quiko QK-CE220WRL User manual

1 www.quikoitaly.com
Electronic Control Unit
QK-CE220WRL
An electronic control unit integrated into the Wind, Sun and
Rain Sensor compartment, for the automation of sun blinds and
rolling window shutters, with the possibility of radio control op-
eration for individual and/or centralised control.
TECHNICAL DATA
- Power supply: 230V~ 50/60Hz 600W Max.
- Motor output : 230V~ 500W Max.
- Operating temperature: -10÷55°C
- Radio receiver : 433,92 MHz
- Compatible radio controls: 12-18 Bit or Rolling Code
- Anemometer sensitivity: 5 ÷40 Km/h
- Sun sensor sensitivity: 5 ÷40 Klux
- Number of codes that may be stored: 10 Max.
- Packaging dimensions: 240 x 185 x 110
mm.
- Container: PC UL94V-0 (IP54)
CONNECTION OF CN 1TERMINAL BOARD
1: Earth.
2: 230 V line input (Phase).
3: 230 V line input (Neutral).
4: Upward movement motor output.
5: Shared motor output.
6: Downward movement motor output.
INITIAL OPERATING CONDITION
The device can only operate in conjunction with one or more
radio controls. There is no radio control code stored in the de-
fault factory setting.
OPERATION USING DIFFERENT MODELS OF RADIO CONTROL
Operation using a 3-button radio control (QK-TXTUB):
The following type of operation is obtained using the QK-
TXTUB radio control: the (Up) button controls the upward
movement until the end of the motor time, the (Stop) button
causes all movement to stop and the (Down) button controls
the downward movement. If a stop command is sent during the
upward or downward movement, the control unit causes this
movement to stop. If a command that is in the opposite direc-
tion to the current movement is sent during the upward or
downward movement, the control unit causes the shutter to
change direction.
Operation using a 3-button radio control (QK-TXTUB3/ QK-
TXTUB6):
When using the QK-TXTUB3/ QK-TXTUB6 radio control, you
will obtain the same operation as previously described for the
QK-TXTUB version; in addition, by using the keys (-) and (+) at
the sides of the radio control it is possible to select the UP –
STOP – DOWN controls for 3 different types of use (QK-
TXTUB3) or for 6 different types of use (QK-TXTUB6). In addi-
tion, by using the keys (-) and (+) at the sides of the radio con-
trol it is possible to enable and disable the sun sensor (the se-
lection is confirmed by a quick UP / Down movement of the mo-
tor).
INVERSION OF THE ROTATION MOTOR
If you notice that when pressing the UP key on the radio-control
the control unit causes the shutter to move upwards instead of
downwards, simply repeat the programming procedure pressing
the DOWN key instead of the UP key, or invert the motor’s Up-
ward movement wire and the Downward movement wire.
GROUP OR GENERAL CENTRALISATION
It is also possible to enter two identical codes ( buttons ) from
one radio control onto all the control units or a group of them
which are situated at a maximum distance of 20 metres from
the point of command, in order to obtain general or partial mo-
tion of more than one automation.
ANEMOMETER OPERATION
The electronic control unit will cause the sun shade to move
upwards every time the wind exceeds the selected threshold.
SUN SENSOR OPERATION
The electronic control unit controls the downward movement of
the sun shade after 5 minutes during which the brightness is
greater than the threshold selected using the VR1 trimmer and
displayed when the SUN LED lights up; it also controls the up-
ward movement of the shade after 5 minutes during which the
brightness is below the selected threshold.
Sun sensitivity adjustment ( 5 ÷ 40 Klux )
The control unit allows you to adjust the sensitivity of the Sun
Sensor using the VR1 trimmer. When the SUN LED lights up
on the control unit, this indicates that the intensity of the sun
exceeds the selected threshold; this enables you to use the cur-
rent light conditions as a reference when setting the desired
value.
RAIN SENSOR OPERATION
The electronic control unit will cause the sun shade to move
upwards as soon as the sensitive part of the rain sensor gets
wet with water as displayed when the RAIN LED lights up.
OPERATION PRINCIPLES
SW1 SW1 SW1 SW1
Step-by-step P/P + Aut Sensors User Present Sensor Test
1) Step-by-step (Dip 1 and 2 OFF)
The electronic control unit has a cyclic "Step-by-Step" logic,
whose operation depends on the type of radio control associ-
ated with.
2) Step-by-step + Aut. Sensors (Dip 1 ON and Dip 2 OFF)
The electronic control unit allows the "Step-by-Step" operation
as described above, with the addition of the automatic control of
the Wind and Rain sensors. After the activation of one of the
two sensors, once the disturbance is over, the electronic control
unit controls the downward movement of the sun shade after 5
minutes.
3) Manually-controlled (Dip 1 OFF and Dip 2 ON)
Using the radio control the “User present” operating mode can
be obtained, i.e. the control must be constantly enabled so that
the blind or shutter can be moved as necessary. The movement
stops when the control is released.
4) Sensor Test (Dip 1 and 2 ON)
The electronic control unit allows to check the sensor operation
and the correct rotation direction upon installation; we advise
that you place the shade in intermediate position in order to ver-
ify the confirmation movements during the tests.
Warning: after you have tested the sensors, restore the Dip 1
and 2 in the desired operation mode.
GB

