PAGE 2 (TWO - INSIDE DPS)
Jupiter Floodlights
Product Codes: JUPS3040, JUPS5040, JUPS10040, JUPS13540, JUPS18040, JUPS24040,
JUPS32040, JUPS30PC40, JUPS50PC40, JUPS100PC40, JUPS135PC40, JUPS180PC40,
JUPS240PC40, JUPS320PC40
Box Contents -
1 x Jupiter Floodlight and mounting bracket
Dimensions:
JUPS30-40/JUPS30PC-40 L: 257 x W: 247 x D: 50mm. Weight: 1.3kg
JUPS50-40/JUPS50PC-40 L: 257 x W: 247 x D: 50mm. Weight: 1.4kg
JUPS100-40/JUPS100PC-40 L: 325 x W: 236 x D: 48mm. Weight: 1.8kg
JUPS135-40/JUPS135PC-40 L: 345 x W: 285 x D: 55mm. Weight: 2.2kg
JUPS180-40/JUPS180PC-40 L: 395 x W: 320 x D: 78mm. Weight: 3.2kg
JUPS240-40/JUPS240PC-40 L: 480 x W: 374 x D: 78mm. Weight: 4.2kg
JUPS320-40/JUPS320PC-40 L: 555 x W: 425 x D: 78mm. Weight: 5.6kg
Material: Body: Die-Cast Aluminium
Lens: Tempered Glass
Working
Temperature: -30°C - 45°C
Safety Warning
• The installation should be carried out
by a qualied electrician in compliance
with the current edition of the IEE
Wiring Regulations.
• Prior to installation, carry out the
necessary risk assessment considering
the people who could be at risk,
the level of risk and the precautions
required to control the risk
• Ensure that the circuit supply is
isolated either by the circuit supply
fuse being removed or the applicable
circuit breaker being turned o before
installation or any maintenance.
• Check the total load on the circuit
ensuring the luminaire does not exceed
the rating of the circuit cable, fuse or
circuit breaker.
• Long-term use and voltage uctuations
can reduce the life span of the tting.
• If the tting incorporates control gear,
ensure careful sizing to avoid instances
of nuisance tripping of the protective
device used in the installation.
• Follow the provided installation
instructions, using the xings supplied
or recommended.
• Keep out of reach of children.
INSTALLATION INSTRUCTIONS
PAGE 1 (FRONT PAGE)
Specication
110-
277V IP65 5
YRS
GUARANTEE
IK07
30-
320
WATT
LED 4000K 4200-
44800LM
Note: This is a Class I Luminaire - Earth connection is required
1. Isolate the mains supply before commencing the installation.
2. Ensure there is adequate free air circulation of at least 100mm around the luminaire. All luminaires run hot. It is the installer’s responsibility to consider any
re risks and take appropriate precautions.
3. The nearest illuminated surface must be at least 0.5m from the front of the tting.
4. Do not install or use if the glass is broken. Replace the luminaire.
5. Select a suitable, solid mounting surface and xings that are capable of holding the weight of the luminaire.
Installation Instructions
Lmm
Wmm