RAB XDIM User manual

IMPORTANT
INSTRUCTIONS
Phase Dimmer
TO PREVENT ELECTRICAL SHOCK, POWER SHOULD BE TURNED OFF AT THE FUSE BOX BEFORE INSTALLATION.
●To avoid risk of fire and electrical shock, products shall be installed in accordance with electrical code and regulations.
●The product shall be used together with an air-break switch.
●Cut off the power at the circuit breaker or fuse before installation.
●If you’re not clear about any content of the instructions, please consult the licensed electrician.
●Switch to the leading mode when the inductive load is used.
●Product should only be used with compatible dimmable LED, CFL, incandescent or halogen products.
●When connecting multiple products with a single dimmer, do not mix product types. All products shall be either dimmable
LED, CFL or incandescent products. Using the same type of products will enhance dimmer performance.
●This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may
not cause harmful interference, and (2) This device must accept any interference received, including interference that may
cause undesired operation.
●To avoid the risk of overheating and possible damage to the equipment, do not use the product to control the receptacle,
motor-operated appliance or a transformer-supplied appliance.
●After installing the dimmer, it’s recommended to set the minimum brightness level to make bulbs turn on immediately and
the dimmer with maximum dimming range.
WARNINGS and CAUTIONS:
XDIM
WHAT'S IN THE BOX
Dimmer (1 pcs)
Jumper Wire
(1 pcs)
Mounting Screws
(2 pcs)
Base Plate
(1 pcs)
5PIN Wiring
Terminal (2 pcs)
2PIN Wiring
Terminal (3 pcs) Connection Wire (5 pcs)
Face Plate
(1 pcs)
TOOLS NEEDED
5mm Philips Screwdriver
Electrical Tape
Electrician Knife
Test Pencil
Pliers
Ruler
●
●
●
●
●
●

INSTRUCTIONS
Phase Dimmer
Off/Down Paddle
●
●
●
Turn light off: When the light is on, short press the Off/Down
Paddle once
Brightness Indicator
Note: Brightness Indicator lights will stay illuminated while circuit it powered on.
●
Quickly adjust to the lowest dim level: When the light is on or
off, press the Off/Down Paddle 2 times
●
Gradually decrease brightness: When the light is on, press and
hold the Off/Down Paddle, the brightness will gradually
decrease until the brightness reaches the minimum level or
until the Off/Down Paddle is released
To enter programming mode, press and hold the On/Up and
Off/Down paddle for 3 seconds until the indicator light flashes.
Programming Mode
LED 11
LED 10
LED 9
LED 8
LED 7
LED 6
LED 5
LED 4
LED 3
LED 2
LED 1 Power Indicator
Brightness Indicator
●
Quickly adjust brightness: When the light is on or off, press the
On/Up Paddle for 2 consecutive times
Power Indicator
On/Up Paddle
●
Turn light on: When the light is off, short press the On/Up
Paddle once
●
Continuously increase brightness: When the light is on, short
press the On/Up Paddle, the brightness increases until the
brightness reaches 100%
●
Gradually increase brightness: When the light is on, press and
hold the On/Up Paddle, the brightness will gradually increase
until the brightness reaches the minimum level or until the
On/Up is released
●
White light constant brightness: Power-on stage
BASIC OPERATION
●
Short Press: Within 0.5 seconds
•
•
Long Press: Over 0.5 seconds
Double Press: Within 1 second
Switch
●
●
F: Forward Phase Control (leading edge control mode)
●
A: Auto detect control mode
Power Cut Off Switch
●
Push in to connect to line voltage
●
Pull out to disconnect line voltage
●
R: Reverse Phase Control (training edge control mode)
Note: after dip switch adjustment, please power off and then power on again.
To set the minimum brightness/low-end trim, press the
On/Up Paddle to turn on the lights and adjust to the desired
minimum brightness. Short press the Off/Down Paddle 3
times to set.
To exit programming mode, press and hold the On/Up and
Off/Down Paddle for 3 seconds. The dimmer will automatically
exit programming mode after 1 minute without operation.
Power Indicator
Power Cut Off Switch
Brightness Indicator
Off/Down Paddle
On/Up Paddle
Switch
Status Indicator
No.
1
2
3
4
Brightness Level
Brightness Level 1
Brightness Level 2
Brightness Level 3
Brightness Level 4
5
Brightness Level 5
6
7
8
9
10
Brightness Indicator
LED 2
LED 2~LED 3
Brightness Level 9 LED 2~LED 10
LED 2~LED 4
Brightness Level 8 LED 2~LED 9
LED 2~LED 5
LED 2~LED 6
Brightness Level 6 LED 2~LED 7
Brightness Level 10 LED 2~LED 11
Brightness Level 7 LED 2~LED 8

