Redwall Redscan RLS-3060L User manual

- 1 -
INTRODUCTION
1
CONTENTS
!INTRODUCTION
1-1
BEFORE OPERATION.........................................................................1
1-2
PRECAUTIONS ...................................................................................2
1-3
PARTS IDENTIFICATION ....................................................................2
1-4
INSTALLATION WORK FLOWCHART.................................................2
±TYPES OF INSTALLATION METHOD AND DETECTION AREAS
2-1
TYPES OF INSTALLATION METHOD.................................................3
2-2
TYPES OF DETECTION METHOD.....................................................3
2-3
AREA SETTING PROCEDURE...........................................................4
#
INSTALLATION AND ANGLE ADJUSTMENT
3-1
INSTALLING TO WALL OR CEILING PLANE......................................4
3-2
INSTALLING TO POLE........................................................................5
3-3
INSTALLING ATAN ANGLE TO WALL, CEILING PLANE OR POLE..5
3-4
CONFIRMATION OF LOCATION OF THE LASER PLANE.................6
$PARTS LAYOUT INSIDE THE COVER AND THEIR FUNCTIONS
4-1
WIRING................................................................................................6
4-2
SIGNAL OUTPUT.................................................................................6
4-3
POWERING ON...................................................................................6
4-4
LED FUNCTIONS ................................................................................7
4-5
INITIALIZATION TO FACTORY DEFAULT...........................................7
%SETTING HORIZONTAL DETECTION AREAS 2
5-1
SELECTOR SWITCH OPERATION.....................................................7
5-2
ADJUSTMENT OF HORIZONTAL DETECTION AREA .......................7
5-3
AUTO SETTING OF HORIZONTAL DETECTION AREA.....................8
&SETTING VERTICAL DETECTION AREA
6-1
SELECTOR SWITCH OPERATION.....................................................8
6-2
ADJUSTMENT OF VERTICAL DETECTION AREA.............................9
6-3
AUTO SETTING OF VERTICAL DETECTION AREA..........................9
²AREA CHECKUPS
7-1
WALK TEST.......................................................................................10
7-2
SYSTEM FUNCTION AFTER POWER FAILURE..............................10
(IP CONNECTION WITH REDSCAN
8-1
DEFAULT SETTINGS.........................................................................10
8-2
REDSCAN MANAGER.......................................................................10
8-3
REDWALL EVENT CODE .................................................................10
)SPECIFICATIONS
9-1
SPECIFICATIONS OF THE MAIN UNIT............................................ 11
9-2
DIMENSIONAL DRAWING................................................................. 11
9-3
OPTIONS........................................................................................... 11
1-1
BEFORE OPERATION
Read this instruction manual carefully prior to installation.
This manual uses the following warning indications to provide
information regarding correct usage of the product to prevent
you and other people from being harmed and your assets
from being damaged. These warning indications are described
below.
Ensure you understand these precautions before reading the
rest of this manual.
Warning
Failure to follow the instructions provided by
this warning and improper handling may cause
death or serious injury.
Caution
Failure to follow the instructions provided by
this caution and improper handling may cause
injury and/or property damage.
This symbol indicates prohibition.
The specic prohibited action is provided in and/or around
the gure.
This symbol requires an action or gives an instruction.
Warning
Do not use the product for purposes other than the
detection of moving objects such as people and
vehicles.
Do not use the product to activate a shutter, etc.,
which may cause an accident.
Do not touch the unit base or power terminals of
the product with a wet hand (do not touch when the
product is wet with rain, etc.). It may cause electric
shock.
Never attempt to disassemble or repair the product. It
may cause re or damage to the devices.
Do not exceed the voltage or current rating specied
for any of the terminals, doing so may cause re or
damage to the devices.
Ensure the power is turned off before connecting
wiring.
Conrm the signal name of every terminal to ensure
wiring is carried out correctly.
Whenever a commercial switching regulator is used,
be sure to connect PE (Protective Earth Terminal).
Hold the main unit securely when you install or
service it. Exercise care not to bump the product
against nearby objects or drop it inadvertently.
This product is not capable of detecting objects in the
dead zone of the laser scan.
Do not use this product for an application where it is
not capable of covering the detection area required
by the task.
Please note that the product can malfunction,
including producing an irregular output and
committing a detection error, if it is exposed to
unfavorable environmental conditions such as
strong ambient light, electronic noises or mechanical
vibrations.
Caution
Use of controls or adjustments or performance of
procedures other than those specied herein may
result in hazardous radiation exposure.
Clean and check the product periodically for safe use.
If any problem is found, do not attempt to use the
product as it is.
When disposing of this product, be sure to follow the
waste-disposal regulations of the country or region
where it is used.
This product is intended to detect an intruder(s)
and is not designed to prevent theft, disasters or
accidents. The manufacturer shall not be held liable
for any damage to user’s property resulting from
theft, disasters or accidents.
•
•
FEATURES
* Detection range is 30m (Approx. 100ft.) radius, max. 190 degree
* Selectable horizontal or vertical detection area
* Recognition of the intrusion location which can activate 4
independent outputs for PTZ control
* Flexible and easy setup of the required detection area
* Analog (dry-contact) output and IP connection
REDSCAN is an area sensor that configures a fan-like detection
area of 30 m (Approx.100 ft.) radius over 190 degrees arc. using
laser beams.
REDSCAN detects target objects by emitting laser beams at the
target and measuring the time required for the emitted beams to
be reflected and returned to the detector.
There are 2 modes for detecting an intruder. Horizontal Detection
Area2 and Vertical Detection Area. Each one is configured with
an independent detection algorithm.
No. 59185-11015
INSTALLATIONINSTRUCTIONS
RLS-3060L
Laser Scan Detector
Laser Scan Detector
RLS-3060L