2 www.quikoitaly.com
Anemometer : manually turn the Anemometer blades; at the
same time, the control unit will cause an upward movement
lasting 5 seconds.
Sun sensor : turn the VR1 trimmer as far as possible in a
clockwise direction (in the + position); at the same time, the
control unit will cause the SUN LED to light up and there will be
a downward movement lasting 5 seconds. Turn the VR1 trim-
mer in an anticlockwise direction (in the – position); at the same
time, the control unit will cause the SUN LED to switch off and
there will be an upward movement lasting 5 seconds.
Rain sensor : get the sensitive part of the Rain Sensor wet; at
the same time, the control unit will cause the RAIN LED to light
up and there will be an upward movement lasting 5 seconds.
When you have completed the test, make sure you have dried
the sensitive part of the rain sensor before using the control unit
in the normal operation mode.
PROGRAMMING BUTTONS AND INDICATOR LEDS
SEL button: selects the type of function to store; selection is
indicated by the LED flashing. The desired function can be se-
lected by pressing the button repeatedly. The selected function
remains active for 15 seconds (flashing LED) following which
the control unit returns to its original status.
SET button: programmes the function that has been selected
using the SEL. Key.
Indicator LEDs
LED on: option stored.
LED off: option not stored.
Flashing LED: option selected.
---------------------- MAIN MENU -----------------
Reference LED LED Off LED On
1) CODE No code TX Pgm code
2) T. MOT. Motor time 2 minutes Pgm motor time
3) WIND SPEED Wind safety 25 km/h Pgm. Wind safety
4) SUN SENSOR Sun sensor = OFF Sun sensor = ON
5) RAIN SENSOR Rain sensor = OFF Rain sensor = ON
6) SUN Sun Presence = No Sun Presence = Yes
7) RAIN Rain Presence = No Rain Presence = Yes
8) R. HEAT R. Heat = No R. Heat = Yes
1) CODE ( Radio control programming )
Programming using a 3 button radio control from the QK-
TXTUB/ QK-TXTUB3/ QK-TXTUB6.
The control unit allows you to store the whole QK-TXTUB/ QK-
TXTUB3/ QK-TXTUB6 radio-control by programming only the
UP button.
To programme the QK-TXTUB/ QK-TXTUB3/ QK-TXTUB6 ra-
dio-control codes, follow this procedure: press the SEL key; the
CODE LED begins to flash. Press the UP key of the desired
radio control at the same time; at that moment, the CODE LED
will remain lit and programming will be complete. If all of the
possible 10 radio control codes have been stored and you re-
peat the programming operation, all indicator LEDs will start
flashing very rapidly to indicate that no new codes can be
stored.
Deleting the codes To delete all transmission codes
stored in the memory, proceed as follows: press the SEL but-
ton; the CODE LED starts flashing. Then press the SET button;
the CODE LED switches off and the procedure is complete.
2) T. MOT. ( Motor Timer Programming )
The control unit comes with a motor power supply time of two
minutes (T. MOT. LED OFF).
The motor time must be programmed when the shutter is down
and in the following way:
Press the SEL key until the T. MOT LED key flashes, then hold
