 CONFIGURED USING MONICO VIEW™ SOFTWARE
 ISOLATED PORT CAPABLE OF COMMUNICATING WITH A CDL
PORT
 EASY INSTALLATION
GENERAL DESCRIPTION
Both the Modular Controller Master (enhanced models) and Data Station
Plus contain a proprietary expansion port which provides a high speed, parallel
architecture that extends the functionality and flexibility of the platform. This
approach allows these products to evolve concurrently with the latest advances
in communications and standards, without sacrificing performance. This high
bandwidth channel has significantly greater throughput when compared to the
traditional (external) serial gateway approach.
The XCCDL option card adds a CDL port to the series. This isolated card
protects user equipment from potentially harmful ground loops while providing
high-speed CDL communication options to the end user.
The XCCDL communication card is easily installed by removing the blank
expansion port cover of your Modular Controller or Data Station Plus, and
plugging the XCCDL card into the expansion port. Configuration is simple
using Monico's free Monico View™ software.
SAFETY SUMMARY
All safety related regulations, local codes and instructions that appear in the
literature or on equipment must be observed to ensure personal safety and to
prevent damage to either the instrument or equipment connected to it. If
equipment is used in a manner not specified by the manufacturer, the protection
provided by the equipment may be impaired.
Do not use the controller to directly command motors, valves, or other
actuators not equipped with safeguards. To do so can be potentially harmful to
persons or equipment in the event of a fault to the controller.
CONTENTS OF PACKAGE
- XCCDL option card
- This hardware bulletin
ORDERING INFORMATION
SPECIFICATIONS
1. POWER REQUIREMENTS: 24 V @ 35 mA max. Power is supplied to the
option card from the main board of the Modular Controller Master or Data
Station Plus.
2. COMMUNICATIONS:
CDL Ports: Isolated to help prevent ground loops.
Isolation from XCCDL Communication ports to the Modular Controller
Master or Data Station Plus: 1000 VDC for 1 minute.
3. CERTIFICATIONS AND COMPLIANCES:
Consult factory.
4. ENVIRONMENTAL CONDITIONS:
Operating Temperature Range: 0 to 50°C
Storage Temperature Range: -20 to 80°C
Operating and Storage Humidity: 80% maximum relative humidity (non-
condensing) from 0 to 50°C.
Altitude: Up to 2000 meters.
5. CONSTRUCTION: For indoor use only. Installation Category II, Pollution
Degree 2.
6. INSTALLATION REQUIREMENTS: See “Installing the XCCDL Option
card” for more details.
7. WEIGHT: 1.7 oz (48.2 g)
MODEL XCCDL - CDL OPTION CARD FOR DATA STATION PLUS AND
MODULAR CONTROLLER
MODEL NO. DESCRIPTION PART NUMBER
XCCDL OEMDA006
CAUTION: Risk of Danger.
Read complete instructions prior to
installation and operation of the unit.
1
CDL option card for Data Station Plus
DC : DC
ISOLATING
+
A
-
B
PORT
CDL
BLOCK DIAGRAM
Powered by
Bulletin No. XCCDLM-C
Drawing No. LP0743
Released 01/10
Tel +1 (281) 350-8751 Fax +1 (281) 754-4633
www.monicoinc.com
2
&'/*$7(:$<
ZZZPRQLFRLQFFRP
&'/*$7(:$<
ZZZPRQLFRLQFFRP
Figure 2
Figure 3
EXPANSION
PORT
Figure 4
Figure 1
INSTALLING THE XCCDL OPTION CARD
1. Remove power from the unit
2. Insert a flat-bladed screwdriver into the slot at the top of the expansion port
cover. Gently apply pressure on the screwdriver in an upward direction until
the expansion port cover disengages from the unit as shown in Figure 1.
3. Verify that the option card knobs are in the “unlocked” position as shown in
Figure 2.
4. Carefully insert the option card into the expansion port opening while
aligning the card-edge connector on the option card with the main board's
header, as shown in Figure 3. Once aligned, gently press on the front of the
card until it is flush with the front of the case.
5. Turn the option card knobs to the locked position as shown in Figure 4.
Caution: The expansion and main circuit boards contain static
sensitive components. Before handling the cards, discharge static
