3
Manual - AlphaBlower 2200
Table of Contents
1 Introduction......................................................................4
2 Accessories.......................................................................4
3 Technical overview...........................................................5
4 Installation........................................................................6
4.1 Intended use.............................................................6
4.2 Installation instructions............................................7
4.3 User groups ............................................................12
5 LED display & warning signals ........................................14
5.1 Green......................................................................14
5.2 Yellow + warning tone: Service interval reset........15
5.3 Red + warning tone: Cleaning ................................15
6 Symbols ..........................................................................17
7 Declaration of Conformity..............................................18
8 Warranty ........................................................................19
9 Support and Contact ......................................................20
9.1 Troubleshooting/FAQ.............................................20
9.2 Contact Us ..............................................................20

4
Manual –AlphaBlower 2200
1 Introduction
The AlphaBlower 2200 is suitable for installation in a vacuum
pipe system for pumping radon, to reduce radon
contamination in buildings.
2 Accessories
The scope of delivery of the AlphaBlower 2200s includes the
following individual parts:
AlphaBlower 2200
Wall mount
Power supply unit
Cable

5
Manual - AlphaBlower 2200
Connector plug
Screws
Wall mounting material
3 Technical overview
Suction unit
Radon
Voltage
1-phase safety transformer
120 VA / 27 VAC
230 V / 50 Hz
Power
70 W
Max. Vacuum
2200 Pa
Max. Flow rate
130 m³/h
Overvoltage protection
--
Noise level at 1m distance
<40 dB (A)
Dimensions LxWxH
360 x 320 x 200 mm

6
Manual –AlphaBlower 2200
4 Installation
Read these instructions and the enclosed safety
notes completely before commissioning and working
with the device.
Keep these instructions in a place where they are accessible to
all users.
4.1 Intended use
The AlphaBlower 2200 must be placed or mounted on
a stable and solid location in the building.
To reduce condensation problems, the AlphaBlower
2200 and the corresponding piping should be mounted
in heated areas, or the piping must be insulated. Care
must be taken to prevent condensate from running
back into the unit. Condensate running back will
damage the AlphaBlower 2200.
The AlphaBlower 2200 may only be used at room
temperature and indoors. The device must be
protected from excessive moisture and direct sunlight.
The AlphaBlower 2200 must be installed by a specialist
company or a person with the appropriate expertise.

7
Manual - AlphaBlower 2200
4.2 Installation instructions
1. Fix the wall bracket to the wall with four screws.
2. Insert the AlphaBlower 2200 into the holder
4x

8
Manual –AlphaBlower 2200
3. Fix the AlphaBlower 2200 in the holder with 4 screws
4. Installation radon well
4x
Ø 40-60
cm

9
Manual - AlphaBlower 2200
5. Wiring
The mains cable may only be plugged into the mains sockets or
adapters approved for this purpose. Check that the mains
voltage matches the connected load of the aspirator.
Do not use the cable for purposes for which it is not
intended.
Following the installation, the radon concentration must be
measured and a maintenance cycle must be set.

10
Manual –AlphaBlower 2200
6. Possible design variant

11
Manual - AlphaBlower 2200
Delivery rate(m3/h)
Fan-
characterist
ic
Vacuum (Pa)
7. Set
By pressing the Plus key, the air volume flow can be increased.
The air volume flow can be reduced by pressing the Minus key.
m³/h
ON
-
-
+
-
+

12
Manual –AlphaBlower 2200
4.3 User groups
Due to varying degrees of risk and hazard potential, some work
steps may only be performed by trained specialists.
Work step
User groups
Installation and
assembly of the unit
Qualified personnel with
technical training
Technical trainees under the
guidance and supervision of a
qualified specialist
Electrical connection
Replacement of
electrical spare parts
Electrician
Technical trainees under the
guidance and supervision of a
trained specialist
Determination of
maintenance intervals
Specialist

13
Manual - AlphaBlower 2200
Improper connection of the device may result in injury
from electric shock and the device may be damaged.
If the device is defective, active conductors may be
exposed or the protective conductor may be without
function.
Repairs may only be carried out by a recognized
specialist.
If the connecting cable is damaged, it must be replaced
by a specially prepared connecting cable.
Faulty installation can lead to increased radon
concentration.
The installation must be tight. Seal screw connections
and cracks in the base plate.
Improper use can lead to respiratory problems,
suffocation, poisoning or cancer.
Exhaust air must not be directed into used areas, e.g.
near a terrace. Minimum distance to the nearest
window must be 2 or more meters. Observe wind
direction.