- 2 -
- 3 -
1-2
PRECAUTIONS
Install the product only on a
solid surface. In the Horizontal Detection
Area, this product must
normally be used within the
recommended installation
height in order to detect an
intruder.
Install the product so that the
detection area is not inuenced
by interference from tall grass
or tree branches waving in the
wind.
Do not install or leave the
product in a location exposed
to heat, vibrations or impacts
Do not use the product in an
environment where solvent
fumes or corrosive gases are
present.
Do not use this product in
environments where there
may be oil mist particles which
may contaminate the window
of the detector; thus causing
detection errors and possible
corrosion which may lead to
product failure.
The symbol “Í” indicates prohibited actions.
Cleaning the Product
Clean the front window on a regular basis
using a wet cloth.
A smeared front window can limit the
detection area due to the reduced laser
sensitivity. In addition, heavy soiling of the
window can induce detection errors.
Front window
On Safety of Laser
This product is categorized as a Class 1 product in terms of the
Safety Standard.
Average Power : Max. 0.015 mW (AEL)
Wavelength : 905 nm
Pulse Width : 4 ns
Emission period : 36 μs
Standard : IEC60825-1
Class 1 of the Laser Safety Standard means that the safety
of laser products belonging to this class is warranted under
normal operating conditions (reasonably predictable operating
conditions). The product is marked to indicate that it is laser
equipment. No additional safety measures are necessary.
Complies with 21 CFR 1040.10 and 1040.11 except for
deviations pursuant to Laser Notice No.50,
dated June 24, 2007.
Class 1 laser product
Do not expose your eyes directly to the laser beam.
1-3
PARTS IDENTIFICATION
Mounting bracket Main unit
Cover
Cover mounting screw
Main unit mounting screw
Angle adjustment screw
Accessories>>
4 screws
(For xing the
mounting bracket)
4 anchors
for the wall 1 mounting holes
template
(printed on inside
of the carton box)
2 cable glands
2 screws
(spare parts)
1-4
INSTALLATION WORK FLOWCHART
Walk-test and confirm
the detection area.
(Refer 8-1)
Choose the detection area mode and
installation location. (Refer 2)
Mounting and angle adjustment.
(Refer 3)
Wiring and Power On.
(Refer 4)
Confirmation of location
of the laser plane.
(Refer 3-4)
Area adjustment (Refer 5, 6)
Completion
OK
OK
NG
NG
Installation height:
0.7 m to 1 m
(2.3 ft. to 3.3 ft.)

