Quality Clever PivyCord-V User manual

Back Side
Back Side
PivyCord Chain
Screwdriver (for Opening Chain Latches)
CleverCord Mounted Cable Ties, Qty 4
CleverCord Cable Wrap Ties, Qty 10
Screws, #6 x 1/2” (M3.5 x 12mm), Qty 8
Desk Foot Scratch Protector (use if your Desk Foot is
Ferromagnetic)
Lower Striker Plate with Double-Sided Tape Backing
(use if your Desk Foot is Non-Ferromagnetic)
Upper Striker Plate, Note: An Extra Double-Sided
Tape Strip is included for use on Desktops where
Screws Cannot be used (Glass-Top, Granite,
Non-Ferromagnetic Metal)
A
B
CD
F
GH
E
A
B
C
D
E
F
G
H
Maximum Desk/Table Vertical Travel Range Low: 20” (46cm)
(Underside of Desk to Top of Foot) High: 48” (127cm)
Front-to-Back Offset between Upper & Lower Brackets 7” min to 12” max
Upper and Lower Brackets (18 to 30cm)
Minimum Bend Radius (the Pivy Chain ensures 1.9” (48mm)
Cables will not bend smaller than this radius)
1.2” x 0.6”
(30 x 15mm)
Maximum Connector Width (Cable ends must be 1.3” (33mm)
passed through this hole during installation)
Magnetic Bracket Vertical Holding Force 25 lbs (12kg)
Cycle Life (Number of times the Desk/Table can be Raised 500,000 cycles
Raised and Lowered without PivyCord mechanism failure)
* INDOOR USE ONLY
Cable Raceway Opening Size
1
2
3
4
5
6
7
SPECIFICATIONS
4
1
2
3
3
5
7
6
5
Important SAFETY INFORMATION
• Choking Hazard, Contains Small Parts, Keep Away from
Children and Pets.
• Contains Small Magnets, Keep Away from Children and Pets.
Do not put in mouth or nose.
• Magnets can shatter if dropped on a hard surface. Handle with
care. Shattered magnet fragments can be sharp, and are
harmful if swallowed. Keep away from Children and Pets.
WARNING
CAUTION
• This cable chain and mechanism has multiple pinch points and
hazardous moving parts. Keep fingers and all body parts away
from all moving parts. Avoid pinch points. Wear protective
clothing such as gloves and long sleeves, as appropriate, when
handling this device.
• Discontinue use in case of damage to the product. Use only for
its intended purpose.
CALIFORNIA PROPOSITION 65 WARNING
•
WARNING: This product can expose you to chemi-
cals including Nickel Oxide, which is known to the
State of California to cause cancer and birth defects
or other reproductive harm. For more information go
to www.P65Warnings.ca.gov
KIT CONTENTS
https://www.QualityClever.com/Install/PivyCord-V
VIEW INSTALL
VIDEO HERE
PivyCord-V
User’s Guide
FLEX RACEWAY COMPACT DESIGN CLEAN LOOK
Cable Management System
For Variable-Height
Sit/Stand Desks and Tables
FERROMAGNETIC?
Simply stated, if a magnet is
attracted to the item, it is ferromagnetic.
For example, Steel and Iron are ferromagnetic,
and Aluminum is non (or anti) ferromagnetic.

RAISE DESK TO MAXIMUM HEIGHT,
CHOOSE INSTALL LOCATION
• Left or Right Desk Leg,
• Back or Front of Desk Leg
1
LEFT-
FRONT
RIGHT-
FRONT
LEFT-
BACK
RIGHT-
BACK
Apply the Clear Scratch Protector
Sticker as shown.
Apply the Lower Striker Plate with Adhesive
Tape as shown.
PREPARE ANCHOR LOCATION FOR LOWER MAGNETIC BRACKET
2
NO
YES
F
G
F
G
WHEN REMOVING MAGNETIC
END BRACKETS
Tilt to the side rather than trying
to pull straight off
THISSIDEDOWN
X
THISSIDEDOWN
✓
G
F
IS YOUR DESK FOOT FERROMAGNETIC?
INSTALL UPPER STRIKER PLATE (ANCHOR
LOCATION FOR UPPER MAGNETIC BRACKET)
Place a mark on the underside of the desk directly
in-line with the Lower Anchor Location (from Step )
approximately 7” (18cm) away (can be up to 12” if needed).
Ensure that that the location has a minimum 3” x 3” flat
surface area. Fasten the Striker Plate on the marked location
according to the Desktop Material Type as shown.
3
2
7”
18cm
Upper Anchor
Location
Lower Anchor
Location
H
Fasten the provided extra
Double-Sided Tape Square to
the back of the Upper Striker
Plate . Attach the Upper
Striker Plate using the
Double-Sided Tape to a clean,
dry surface at the marked
location on the underside of the
Desk/Table.
H
H
The Upper Magnetic Bracket
can attach directly to the under-
side of the desk, here. No
Upper Striker Plate is
required. Move to the next step.
H
H
Attach the Upper Striker Plate with
4 Screws at the marked location
on the underside surface of the
Desk/Table. Ensure that the screws
are shorter than the thickness of
the desk.
E
H
WHAT IS YOUR DESKTOP MATERIAL TYPE?
E
H
WOOD or COMPOSITE
FERROMAGNETIC METAL
GLASS, GRANITE or
NON-FERROMAGNETIC METAL
H
INSTALLATION