down the SET key; the shutter will begin to move upwards.
Once the desired position has been reached, release the SET
key – at this very moment, the motor time will be stored and the
T. MOT LED will remain lit.
If you are using an automation which has a stop limit, we rec-
ommend that you set a time which exceeds the stop limit of the
shutter by a few seconds.
If you want unlimited motor time, perform the same program-
ming procedure, holding down the SET key for less than two
seconds; the T. MOT LED will remain lit and the unlimited time
function will be set. The operation may be repeated if a mistake
is made during programming.
3) WIND ( Wind Safety Threshold Programming )
Displaying the programmed wind threshold
The wind safety threshold may be displayed in the following
way: use the SEL key to navigate to the WIND LED position;
the LED will double-flash the same number of times as the
stored wind safety threshold (each WIND LED double-flash cor-
responds to an increase of 5 km/h), (for example: 5 WIND LED
flashes = 25 km/h).
Wind safety threshold selection from 5 to 40 km/h
The control unit comes with a default wind safety threshold set-
ting of 25 km/h (WIND LED OFF).
The wind safety threshold may be programmed in the following
way: use the SEL key to navigate to WIND LED, then press the
SET key to start the programming procedure: At the same time
the WIND LED will begin to double-flash (each double-flash of
the WIND LED corresponds to an increase of 5 km/h); press
the SET key once the desired threshold has been reached – at
this moment, the selected value will be stored and the WIND
LED will remain lit (for example: 5 WIND LED double-flashes =
25 km/h).
The operation may be repeated if a mistake is made during
programming.
4) SUN SENSOR ( Sun Sensor ON/OFF )
Enabling the Sun Sensor
The control unit comes with the Sun Sensor disabled (SUN
SENSOR LED OFF).
The Sun Sensor may be enabled in the following way: press the
SEL key until the SUN SENSOR LED flashes, then press the
SET key briefly; at this moment the SUN SENSOR LED re-
mains lit and the Sun Sensor will be enabled. Repeat the op-
eration to disable the Sun Sensor.
Enabling the Sun Sensor using a 3-button radio control
(QK-TXTUB/ QK-TXTUB3/ QK-TXTUB6):
The Sun Sensor may be enabled in the following way: hold
down the (+) key on the radio control that was programmed
previously for 5 seconds; at the same time the control unit will
cause the shutter to move Up/Down for 1 second to confirm
that the Sun Sensor has been enabled, and the SUN SENSOR
LED will remain lit. Repeat the operation to disable the Sun
Sensor by following the same procedure, but instead holding
down the (-) key for 5 seconds.
5) RAIN SENSOR ( Rain Sensor ON/OFF )
Disabling the Rain Sensor
The control unit comes with the Rain Sensor enabled (RAIN
SENSOR LED ON).
The Rain Sensor may be disabled in the following way: press
the SEL key until the RAIN SENSOR LED flashes, then press
the SET key briefly; at this moment the RAIN SENSOR LED
switches off and the Rain Sensor will be disabled. You can re-
peat the operation to enable the Rain Sensor.

