead to ¿re, electric shock, or product damage.)
4. Please apply the correct voltage to the product. (Failure to follow these instructions may lead to ¿re, electric shock, or product damage.)
5.
When the product is applied to a condition that may impact lives or property, please make sure to have a double safety device.
(Failure to follow this may cause damage to property, ¿re, electric shock and loss of life.)
Precaution for Safety
Failure to follow the instructions below may cause a loss of life or serious physical injury.
1. Please remove any objects that can interrupt ventilation around the product.
2. Please turn o-• the power of the product immediately if it fails to operate properly.
3. Carefully wire the product according to each product’s speci¿cation.
4. Please be careful in preventing chemicals such as thinner, benzene, etc. in contact with the surface of the product.
5. Do not apply excessive force/impact to the product.
6. Failure to follow any of the instructions above may cause malfunction or damage to the product, ¿re, and electric shock.
7. Static electricity may be generated by physical contact due to the surface characteristics of this product so please use a wet towel
or anti-static cleaner to remove the foreign substances on the product.
Precautions for Correct Use
Failure to follow the proper instructions may cause damage to property, the product, or malfunction of the product
that would void the warranty.
Please scan the QR code
for more
detailed product information.
www.qlight.com
Thank you for purchasing Qlight’s products. Please read this user manual carefully
prior to installation and operation to ensure safe and correct use.
Safety Precautions for Explosion Proof Products
Please follow the instruction below to ensure safe and correct use of explosion proof products.
Explosion Proof LED Work Light

2 3
Zone
de¿nitions(Gas) Zone 1 High risk gas/vapour
Zone 2 Medium risk gas/vapour
Group
de¿nitions(Gas)
GROUP II A Acetone, Petrol, Methanol, Propane, Toluene
GROUP II B Ethylene, City gas
GROUP II C Hydrogen,Acetylene, Carbon sulphide
Maximum surface
temperature of
electrical equipment
T1 450°C
T2 300°C
T3 200°C
T4 135°C
T5 100°C
T6 85°C
Zone
de¿nitions(Dust) Zone 21 High risk powder/dust
Zone 22 Medium risk powder/dust
Group
de¿nitions(Dust)
GROUP III A Ignitible ¿bers/yings(more than 0.5mm)
GROUP III B Non-conductive dusts
GROUP III C Conductive dusts
QLEX-TRI - 240(PL) - 24
[Model number] [Length] [Voltage]
| | |
• QLEX-TRI • 240-240mm • 24-DC24V
General Product Speci¿cation
Model number QLEX-TRI-240(PL)
Rated voltage DC24V
Range for operation
voltage DC21.5V-26.5V
Power consumption 8.6W
Insulation resistance Min. 100M(500V DC mega ohm meter)
Withstanding voltage DC : 500VAC, 60Hz, 1 minute
Protection rating IP66/67
Materials Side cover-Al, Lens-PC, Bracket-PC
Certi¿cate
Weight(approx.) 0.62Kg
Optics Speci¿cations
Model number QLEX-TRI-240(PL)
Lens color Translucent
Light color (Standard) Cooldaylight
Color temperature
(Standard) 6,000-7,000 K
Luminous ux 650lm
Illumination(at 1m) 310Lux
Model number
QLEX-TRI-240(PL)
Range for
operating voltage
DC24V
Ex mark
Ex d IIC T6
Ambient operating
temperature
–40°C ≤ Tamb ≤ +60°C
Explosion proof
Group / Zone
Zone1, Zone2
Protection rating
IP66/ IP67
■
Explosion Proof Specications
Product Specications
Ordering Specications
■ Optics Specications/ General Product Specication

2 3
QLEX-TRI-240(PL)
• This product is internally grounded(External grounding available).
• Green/Amber is the ground wire among signal lines.
Ground wire - Green/Amber Ground(Internal ground) - Green/Amber
• External power line - VCTF-0.75sq x 3C-(Min) 2M
•
External power line(Customization)- OLFLEX 550 P 3G1.5-(Min) 2M
• This product can be wired regardless of polarity.
Fuse
Power
FG(Grounding)
Brown
Sky Blue
Green/Amber
Dimensions
(Units : mm)
Grounding Instructions
Wiring Instructions
BRACKET (PC)
WARNING LABEL
EXPOLSION PROOF LABEL
224
244
EXPLOSION PROOF
CABLE GRAND M12xP1.5 2
20
90
105
240±2
Min. 2m
52
43 154
47
55
70
4-R3
38.5
BRACKET (PC)
LIGHTING DIRECTION
EARTH GROUND-M4
OUT
BRACKET INSTALLATION
Ø40
240±2
3M (Min. 2m)
52
43 154
LIGHTING DIRECTION
50.7
51.7
QLEX-TRI-240(PL) PRODUCT LAY-OUT
BROWN
SKY BLUE
GREEN+YELLOW
INTERNAL EARTH GROUND
Ø40

