rako RLED Series User manual

House address
= 128+16=144
Room address
= 32+4=36.
Rako RLED Series Dimmable LED Driver Modules – Installation, Programming and Operating Instructions.
The Rako RLED series of modules provide constant
current dimmable output suitable for use with
350mA, 600mA and 700mA LED modules.
Input supply is direct from 230v ac supply.
Brightness is controlled by Rako scene-sender
panels transmitting Rakom encoded radio signals.
Fig 1.
Front View of Components
Installation
Before commencing installation of a Rako dimmer
module first read this instruction manual carefully.
Rako Controls Ltd accepts no responsibility for any
damage or injury caused by incorrect installation of
a Rako product.
Installation should only be carried out by a
competent electrician.
Never attempt to connect a Rako dimmer or
remove the terminal covers without first isolating
the circuit at the fuse/MCB board.
The circuit supplying a Rako dimmer should always
be protected by either a 5A fuse or 6A MCB.
Rako RD dimmer modules should be mounted in
areas that are adequately ventilated, dry and
outside of any enclosed metal casings. Wherever
possible the modules should be securely fixed using
the mounting holes provided. The mounting holes
are blanked off when supplied but are designed so
that a woodscrew will easily cut through without
the need for drilling.
Whilst the Rako dimmer modules are designed to
be completely maintenance free the units should
be mounted in a position where access can be
gained should there be a fault or re-addressing of
the unit be necessary (see ‘Set-up and
Addressing’).
Permissible loading.
350mA, 600mA or 700mA maximum output selectable
by jumper.
Maximum output voltage is 30V DC.
For 1W White LED’s. Maximum loading = 9 x LED in
series. Set Jumper to 350mA setting.
Jumper A OFF, Jumper B OFF.
For 2W White LED’s. Maximum loading = 9 x LED in
series. Set Jumper to 600mA setting.
Jumper A ON, Jumper B OFF.
For 3W White LED’s. Maximum loading = 6 x LED in
series. Set jumper to 700mA setting.
Jumper A ON, Jumper B ON
To ensure that the cable clamping operates
satisfactorily the cabling both supplying the dimmer
and to the load should be a minimum of 0.5mm2with
double safety insulation and the wires should be
stripped to ensure that the cable bar within the
terminal cover clamps firmly on both sets of
insulation.
To install a Rako dimmer module isolate the supply
then remove the Terminal Covers (see Fig.1) giving
access to the supply/load terminals. The necessary
connections are indicated on the label on the dimmer
housing. The notation is as follows:
L –Live wire from the supply (normally coloured
Brown)
N –Neutral (normally coloured Blue)
Once the supply and load cables are connected ensure
that the terminal covers are replaced and securely
fastened, clamping the cable correctly as detailed
above, before powering the unit.
Rako dimmer modules are not designed for loop
in/loop out connections. Should it be necessary to
loop the supply on to further fittings then a junction
box should be connected in circuit to facilitate this.
With the supply and load connected and prior to
switching on the supply ensure that the terminal
covers are fitted and that they are securely clamping
the cables. It is important to ensure that the
protective inserts (see Fig.1) are fitted and located
securely, both in the terminal cover and over the
supply and load cables. The protective inserts provide
important protection against the risk of electric shock
from conductive objects forced down the side of the
cables.
Set-up and Addressing
Before any lighting scenes can be programmed (see
the wall panel or handheld instruction manual) the
receivers need to be addressed.
To avoid interference between rooms or neighbouring
installations a Rako system should be set to an
address other than the factory default of House 1
Room 4. The preferred addressing method is to select
a logical House address number for the project,
separate Room addresses for each room within the
house and then sequential Channel numbers for each
receiver within each room (see Fig.5) i.e. Channel 1
for the 1st receiver, Channel 2 for the 2nd etc. The
House and Room addresses are set using the DIP
switches on the back of a Rako controller (see Fig.4)
and the Channel address is set by ‘stepping’ through
the channel numbers with a panel in programming
mode (see Step 3 overleaf) and then sending this
number (along with the House and Room address) to
a receiver (Step 5).
Setting the address switches.
Each Rako transmitter has two, 8 way banks of
switches for setting its address. The two sets of
switches allow the user to choose from 256 house
addresses and 256 room addresses. To set the
address, unclip the rear cover whereupon the banks of
switches will be now become visible. To set an
address, use a small terminal screwdriver or similar
device and carefully move some of the switches into
the ‘ON’ position. Addressing uses binary encoding
and the value of the switches is shown below.
Note: Any control panels set with the same address
will act as two or multi way controls.
