Rahrbach 7150 Series User manual

Verschlusstechnik
RAHRBACH
Instr ction for Pin Locking Mechanism 7150
Note:
Please also read the assembly instructions for this product
Inst uctions ega ding Rah bach Se ies 7150 bolt closu e
The information concerning the above article contained on these pages and on other data
carriers is based exclusively on a test carried out with this product and article. The infor-
mation given in the catalogue and on the Internet only serves to describe the product and
should not be understood as indicating warranted or guaranteed characteristics in the
legal sense. Information regarding product lifetime as well as definition of technical data is
provided in accordance with tests carried out internally at Rahrbach following generally re-
cognised regulations and/or standards.
The knowledge and information gained from such tests are unique and can change within
the framework of every application. Therefore the information which is published should
only be understood as a general guide. Safety regulations with regard to the specific loca-
tion where the product is to be used must be investigated in advance by the customer in
order that he may check the suitability of the product for the particular application himself.
We also recommend testing the product under the actual conditions in which it is to be
used in order to determine suitability.
Improper use, storage, maintenance, repair and/or actions or circumstances which may in-
fluence the product, or unsuitable further processing or treatment can lead to faults and
damage when the product is in use. We draw you attention to the fact that Rahrbach
GmbH does not accept any liability, guarantee or responsibility if our products are
changed, unless the change has been expressly approved by us for the specific case. If
there should be any questions, problems or unusual product behaviour or features when
the product is in use in the field, the door manufacturer or Rahrbach should be contacted
directly.
Use in acco dance with the egulations
The bolt closure serves to prevent unauthorised opening of the sliding door from outside.
The Rahrbach bolt closure is only used for industrial applications on hand-operated sliding
doors, e.g. sliding doors of different sizes used for refrigeration rooms.
Operating Conditions:
Temperature: up to 50°C - down to -25°C without heating system acceptable*
> - 25 °C only with heating system
Furthermore,please note the described indices mentioned in our mounting instructions
under "warning"!
Imp ope use
It is not permitted or not appropriate to use the bolt closure on fire doors, escape doors
and hatches, marked escape routes, electrically-operated sliding doors (except for Rahr-
bach product series 7150 with Reed Switch) and in the area of vehicle container design
and construction.
* is currently in validation of RAHRBACH test standart without heating system
Gene al Advice:
After installing the bolt closure always check correct function with 2 people (one person
must be inside and one must be inside the refrigeration room).
For safety reasons, the user must be instructed in the use of the closure and should con-
firm in writing that the instruction has been received. Particular attention should be drawn
to the fact that when the door is opened from the inside the sliding bolt is pushed through
to the outside up to the stop. If the bolt is only partially pushed to the outside, the inside
release button can strike the frame when the door is opened and be damaged.
The key must be removed after every closing operation.
The luminous labels (pictograms) explain the use of the bolt closure. If these labels are
damaged or removed, a person wishing to operate the closure in the dark may not know
what to do and be reduced to experimentation. The pictograms must be located near the
assembled bolt closure.
Please read the following sections.
Secu ity Advice:
The use of the bolt closure is only permitted, when it is guaranteed, that the bolt is not
blocked by freezing or its way is limited in the normal way.
If it is not able to preclude the possibility of thawing and refreezing because of various
temperature conditions, it has to be prevented with a technical solution e.g. an according
heating system or in an acceptable way with greasing with silicone grease.
Cleaning / Maintenance
The bolt closure is not maintenance-free.
The sliding bolt is greased with silicon grease against freezing. This grease may not be re-
moved. Regrease if necessary.
The bolt closure and the labels should be regularly checked to make sure that they are in
good condition and must be replaced immediately in case of damage. Any defects or dis-
turbances to operation must be repaired immediately or the item must be sent to the ma-
nufacturer for repair.
The customer is not permitted to undertake repairs himself.
The function of the closure must be checked at regular intervals at a temperature of max.
minus degrees.
For cleaning of the bolt closure we recommend a mild cleaning agent, such as for exam-
ple soap and warm water. Other aggressive or abrasive cleaners must not be used.
Note: Clean the bolt at temperatures above freezing.
The cylinder may only be replaced by specialist or trained personnel.
Technical changes can lead to a change in liability risk.
Every manufacturer is therfore pleased to prove the suitability of this bolt closure on his
own. Distributor have to forward this instruction to the buyer. technical data sheet for locks
and closures.