4
Installation/ Mounting Hole Specications
•
First, machine taps or holes on the mounting surface.
•
The mounting hole of this product is 6.5mm in diameter(hole).
•
When machining taps, fasten the bolt through the mounting hole of the product.
•
When machining holes, insert the bolt through the hole of the product, and tighten the nut from the opposite side of the mounting surface.
• Machine holes on the mounting surface referring to the diagram below.
.
■
Installation
■
Mounting Hole Specications
Installation Environment and Protection Rating
• This product is designed to be explosion proof.
• Please make sure to use the product in an environment that meets the speci¿ed explosion proof rating and regulations.
• For further information, please visit our website (www.qlight.com).
Parts Denition/ Bracket Fixing Instructions
• Fix the brackets at the position where the product will be installed
• Install the brackets ①and ②as the installation dimension of ③.
• Push the work light ④in the direction of the arrow ⑤.
• After assembling, check whether assembling is normal as shown
in the picture ⑥.
• When the work light assembled to the bracket unstable, be careful
about damage caused by product dropping.
※The bracket of this product is a press-¿tting assembly type bracket
made of PC. It is manufactured by press-¿tting type of PC material
for easy assembly/disassembly of work light.
①Bracket ②Bracket ②Bracket
③224
⑤Arrow ⑤Arrow
④Work light ③ Work light
⑥After
assembly
Bracket(PC)
Bracket(PC)
Ground wire - G/A
Power
cable Bracket bolt(STS)
(External ground)
Side cover(Al)
Side cover(Al)
Lens(PC)
Heat sink(Al)
90
224
4-Ø6.5

Product installation direction
■ Install the product in accordance with the manual. Otherwise rainwater or moisture may penetrate into the product.
ㆍ ELECTRONIC SOUNDER/SIGNAL HORN
Sounder part shall not be facing the sky.
Sounder part shall not be facing the sky.
ㆍBEACON/SIGNALING LIGHT
Power cord inlet part shall not be facing the sky.
Power cord inlet part shall not be facing the sky.
ㆍSIGNAL TOWER LIGHTS
ㆍHEAVY-DUTY & EXPLOSION PROOF SIGNALINGS
※For products with a protection rating of less than IPX4, please install it vertically.
※For products with a protection rating of less than IPX4, please install it vertically.

MEMO

MEMO

Head O-ce | Suite #1510, STX-V Tower, 128 Gasan digital 1-ro, Geumcheon-gu, Seoul, Korea
Tel. +82-2-2679-6152(Toll free. +82-80-328-2222) Fax. +82-2-2679-6154
Factory | 185-25, Mukbang-ro, Sangdong-myeon, Gimhae-si, Gyeongsangnamdo, Korea Tel. +82-55-328-1111(Toll free. +82-80-328-1111)
Qlight OverSEAs Sales Dept |
704 Nakdong-daero, Sasang-gu, Busan, Korea(Eomgung-Dong) Tel : +82-51-620-4100
Qlight Public Relations & Marketing Team O-ce | 704 Nakdong-daero, Sasang-gu, Busan, Korea(Eomgung-Dong) Tel. +82-51-245-0017
3003 North First Street, Suite #341, San Jose, CA 95134 USA Tel. +1 - 408 - 519 - 5740 Fax. +1 - 408 - 519 - 5739
China Factory/ Shanghai Sales O-ce | #19, Nanda Road, Baoshan Area, Shanghai, China Tel. +86
-
21
-
6651
-
7100 Fax. +86
-
21
-
6315
-
3929
China Factory Site 2 (Qidong) | #33, Haiyan Road, Qidong High-tech Industrial Development Zone, Qidong, Jiangsu Province, China
Tel +86
-
513
-
8384
-
9999 Fax +86
-
513
-
8384
-
9910
Product Operation Inquiry / Customer Support +82-51-620-4100
You can expect prompt service if you have exact information such as model name, symptom, telephone number and address.
※ALL PRODUCT, PRODUCT SPECIFICATIONS AND DATA ARE SUBJECT TO CHANGE WITHOUT NOTICE TO IMPROVE
RELIABILITY, FUNCTION OR DESIGN OR OTHERWISE.
Head office : Suite #1510, STX-V Tower, 128 Gasan digital 1-ro, Geumcheon-gu, Seoul, Korea ( Postal Code : 08507)
Factory : 185-25, Mukbang-Ro, Sangdong-Myeon, Gimhae-Si, Gyeongsangnam-Do, Korea ( Postal Code : 50805)
For your safety
Speci¿cation and dimensions listed in this catalogue subject to change without notice for product quality improvement.
The newest product information is available on our website.(www.qlight.com)
Please read the instruction manual attached to the product carefully before installation and use.
www.qlight.com
EN - QLEX-TRI-240(PL) - 2305A
This manual suits for next models
1
Table of contents
Other Qlightec Work Light manuals

Qlightec
Qlightec EPLS Series User manual

Qlightec
Qlightec QLEX-NEC-250 User manual

Qlightec
Qlightec EBL Series User manual

Qlightec
Qlightec EPL Series User manual

Qlightec
Qlightec QLEX-NEC-250 User manual

Qlightec
Qlightec QLEX-350 User manual

Qlightec
Qlightec QMFL300-Ex-24 User manual

Qlightec
Qlightec EHL Series User manual