ON
128
64
32
16
8
4
2
1
BINARY VALUE
ON
HOUSE
ROOM
128
64
32
16
8
4
2
1
BINARY VALUE
Fig 4.
Addressing Switches
144
Ch anne l 1
Channel 2
Ho use 1 44
Ro o m 6
Ch a nnel 1
Channel 2
Ro o m 5
House 144
Fig 5.
Addressing Example
Notes on addressing.
A dimmer will not receive an address of House 0 (All
switches set to off)
A dimmer will respond to, but not receive an address
of Room 0 (All switches set to off). This Room 0
address is used for ‘Master House’ control
A dimmer cannot be set to channel 0.
To program a lighting scene see Wall panel or Hand
held manual.
Care and maintenance
A Rako dimmer module contains no user serviceable
parts. Should for any reason you need to contact us
please contact us via our website
www.rakocontrols.com or by phoning our customer
help line on 01634 226666.
Protective
Insert
Supply/Load
Terminals
Terminal
Cover
Fixing Screws
230v AC
Connection
terminals
Mounting
Holes
Clamping
Bar
LED Load
Connection
terminals
Output current
select Jumpers
A
B
A
B

Is there
another receiver in
the room to be
addressed
Initial Addressing of a Rako Receiver Module
Note:
In the following procedure both the controllers (wallpanels and hand held remotes) and the receivers have an automatic time out after approximately 3 minutes when
in programming or set-up mode. This feature avoids the possibility of either being left permanently in programming or set-up mode. This may cause confusion if
either the controller or receiver times out before the procedure is complete. It is worth becoming familiar with the procedures before starting the addressing procedure.
If at any time it is necessary to start again the controllers can be returned to normal mode by pressing the ‘Off’ button and the receivers by resetting the electrical supply.
Note:
A Rako panel will enter programming mode at Channel 0.
It is not possible to give a receiver an address of Channel 0 but
this gives a consistent starting point.
always
Go to the receiver to be addressed
Step 1
Set address
switches on
controller
Pick an House address from 1-255
(keep same address for all panels in house)
Select Room addresses from 1-255 for
room (Room 0 is master house control)
each
Step 2
Put controller into
programming mode
by pressing and holding
a scene button both
raise and lowe r buttons
together. After 5 seconds
the red LED on the panel
star ts to fl ash. Th e p ane l
is now i n p rog ram ming
mode. Release the buttons
and
TIP
Press the
scene button first
Hold the
magnet against casing at point indicated
on the label until LED illuminates and keep the
magnet held with the LED on until it starts to
flash. Then remove magnet. Module is now in
set-up mode.
If a receiver is already addressed to a
controller (for example a receiver is addressed to
the controller but with the wrong channel number)
then the LED will be flashing as soon as the panel
is put into programming mode. It will, however,
still be possible to re-address this receiver using
the magnet as normal.
Note:
Step 4
Note:
When in programming mode the buttons have functions as
detailed in table 1.
Press button 1 once to step up one channel.
If this is the desired channel i.e. Channel 1(for the 1st receiver)
then go to Step 4. If not, press button 1 again to step up to
channel 2 (for the 2nd receiver), again to step to channel 3 etc,
until the d esired channel number is reached (maximum = 15).
It is this channel number (along with the House and Room address)
that is sent to the receiver in Step 5. If at any point it is necessary to
step down a channel, press button 2 once.
Step 3
If some receivers are already addressed to a the wall panel then they
will ‘flash’ their connected lamps as their channel number is reached during
the stepping procedure, this allows the user to ‘identify’ which channel numbers
are already taken. To add a new receiver to an existing installation step up through
the channels until a channel number is reached where no receiver flashes a load, this is
then an available channel. If at any point there is uncertainty as to whether a receiver
actually flashed its load then button 3 will flash the load but without stepping up or
down a channel. If all of the loads flash then this indicates that the current address is
Channel 0.
Note: If it is not possible to see the connected lamps flashing when stepping through
the channels it is possible to tell from the LEDs in the receivers which will momentarily
go solid when their channel address is reached.
Step 5
Press button 3
to send the ident
of the channel
se lec ted in step 3 .
Receiver automatically
re turns to n orm al mod e
(blue LED goes out)
while controller remains
in programming mode
(red LED keeps flashing)
Step 6
Press Off button
to exit controller
from programming
mode
Button
1
2
3
4
Off
Action
Step up one channel and ident
Step down one channel and ident
Ident
No action
Exit programming
TA B L E 1
Is the
controller
still in programming
mode (red LED
flashing)
Note
YE S
NO
YE S
NO
Other rako Control Unit manuals