- 2 -
- 3 -
TYPES OF INSTALLATION METHOD AND DETECTION AREAS
2-Vertical Detection Area H2 V
This mode allows setting of a fan-like detection area in the
vertical direction with a maximum radius of 30 m (Approx. 100 ft.),
a spread angle of 180 degrees.
This mode creates a non detection area, 1.5 m (Approx. 5 ft.) (*1)
immediately in front of the unit, in order to avoid possible false
alarms caused by birds or obstructions close to the unit.
Recommended installation height is from 4 m (Approx. 13 ft.) to
15 m (Approx. 50 ft.).
This mode will detect an object that traverses the detection area.
*1: The Redscan Manager software can change this value or
cancel the “non detection area” for specific applications.
Mounting
height
Ground
surface
30 m (Approx. 100 ft.)
1.5 m (Approx. 5 ft.)
180°
-
Vertical Detection Area when the product is installed at an angle
H2 V
When you have installed this product at an angle with the optional
adjustable angle mounting bracket, the detection area varies as
shown below depending on the installation height and angle.
Mounting angle
Position
60 m (Approx. 200 ft.)
Detection distance
2-1
TYPES OF INSTALLATION METHOD
Installing to a wall Installing to a pole
Detection method Detection method
Horizontal Detection Area 2 Horizontal Detection Area 2
Laser beam Laser beam
Bracket is optional item.
Installing at an angle to a wall Installing at an angle to a pole
Detection method Detection method
Vertical Detection Area Vertical Detection Area
Laser beam Laser beam
Bracket is optional item. Bracket is optional item.
Installing to a ceiling plane Installing at an angle to a
ceiling plane
Detection method Detection method
Vertical Detection Area Vertical Detection Area
Laser beam
Laser beam
Bracket is
optional item.
2-2
TYPES OF DETECTION METHOD
The detection method comprises the two modes of operation,
Horizontal Detection Area 2 and Vertical DetectionArea.
-Horizontal Detection Area 2
H2 V
This mode allows setting of a fan-like detection area in the
horizontal direction with a maximum radius of 30 m (Approx.
100 ft.), a spread angle of 190 degrees.
This mode detects intrusion into the detection area from any
direction.
The Redscan will generate the alarm output for 1minutes after
the initial detection, so long as the detected object stays in the
detection area.
30 m
(Approx.
100 ft.)
190°
Relationship between “detection distance” and mounting
height and mounting angle. See diagram above.
Mounting angle
0° 30° 45°
Installation height
4 m
(13 ft.)
Position 0 (0) 2.3 (7.6) 4.0 (13.1)
Detection
Distance Walking
59 (195) 59 (195) 59 (193)
Crawling
57 (187) 55 (180) 53 (174)
8 m
(26 ft.)
Position 0 (0) 4.6 (15.2) 8.0 (26.2)
Detection
Distance Walking
58 (190) 57 (187) 56 (182)
Crawling
53 (174) 51 (167) 48 (157)
12m
(39 ft.)
Position 0 (0) 6.9 (22.7) 12.0 (39.4)
Detection
Distance Walking
55 (180) 53 (175) 49 (162)
Crawling
50 (164) 48 (157) 46 (151)
Unit: m (ft.)
Note >>
A running person may not be detected if the mounting
angle is 0 degree.

- 4 -
- 5 -
a
d
c
b
INSTALLATION AND ANGLE ADJUSTMENT
3
-Vertical Detection Area
Auto
P1 Fixed detection area
The detection area is xed by the “Area Set” and by the settings
of the Size and Offset parameters. The Redscan will ignore
“noise” at ground level caused by grass or small changes of the
ground shape.
P2 Adaptive detection area
When an object, such as a stack of snow, is in the detection area,
the Redscan will recreate the detection area around the object.
Similarly, if a hole is created in the snow the Redscan will
recreate the detection area to include the hole. This automatic
adaptive area has a default value of +/- 1m.
Area
A2 Area
A1 Area
B1 Area
B2
30 m maximum (Approx. 100 ft.)
Auto P1 (Fix)
Installation
height
Ground
surface
Area A Area B
2Remove the mounting bracket from the main unit.
2-3
AREA SETTING PROCEDURE
The setting procedure comprises two options; P1 and P2.
The setting procedure in each mode varies depending on which
detection method of either Horizontal Detection Area 2 or Vertical
detection Area is selected.
-Horizontal Detection Area 2
Auto
P1 Auto Learning
The area automatically learnt by the sensor within the boundary
dened by “Detection distance adjustment”.
P2 Auto Tracing
The area automatically learnt by tracing a person walking a
boundary within the area set by “Detection distance adjustment”.
P1 (Auto Learning)
P2 (Auto Tracing)
3-1
INSTALLING TO WALL OR CEILING PLANE
1Remove the cover from the main unit.
1Loosen 2 cover mounging screws.
2Remove the cover.
3Attach the mounting holes template (an accessory) onto the
wall or the ceiling plane, and drill 4 mounting holes in it. Drill
2 wiring holes as required.
Insert the anchor bolt (an accessory) into the mounting
holes.
4Fix the mounting bracket on the wall or the ceiling plane.
Cautions>>
When installing the product to the wall, fix the mounting
bracket parallel to the ground. If the mounting bracket is
set at an angle, the laser beam will not be emitted parallel
to the ground, which may result in the non-detection of
an intruder. An inclination of 1degree varies the shape
of the detection area of 30 m (Approx. 100 ft.) ahead by
approximately 0.5 m (1.6 ft.).
Main unit fall-
protection stopper
(Washer without rubber)
1Loosen 4 lock screws. 2Move the
mounting
bracket
3Remove the mounting bracket by moving it
over the stopper while opening the bottom
of the mounting bracket slightly outward.
Angle adjustment
screws a and b Main unit mounting
screws c and d
(Washer with rubber)
A
Mounting hole in 4 locations
Diameter 6 mm (0.24 inches)
Depth 60 mm (2.36 inches)
Set the lower end of the
paper template at a position
at least 0.7 m (28 in.) above
the ground.
Wiring hole
Tighten 4 xing screws for the mounting bracket (accessories).
Rotate the bracket on screw A to the required
position then tighten the xing screws.

