Quantel CFR User manual

1. Attach coolant lines to the back
of the laser head and back of the power
supply: blue to blue and red to red.
2. Attach the double-connector side of the
electrical cable to the laser head. These
connectors have red dots indicating proper
orientation. Note: It is easier to attach
the bottom connector first. Ensure that the
connectors are fully seated. Note: You
should hear a “click”.
3. Attach the other end of the D-Connector
to the back of the power supply and
tighten the thumb screws completely to avoid connector contact damage.
Note: Never operate the laser system without the connectors of the electrical
cable fully inserted and the thumbscrews tightened.
∗ If you received a DI Cartridge that is not attached to the coolant lines,
instructions to attach the DI Cartridge are on the opposite side of
this Quick Start Guide.
4. Attach the remote box to the remote box interface on the front of the
power supply. Thread the silver collar on the connector until it is flush
with the front of the power supply.
5. Connect the power cord to the back of the power supply.
6. Remove the white plastic shipping cover from the front of the laser head.
Do not discard.
Quick Start Guide For Your CFR Laser System
WARNING: THIS IS A CLASS IV LASER. READ AND FOLLOW YOUR USER’S MANUAL BEFORE OPERATING TO AVOID DAMAGE OR PERSONAL INJURY.
CFR Laser Head/Standard ICE
450
Power Supply
1 UNPACK your system. Save your packing material.
Locate the following items:
Laser Head
ICE450 Power Supply
Coolant Lines* and Electrical Cables
Fill Bottle and Vent Tube
Accessory Kit (including keys)
Power Cord
Coolant (Distilled Water)
WARNING: OPERATING YOUR LASER WITHOUT COOLANT WILL CAUSE CATASTROPHIC FAILURE.
2 CABLE CONNECTION
Electrical Cables
Coolant Lines
DOC00076 Rev C
Vent Tube Connector
(Connect to the ICE450 Vent Port)
Fill Bottle Connector
(Connect the vent tube here)
3 1. Connect the vent tube to the fitting on the front of the reservoir
bottle.
2. Connect the vent tube to the reservoir vent port on the front of the
power supply.
3. Connect the fill bottle connector to the reservoir fill port on the front
of the power supply.
4. Add coolant to the fill bottle until water rises into the vent tube.
5. Insert the key into the power key switch and
turn it to the ON (“I”) position.
6. Continue to add coolant until the coolant lines
are full and the coolant level is visible in the
vent tube (above the minimum coolant level
indicator). Note: The pink illuminated section
indicates the actual coolant level.
7. Disconnect the fill and vent tubes.
8. Secure laser head to the table using three 8-32
UNC screws.
FILL
Reservoir Vent Port
Reservoir Fill Port
Minimum Coolant
Level Indicator
Fill Bottle Hose
(OVER)
Fill Bottle Connector
(Connect to the ICE450 Fill Port)
Power Key Switch
Remote Box Interface
Vent Tube Connector
(Connect to the Fill Bottle Connector)
Quick Start Guide For Your CFR Laser System
CFR Laser Head/Standard ICE
450
Power Supply
4 CONGRATULATIONS!
Your system is ready for full operation.
CONSULT CHAPTER 2 OF THE USER’S
MANUAL BEFORE CONTINUING FOR
APPROPRIATE EYE PROTECTION AND
SAFETY PRECAUTIONS.
1. Ensure that the red emergency stop button on top of the remote
box is pulled out.
2. See System Summary to verify the desired settings
on the remote box. See the User’s Manual for more
details of operation.
3. Press the “Flashlamp Start Button” on the
remote box.
4. Lasing will begin when the “Q-Switch Start
Button” is pressed on the remote box. The
yellow LED on the top of the laser head will
illuminate to indicate lasing.
Note: For systems with harmonics, it may take
several minutes for desired energy output to
stabilize.
DOC00076 Rev C
START UP
Yellow LED
Emergency Stop Button
Your laser is pre-configured to operate at full energy
and Pulse Repetition Frequency (PRF).
The only routine maintenance required on the CFR
system is deionization filter replacement and
flashlamp replacement. Cycle the coolant at least 30
minutes every month and replace the flashlamp as
required. See the User's Manual for details.
If you need to ship the laser for any reason, see the
User's Manual for details on draining the system for
transport to prevent freezing.
Flashlamp Start Button
Q-Switch Start Button
*DI Cartridge (not attached to the coolant lines):
If your DI Cartridge is not attached to the coolant lines,
please follow the steps below:
1. Remove the gray shipping fittings on the DI cartridge
by using two fingers to hold down the base of the
fitting while pulling straight out on the top of the
fitting (See Item 1). Repeat on the opposite side.
2. Remove the two gray caps from the fittings on the
coolant line (Item 2).
3. Attach the two sides of the DI cartridge to the coolant
lines at the fittings on both ends (Items 3- 4). Make
sure that the “Flow” arrow on the DI Cartridge is
pointing in the correct direction (away from the power
supply). Return to the “Cable Connection” section of
this Quick Start Guide.
FOR TECHNICAL SUPPORT
PLEASE CALL
CUSTOMER SERVICE:
QUANTEL USA: 1-800-914-8216
QUANTEL: (33)1-6929-1700
1
2
3
4

