ReBuilder Medical 300 User manual

ReBuilder® 300
636 Treeline Drive, Charles Town, WV 25414
304 - 725 - 2202 304 - 725 - 4915

ReBuildeR 300 instRuction Manual 2

1
ReBuilder® 300 Kit
Get to Know your ReBuilder®
Please confirm all the following items are included:
A. ReBuilder® 300 Unit
B. One lead wire
C. 1 Set of adhesive stimulating pads
D. Protective travel case
A.
B. C. D.
...Operating your ReBuilder®
Your ReBuilder® can operate one set of lead wires and one pair
of pads. So you can use one pair of adhesive pads to treat your
feet, hands, back, knees, hips or shoulders.
NOTE: You can only treat one area at a time such as both feet,
hands or shoulders

ReBuildeR 300 instRuction Manual 2
Get to Know your ReBuilder®
...Battery Replacement
Your ReBuilder® is powered by a pre-installed 9 volt battery.
The battery is located in the back of the ReBuilder® unit. To
open, press down with your thumb on the ridged section and
push away from the bottom of the unit. The battery should be
replaced once every 30 days depending on usage.
...Top View of the ReBuilder® 300
Please note the
irregular rounded
shape of the
lead wire when
inserting it into the
input jack.
Input Jack #1 power IndIcator
LIght oFF
end oF
Lead wIre
power &
IntensIty swItch
rounded
power IndIcator
LIght on

3
...Standard Treatment Protocol
Connect the lead wire to input jack. Connect 2 adhesive pads to
leadwire. Place one adhesive pad on the ball of each foot. Turn
the ReBuilder® on and slowly turn up the intensity setting until
you feel a fairly strong tingling sensation and a small amount
of calf muscle activity, then turn the intensity down slightly
until it is gentle enough that you could fall asleep. Use twice
per day for 30 minutes with a minimum of 6-8 hours between
treatments.
NOTE: At higher intensity, you may feel pulsations in your calf
muscle. This is normal. If this results in sore or tired legs, refer
to the troubleshooting guide for assistance.
Using the ReBuilder®
...Gentle Start Treatment Protocol
Turn the ReBuilder® unit on just
until it “clicks” on to the number
“1” intensity setting. Continue
increasing the intensity until you
can just barely notice the impulses.
Use this setting for the first 2 or 3
days to let your nerves acclimate
to the treatment. After the first few
days, gently increase the intensity to the level where you can
feel the impulses but the intensity is still at a level where you
could fall asleep during the treatment. Treat yourself twice per
day with 6-8 hours between treatments. As your body adjusts,
adapts, and improves, the sensitivity level may change and that
is perfectly normal. Your ReBuilder® is working even at very low
settings.
INTENSITY 1

ReBuildeR 300 instRuction Manual 4
Using the Adhesive Pads
Make sure your ReBuilder® is turned off. Plug the lead wire
into the input jack. Place one self-adhesive pad on the
bottom of each foot or affected area. Position the self-
adhesive pads one on the ball of each foot. Placing lead wires
between the toes will help hold the electrodes in place.
Once you have tried the electrodes on the balls of the feet, feel
free to experiment with different areas on the feet and ankles
to see what position will give you the most relief. Position the
electrodes to see what is most effective for you.

5
Adhesive Pads on Other Parts of the Body
The self adhesive pads can also be used on other areas of the
body such as the back, shoulders, and arms. When placing
the pads on the skin, leave approximately 4-6 inches or more
between them. Cleanse the skin of body oil or lotion with
rubbing alcohol before applying the adhesive pads to the skin.
NOTE: When using the adhesive pads on other parts of the
body, two pads have to be used in order for the ReBuilder®
signal to work.
ARMS...
LOWER BACK...
SHOULDERS...
...AND MORE, INCLUDING THIGHS, ELBOWS, & HIPS.
Some additional accessories may be required. If you are unsure about treating
a certain area, call us and we can advise you on the best method for treatment.

ReBuildeR 300 instRuction Manual 6
Replacing the Adhesive Pads
To replace the adhesive pads, grip the plastic end of the black
lead wire and the plastic end of the adhesive pad and pull apart
with a slight twisting motion.
After disposing the worn adhesive pads, take a set of new ones
and insert the metal probe from the black lead wire into the
plastic connection on the end of the new adhesive pad.
Make sure to push the metal probe from the lead wire all the way
in.
pLastIc end oF
adhesIve pad
pLastIc end oF
Lead wIre

7
Care and Maintenance
...Battery Care
Your ReBuilder® has come with a heavy duty 9-volt battery
already installed and ready to use. The battery generally lasts
30 days before needing to be changed. This is based on two
30-minute treatments per day at medium intensity settings.
How long your battery will last will depend on your particular
use. Always remember to turn your ReBuilder off manually with
the knob after your session times out.
...Adhesive Pad Care
Properly cared for, the self-adhesive stimulating pads can last
for many uses. Make sure the skin surface is clean and dry.
Cleaning the skin with an alcohol swab prior to sticking the
pads on your skin helps the pads last longer. Make sure to
replace the pads onto the protective plastic sheet after each
use and store in a cool, dry location. When the pads become
worn and do not stick as effectively, you can lengthen the life by
lightly moistening the skin before placing the pad. This will help
rejuvenate the adhesive a bit for better contact with the skin.
...ReBuilder Unit Care
Your ReBuilder® has an automatic timer that turns off
stimulation between 28 and 32 minutes. Make sure to turn
the intensity knob completely “off” after each use. If you have
difficulty turning on the ReBuilder®, make sure to turn the knob
off and remains off for at least 1 minute to allow the timer to
reset.