OPEN ALL CHAIN LATCHES
Make sure all of the Latches on the PivyCord Chain are open. To open a latch, insert
the tip of a small Flathead Screwdriver into the slot underneath the Latch on the side
with the open icon. Push downward on the handle to pop the latch open.
CAUTION: When handling the PivyCord Chain, be careful to avoid the pinch-points on the back side
of the chain that can pinch fingers and skin. Keep away from Children.
4
A
B
A
B
SNAP THE UPPER AND LOWER MAGNET BRACKETS OF THE PIVY
CHAIN IN PLACE
Confirm the correct UP/DOWN orientation of the Pivy Chain with the
“THIS SIDE UP” and “THIS SIDE DOWN” markings. Snap the Upper Magnet Bracket of
the Chain in place on the Upper Striker Plate then snap the Lower Magnet in place on
the Desk Foot.
5
THIS SIDE UP
THIS SIDE DOWN
THISSIDEDOWN
A
A
UPPER
LOWER
A
UPPER
CHAIN
SECTION =
18 LINKS
LOWER
CHAIN
SECTION =
29 LINKS
PULL ALL CABLE ENDS THROUGH
THE HOLE IN THE CENTER LINK OF
THE PIVY CHAIN
Depending on your setup, some cables will be
easier to pull up from the bottom and others will be
easier to feed down from the top.
6
A
A
Center
Link
CD
SECURE ALL CABLES ON THE DESKTOP AND UNDERSIDE OF THE DESK
Connect all cables to your desktop equipment. Use the CleverCord® Mounted Cable Ties and
CleverCord® Cable Wrap Ties to route and secure the cable bundles to your desktop and to the
underside of your desk. If you will be using a Quality Clever Cable Tray (sold separately) on the underside of
your desk, install it now as well.
CAUTION: The CleverCord Mounted Cable Tie adhesive is permanent, and can pull off paint or furniture
finish when removed.
7
TOP OF DESK
UNDERSIDE OF DESK
C
D

CLOSE THE PIVY CHAIN LATCHES
Swing open all of the latches on the Pivy Chain and push all cables into the raceway opening, pulling any slack downward. Working from top to bottom,
close all chain latches by pressing down with your thumbs on the center of each latch until you feel a click.
8
A
A
AA
SECURE CABLES AT THE BASE, TEST THE FULL
RANGE OF MOTION
Secure your cables at the bottom of the Pivy Chain, at the
Desk Foot and on the floor using the CleverCord Mounted Cable
Ties and CleverCord Cable Wrap Ties as needed. Move
the Desk/Table down and up to test over the full range of motion to
ensure that the mechanism and all of your desk components move
smoothly, without any interference, binding, snagging or pinching.
CAUTION: The CleverCord Mounted Cable Tie adhesive is
permanent, and can pull off paint or furniture finish when removed.
9
CD
CD
ADDING, REMOVING OR MOVING CABLES
Pop open all of the Pivy Chain Latches (Step ), release
any cable management ties as needed. Add, remove, and move
cables as desired, then repeat Steps through .
4
5 9
Thank you for your purchase!
For Technical Support, Feedback or
Customer Service:
+1.888.861.1704
www.QualityClever.com
https://
Patent Pending
PivyCord, Pivy, CleverCord and Quality Clever
are Registered Trademarks
INSTALL VIDEO
Popular Office Equipment manuals by other brands

BuzziSpace
BuzziSpace BuzziNest Booth owner's manual

neuland
neuland IdeaBoard Assembly instruction

Dahle
Dahle 10550 operating instructions

STILFORD
STILFORD STMON160GY Assembly instructions

National Office Furniture
National Office Furniture 2513735 Assembly instruction

Office Star Products
Office Star Products Space Seating 13-V22N1WA operating instructions