- 4 -
- 5 -
5Install the cable gland.
3-2
INSTALLING TO POLE
When installing the product to a pole, use the optional pole
mounting bracket (RLS-PB).
Note >>
For detailed handling procedures, see the manual attached
to the pole mounting bracket.
6Install the main unit and fix it to the mounting bracket.
7See section “ 4-1 ” and connect the wires to the terminal
block.
8It is recommended that the optional Laser Area Checker
(LAC-1) is used to adjust the mounting angle to achieve the
required detection area. (Refer 3-4 )
9See Chapters %, &and ², make various settings and
confirm that the equipment operates correctly.
10 The installation work is complete when the various settings
and operational check are finished. Mount the cover.
3-3
INSTALLING AT AN ANGLE TO
WALL, CEILING PLANE OR POLE
When installing the product at an angle to a wall, ceiling plane or
pole, use the optional adjustable angle mounting bracket (RLS-
SB).
Points >>
The mounting holes for the adjustable angle mounting
bracket align with similar holes in the main unit mounting
holes indicated on the mounting holes template.
Wall Ceiling plane
The angle varies according to the bolt
insertion position.
The angle varies according to the bolt
insertion position.
45°
40°
30°
20°
30° 45°
40°30°20°10°
10°
0°
45°
Pole
Stainless belt
(included with
adjustable angle
mounting bracket)
Adjustable angle
mounting bracket
Note >>
For detailed handling procedures, see the manual attached
to the adjustable angle mounting bracket.
Ensure that any unused
wiring holes are covered
securely with a wiring
hole cap.
Cable gland
Stainless belt
(included with the
pole mounting
bracket)
Pole mounting
bracket (optional)
2Tighten 2 cover
mounting screws.
1Install the cover.
5° 5°
a
d
c
b
1Install the main unit by moving it over the
stopper while opening the bottom of the
mounting bracket slightly outward.
Main unit fall-
protection stopper
3Tighten 4 lock screws.
Angle adjustment
screws a and b Main unit mounting
screws c and d
(Washer without
rubber)
2Insert the top portion
Adjust the angle of the detector
before tightening screws a and b.
(Washer with rubber)

- 6 -
- 7 -
PARTS LAYOUT INSIDE THE COVER AND THEIR FUNCTIONS
4
Re-set
Power
Status
Re-set
Powe
r
Status
3-4
CONFIRMATION OF LOCATION OF
THE LASER PLANE
It is recommended that the optional Laser Area Checker (LAC-1)
is used to confirm the location of the laser plane.
-Horizontal Detection Area
Ensure that the laser beam is hitting the human target between
the shoulder and hip line in all of the detection area taking into
consideration the possibility that the ground level may not be flat.
LAC-1
-Vertical Detection Area
Adjust the mounting angle so that the laser beam is hitting the
ground at the required location.
Note >>
For detailed instructions see the LAC-1 Instruction manual.
4-2
SIGNAL OUTPUT
-D.Q. output
The algorithm specific to REDSCAN allows for
detection during foggy conditions. However, during
severe conditions such as heavy rain, dense fog
or snow storms the Environmental DisQualification
(EDQ) output is activated.
-Alarm output
Upon detecting an intruder, this product outputs the alarm specific
to the general area (Area A1,Area A2, Area B1 or Area B2) where
the intrusion happened.
When combined with a CCTV camera monitoring system
employing PTZ, this product works efficiently to provide early
detection of intruders.
-Tamper output
This output is enabled when the terminal cover is
removed.
-Trouble output
It is generated when an error has occurred on the
sensor.
Name Function
Anti-masking
It is activated when an obstacle
has been placed in front of the
sensor in order to block the
detection area. It is reset after
such obstacles are removed.
Anti-rotation
It is activated when the area
being scanned changes by a
signicant amount as a result of
the unit being rotated from its
original settings.
Soiling of
the window
It is activated when the front
window is heavily soiled which
may induce detection errors.
Clean the front window using a
wet cloth.
Sensor error It is activated when the sensor
has detected an internal self
check error.
-Alarm output
The alarm output is generated if an intruder is
detected in one or more of the divided areas (Area
A1, Area A2, Area B1 and Area B2).
4-1
WIRING
D.Q OUTPUT (N.C.)
D.Q OUTPUT (N.O.) A2 area ALARM OUTPUT (N.O.)
A1 area ALARM OUTPUT (N.O.)
B1 area ALARM OUTPUT (N.O.)
B2 area ALARM OUTPUT (N.O.)
TAMPER OUTPUT (N.C.)
TROUBLE OUTPUT (N.O.)
TROUBLE OUTPUT (N.C.)
ALARM OUTPUT (N.O.)
ALARM OUTPUT (N.C.)
POWER INPUT
ETHERNET
CONNECTOR
*1: TAMPER terminals to be connected to a 24 hour supervisory loop.
Power wires should not exceed the following lengths.
WIRE
SIZE Sensor
24V DC 24V AC
AWG20
(0.52 mm2)
120
(394) 60
(197)
AWG18
(0.83 mm2)
200
(656) 100
(328)
m (ft.)
4-3
POWERING ON
Connect 24 VAC/DC to the power input terminal to
turn power on.
As power is turned on, the indicators (Status and
Power) light for about 30 seconds and then go
out.
During this period, REDSCAN initializes itself.
Indicator Power remains lit as long as power is
turned on.
Legend OFF Light Blink
9 mm
Wires must be stripped back
9 mm.
Use the gauge on the panel for
correct measurement.
Stripped wire length
Approximately
30 seconds
(Initialization is
turned on)
Refer to the end of this
manual for the connection example.