charges from your body by touching a grounded bare metal object.
Ideally, handle the cards at a static controlled clean workstation.
Also, handle the cards by the edges only. Dirt, oil, or other
contaminants that may contact the cards can adversely affect circuit
operation.
Warning: Risk of Danger: Be sure to remove all power before
removing the expansion port cover
POWER SUPPLY REQUIREMENTS
NEW AND EXISTING INSTALLATIONS
The XCCDL option card draws all of its power from the main board of the
Modular Controller Master or Data Station Plus. The specifications of the
Modular Controller Master or Data Station Plus account for the power needs of
an option card.
COMMUNICATING WITH THE XCCDL OPTION
CARD
CONFIGURING A XCCDL OPTION CARD
The XCCDL is configured using Monico View software. Monico View is
available as a free download from www.monicoinc.com, or it can be ordered on
CD. Updates to Monico View for new features and drivers are posted on the
website as they become available. By configuring the XCCDL using the latest
version of Monico View, you are assured that your unit has the most up-to-date
feature set. Monico View software can configure the XCCDL through the
RS232 PGM port, USB port, Ethernet port, or CompactFlash socket on your
Modular Controller Master or Data Station Plus. Additional information can be
found in your Modular Controller Master or Data Station Plus hardware
bulletin and the Monico View user manual.
CDL COMMS PORT
The XCCDL option card has one CDL port.
SOFTWARE/UNIT OPERATIONS
XCCDL PORT PIN OUTS
LEDS
The transmit LED(TX) will flash when information is transmitted from the
XCCDL card. The receive LED(RX) will flash when information is received.
MONICO VIEW SOFTWARE
Monico View software is available as a free download from www.monicoinc.
com or it can be purchased on a CD, see “Ordering Information” for part
number. The latest version of the software is always available from the web site,
and updating your copy is free.
TROUBLESHOOTING YOUR XCCDL OPTION CARD
If for any reason you have trouble operating, connecting, or simply have
questions concerning your new XCCDL option card, contact Monico's technical
support. For contact information, refer to the back page of this bulletin for
phone and fax numbers.
EMAIL: [email protected]
Web Site: http://www.monicoinc.com
3
TX/RX
130K
CDL-
2
8
130K
5V
7
1
CDL+
6GND
CDL- (PIN 8)
COMM
N/C
N/C
CDL-
N/C
CDL+ (PIN 1)
CDL+
TXRX
LIMITED WARRANTY
The Company warrants the products it manufactures against defects in materials and workmanship
for a period limited to two years from the date of shipment, provided the products have been stored,
handled, installed, and used under proper conditions. The Company’s liability under this limited
warranty shall extend only to the repair or replacement of a defective product, at The Company’s
option. The Company disclaims all liability for any affirmation, promise or representation with
respect to the products.
The customer agrees to hold Red Lion Controls and Monico Monitoring, Inc. harmless from, defend,
and indemnify RLC against damages, claims, and expenses arising out of subsequent sales of RLC
products or products containing components manufactured by RLC and based upon personal
injuries, deaths, property damage, lost profits, and other matters which Buyer, its employees, or
sub-contractors are or may be to any extent liable, including without limitation penalties imposed by
the Consumer Product Safety Act (P.L. 92-573) and liability imposed upon any person pursuant to
the Magnuson-Moss Warranty Act (P.L. 93-637), as now in effect or as amended hereafter.
No warranties expressed or implied are created with respect to The Company’s products except those
expressly contained herein. The Customer acknowledges the disclaimers and limitations contained
herein and relies on no other warranties or affirmations.
Red Lion Controls
20 Willow Springs Circle
York PA 17406
Tel +1 (717) 767-6511
Fax +1 (717) 764-0839
Monico Monitoring, Inc.
3403 Chapel Square Dr.
Spring TX 77388
Tel +1 (281) 350-8751
Fax +1 (281) 754-4633