14
Manual –AlphaBlower 2200
5 LED display & warning signals
The control panel of the AlphaBlower 2200s provides status
information via 3 LEDs.
5.1 Green
The green LED indicates that
power is being supplied to
the AlphaBlower 2200.
+
-

15
Manual - AlphaBlower 2200
5.2 Yellow + warning tone: Service interval
reset
The yellow LED with warning
tone indicates that the
maximum runtime for the
stored service interval has
been reached.
To reset the service interval,
the + and - keys must be
pressed simultaneously while
switching on the AlphaBlower
2200s until the red and yellow
LEDs light up and the warning
tone sounds.
After resetting the service interval time, the new time interval
starts counting down from 9000h.
5.3 Red + warning tone: Cleaning
The red LED with warning
tone indicates that the air
supply or air discharge is
blocked. The AlphaBlower
2200 must be cleaned.
After 5 minutes, the aspirator is switched off if the alarm has
not been terminated.
+
-

16
Manual –AlphaBlower 2200
Disconnect the plug from the socket before carrying
out any work on the device.
Remove the
blockage in the air
supply and / or air
exhaust.
When cleaning the piping system/suction chamber, an
increased pollutant load of the ambient air is to be
expected.
If the suction performance is impaired by deposits in the
piping system, contaminated parts must be replaced. Only
original spare parts are to be used for this purpose.
Repairs may only be carried out by recognized
specialists. For more details, refer to chapter 5.3 User
groups.
Finally, reset the alarm by pressing the +
key for 5 seconds. The green LED lights
up.
+

17
Manual - AlphaBlower 2200
6 Symbols
Attention
Read the operating instructions!
Always disconnect the plug from the socket
before carrying out any work on the device.
CE conformity mark
Fuse
Safety transformer
Do not dispose of power tools in household
waste! According to the European Directive
2012/19/EU on waste electrical and
electronic equipment and its
implementation in national law, used
electrical tools must be collected
separately and recycled in an
environmentally friendly manner. Dirty
filters must be treated as hazardous waste.
Dispose of replaced device parts, filters or
old devices in accordance with the the
regulations of your country.

18
Manual –AlphaBlower 2200
7 Declaration of Conformity
We declare that the designated products comply with the
provisions of the following directives:
2014/30/EU, 2014/35/EU, 2011/65/EU
Applied harmonized standards:
DIN EN 60335-1: 2012-10
DIN EN 60335-2-45: 2012-08
DIN EN 62233: 2008-11 / 2009-04
DIN EN 55014-1: 2012-05
DIN EN 55014-2: 2009-06
DIN EN 61000-3-2: 2015-03
DIN EN 61000-3-3: 2014+03
DIN EN 50581:2013-02
Wittislingen, 2016-02-24

19
Manual - AlphaBlower 2200
8 Warranty
The limited warranty (1 year) applies to the AlphaBlower
2200 purchased from RadonTec GmbH or authorized dealers.
This covers defects in material or workmanship under normal
use for a period of one year from the date of receipt of the
product. Contamination due to dirt or improper use is not
covered by the warranty. During the warranty period, the
product will be repaired or replaced at no charge.
*Exclusions:
This warranty does not cover damage caused by abuse,
neglect or misuse. This includes damage caused by drops,
impacts or penetrations. It is also void if the product has been
repaired or altered by another EIC Inc.
To obtain this warranty service, please contact us at:

20
Manual –AlphaBlower 2200
9 Support and Contact
9.1 Troubleshooting/FAQ
You will find answers to the most frequently asked questions
on our website:
https://www.radontec.de
9.2 Contact Us
Should you have any further questions or require further help
and technical support, please do not hesitate to contact us.
RadonTec GmbH
Hauptstraße 5
89426 Wittislingen - Germany
Tel: (+49) 9076 - 919 98 35
Website: radontec.de
Shop: radonshop.com
This manual suits for next models
1
Table of contents
Other RadonTec Fan manuals
Popular Fan manuals by other brands

HAEGER
HAEGER SF-16W.006A User instructions

LUCCI Air
LUCCI Air AIRFUSION FLUSSO manual

Premium levella
Premium levella PFT424R user manual

iLiving
iLiving ILG937 Operating instructions & parts manual

Viking Range
Viking Range CVDD5300 Use & installation guide

Fanimation
Fanimation Andover FP5220 Series owner's manual