- 6 -
- 7 -
SETTING HORIZONTAL DETECTION AREAS 2
5
4-4
LED FUNCTIONS
-In the normal operation
Symbol Colour DETECTOR STATUS
Status Yellow Lit during auto setup of the unit.
(Turned off during normal operation.)
Power Green Lit when power is turned on
4-5
INITIALIZATION TO FACTORY DEFAULT
You can restore the sensor to the factory default settings (IP
ADDR 192.168.0.126) using the following procedure.
Turn power on and push and hold down the “Re-set” button
within 20 seconds.
Keep holding the button down until the green power indicator is
extinguished.
Only the “Status” indicator is lit during the initialization.
When ALL indicators are extinguished, power cycle (off/on) the
Redscan.
•
•
•
•
Note >>
The following switch settings of the RLS-3060L can only
be changed using the Redscan manager software. Refer
to (for IP connection and the Help menu of the Redscan
Manager software for more details.
5-1
SELECTOR SWITCH OPERATION
-Detection method selection H2 V
Select H2 mode using the Redscan manager.
SELECTOR
POSITION
FUNCTION
H1 Not Applicable by this model.
H2 It selects Horizontal Detection Area 2.
(Factory default)
V—
-Selecting the Auto mode H2 V
SELECTOR
POSITION
FUNCTION
P1 Turns on the Auto Learning. (Factory
default)
P2 Turns on the Auto Tracing.
-Selecting the detection sensitivity H2 V
Set the detection sensitivity using the SIZE and SENS buttons as
per the following chart.
SELECTOR
POSITION
FUNCTION
SApprox. 150 mm
(0.5 ft.) or above This switch
species
the width of
the target
object to be
detected.
MApprox. 300 mm (1 ft.)
or above (Factory
default)
LApprox. 1000 mm
(3.3 ft.) or above
HApprox. 500 mm
(1.6 ft.) or above This switch
species the
distance that
the object
has to move
before it is
considered to
be an intruder.
MApprox. 1000 mm
(3.3 ft.) or above
(Factory default)
LApprox. 2000 mm
(6.6 ft.) or above
5-2
ADJUSTMENT OF HORIZONTAL DETECTION AREA
H2 V
-Detection distance adjustment
You can specify the radius in the range of 0 to 30 m.
Setting detection distance to 0 m deletes the detection area.
Example: if you specify “Detection distance in Area A: 30 m”
and “Detection distance in Area B: 14 m” in a location where the
radius is 30 m or more without obstacles within the detection
area, the following detection areas will result.
Area
B2 Area
B1 Area
A1 Area
A2
15 m7 m
30 m14 m
: Detection area
Factory default : 30m (Approx. 100 ft.)
-Offset adjustment
You can reduce the boundary of the detection area using the
offset parameter. Use this adjustment if blowing grass or tree
bushes might cause a false detection at the edge of the detection
area.
You can reduce the boundary of the detection area (toward the
sensor) by up to 1 m.
Recommended setting is 10 cm minimum.
Offset
Offset
Re-set
Powe
r
Status
Re-set
Powe
r
Status