Verschlusstechnik
RAHRBACH
X
58 mm
type of closure: Pin ocking Mechanisms
article- No.: 7150
area of application cold store sliding doors
1. left or right opening: yes
2. corrosion: all components corrosion resistant
3. fixings: sheet metal screws
4. anti-theft device: yes
5. detection of locking position: optional with reed relais
8. materials:
housing: plastic
bolt: plastic
nuts: plastic
button: plastic
profil cylinder: brass
screws: stainless steel
sealing rubber sealing
grease: unisilicon
9. colors: black
Note:
Also ead the assembly inst uctions and any othe inst uctions. Dimension X can be supplied in 80, 100, 120, 140 and 160mm
Door strengths from 70 mm by application of two spacer possibly
Intermediate sizes on request.
Technical Data Sheet for lock

Verschlusstechnik
RAHRBACH
1300 - 1600 mm
Position “closed”
frame
Mo nting Instr ction for Pin Locking Mechanisms
1.Pin locking mechanisms in locked condition prevent the sliding door from being
shifted open from outside. From inside, the sliding door can always be opened
after actuating the emergency opening mechanism. The distance between door
and frame must be 20 mm min, and 35 mm max. (sealing thickness).
Series 7150
Follow Technical Data Sheet and Instructions
2. For this purpose, the pin locking mechanism is installed
in a convenient height adjacent to the rear panel of the
door. Borehole diameter 60 mm
Position “open”
frame
door
door
door sliding direction
door sliding direction
door sliding direction

Verschlusstechnik
RAHRBACH
3 mm
10 mm
60 mm
Mo nting Instr ction for Pin Locking Mechanisms
Series 7150
Follow Technical Data Sheet and Instructions
Do not remove any self adhesive tape!
3. On the outer side, file a recess of 10 mm height and approx. 3 mm
width into the sheet, in 3-o'clock position, to accept the little plate on the
housing (see arrow) as a torsion safety mechanism. Do not remove any
self-adhesive tape covers from the housing!
4.Push the pin locking mechanism through the door from
outside, making sure to position the little plate (detent)
correctly.
View from outside
detent

Verschlusstechnik
RAHRBACH
Mo nting Instr ction for Pin Locking Mechanisms
Series 7150
Follow Technical Data Sheet and Instructions
5.Screw the nut onto the housing from inside
6.Mark three holes of nuts on the door, centre-punch
and drill 3mm holes. Insert 3.9 mm plate screws sup-
plied as a fixation of the nut, thereby, the pin locking
mechanism is secured against disassembly.
view from inside
view from inside
7. Put the inner sealing onto the fixed nut
8. Clean and degrease the door panel around the
lock and paste the warning sticker on it.

Verschlusstechnik
RAHRBACH
Mo nting Instr ction for Pin Locking Mechanisms
Series 7150
Follow Technical Data Sheet and Instructions
9. Insert the key into the closed door and rotate it anti-clockwise by about
180° (1). Now the pin can be pushed inside (2), turn the key into vertical
position again and take it out. So the door is safeguarded against inad-
vertent opening. Do not turn the key violently, but always pull it out!
10. If necessary, to open from inside (emergency release) push the
knob as illustrated on the lighted label.
view from insideview from outside

Verschlusstechnik
RAHRBACH
Mo nting Instr ction for Pin Locking Mechanisms
Series 7150
Follow Technical Data Sheet and Instructions
- disassemble pin lock
- use 2,5mm Inbuskey to disassemble M5 threaded pin
- exchange cylinder (e.g. towards cylinder out of a master-key-system)
- retain cylinder again with threaded pin
Regarding the door thickness use the optional 5mm spa-
cer for intermediate sizes.
E.G for door thickness 70mm use a 80mm pin lock in
combination with two spacer. Max. two spacer permitted.
Door design with 5mm spacerExchange Profil-Cylinder

Verschlusstechnik
RAHRBACH
Mo nting Instr ction for Pin Locking Mechanisms
Series 7150
Follow Technical Data Sheet and Instructions
Connect Reed Relais as shown in the datasheet
Optional Reed relais function
Other Rahrbach Lock manuals