ReBuildeR 300 instRuction Manual 8
Everyone’s experience with the ReBuilder® treatment can be
different. Even if you have used the ReBuilder® before in a clinic
setting, using the treatment daily at home results in the best
outcome. The Standard Treatment Protocol is designed to meet
the needs and use ability for the vast majority of ReBuilder® users.
If this protocol is causing any negative reactions, change to the
Gentle Start Protocol mentioned in this booklet.
Any negative reactions indicate your nerves are very receptive
to the ReBuilder®’s impulse and will repair by using a lower
intensity setting. The Standard Treatment Protocol and the
Gentle Start Protocol are fundamental guidelines and your use
may vary. If you have questions about any changes in your
symptoms, refer to the Troubleshooting Guide & Treatment
Questions section, or call us for assistance at 877-717-5487.
If you are sensitive to medications, if your neuropathy symptoms
are hypersensitive (i.e. bed sheets bother your toes or small
things are overly annoying to your symptoms), or develop an
adverse reaction to the treatment, then you should call us for
a program designed specifically for you. Our toll free number
is 87 7-7 17-5487.
What to Expect Using the ReBuilder®
NOTE: If you experience any worsening symptoms or new
symptoms after treatment, refer to the troubleshooting guide
for assistance.

9
Troubleshooting Guide & Treatment Questions
Q: Why do my symptoms feel a little worse after I use the
treatment?
A: The ReBuilder® causes activity in your nerves. For
some, the amount of activity is more than their body is
prepared for, even if you do not feel the stimulation. If you
experienced heightened symptoms after use, discontinue
use for a day or two until your symptoms return to
baseline (your normal level). Then you can return to the
treatment, but at a bit lower intensity than you used
before. If you were only on intensity #1, then reduce the
treatment time by 5 or 10 minutes. After a couple of days
at the lower use, you should be able to increase again and
continue.
Q: Why are my arms/hands or legs/feet tired after treatment?
A: This is normal, because your muscles are being stimulated.
But if it becomes a problem, stop treatment for one or two
days, then return to a lower intensity.
Q: I do not feel any sensation from the treatment, should I turn
it up?
A: Most people are not going to feel any sensation from the
treatment until higher intensity settings. Those with a
significant amount of numbness may not feel much of
anything until very high intensity settings. The ReBuilder® is
working to repair your nerves.

ReBuildeR 300 instRuction Manual 10
Q: Why does the sensation I feel from the treatment decrease
during the treatment session?
A: It is perfectly normal for your nerves to become acclimated
to the sensation and you feel less sensation during the
treatment. This is normal and no need to keep turning the
intensity up.
Q: Am I supposed to reach the highest intensity?
A: There is no goal to reach the highest setting. Unless you
are very numb, you probably will not be comfortable at high
intensity settings. Your comfort will determine how high you
can eventually reach.
Q: Why does the light flash but I can no longer feel any
stimulation?
A: Replace the battery and try again. The lead wire may have
worn out and need to be replaced. If using the Conductive
Garments, they may have worn out and need to be replaced.
If this does not solve the problem, call us at 877-717-5487.
Q: Can I use the treatment more than twice a day?
A: Yes, but avoid irritating your symptoms or tiring your legs or
arms we generally do not suggest more than two treatments
per day. If you do try a third daily treatment start with only
15 minutes. You can work up to a full treatment if your body
is responding well.
Q: How long will it take to see results?
A: Everyone is dierent. Some see results immediately, while
others can take a few weeks before they notice a dierence.

11
Q: The ReBuilder® will not turn on. What do I do?
A: Replace the battery. If the battery is replaced and this does
not solve the problem, call us at 877-717-5487.
Q: Why did the ReBuilder® stop working during my treatment
session?
A: There is an internal timer designed to turn o the stimulation
automatically after the session ends. This is to prevent over
stimulation, as some people fall asleep during treatment.
This automatic timer turns the unit o in approximately 28
to 32 minutes.
Q: My ReBuilder® still works, but why do I have to turn it up
higher and higher to get the same stimulation?
A: Check the battery. Usually the batteries will last approximately
30 to 45 days depending on use before needing to be
replaced. The power indicator can still flash even if the
battery has weakened to the point of reduced or no
stimulation.
Q: Why do I feel the ReBuilder® more in one foot or hand than
the other?
A: You may feel stimulation stronger in one foot or hand than
the other. This is normal even with healthy nerves. For
those with neuropathy, there can be dierences in nerve
function from one foot or hand to the other, increasing this
dierence. The ReBuilder® device is designed to produce a
stronger signal on one side. This provides better outcomes.
Try switching the conductive rubber pads in the footbath or
reversing the socks or inverting the conductive FootPads,
(depending of course on which accessory you are using).