3 www.quikoitaly.com
EXTENDED MENU
The control unit is supplied by the manufacturer with the option
of selecting only the functions listed in the main menu.
To enable the functions of the extended menu proceed as fol-
lows: press the SET key and hold for 5 seconds; the SUN,
RAIN and R. HEAT LEDs will flash and the user has 30 sec-
onds within which to select the functions of the extended menu
using the SEL and SET keys. After another 30 seconds the
control unit returns to the main menu.
---------------------- EXTENDED MENU -----------------
Reference LED LED Off LED On
A) CODE remote PGM = OFF remote PGM = ON
B) T. MOT. Aut. movement lock = OFF Aut. movement lock = ON
C) WIND SPEED Safety upward = OFF Safety upward = ON
D) SUN SENSOR RAIN inversion = OFF RAIN inversion = ON
E) RAIN SENSOR Aut. movements 5 min. Aut. Movements 10 min.
C) SUN Flashing beacon ON/OFF
C) RAIN Flashing beacon ON/OFF
G) R. HEAT Flashing beacon ON/OFF
A) CODE
(Remote programming of radio control):
The control unit allows the transmission code to be pro-
grammed by remote, without using the SEL key.
To programme the transmission code remotely, proceed as fol-
lows: send the radio control code continuously for more than 10
seconds and the control unit will enter the programming mode
as described above for the CODE LED in the main menu.
The control unit is supplied by the manufacturer with remote
programming of the transmission code not enabled; to enable
the function proceed as follows: check that the extended menu
is enabled (SUN, RAIN and R. HEAT LEDs flash), using the
“SEL” key navigate to CODE LED when flashing and press the
“SET” key: the CODE LED lights up permanently and pro-
gramming is completed. Repeat the operation to restore the
previous configuration.
B) T. MOT. (Automatic movement lock):
The control unit enables the prevention of Automatic move-
ments (Up / Down sun blind movements on the Sun Sensor
command or Automatic Sensors function), so that if a Stop
command is sent from a radio control during the movement, the
control unit momentarily locks the Automatic movements until a
new Up or Down command is sent. The control unit is supplied
by the manufacturer with the Automatic Movement Lock dis-
abled; to enable the function proceed as follows: check that the
extended menu is enabled (SUN, RAIN and R. HEAT LEDs
flash), using the “SEL” key navigate to T. MOT. LED when
flashing and press the “SET” key: the T. MOT. LED lights up
permanently and programming is completed. Repeat the opera-
tion to restore the previous configuration.
C) WIND ( Safety Upward Movement ) :
The control unit is supplied by the manufacturer with the Safety
upward movement function disabled; if you wish to enable the
function, in such a way that after 12 hours of inactivity of the
Wind Sensor the control unit automatically control the safety
upward movement, proceed as follows: check that the extended
menu is enabled (SUN, RAIN and R. HEAT LEDs flash), using
the “SEL” key navigate to WIND LED when flashing and press
the “SET” key: the WIND LED lights up permanently and pro-
gramming is completed. Repeat the operation to restore the
previous configuration.
D) SUN SENSOR ( Rain control movement inversion ) :
The control unit is supplied by the manufacturer with the Rain
Control = Upward Movement Control association, that is to say
when the rain sensor detects the rain, the control unit controls
the upward movement. If you wish that the control unit controls
the downward movement when rain is detected by the rain sen-
sor, proceed as follows: check that the extended menu is en-
abled (SUN, RAIN and R. HEAT LEDs flash), using the “SEL”
key navigate to SUN SENSOR LED when flashing and press
the “SET” key: the SUN SENSOR LED lights up permanently
and programming is completed. Repeat the operation to restore
the previous configuration.
E) RAIN SENSOR (Automatic sensor action Time) :
The control unit is supplied by the manufacturer with the Auto-
matic sensor action Time of 4 minutes; if you wish to set 10
minutes to reduce the motor movements, proceed as follows:
check that the extended menu is enabled (SUN, RAIN and R.
HEAT LEDs flash), using the “SEL” key navigate to RAIN
SENSOR LED when flashing and press the “SET” key: the
RAIN SENSOR LED lights up permanently and programming is
completed. Repeat the operation to restore the previous con-
figuration.
RESET
To reset the default configuration of the control unit, press the
SEL and SET buttons simultaneously; all indicator LEDs will
switch on and then off again immediately.