- 8 -
- 9 -
SETTING VERTICAL DETECTION AREA
6
5-3
AUTO SETTING OF HORIZONTAL DETECTION AREA
-Function of the detection area setting button
H2 V
This button starts the auto function of either P1 or
P2 whichever has been selected.
-Setting P1 (Auto Learning) H2 V
1
Auto P1 (Auto Learning)
Sequence of
operation Status
indicator Time
Action of REDSCAN
1
Click “Area Set” button via
Redscan Manager software.
Flashing
starts
For
1 second
—
—
Fast flashing
For
10 seconds
Scan of the detection area is
executed
—
ON
For
15 seconds
Scan of the detection area is
completed and the data are saved
—
Flashing
For
3 seconds
—
—
OFF
—
Security protection of the detection
area is started
Cautions >>
Do not enter the area while the area scan is being carried out.
An unwanted object in the area interferes with the correct
scanning of the target area.
-Setting P2 (Auto Tracing) H2 V
2
1
Auto P1 (Auto Learning)
Sequence of
operation Status
indicator Time
Action of REDSCAN
1
Click “Area Set” button
via Redscan Manager
software.
Flashing
starts
For
1 second
—
—
Fast flashing
(*2)
For
10 seconds
Scan of the detection
area is executed
2
Walking along the
boundary of the area
(*1)
Flash
(*3)
For
5 minutes
Tracing started
(Last
30 seconds)
—
—
ON
For
15 seconds
Tracing is completed and
the data are saved
—
Flashing
For
3 seconds
—
—
OFF
—
Security protection of the
detection area is started
*1: The tracing is automatically ended after 5 minutes. When
movement of the target object along the area boundary
has finished before this time, you can terminate the tracing
without waiting for 5 minutes by clicking “terminate” button on
Redscan Manager software.
*2: Flashes twice a second
*3: A flashing sequence of flashing twice a second and not
flashing for a second is repeated
Cautions >>
Do not enter the area while the area scan is being carried
out. An unwanted object in the area interferes with the
correct scanning of the target area.
Note >>
Any area left untraced will revert to the Auto learning area
settings.
Note >>
The following switch settings of the RLS-3060L can only
be changed using the Redscan manager software. Refer
to (for IP connection and the Help menu of the Redscan
Manager software for more details.
6-1
SELECTOR SWITCH OPERATION
-Detection method selection H2 V
Select V mode using the Redscan manager.
SELECTOR
POSITION
FUNCTION
H1 —
H2 —
VSelects the vertical detection area.

- 9 -
-Selecting the Auto mode H2 V
SELECTOR
POSITION
FUNCTION
P1 Fixed detection area. (Factory default)
P2 Adaptive detection area.
-Setting the detection sensitivity H2 V
Set the detection sensitivity using the SIZE and SENS buttons as
per the following chart.
SELECTOR
POSITION
FUNCTION
SApprox. 250 mm
(0.8 ft.) or above This switch
specifies the
height from
offset position
of the target
object to be
detected.
MApprox. 350 mm
(1.2 ft.) or above
(Factory default)
LApprox. 500 mm
(1.6 ft.) or above
H
100 ms or longer. This
setting is recommended
when the target object
can run through the
detection area.
This switch
specifies
the duration
during which
the target
object stays in
the detection
area.
M150 ms or longer
(Factory default)
L 200 ms or longer.
6-2
ADJUSTMENT OF VERTICAL
DETECTION AREA
H2 V
-Detection distance adjustment
It can specify the radius in the range of 0 to 30 m.
Setting detection distance to 0 m deletes the area.
Factory default: 30 m (Approx. 100 ft.)
Area
B2
Area
B1
Area
A1
Area
A2
: Detection area
Installation
height
Ground surface
15 m 7m
30 m 14 m
1.5 m
-Offset adjustment
You can reduce the boundary of the detection area using the offset
parameter. Use this adjustment if blowing grass or tree bushes
might cause a false detection at the edge of the detection area.
You can reduce the boundary of the detection area (towards the
detector) by up to 1m.
Recommended setting is 10 cm minimum.
Offset
Ceiling
Ground
surface
Installation
height
6-3
AUTO SETTING OF VERTICAL DETECTION AREA
H2 V
1
Area
B2
Area
B1
Area
A1
Area
A2
Installation
height
Ground surface
Auto P1 (Fix)
Area A Area B
30 m
Sequence of
operation Status
indicator Time
Action of REDSCAN
1
Click “Area Set”
button via Redscan
Manager software.
Flashing
starts
For
1 second
—
—
Fast
flashing
For
10 seconds
Scan of the detection
area is executed
—
ON
For
15 seconds
Scan of the detection
area is completed and
the data are saved
—
Flashing
For
3 seconds
—
—
OFF
—Security protection of
the detection area is
started
Cautions >>
Do not enter the area while the area scan is being carried
out. An unwanted object in the area interferes with the
correct scanning of the target area.