ReBuildeR 300 instRuction Manual 12
Other Products
Call to order from the manufacturer toll free (877) 717-5487, or
order online at www.ReBuildermedical.com.
conductIve gLoves conductIve socks
repLacement Lead wIre
non-adhesIve pads
reBuILder® eLectroLyte spray
adhesIve pads

13
Neuropathy pain and symptoms can be vastly different for each
person, and not all ReBuilder® users will have the same
experience during use or experience the same results after
use.
Your use of the ReBuilder® will be based on your comfort and
experience and may not exactly match the daily outline
in this booklet. It is normal to need to take a day or
two break from treatment occasionally. It is normal to
experience changes in symptoms or experience new or
different sensations from time to time. It is normal for
symptoms to fluctuate during the weeks of treatment.
There are tens of thousands of happy ReBuilder®
users, all of them unique, but with one thing in common:
Relief.
If you need assistance with use, have technical questions
or just need more information, you may contact us by:
◊ Our website at www.ReBuilderMedical.com
◊ By calling toll free 877-717-5487
◊ Or by email at help@ReBuilderMedical.com
Do not use with any accessories or attachments that are
not recommended by the manufacturer. Do not use in any
way other than recommended by the manufacturer.
Manufacturer Comments

ReBuildeR 300 instRuction Manual 14
Precautions & Information
◊ Do not place the electrodes on the neck.
◊ Many people have severe numbness and may not feel the
stimulation of the ReBuilder® initially, but will over time.
◊ Allow 30 days for results. Most symptoms come on
gradually and may take time to resolve.
◊ Even if your patient does not feel a pulse during your
session, the ReBuilder® is still treating their nerves and
muscles.
◊ ReBuilder® Medical does not provide medical advice.
Please consult your physician for a medical diagnosis.
Warranty Information
All warranty claims are to be processed by the manufacturer
directly and must be accompanied by a receipt for purchase
or copy of a dated order to dispense by a certified physician’s
office.
FOR WARRANTY RELATED ISSUES PLEASE CALL BEFORE
RETURNING TO REBUILDER® MEDICAL INC.
For questions concerning warranty or mechanical or operational
problems with your ReBuilder® unit or accessories, please call
toll free 877-717-5487.

15
Information about your 300 ReBuilder®
◊ Registered and cleared by the FDA since 1988.
◊ Can be used to re-educate nerves/muscles.
◊ Provides relief from nerve pain, while increasing blood
flow and strengthening muscles.
...FDA Approved Uses
The ReBuilder® is a cleared device under K as a
prescription device intended for the symptomatic relief of
chronic intractable pain.
The ReBuilder® EMS/TENS was cleared under K as a
prescription device for the following uses:
◊ Relaxation of muscle spasms.
◊ Prevention or retardation of disuse atrophy.
◊ Increasing local blood circulation.
◊ Muscle Re-education.
◊ Immediate post-surgical stimulation of calf muscles to
prevent venous thrombosis.
◊ Maintaining or increasing range of motion.
◊ Symptomatic relief of chronic intractable pain.
◊ Post-traumatic and post-surgical pain relief.

ReBuildeR 300 instRuction Manual 16
Serial Number
Non-sterile
Not for general waste
Caution: Federal (USA) law restricts this device to sale by or on
the order of a Licensed Healthcare Provider.
Keep dry
Consult instructions
Warning: electricity
Manufacturer
Contraindications: Use of the ReBuilder® iscontraindicated for:
individuals with pacemakersor any other implanted electrical
medical devices, for pregnantwomen, and for children under 18
years of age. Use only under direct supervision of your physician
or health care provider if any of the above conditions apply. Do
not use directly over an open wound.Follow your physician’s
advice for specific instructions.
Summary Glossary

17
Helping patients for over 30 years!
ReBuilder® Medical Inc.

Questions
For questions about this product...
Call us toll free at
(877) 717-5487
Visit us on the Web
www.ReBuilderMedical.com
Or email us at
help@ReBuildermedical.com
v191203
Table of contents
Other ReBuilder Medical Medical Equipment manuals
Popular Medical Equipment manuals by other brands

Integra
Integra Codman VPV System manual

Reliance
Reliance FXM920 Installation and Operating Instrucitons

Roscoe Medical
Roscoe Medical RMI-POX4C user manual

ConMed
ConMed Sabre 2400 Operators & service manual

Medicomp
Medicomp SafeMask Architect Pro quick start guide

Zeiss
Zeiss SL Imaging Solution quick guide