4 www.quikoitaly.com
FOR THE USER -IMPORTANT
- The device should not be used by children or by individuals
with reduced physical or psychological abilities unless supervi-
sion is provided or instruction given on how to operate it.
- Do not let children play with the device; keep radio controls
out of their reach.
- CAUTION: Keep this instruction manual in a safe place and
adhere to the important safety instructions contained within it.
Non-adherence to these instructions may lead to property dam-
age and serious accidents.
- Examine the system frequently to check for any signs of dam-
age. Do not use the device if it needs to be repaired.
Warning
All operations which require the casing to be opened (such as
wire connection, programming, etc.) must be carried out during
installation, by skilled staff only. For any other procedure which
requires the casing to be opened again (re-programming, re-
pairs or site modifications), please contact the technical assis-
tance service.
QUIKO hereby declares that the product:
QK-CE220WRL
conform to the specifications in the Directives R&TTE
99/5/EC, EMC 2004/108/EC, LVD 2006/95/EC.
FOR THE INSTALLER –IMPORTANT
- The QK-CE220WRL control unit must be permanently con-
nected to the power supply network and is not equipped with
any type of 230 V a/c electric line sectioning device. The in-
staller is responsible for installing a sectioning device in the
system. An omnipolar switch with overheating category III
must be installed. It must be positioned in such a way that it is
protected against accidental closures.
- For connections (power supply and outlet contact) we rec-
ommend the use of flexible wires with an insulating sheath in
harmonised polychloroprene (H05RN-F). The wires should
have a minimum cross-section of 0.75 mm2.
- Fasten the connection cables using the cable clamp sup-
plied with the product kit.
- Handle the control unit with care during the installation
process
and make sure that all components are properly assem-
bled. Pay particular attention to the ceramic plate and the flat
connection cable. When closing the box again, it must fold
back on itself normally.
- It is very important to establish an exact location so that the
product is exposed to weather conditions it can control.
- Fix the device to the wall using the screws and raw plugs
supplied with the product, in the correct position (see figure
below).
- Make sure that the control unit remains tilted at approxi-
mately 45 degrees (Fixing area at the top, round end of the
box at the bottom).
- Do not paint or varnish the sensitive surface of the control
unit.
- The dirt which accumulates on the surface of the rain sen-
sor restricts its sensitivity: we therefore recommend that it is
cleaned once or twice a year using a damp cloth, after the
electricity supply has been disconnected.
- Connect the earth wire of the motor to the earth wire of the
electrical system using the special terminal on the control unit,
as illustrated in the connection diagram.
−For the radio receiver to operate correctly when two or more
control units are used, we recommend that you install the
devices at least 3 metres away from each other.
QUIKO ITALY
Via Seccalegno 19
36040 Sossano (Vi) Italy
Tel + 39 0444 785513
Fax +39 0444 782371
www.quikoitaly.com
Other quiko Control Unit manuals
Popular Control Unit manuals by other brands

ICP DAS USA
ICP DAS USA I-8088W API Reference Manual

elsner elektronik
elsner elektronik KNX A3-B2 Installation and adjustment

Siemens
Siemens SINAMICS RAILCTRL Function manual

BS&B
BS&B NACIONAL 3-5111 Instruction and maintenance manual

DeZurik
DeZurik APCO CAC-8000 Instruction

Dynojet
Dynojet Power Commander III USB installation instructions

Goetze
Goetze 851 Assembly instructions

LOGICDATA
LOGICDATA SMARTneo-2G manual

BHI
BHI NEDSP1061 Fitting instructions

Singer Valve
Singer Valve 106-SC Installation, operating and maintenance instructions

BERMAD
BERMAD C15 Installation, operation and maintenance manual

Flavor Burst
Flavor Burst ADPT TY80S-FCB2 Installation