Other Quantel Measuring Instrument manuals

Quantel ULTRA User manual

Quantel

Quantel ULTRA User manual

Quantel Ultra Big Sky Laser Series User manual

Quantel

Quantel Ultra Big Sky Laser Series User manual

Quantel CFR User manual

Quantel

Quantel CFR User manual

Quantel Ultra User manual

Quantel

Quantel Ultra User manual

Quantel EverGreen2 User manual

Quantel

Quantel EverGreen2 User manual

Popular Measuring Instrument manuals by other brands

Tektronix RSA306 Technical reference

Tektronix

Tektronix RSA306 Technical reference

Humboldt FD-4A product manual

Humboldt

Humboldt FD-4A product manual

Trotec BD16 operating manual

Trotec

Trotec BD16 operating manual

GREISINGER GMH 3830 operating manual

GREISINGER

GREISINGER GMH 3830 operating manual

Sierra SmartTrak C100 instruction manual

Sierra

Sierra SmartTrak C100 instruction manual

TSI Instruments 3936 Operation and service manual

TSI Instruments

TSI Instruments 3936 Operation and service manual

TSI Incorporated aerotrak 9306-V2 Operation manual

TSI Incorporated

TSI Incorporated aerotrak 9306-V2 Operation manual

Fluke 714C user manual

Fluke

Fluke 714C user manual

Doyon WM35 manual

Doyon

Doyon WM35 manual

WATANABE ELECTRIC INDUSTRY CO., LTD AP-101-11 instruction manual

WATANABE ELECTRIC INDUSTRY CO., LTD

WATANABE ELECTRIC INDUSTRY CO., LTD AP-101-11 instruction manual

Extech Instruments 461920 user guide

Extech Instruments

Extech Instruments 461920 user guide

C2Max XTREME HD user manual

C2Max

C2Max XTREME HD user manual

Kobold MAN-SD series operating instructions

Kobold

Kobold MAN-SD series operating instructions

GREISINGER GMH 3431 operating manual

GREISINGER

GREISINGER GMH 3431 operating manual

SCADAmetrics EtherMeter EM-100 Installation, operation and maintenance manual

SCADAmetrics

SCADAmetrics EtherMeter EM-100 Installation, operation and maintenance manual

Fraba TILTIX MEMS AKS user manual

Fraba

Fraba TILTIX MEMS AKS user manual

NTI ENVIROMUX Series Quick installation guide

NTI

NTI ENVIROMUX Series Quick installation guide

Keysight Technologies M9710A Configuration and Measurement Instructions

Keysight Technologies

Keysight Technologies M9710A Configuration and Measurement Instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.