QNN Safe AH/B Series User manual

QNN SAFE AUSTRALIA PTY LTD
ABN 47 168 078 233
Unit 9 / 376 Newbridge Road, Moorebank NSW 2170
Web site: www.qnnsafe.com.au
Email: [email protected]om.au
Phone: 02-87982669
Page 1 of 4
USER’S MANUAL FOR AH/B SERIES
SAFE
Serial Number:
This package contents:
User manual
4 bolt down Screws M12mm x 80mm
4 AA Batteries (8 For F-3020EE)
Please contact your dealer or Qnn Safe Australia P/L if any shortage accrued
For the first time use, it needs to supply 4 AA batteries power to the safe:
Counter clockwise the Keypad then to insert the supplied 4 AA batteries into the
Battery Box:
After enter the right code, then turn the handle clockwise to open the door
This safe is operated by the digital code.
The factory setting for the Master Code is: “1 2 3 4 5 6 “
Opening instructions:
Single Control Mode : Press and then the code, and then press .(Factory
setting at Single Control Mode , Master Code “123456”)
Dual Control Mode: Press and then the first code, and then press , and then
the second code, and then press . (Please note: The pause between the two code
entering is 60 seconds)
Green light on with one beep indicated that the digital lock is unlock.( factory
setting master code “123456”)
Turn the handle clockwise, safe now is unlocked.

QNN SAFE AUSTRALIA PTY LTD
ABN 47 168 078 233
Unit 9 / 376 Newbridge Road, Moorebank NSW 2170
Web site: www.qnnsafe.com.au
Email: [email protected]om.au
Phone: 02-87982669
Page 2 of 4
All light off with 2 beeps means a wrong code try. 3 continual wrong code tries
will lead a freezing period of 5 minutes
Closing instructions:
Close the door
The handle will automatic counter clockwise and the door is locked.
Changing Master Code:
Please keep the door at opening position during the whole processing until fully
ensure that the code is changed correctly.
For security reasons, please change to your own code after the first opening.
Your code can be set up to 10 digits
Open the safe door
Press then enter Master Code, then press . Orange light on with one beep.
Press , press and then enter New Master Code then press
Enter New Master Code again then press to confirm.
Orange light on with one beep means the Master Code has been change successful
Keep the door open, check and remember the code
Orange light off with two beeps means changing is fault. And the old Master Code is still in
place.
User setting:
Under the control of the Master Code, the maximum user of this safe can be set up to 6:
The supervisor is able to setup and delete up to other 5 users.
User Number 2: for Supervisor
User Number 3 - 7: for other 5 user.
To set New Supervisor Code by Master:
To set up: Press then Master Code then press , enter New Supervisor
Code then press , enter New Supervisor Code again then press to confirm.
To delete: Press then Master Code then press
To set New User Code by Master / Supervisor :

QNN SAFE AUSTRALIA PTY LTD
ABN 47 168 078 233
Unit 9 / 376 Newbridge Road, Moorebank NSW 2170
Web site: www.qnnsafe.com.au
Email: [email protected]om.au
Phone: 02-87982669
Page 3 of 4
To set up: Press then Master Code / Supervisor Code then press then enter the
User Number (Could be from 3 to 7) then press , enter New User Code then press ,
enter New User Code again then press to confirm.
To delete: Press then Master Code / Supervisor Code then press then enter the
User Number the press
Changing Supervisor Code by supervisor:
Please keep the door at opening position during the whole processing until fully
ensure that the code is changed correctly.
For security reasons, please change to your own code after the first opening.
Your code can be set up to 10 digits
Open the safe door
Press then enter Supervise Code, then press . Orange light on with one beep.
Press , press and then enter New Supervise Code then press
Enter New Supervise Code again then press to confirm.
Orange light on with one beep means the Master Code has been change successful
Keep the door open, check and remember the code
Orange light off with two beeps means changing is fault. And the old Supervise Code is still
in place.
Changing User Code by user:
Please keep the door at opening position during the whole processing until fully
ensure that the code is changed correctly.
For security reasons, please change to your own code after the first opening.
Your code can be set up to 10 digits
Open the safe door
Press then enter User Code, then press . Orange light on with one beep.
then enter New User Code then press
Enter New User Code again then press to confirm.

QNN SAFE AUSTRALIA PTY LTD
ABN 47 168 078 233
Unit 9 / 376 Newbridge Road, Moorebank NSW 2170
Web site: www.qnnsafe.com.au
Email: [email protected]om.au
Phone: 02-87982669
Page 4 of 4
Orange light on with one beep means the Master Code has been change successful
Keep the door open, check and remember the code
Orange light off with two beeps means changing is fault.And the old Code is still in place.
Other features:
Dual control mode: safe needs to be opened under two digital codes. There are two dual
control mode.
Press then Master Code then press , press , press .
Control by any 2 normal user (User Number 3 –7)
Press then Master Code then press , press , press .
Control by one of the Master Code or Supervisor Code with one normal user
(User Number 3 –7)
To delete the Dual control mode: Press then Master Code then press ,
press , press . Go back to the Single control mode.
Time delay function: Time delay can be set from 60 seconds to 99 minutes.
Press will enter the time delay period. During the time delay period,
Yellow light flash every 5 seconds and all keys are locked.
SET light flash at last 10 seconds, and the period ended with two beeps.
There are 2 minutes operation period before entering into the next Time delay
To activate: Press then Master Code then press , @@ then press ,
@@ then press to confirm. (@@ : 01 –99 miniutes)
To de-activated: Press then Master Code then press , then
press , then press to confirm.
Cautions:
When the green light change to yellow, it means that the batteries need to be
replaced. Please replace new batteries as soon as possible.
Table of contents
Other QNN Safe Other manuals
Popular Other manuals by other brands

Iron-Fence Shop
Iron-Fence Shop STRONGHOLD IRON installation guide

Whirlpool
Whirlpool 8535841 installation instructions

York Survey
York Survey 28235 operating instructions

Essentials
Essentials Currys user manual

Freedom
Freedom Somerset installation instructions

DS Produkte
DS Produkte 02347 operating instructions