- 10 -
- 11 -
7-1
WALK TEST
H2 V
Ensure that the detection area has been correctly set by
observing the indicators or detection circle on the Redscan
Manager software.
Area
A1
Area
B1
Area
B2 Area
A2
-When a detection area has not been correctly set
1Before pressing the detection area setting button, ensure
that the detection method switch and the detection mode
switch are set to the correct position, respectively.
2Set the detection again with reference to “ 5-3 ” for the
horizontal detection area and “ 6-3 ” for the vertical detection
area.
Summary of detection area switch settings
Function P1 P2
H2 Automatically learns the detection
area within the area set by
“Detection distance adjustment”
Automatically learns the detection
area by tracing a person walking
a boundary within the area set by
“Detection distance adjustment”
V Automatically learns the detection
area within the area set by
“Detection distance adjustment”
Automatically adapts to the
changing shape of the ground area
below the REDSCAN
7-2
SYSTEM FUNCTION AFTER
POWER FAILURE
H2 V
The REDSCAN setup is not lost after a power interruption.
AREA CHECKUPS
7
8-1
DEFAULT SETTINGS
- IP address : 192.168.0.126 (Can be changed)
- Subnet mask : 255.255.255.0 (Can be changed)
8-2
REDSCAN MANAGER
(Optional Setup Software, attached to RLS-AT)
REDSCAN Manager is a software program that allows you
to configure various settings easily via a local network when
installing the REDSCAN unit or performing maintenance work.
REDSCAN Manager can register and manage the REDSCAN
unit located within the local network and display the area
information and the switch setting information obtained from
the REDSCAN unit. Also, it enables you to change the obtained
detection area and switch settings and set them back into the
REDSCAN unit.
REDSCAN Manager also provides the following useful functions.
Selectable application template
*Outdoor (Default)
*Indoor
Activate / Inactivate functions
*Environmental resistance function
Customize parameters
*Non detection area adjustment in V mode
Redwall Event Code setup
*Protocol
*Destination IP address
Note >>
For detailed features and operations, see the help attached
to the REDSCAN Manager.
8-3
REDWALL EVENT CODE
REDSCAN generates event codes which can be used by a NVR
or VMS software to control PTZ cameras and other devices.
Redwall event code can be sent to the assigned port using UDP
or TCP protocol. The default port number is “1234”.
Code format
Address of the REDSCAN
“RLS126 MO A2 TA”
Y1 Y2 Y3 Y10
Master
alarm Latest
alarm Multiple
alarms Tamper
Status Code Status
Y1 MO Master alarm
Y2 A1-B2 Latest alarm
Y3 AA-AB Multiple alarms
Y4 CC Multiple alarms
Y5 DQ Environmental disqualification
Y6 AR Anti-rotation
Y7 AM Anti-masking
Y8 TR Trouble
Y9 SO Soiling of the window
Y10 TA Tamper
IP CONNECTION WITH REDSCAN
8

- 10 -
- 11 -
9-1
SPECIFICATIONS OF THE MAIN UNIT
Model RLS-3060L
Detection method Infrared Laser Scan
Laser protection
class
Class 1 IEC / EN60825-1
Second edition 2007
Class IFDA 21CFR 1040.10,1040.11
(Laser Notice No.50)
Wavelength of laser
emission 905 nm (infrared laser)
Coverage for vertical
mounting Radius: 30 m (Approx. 100 ft.), Arc: 180°
Coverage for
horizontal mounting MAX. 60 m (Approx. 200 ft.)
Detection resolution 0.25°
Power input 24V AC/DC ±10%
Current draw 400 mA (24VDC) 600 mA (24VAC)
Vertical mounting
height From 4 m (Approx. 13 ft.) to 15 m
(Approx. 50 ft.) (recommended)
Horizontal mounting
height 0.7 m (28 in.) (recommended)
Communication port Ethernet, RJ-45,
10BASE-T/100BASE-TX
Protocol UDP, TCP/IP *Redwall event code
Area alarm output N.O. 28V DC, 0.2A × 4 outputs
Master alarm output Form C, 28V DC, 0.2A max.
Trouble output Form C, 28V DC, 0.2A max.
Tamper output N.C. 28V DC, 0.1A max.
Environmental
disqualication
circuit Form C, 28V DC, 0.2A max.
Alarm period Approx. 2 sec. Off delay timer
Warm-up period Approx. 30 sec.
Operating
temperature -20 – +60 °C (-4 – +140 °F)
IP rating IP66
Dimensions
(H × W × D) 334 × 144 × 155 mm
(13.2 × 5.7 × 6.1 in.)
Weight 2.4 kg (85 oz.)
Accessories Mounting screw, anchor fixing for wall,
mounting holes template, and cable gland.
* Specifications and design are subject to change without prior
notice.
9-2
DIMENSIONAL DRAWING
144
(5.7) 155
(6.1) 64
(2.5)
18
(0.7)
334
(13.2)
135
(5.3) 92
(3.6)
107
(4.3)
Unit:mm (inch)
9-3
OPTIONS
RLS-PB : Pole mount bracket
RLS-SB : Adjustable angle mounting bracket
LAC-1 : Laser area checker
RLS-AT : Redscan Adjusting Tools
(Laser area checker and Redscan Manager software)
Conversion Table (meter to feet)
m 0 1 2 4 6 8 10 12 14
ft. 0.0 3.3 6.6 13.1 19.7 26.2 32.8 39.4 45.9
m 16 18 20 22 24 26 28 30
ft. 52.5 59.1 65.6 72.2 78.7 85.3 91.9 98.4
SPECIFICATIONS
9
Wiring holes
4-M20 x 1.5

