BEFORE USE ....
Thank you for choosing us. Before use, please check con-
tents of the package you received as outlined below.
If you have any problems or questions with the product,
please contact our sales office or representatives.
■PACKAGE INCLUDES:
Signal conditioner ...............................................................(1)
■MODEL NO.
Confirm Model No. marking on the product to be exactly
what you ordered.
■INSTRUCTION MANUAL
This manual describes necessary points of caution when
you use this product, including installation, connection and
basic maintenance procedures.
POINTS OF CAUTION
■POWER INPUT RATING & OPERATIONAL RANGE
• Locate the power input rating marked on the product and
confirm its operational range as indicated below:
24V DC rating: 24V ±10%, approx. 32mA
■GENERAL PRECAUTIONS
• Before you remove the unit or mount it, turn off the power
supply and input signal for safety.
■ENVIRONMENT
• Indoor use.
• When heavy dust or metal particles are present in the
air, install the unit inside proper housing with sufficient
ventilation.
• Do not install the unit where it is subjected to continuous
vibration. Do not subject the unit to physical impact.
• Environmental temperature must be within 0 to 55°C (32
to 131°F) with relative humidity within 30 to 95% RH in
order to ensure adequate life span and operation.
• Be sure that the ventilation slits are not covered with ca-
bles, etc.
■WIRING
• Do not install cables close to noise sources (relay drive
cable, high frequency line, etc.).
• Do not bind these cables together with those in which
noises are present. Do not install them in the same duct.
■AND ....
• The unit is designed to function as soon as power is sup-
plied, however, a warm up for 10 minutes is required for
satisfying complete performance described in the data
sheet.
COMPONENT IDENTIFICATION
Specifications
Span Adj.
Zero Adj.
Mounting Screw
Body
INSTALLATION
Use Installation Base (model: M8BSx).
CONTROL OUTPUT ISOLATOR
(applicable to HART signal) MODEL M8YCH
EM-5449 Rev.1 P. 1 / 2
MG CO., LTD. www.mgco.jp
5-2-55 Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
INSTRUCTION MANUAL
TERMINAL CONNECTIONS
Connect the unit as in the diagram below.
■EXTERNAL DIMENSIONS unit: mm [inch]
I/O PINS
17.5 [.69]
48 [1.89]
75 [2.95]
83 [3.27]
■CONNECTION DIAGRAM
6
8
7
3
11
10
1
4
2
Installation Base
+
–
+
–
+
–
+
LOAD HHC
POWER
*1
*1. Hand-held communicator
*2. Use either 6-7 or 8-9 for input terminal.
OUTPUT
9D
C
B
A
INPUTHHC
*1*2
INPUTHHC
*1*2
–
5
CHECKING
1) Terminal wiring: Check that all cables are correctly con-
nected according to the connection diagram.
2) Power input: Check the power input voltage.
3) Input: Check that the input signal is within 0 – 100% of
the full-scale.
4) Output: Check that the load resistance meets the de-
scribed specifications.
250Ω±10% is required to use HART communication.
ADJUSTMENT PROCEDURE
This unit is calibrated at the factory to meet the ordered
specifications, therefore you usually do not need any cali-
bration.
For matching the signal to a receiving instrument or in case
of regular calibration, adjust the output as explained in the
following.
■HOW TO CALIBRATE THE OUTPUT SIGNAL
Use a signal source and measuring instruments of sufficient
accuracy level. Turn the power supply on and warm up for
more than 10 minutes.
1) ZERO: Apply 0% input and adjust output to 0%.
2) SPAN: Apply 100% input and adjust output to 100%.
3) Check ZERO adjustment again with 0% input.
4) When ZERO value is changed, repeat the above proce-
dure 1) – 3).
MAINTENANCE
Regular calibration procedure is explained below:
■CALIBRATION
Warm up the unit for at least 10 minutes. Apply 0%, 25%,
50%, 75% and 100% input signal. Check that the output
signal for the respective input signal remains within accu-
racy described in the data sheet. When the output is out of
tolerance, recalibrate the unit according to the “ADJUST-
MENT PROCEDURE” explained earlier.
LIGHTNING SURGE PROTECTION
We offer a series of lightning surge protector for protec-
tion against induced lightning surges. Please contact us to
choose appropriate models.
M8YCH
EM-5449 Rev.1 P. 2 / 2
MG CO., LTD. www.mgco.jp
5-2-55 Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN

Other MG Control Unit manuals

MG R6-NE2 User manual

MG

MG R6-NE2 User manual

MG R7E-EA16 User manual

MG

MG R7E-EA16 User manual

MG R7L-EC16B User manual

MG

MG R7L-EC16B User manual

MG R7L-YV2 User manual

MG

MG R7L-YV2 User manual

MG R7K4FML-6-DC32B User manual

MG

MG R7K4FML-6-DC32B User manual

MG Devicenet R7F4DD-DA16A-H User manual

MG

MG Devicenet R7F4DD-DA16A-H User manual

MG R7K4FML3-6-DAC32A User manual

MG

MG R7K4FML3-6-DAC32A User manual

MG R5-RS1A User manual

MG

MG R5-RS1A User manual

MG R80YVT4N User manual

MG

MG R80YVT4N User manual

MG R7E-EC16B User manual

MG

MG R7E-EC16B User manual

MG R80DAT16A2 User manual

MG

MG R80DAT16A2 User manual

MG R3Y-YS4 User manual

MG

MG R3Y-YS4 User manual

MG R7L-YS2 User manual

MG

MG R7L-YS2 User manual

MG R8-SST8 User manual

MG

MG R8-SST8 User manual

MG R5-SS1A User manual

MG

MG R5-SS1A User manual

MG R7ML-EA8 User manual

MG

MG R7ML-EA8 User manual

MG JFK User manual

MG

MG JFK User manual

MG R7L-EC16A User manual

MG

MG R7L-EC16A User manual

MG R6S-TS2A User manual

MG

MG R6S-TS2A User manual

MG R3-CT4B User manual

MG

MG R3-CT4B User manual

MG 10BW User manual

MG

MG 10BW User manual

MG R6S-SS2 User manual

MG

MG R6S-SS2 User manual

MG R7E-EC16A User manual

MG

MG R7E-EC16A User manual

MG R6D-SS2 User manual

MG

MG R6D-SS2 User manual

Popular Control Unit manuals by other brands

TechNexion EDM1-IMX6 manual

TechNexion

TechNexion EDM1-IMX6 manual

Runxin 73605 instruction manual

Runxin

Runxin 73605 instruction manual

Siemens SIMATIC 505 Installation and operation guide

Siemens

Siemens SIMATIC 505 Installation and operation guide

Jolywood M6 installation manual

Jolywood

Jolywood M6 installation manual

Keysight Technologies M8000 Series installation guide

Keysight Technologies

Keysight Technologies M8000 Series installation guide

T&S B-3950 Series Installation and maintenance instructions

T&S

T&S B-3950 Series Installation and maintenance instructions

Huawei MU509-65 Hardware guide

Huawei

Huawei MU509-65 Hardware guide

DOEPFER A-100 Series manual

DOEPFER

DOEPFER A-100 Series manual

ELREHA BMT 2101 operating instructions

ELREHA

ELREHA BMT 2101 operating instructions

Fike MICROMIST 10-2340 user guide

Fike

Fike MICROMIST 10-2340 user guide

Meyer Burger GB installation guide

Meyer Burger

Meyer Burger GB installation guide

Texas Instruments TPS92410EVM-001 user guide

Texas Instruments

Texas Instruments TPS92410EVM-001 user guide

Huawei UPS5000-E-200K-SM user manual

Huawei

Huawei UPS5000-E-200K-SM user manual

LEGRAND Bticino H4652 manual

LEGRAND

LEGRAND Bticino H4652 manual

ZLG CANFDNET-400U user manual

ZLG

ZLG CANFDNET-400U user manual

Atco ADAS-500 user manual

Atco

Atco ADAS-500 user manual

THORLABS LD2000R user guide

THORLABS

THORLABS LD2000R user guide

NXP Semiconductors LPC55S6 Series Application note

NXP Semiconductors

NXP Semiconductors LPC55S6 Series Application note

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.