8
Technical specications
Type of appliance................................................................ vacuum cleaner for dry cleaning
Filter type..............................................................................................................................cyclonic
Model ................................................................................................................................RV-С316-E
Voltage............................................................................................................220-240 V, 50/60 Hz
Rated power...........................................................................................................................1000 W
Maximum power ..................................................................................................................1200 W
Maximum suction power......................................................................................................248 W
Suction power adjusting............................................................................................................yes
Filtration system...............................................................double cyclonic, output EPA-lter
Light container cleaning option..............................................................................................yes
Automatic power cord reeling..................................................................................................yes
Power cord length .......................................................................................................................5 m
Radius ..............................................................................................................................................7 m
Package includes
Vacuum cleaner.........................................1 pc.
Flexible hose ..............................................1 pc.
Combined «2 in 1» nozzle.....................1 pc.
Crevice nozzle ............................................1 pc.
Multipurpose «oor/carpet» brush....1 pc.
Nozzle storage tting..............................1 pc.
Telescopic tube..........................................1 pc.
User manual................................................1 pc.
Service booklet..........................................1 pc.
Energy efciency:
Average annual energy consumption............................................................................ Class C
Dust re-emission (omitting)..............................................................................................Class F
Carpet cleaning performance...........................................................................................Class D
Hard oor cleaning performance.................................................................................... Class A
Sound power level...............................................................................................................80.0 dB
Dust pick up on carpet (the average of the results on carpet) (dpuc) .................. 0.797
Dust pick up on hard oor (the average of the results on crevices) (dpuhf)......1.116
Dust re-emission (omitting)................................................................................................0.95%
The average specic energy consumption on carpet (ASEc).....................1.910 Wh/m²
The average specic energy consumption on hard oor (ASEhf)............1.866 Wh/m²
The annual energy consumption for carpet vacuum cleaners ................... 44.5 kWh/yr
AEc=4*87*50*0.001*ASEc*(1-0.2)/(dpuc-0.2)
Where:
50 is the standard number of cleaning tasks per year
87 is the standard dwelling surface to be cleaned in m²
4 is the standard number of times that a vacuum cleaner passes over each
point on the oor (two double strokes)
0.001 is the conversion factor from Wh to kWh
1 is the standard dust pick-up
0.20 is the standard difference between dust pick-up after ve and after two
double strokes
The annual energy consumption for hard oor vacuum cleaners ............ 28.4 kWh/yr
AEhf=4*87*50*0.001*ASEhf*(1-0.2)/(dpuhf-0.2)
The annual energy consumption for general-purpose vacuum
cleaners.......................................................................................................................... 36.5 kWh/yr
AEgp=0.5*AEc+0.5*AEhf
Manufacturer reserves the right to make any modications to design, packaging,
or technical specications of the product without prior notice.
Vacuum cleaner parts A1
1. Housing
2. Dust collection container
3. Hose connection hole
4. Carrying handle
5.
Dust collection container release
button
6. Rubberized wheels
7. “ON/OFF” button
8. Suction power control
9. Output EPA-lter lid
10.
Automatic power cord reeling button
11. Hose
12. Multipurpose «oor/carpet» nozzle
13. Crevice nozzle
14. «2-in-1» nozzle
15. Telescope tube
16. Nozzle storage tting
Types of nozzles
A. «Floor/carpet» nozzle
B. Crevice nozzle for hard-to-reach places
C.
Combination nozzle «2-in-1» (with brush to clean household appliances and
polished surface, without brush— to clean soft furniture).
I. BEFORE THE FIRST USE
Carefully remove the unit and its accessories from the packaging. Dispose of all pack-
aging materials and promotional stickers.
Keep all warning labels, warning stickers (if any), and serial number identication
label located on the housing. The absence of the serial number will deprive you
of your warranty benets!
After transportation or storage at low temperatures allow the appliance to stay at
room temperature for at least 2 hours before using.
Wipe the housing,the nozzles,the hose and the telescopic tube with a moist cloth and
let them dry.
Vacuum cleaner can be plugged in only when it’s fully assembled with correctly
adjusted lters and the dust collection container!
I I. OPERATION
Assemblage
1. Ensure the vacuum cleaner is unplugged before assemblage.
2. Put the dust collection container down onto projecting front part of the housing
and press down until it clicks.
3. Insert the special exible hose tting into the suction hole until it clicks into
place.
4. Connect the hose handle to the telescopic tube and adjust the necessary nozzle.
Use