Other red lion Controllers manuals

red lion CSMSTRV2V2 Manual

red lion

red lion CSMSTRV2V2 Manual

red lion PAXCDC User manual

red lion

red lion PAXCDC User manual

red lion DA70D User manual

red lion

red lion DA70D User manual

red lion CSMSTRV2-A User manual

red lion

red lion CSMSTRV2-A User manual

red lion PXU100B0 User manual

red lion

red lion PXU100B0 User manual

red lion CSDIO User manual

red lion

red lion CSDIO User manual

red lion PXU User manual

red lion

red lion PXU User manual

red lion Sixnet ST-IPm-8460 Installation instructions

red lion

red lion Sixnet ST-IPm-8460 Installation instructions

red lion TSC User manual

red lion

red lion TSC User manual

red lion CSMSTRSX User manual

red lion

red lion CSMSTRSX User manual

red lion CSMSTRSX User manual

red lion

red lion CSMSTRSX User manual

red lion PAX2C User manual

red lion

red lion PAX2C User manual

red lion SCT User manual

red lion

red lion SCT User manual

red lion PCU User manual

red lion

red lion PCU User manual

red lion PXU User manual

red lion

red lion PXU User manual

red lion CSMSTRLE User manual

red lion

red lion CSMSTRLE User manual

red lion LNXC1 User manual

red lion

red lion LNXC1 User manual

red lion CSMSTR User manual

red lion

red lion CSMSTR User manual

red lion LP1090 User manual

red lion

red lion LP1090 User manual

red lion CSMSTR User manual

red lion

red lion CSMSTR User manual

red lion T48 User manual

red lion

red lion T48 User manual

red lion PAX2C User manual

red lion

red lion PAX2C User manual

red lion PAXCDC30 User manual

red lion

red lion PAXCDC30 User manual

red lion DLC00001 User manual

red lion

red lion DLC00001 User manual

Popular Controllers manuals by other brands

Code 3 3599L5 Installation & operation manual

Code 3

Code 3 3599L5 Installation & operation manual

Uponor SETPOINT 511S Installation and operation manual

Uponor

Uponor SETPOINT 511S Installation and operation manual

EasyIO FS32 installation guide

EasyIO

EasyIO FS32 installation guide

Senect FILTER CONTROL 1200 manual

Senect

Senect FILTER CONTROL 1200 manual

Hamron 010501 operating instructions

Hamron

Hamron 010501 operating instructions

Eaton xComfort CKOZ-00/13 Assembly instructions

Eaton

Eaton xComfort CKOZ-00/13 Assembly instructions

S&P REB 5 quick guide

S&P

S&P REB 5 quick guide

Mitsubishi Electric CNC Specifications and Instruction Manual

Mitsubishi Electric

Mitsubishi Electric CNC Specifications and Instruction Manual

Christie Terra user manual

Christie

Christie Terra user manual

Pentair Raychem ECW-GF installation instructions

Pentair

Pentair Raychem ECW-GF installation instructions

Barco EOS X Terminal user manual

Barco

Barco EOS X Terminal user manual

Hakko Electronics FX-791 instruction manual

Hakko Electronics

Hakko Electronics FX-791 instruction manual

Siemens PolyCool CPS 40 Installation and user manual

Siemens

Siemens PolyCool CPS 40 Installation and user manual

Hunter ICC-800PL Owner's manual and installation instructions

Hunter

Hunter ICC-800PL Owner's manual and installation instructions

Compaq StorageWorks 4100 - RAID Array troubleshooting guide

Compaq

Compaq StorageWorks 4100 - RAID Array troubleshooting guide

AirCom R300 operating manual

AirCom

AirCom R300 operating manual

Beckhoff BC3150 Documentation

Beckhoff

Beckhoff BC3150 Documentation

Johnson Controls M9116-GG-1N4 Series installation instructions

Johnson Controls

Johnson Controls M9116-GG-1N4 Series installation instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.