INSTRUCTIONS
Phase Dimmer
Single-Pole
Hot
Neutral
Ground
Load
IMPORTANT NOTE: For a Single-Pole application, note that one of
the screw terminals from the old switch being removed usually is
a different color (Black) or labeled Common. Tag the wire with
electrician tape and identify as the Common (hot wire or load) in
both the dimmer wall box and Single-Pole wall box.
4. Typical Wiring (see wiring section)
5. Install and fix the dimmer:
Carefully position all wires inside the wall box, leaving enough
room to insert the dimmer housing. Secure the dimmer with the
mounting screws provided
Mounting Screws
Wall Box
Dimmer
v
Hot or Load
(see note below)
Neutral
Ground
Traveler 1
Traveler 2
3-Way
1. Warning: To avoid risk of fire and electrical shock, cut off the power
at the circuit breaker or fuse before wiring
2. Remove existing switch: Remove existing wall panel and switch
mounting screws. Carefully pull switch from wall box, identify and
remove the wires attached to the switch, then remove the switch.
Do not remove the wires from the wall at this time. (for new
installations where an existing switch does not exist, skip this step.)
Note: If the wiring layout in the wall box does not resemble any of these
configurations, consult an electrician.
3. Identify the type of circuit
INSTALLATION
INSTALLATION (cont’d)MULTI-GANG INSTALLATION DERATING
Single-Gang
Rating
500W ELV
400VA MLV
400W ELV
300VA MLV
300W ELV
200VA MLV
300 W CFL/LED/
Electronic
self-ballasted
300 W CFL/LED/
Electronic
self-ballasted
300 W CFL/LED/
Electronic
self-ballasted
120 Vac,
60 Hz,
500 W Tungsten
Double-Gang
Rating
Triple-Gang
Rating
120 Vac,
60 Hz,
400 W Tungsten
120 Vac,
60 Hz,
300 W Tungsten

INSTALLATION (cont’d)
INSTRUCTIONS
Phase Dimmer
●
Connect the face plate to the installed base plate and gently push
it until it clicks into place.
Face Plate
Base Plate
WIRING
1. Single-Pole
Wiring Scheme 1 (neutral and hot wire)
N
P LD
L
Dimmer
Hot
Neutral
Ground
Load
screw
screw
Copper
Silver screw Black screw
Brass screw
Green
Wiring Scheme 2 (hot wire only)
N
P LD
L
Dimmer
Hot
Neutral
Ground
Load
screw
screw
Copper
Silver screw Black screw
Brass screw
Green
Tagged
wire
Location
1
Dimmer
To breaker
or load
(Light(s))
To breaker
or load
(Light(s))
Copper
screw Brass
screw
Black
screw
screw
Silver
screw
Ground
(Green or Bare Copper)
N
P
L
White
LD
Screws
Base Plate
Dimmer
6. Install the wall panel
●
Place the base plate over the installed dimmer and secure
it using provided screws.
Tagged
wire
Location
1
Dimmer
To breaker
or load
(Light(s))
To breaker
or load
(Light(s))
Copper
screw Brass
screw
Black
screw
screw
Silver
screw
Ground
(Green or Bare Copper)
N
P
L
LD

Easy Answers
DIMMER-IN-0623
Cranbury, New Jersey 08512 USA
2. 3-Way (neutral and hot wire)
Wiring Scheme 3 (dimmer line side) Wiring Scheme 4 (dimmer load side)
N
P
L
LD
Common terminal
Green
Dimmer 3-Way
Switch
Hot
Neutral
Ground
Ground
Load
Jumper
Silver screw Black screw
Brass screw
screw
Copper
Hot
Neutral
Load
Ground
Jumper
Green 3-Way
Switch
Common
terminal Dimmer
Copper screw
Silver screw Black screw
Brass screw
N
P
L
LD
To breaker
or load
(Light(s))
Copper
screw Brass
screw
Black
screw
Tagged wire
Location
1 Location
2
Green
screw
Ground Jumper wire
Common
terminal
Dimmer
3-Way Switch
Screw 2Screw 1
To breaker
or load
(Light(s))
Traveler 2
Traveler 1
Green
screw
Silver
screw
Ground
(Green or Bare Copper) (Green or Bare Copper)
N
P
L
LD
White
screw
Green
screw
Green
2023
WIRING (cont’d)
INSTRUCTIONS
Phase Dimmer
3. 3-Way (hot wire only)
Wiring Scheme 5 (dimmer line side) Wiring Scheme 6 (dimmer load side)
N
P
L
LD
Common terminal
Green
Dimmer 3-Way
Switch
Hot
Neutral
Ground
Ground
Load
Jumper
Silver screw Black screw
Brass screw
screw
Copper
Hot
Neutral
Load
Ground
Jumper
Green 3-Way
Switch
Common
terminal Dimmer
Copper screw
Silver screw Black screw
Brass screw
N
P
L
LD
To breaker
or load
(Light(s))
Copper
screw Brass
screw
Black
screw
Tagged wire
Location
1 Location
2
Green
screw
Ground Jumper wire
Common
terminal
Dimmer
3-Way Switch
Screw 2Screw 1
To breaker
or load
(Light(s))
Traveler 2
Traveler 1
Green
screw
Silver
screw
Ground
(Green or Bare Copper) (Green or Bare Copper)
N
P
L
LD
screw
Green
screw
Green
Table of contents