- 12 -
OPTEX INCORPORATED (USA)
TEL:+1-909-993-5770
Tech:(800)966-7839
URL:http://www.optexamerica.com/
OPTEX KOREA CO., LTD. (KOREA)
TEL:+82-2-719-5971
URL:http://www.optexkorea.com/
OPTEX SECURITYSp.zo.o.(POLAND)
TEL:+48-22-598-06-55
URL:http://www.optex.com.pl/
OPTEX (DONGGUAN)CO.,LTD.
SHANGHAI OFFICE (CHINA)
TEL:+86-21-34600673/34606166
URL:http://www.optexchina.com/
OPTEX CO., LTD. (JAPAN)
(ISO 9001 Certified)
(ISO 14001 Certified)
5-8-12 Ogoto Otsu
Shiga 520-0101
JAPAN
TEL:+81-77-579-8670
FAX:+81-77-579-8190
URL:http://www.optex.co.jp/e/
OPTEX (EUROPE) LTD. (UK)
TEL:+44-1628-631000
URL:http://www.optex-europe.com/
OPTEX SECURITY SAS (FRANCE)
TEL:+33-437-55-50-50
URL:http://www.optex-security.com/

D.Q. OUTPUT (ENVIRONMENTAL DISQUALIFICATION)
The algorithm specific to REDSCAN allows detection of an intruder during fog.
However, during severe conditions such as heavy rain, dense fog or snow storms
the Redscan detection capability may be reduced. During such conditions,
the Enviromental DisQualification (D.Q.) output will be activated.
When this output is activated, other solutions are required to secure the area.
A. Alarm Output + D.Q. Output <RECOMENDED SYSTEM>
B. Bypass Alarm when DQ is activated
Note: With this connection, when the D.Q. output is activated, the alarm circuit is held closed.
C. Bypass Alarm when DQ is activated + D.Q. Output
Note: With this connection, when the D.Q. output is activated, the alarm circuit is held closed.
COM
N.C.
N.O.
COM
N.C.
N.O.
ALARM 1
N.C.
ALARM 2
N.C. (D.Q. OUTPUT)
ALARM
D.Q.
CONTROL PANEL or DVR
COM
N.C.
N.O.
COM
N.C.
N.O.
ALARM
D.Q.
CONTROL PANEL or DVR
RLS-3060 series
ALARM 1
N.C.
COM
N.C.
N.O.
COM
N.C.
N.O.
ALARM 1
N.C.
ALARM 2
N.C. (D.Q. OUTPUT)
ALARM
D.Q.
CONTROL PANEL or DVR
If the control panel's or DVR's input terminal have the same common, the alarm out, and
D.Q. output can be triggered simultaneously.
NOTES : Options B and C above, should only be used in cases where high numbers of
false alarms are being encountered during adverse weather conditions.
Fine
adj.
AutoFunc.Set
P1
P2
H1
V
H2
OffsetSens.
H
M
L
Size
S
M
L
AreaAA2
Power
-1 +1-1 +1-1 0
A1B1B2
AreaB
5
7
3
1
2
4
0
Status
Range
Mode
M
A
0
8
16
24
4
1220
280
4
8
121620
24
28
7
7
RLS-3060 series
Fine
adj.
AutoFunc.Set
P1
P2
H1
V
H2
OffsetSens.
H
M
L
Size
S
M
L
AreaAA2
Power
-1 +1-1 +1-1 0
A1B1B2
AreaB
5
7
3
1
2
4
0
Status
Range
Mode
M
A
0
8
16
24
4
1220
280
4
8
121620
24
28
7
7
RLS-3060 series
Fine
adj.
AutoFunc.Set
P1
P2
H1
V
H2
OffsetSens.
H
M
L
Size
S
M
L
AreaAA2
Power
-1 +1-1 +1-1 0
A1B1B2
AreaB
5
7
3
1
2
4
0
Status
Range
Mode
M
A
0
8
16
24
4
1220
280
4
8
121620
24
28
7
7
Table of contents
Popular Security Sensor manuals by other brands

Bruker
Bruker LYNXEYE XE user manual

Prime Controls
Prime Controls LH200 operating instructions

Videofied
Videofied XT-IP315 Setup and Programming Guide

Optex
Optex URX-P01WH Installation instructions and operators manual

Honeywell
Honeywell FlexGuard FG-1625SN V-Plex installation instructions

Theben
Theben thePrema S360-100 E UP WH manual

United Technologies
United Technologies interlogix 5500 Series installation instructions

AJAX
AJAX MotionProtect user manual

Leuze electronic
Leuze electronic MLC 300 Series manual

ProSimpl
ProSimpl ALF Operation manual

Solutions
Solutions UWT NivoGuide 8200 Technical Information/Instruction manual

Visonic
Visonic SRN-2000 SERIES installation instructions