Realtime TD1D User manual

Applicable Models
Status light
Fingerprint-reading area
Keypad
Card-reading area
Doorbell
Reset
USB
Fixing hole
-1-
Mounting screws
Power on unlock
outage unlocking
Wiring Schematic Diagram A
III.Ports & Wiring Diagram
Access controller
outage unlocking
Wiring Schematic Diagram B
* power
P1
•
0--
+ teams —
12VAlarrn
doorbel"
door ma net
Diagram A instructions is electricity
lock, using a special power supply
access of the connection mode;
Diagram B instructions is electricity
lock and fingerprint access to share
a power supply.
Special attention to protect the
•
Door open button
1 ) Correct
method :
Use the finger to evenly
press the center of
fingerprint are
2) Wrong methods:
S
",--5
0
05\15
0
2_
I.Product Overview and Installation Instruction
Fingerprint Access Control System
User Manual
E A LT IME
Power of Biometrics
ry
•
CD CD 0
000
0 ®®
0
CD
0
(g
,
CD
S.N.
Functions
1
Dark-background fingerprint reader
2
Built-in card reader
3
User verification with fingerprint or card
4
Numeric keys
5
Tamper alarm
6
Reading head for data output
7
86mm box-type panel for installation
Operating Environment:
Room temperature: -20°C-+50°C
Relative humidity: 95%
Operating Voltage & Current:
Input DC: +12V
Standby current:560mA
Operating current:5120mA
0 Due to continuous update of our products
11.Inputting Fingerprint
Suggested finger: index finger, middle finger or
ring finger instead of thumb or little finger
Not Flat
Not !entered
Tilted
Low position
012V
0 RS485A
0 RS485B
O GND
O ALARM1-
0 Bell-
0 Bell+
0 D Sentor
0 Button
0 Lock NO
0 Lock NC
0 Lock COM
0 GND
0 12V
0 12V
0 GND
0 WG-OUTO
0 WG-OUT1
0 12V
0 RS485A
0 RS485B
0 GND
0 ALARM1-
0 Bell-
() Bell-,
0 D Sentor
0 Button
0 Lock NO
0 Lock NC
0 Lock COM
0 GND
0 12V
0 12V

V. Registering User
5.1 Register Users Automatically
IV Administrator Operation
1=>
2.Press(*1)and
the orange
light turns on
1.Standby
mode
2.Input
fingerprint
or read card
3.Verification request succeed(There
is a long beep sound and the blue
light blinks once.)
.4=
2.Enter employee
ID #(1-4 digits)
5.Exit (by
pressing #")
1.Enter administrator password
for verification Once verification
request succeeds, (the blue light
turns on)
1=>.
1.Standby
mode
2.Enter employee ID press
# to for confirmation and
enter password
and pressing (#)
8.2 Setting Unlocking Time
VII. Deleting Users
7.1 Delete a User
<=1
5.1n case the user is in use delete
it. is a long beep There and the
blue light blinks once
2.Press ['9]
and the
1=>
orange light
turns on
1.Enter administrator
passwordfor verification(Once
succeeds verification request
(the blue light turns on)
1.pressnand there is
a beep while the red
light turns on
2.Enter administrator
password (initial
password:123456)
3.Verification request
1=[>
,
succeeds(while the bule
light turns on)
4.Exit (by
pressing
"#")
1.Enter administrator password
for verification.Once verification
request succeeds
(the blue light turns on)
2.Register administrator via
fingerprint or card(input
fingerprint twice or read card
once)
3.Once
registration
request
succeeds
i=>
4.Exit (by
pressing
"tr)
Remarks: once verification request succeeds, 't
is allowed to register administrator and the
initial password will be out of use
4.1
Registering administrator
1.Enter administrator password
for Verification,once verification
request succeeds ( the blue light
turns on)
4.Exit (by
pressing{#}
4.2 Missing administrator password
1.Power off this
device and
dismantle it
3.Registering administrator
via fingerprint or card
(input fingerprint twice or
red card once)
-11
4.Once Registration request
succeeds there is long beep the
blue light blink once
3.Register user via fingerprint
card or password (input
fingerprint twiceread card once
or enter password twice
4.Once registration request
succeeds there is a long
beep and the blue light blink
once
3.Verification request succeed
(There is a long beep sound
and the blue light blinks once.)
5.2 Register Users by Adding Employee ID
Remarks:
1.1t is allowed to register at most 5 administrators via
fingerprint or card
2.1n case administrator quantity reaches the maximum value,
they will be cleared according to serial number.
1.Enter administrator password
for verification Once verification
reguefst
succeeds ( the blue light
turns on)
2.Press [*2]
or enter
administrator
password
3.Enter
employee ID#
14. input fingerprint
or read card
4.In case of incorrect
4
ID# fingerprint or card
there is two beeps and
he red light turns on
1.Enter administrator
password for verification(Once
succeeds verification request
the blue light turns on
2.Press [*3]
and the
orange light
turns on
3.Set unlocking
time (0-99seconds
and press # to for
confirmation)
4.Setup succeeds
There is a long
beep and the blue
light blinks once
i=>
1=>
7.2 Delete All Users
1.Enter administrator password for
verification Once verification
request succeeds (the blue light
turns on)
5.Exit (by
pressing "#")
VIII:Access Control System Management
8.1 System Settings
IX:Unpacking
Description
Specifications
Quantity
Remarks
Device
1
Packaging box
1
Plastic plugs
4mmx28mm
4
For mounting and fixing
Self-tapping screws
4mmx28mm
4
For mounting and fixing
Diode
1n4007
2
i=>
2.Press [*2]
or enter
administrator
password
cg>
3. enter
(0000#)
4.Delete all users
There is a long
beep and the blue
light blinks once
2.Power on tamper
switch to give an alarm ,=>.
for 30 seconds
3.Enter initial
password(*123456) the blue
light turns on
5.Exit (by
pressing
'#")
4.Register
administrator
again
<I=
Verification request falls.
(it beeps twice and the red light turns on)
3.Set system Press
[1] for menu initialization press
[2]for system initializationpress
[3] to delete administrator and then
press [#] for confirmation
5.Exit (by
*4
1=>.
VI. User Operation
6.1 User Verification via Fingerprint or Card
Verification rogues falls.
(It beeps twice and the red light turns on)
6.2 User Verification via Password
5.Exit (by
pressing "#")
5.Exit (by
pressing
"#")
It beeps twice and the red light turns on
Note: 5 seconds have been set as factory default.
Other manuals for TD1D
1
Other Realtime IP Access Controllers manuals
Popular IP Access Controllers manuals by other brands

SECO-LARM
SECO-LARM ENFORCER Wireless RF Request-to-Exit Buttons... manual

IP-COM
IP-COM AC2000V1.0 user guide

NTEK Systems
NTEK Systems Smart Entry quick start guide

Cidron
Cidron Standard Reader installation guide

Identiv
Identiv MobilisID Installation guide and user's manual

GEM
GEM ST-630E Operation manual